Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HUMIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Dryness controls temperature-optimized gross primary productivity across vegetation types

Temperature response of gross primary productivity (GPP) is a well-known property of ecosystem, but GPP at the optimum temperature (GPP_T opt ) has not been fully discussed. Our understanding of how GPP_T opt responds to warming and water availability is highly limited. Here, in this study, we analyzed data at 326 globally distributed eddy covariance sites (79°N-37°S), to identify controlling factors of GPP_T opt . Although GPP_T opt was significantly influenced by soil moisture, global solar radiation, mean annual temperature, and vapor pressure deficit in a non-linear pattern (R 2 = 0.47), the direction and magnitude of these climate variables’ effects on GPP_T opt depend on the dryness index (DI), a ratio of potential evapotranspiration to precipitation. The spatial pattern showed that soil moisture did not affect GPP_T opt across energy-limited sites with DI < 1 while dominated GPP_T opt across water-limited sites with DI >1. The temporal pattern showed that GPP_T opt was lowered by warming or low precipitation in water-limited sites while energy-limited sites tended to maintain a stable GPP_T opt regardless of changes in air temperature. Vegetation types in humid climates tended to have higher GPP_T opt and were more likely to benefit from a warmer climate since it was not restricted by water conditions. This study highlights that the response of GPP_T opt to global warming depends on the dryness conditions, which explains the nonlinear control of water and temperature over GPP_T opt . Our finding is essential to realistic prediction of terrestrial carbon uptake under future climate and vegetation conditions.

54 ENVIRONMENTAL SCIENCES↗

Simulation of evapotranspiration and yield of maize: An inter-comparison among 41 maize models

Accurate simulation of crop water use (evapotranspiration, ET) can help crop growth models to assess the likely effects of climate change on future crop productivity, as well as being an aid for irrigation scheduling for today's growers. To determine how well maize (Zea mays L.) growth models can simulate ET, an initial inter-comparison study was conducted in 2019 under the umbrella of AgMIP (Agricultural Model Inter-Comparison and Improvement Project). Herein, we present results of a second inter-comparison study of 41 maize models that was conducted using more comprehensive datasets from two additional sites - Mead, Nebraska, USA and Bushland, Texas, USA. There were 20 treatment-years with varying irrigation levels over multiple seasons at both sites. ET was measured using eddy covariance at Mead and using large weighing lysimeters at Bushland. A wide range in ET rates was simulated among the models, yet several generally were able to simulate ET rates adequately. The ensemble median values were generally close to the observations, but a few of the models sometimes performed better than the median. Many of the models that did well at simulating ET for the Mead site did poorly for drier, windy days at the Bushland site, suggesting they need to improve how they handle humidity and wind. Additional variability came from the approaches used to simulate soil water evaporation. Fortunately, several models were identified that did well at simulating soil water evaporation, canopy transpiration, biomass accumulation, and grain yield. These models were older and have been widely used, which suggests that a larger number of users have tested these models over a wider range of conditions leading to their improvement. These revelations of the better approaches are leading to model improvements and more accurate simulations of ET.

60 APPLIED LIFE SCIENCES↗

Urbanization effects on the spatial patterns of spring vegetation phenology depend on the climatic background

Cities have been considered ideal surrogates for evaluating ecological responses to climate warming. Although research has revealed that the urban heat island effect is not the only determinant that drives the rural-urban difference in spring phenology, limited attempts further explore the effect of complex interactions between urbanization and climates on the start of the season (SOS). Here, we employed the percentage of impervious surface area as an indicator of urbanization levels, incorporating the urban heat island (UHI) effect and climates to decipher the multiple effects on the temporal shift in SOS. Our results suggest that urbanization, the UHI effect, and climates jointly drive the phenological timing in cities. Further, the SOS is highly linearly correlated with urbanization levels and UHI effects (p<0.001) in the zones with warm and humid climates, whereas relatively warmer, cooler, or arid climates break down the linearity. Geographically, the SOS is north-south symmetrical for the rural-urban ecosystem at the national scale, which initiates at the mid-latitudes (around 30 °N, 67.58 DOY ± 2.23 days) first and then towards the low (around 20 °N, 105.25 DOY ± 1.31 days) and high-latitudes (45 °N, 123.01 DOY ± 1.45 days). Chilling accumulation and spring temperature jointly contribute to this phenomenon. As the UHI effect is similar to the projected global warming in the future, understanding the phenological responses to urbanization in various climates is insightful for evaluating the impact of future warming on plants' phenological behavior in the global ecosystem.

54 ENVIRONMENTAL SCIENCES↗

Extreme hydroclimates amplify the biophysical effects of advanced green-up in temperate China

Vegetation phenology modulates climate by altering energy and water exchange between the land and atmosphere. However, how extreme hydroclimatic conditions modify these phenology-climate feedbacks is still poorly understood. Here, in this study, we used a land–atmosphere-coupled Weather Research and Forecasting model to explore the impacts of advanced green-up on air temperature under different hydroclimate conditions across temperate China and to Mechanistic analysis elucidate the underlying biophysical mechanisms. By imposing a 14-day earlier green-up in line with recent satellite observations, we found that under mean climate conditions, an earlier leaf-out induces immediate surface cooling of 0.14 °C during green-up and a lagging 0.02 °C warming during senescence averaged for temperate China. Extremely humid conditions amplify the cooling effects to 0.18 °C during green-up, extending this cooling into the senescence period. Conversely, under extremely arid conditions, earlier green-up cools air temperature by 0.09 °C, and amplified senescence warming to 0.16 °C. Mechanism analysis revealed that evapotranspiration-dominated non-radiative processes drive immediate cooling during green-up while radiation and circulation process dominates the delayed but opposite warming/cooling effects during senescence in extremely arid/humid hydroclimates. Given the projected continuation of warming trends and increased frequency of extreme climatic events, it is imperative to incorporate the biophysical effects of vegetation phenology into local climate adaptation strategies.

54 ENVIRONMENTAL SCIENCES↗

Self-powered Through-wall communication for dry cask storage monitoring

Many nuclear facilities, such as spent fuel storage dry casks and nuclear reactor pressure vessels, are entirely sealed by metal layers to prevent harmful radiation. For safety and security operations, the temperature, pressure, radiation, and humidity inside the vessel needs to be closely monitored. However, no practical technology is currently available to realize the through-wall data communication and monitoring for these vessels due to the inside harsh environment of high temperature and nuclear radiation. In this paper, an innovative self-powered wireless through-wall data communication system for the nuclear environment is presented, which demonstrates a successful solution to such challenges. The presented system is composed of four modules, i.e., energy harvester with power management circuits, ultrasound wireless communication using high-temperature piezoelectric transducers, electronic circuits for sensing and data transmission, and radiation shielding for electronics. Here, constitutive functions of each module were firstly designed and followed by the system integration. Experiments were conducted subsequently to validate the designed functions and evaluate the performance of the integrated system. Results showed that the average power of over 40 mW was harvested from the thermal flow inside the nuclear spent fuel canisters which could provide enough energy to operate the sensing and data communication systems. The gamma radiation test results showed that the thermoelectric energy harvester and ultrasound transceivers can withstand radiation dosing over 100 Mrad. Furthermore, temperature shock tests demonstrated that the entire system including the shielded electronics can survive and maintain their functionalities at temperatures as high as 195°C. Under the in-lab mocked-up high temperature conditions and radiation shielding, the proposed system is foreseen to survive and operate stably for fifty years inside a nuclear spent fuel canister, and send the frequency modulated data out of the canister for 3 s in every 10 min.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coupled chemical–CFD modeling of unsealed dry storage of advanced test reactor spent fuel

We report given the current lack of long-term disposal for spent nuclear fuel storage in the United States, the current inventory of advanced test reactor (ATR) fuel at Idaho National Laboratory (INL) is expected to be stored in a dry storage facility for an extended storage period. As part of an effort to understand the conditions during a 50-year period, a three-dimensional computational fluid dynamics (CFD) of the unsealed canisters packed with spent fuel in the storage facility was constructed, this CFD model is coupled with radiolytic chemical reactions associated with water vapor and other species. The coupled model is simulated over a range of sensitivity parameters for the fuel decay heat, relative humidity, and oxyhydroxide film thickness for undried and fully-dried fuel. The most important parameter was the initial fuel decay heat. Over the range of cases, the hydrogen and nitric acid concentrations are low enough no significant impact is expected.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance assessment of active insulation systems in residential buildings for energy savings and peak demand reduction

Active insulation systems (AISs) in buildings are envelopes that integrate thermal insulation, thermal energy storage, and controls. Although different designs for AISs have been proposed in the literature, a comprehensive analysis of feasible AISs is lacking. This paper discusses the energy performance, peak demand reduction potential, and performance characteristics of an AIS that uses a concrete wall as thermal mass sandwiched between two solid-state thermal switches (STSs). These STSs change their thermal conductivity using an on/off metal switch to create or break a thermal bridge across the STS. This paper first describes the experimental setup, used to determine the ratio of thermal resistance during R-high (low thermal conductivity) and R-low (high thermal conductivity) states of the STSs. This ratio was then used in whole-building energy simulations to evaluate the performance of AIS walls across different climate zones with/without a freeze timer of 60 min. The timer was added to reduce the number of switches of STSs from one state to another, and hence the energy needed for these switches. Analysis of the switching frequency and interval of STSs, thermal conductivity of walls, impact of wall orientation, and heat transfer through the wall from the use of AIS at different climate zones/locations were performed. The simulation results show that the AIS can achieve energy savings ranging from ~980 to 2,290 kWh in a single-family home with a floor area of ~220 m 2 compared with an IECC 2018 baseline. We found the energy savings was higher in dry climate zones which represent 17% of residential buildings in the United States, compared to humid or marine climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Open-cycle thermochemical energy storage for building space heating: Practical system configurations and effective energy density

Salt-hydrate thermochemical materials (TCM) are promising candidates for energy storage systems for building space heating due to their high theoretical energy density and the need for low regeneration temperature. However, water vapor is required to drive the hydration process of the TCM reactor, which poses a challenge during winter when water vapor is typically scarce. Using indoor air directly lowers the building's humidity to an unconformable level in practice, while the cold outdoor air contains limited moisture. Here we consider different integration strategies for open-cycle TCM reactors in buildings and develop a model to simulate their thermal performance across diverse buildings and climates, specifically for building space heating. The potential energy densities and the levelized cost of storage of the TCM reactor are evaluated in practical scenarios to demonstrate the load-shifting potential of TCM systems for heating applications. We use a strontium chloride (SrCl 2 )-based composite as the baseline and explore the impact of various reactor and material changes to the energy density and levelized cost of storage.

25 ENERGY STORAGE↗

Numerical and experimental analysis of precooled desiccant system

This paper presents a numerical and experimental study of four novel, desiccant air-conditioning systems based on pre-cooling of the ambient air. The purpose of the study is to: 1) establish which configuration is most profitable for the future studies through numerical and experimental methods; 2) verify the concept of precooled system and confirm that it is working in experimental conditions (for this purpose two prototypes of evaporative cooling units were developed and compared for different operation arrangements with desiccant wheel); 3) Analyze practical aspects of the systems, which includes water consumption analysis, economic analysis and establishing operational modes during a cooling season in temperate climate conditions (the proposed solution has a significant advantage during operation in a temperate climate, since it can utilize its first evaporative cooler the only source of cooling energy when the humidity of outdoor air allows to to meet the latent cooling load). Four arrangements of the system with different dew point evaporative air cooler prototypes were selected and developed for comparative analysis. The system was simulated as a whole, also, each component was individually tested on measurement station. develop the optimal arrangement of the system through numerical and experimental analysis. Four different performance indicators were considered: thermal COP (Coefficient Of Performance), the ERR (Energy Efficiency Ratio), coefficient a describing the potential in compensating indoor cooling loads, water consumption ratio. Also costs of the systems were compared through economic analysis. It was established that arrangement which is characterized by best-averaged performance in terms of all considered factors is a unit combined with two different types of evaporative coolers (marked as System B)- this is caused by the favorable arrangement of two units, where one is better suited to the pre-cooler role, while the other is better suited as the post-cooler.

42 ENGINEERING↗

On the validity and limitations of 1D model for heat and mass transfer performance evaluation in a multilayer binder-free desiccant dehumidifier: isothermal dehumidification with internal cooling

Efficient humidity control is essential for maintaining indoor thermal comfort, yet conventional vapor-compression-based dehumidifiers are energy-intensive. Employing separate sensible and latent cooling through desiccant-coated heat exchangers (DCHEs) combined with evaporative coolers offers energy savings of up to 80 % compared to conventional systems. However, the dehumidification performance of DCHEs remains limited due to the use of polymer binders for coating desiccant materials onto heat exchange surfaces. In our previous study, we developed a multilayer fixed-bed binder-free desiccant dehumidifier (MFBDD) that demonstrated high dehumidification capacity and low pressure drop compared to rotary desiccant wheels. Nevertheless, its potential for further enhancement through internal cooling and the use of step-shaped adsorption isotherms has not been explored. In this study, a physics-based one-dimensional (1D) transient model is developed and validated to capture the coupled heat and mass transfer processes in the MFBDD and extended to simulate internal cooling using a high-capacity composite metal–organic framework, MIL-101/GO-6 (water uptake ≈1.6 g/g within 35–47 % RH). The model enables detailed analysis of local air and bed temperature dynamics and quantifies how internal cooling affects the dehumidification performance under a wide range of operating conditions. Results show that integrating internal cooling and using MIL-101/GO-6 enhance mass adsorbed, moisture removal capacity, and dehumidification effectiveness by 50 %–99 % compared with the M.S. Gel baseline. The study further reveals that achieving near-isothermal operation requires simultaneous enhancement of the convective heat transfer coefficient and heat exchange surface area. In conclusion, this work provides the first detailed physical insight into the interplay between internal cooling and step-shaped isotherms in a binder-free desiccant device and establishes a validated modeling framework for scaling up and system-level performance evaluation of next-generation energy-efficient dehumidification systems.

Heat and mass transfer↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Sea spray aerosol production flux retrieval based on Doppler lidar measurements

Supermicron sea spray aerosols (SSA) play a crucial role in stratocumulus cloud microphysics and drizzle formation. However, our understanding of SSA's spatiotemporal distribution, production mechanisms, and fluxes in the marine boundary layer remains limited. This study introduces a novel approach to determine supermicron SSA production flux and number concentration at various heights above the ocean surface. Our method leverages Doppler lidar data, specifically attenuated backscatter and vertical velocity, collected at a 105 m range gate during the Eastern Pacific Clouds and Aerosols for Precipitation Experiment (EPCAPE) at Scripps Pier, La Jolla, California. To focus on nascent SSA, we analyzed data from periods with wind directions between 225° and 315° and wind speeds exceeding 4 m s −1 . Cloud and precipitation events were excluded using relative humidity, backscatter thresholds, and 2D Video Disdrometer observations. Results show that calculated supermicron SSA number concentrations at 105 m ranged from 0.26 to 2.93 cm −3 for surface wind speeds between 4 and 6 ms −1 . When exceeding the method's Limit of Detection, estimated production fluxes ranged from 0.20 to 1.53 cm −2 s −1 . This methodology has potential for application in various oceanic locations, likely enhancing our understanding of SSA's role in atmospheric processes and climate interactions.

54 ENVIRONMENTAL SCIENCES↗

Quantifying physical parameterization uncertainties associated with land-atmosphere interactions in the WRF model over Amazon

The Weather Research and Forecasting (WRF) model can be used to diagnose regional land-atmosphere (L-A) coupling strength in the absence of sufficient observations but subjected to uncertainties associated with model physical parameterizations. In this study, we propose a framework to quantify and reduce model physical parameterization uncertainties associated with surface fluxes and L-A coupling. An ensemble of WRF simulations with different physical schemes is used to simulate surface fluxes and land-atmosphere coupling strength over the Amazon region. The physical parameterizations investigated include cloud microphysics (MP), land surface processes (LSM), planetary boundary layer (PBL), surface layer (SL), and cumulus (CU). We perform 120 ensemble simulations using the WRF model and different combinations of six MPs, three LSMs, six PBLs and SLs and three CUs. The measurements from the GoAMAZON field campaign and satellite data are used to evaluate model performance. A Multi-way analysis of variance (ANOVA) approach is applied to quantify the relative importance of different physics processes on L-A coupling. The Tukey’s test is used to sort schemes that have no significant differences into one group. The suite of physics that result in the best simulations of the corresponding variables are selected based on the Taylor skill score. Results show that the relative importance of processes and their interaction vary with the variables of interest. For example, CU was the most important process in modulating soil moisture, 2 m-humidity, latent heat, and net radiation. LSM showed dominant effects on 2 m-temperature and also has the largest impact on sensible heat and the lifting condensation level. The best physical parameterization ensembles show much narrower ranges of the variables of interest than the priori ensemble. Results of this study show the roles of different physical processes in modulating L-A interactions, quantify model uncertainties from physical processes, and provide insights for improving the model physics parameterizations.

Wang, Chen↗

Effect of data assimilation in the Polar WRF with 3DVAR on the prediction of radiation, heat flux, cloud, and near surface atmospheric variables over Svalbard

Although the Polar Weather Research and Forecasting (PWRF) model has been developed for polar environments, simulations of atmospheric states in the polar region still have large uncertainties. Therefore, the effects of data assimilation (DA) to improve forecasts in the polar region were investigated for September 2017 using PWRF and the three-dimensional variational (3DVAR) DA method. The experiments without DA and those with DA assimilating only conventional observations and both conventional observations and satellite radiance data were performed. The forecasts from all experiments both without and with DA underestimated (overestimated) the downward longwave (shortwave) radiation flux due to the underestimation of the amount of Arctic clouds. When satellite radiance data (i.e., the Advanced Microwave Sounding Unit-A (AMSU-A) and Microwave Humidity Sounder (MHS)) were assimilated in addition to conventional observations in the PWRF, the distribution and amount of water vapor became closer to observations, which improves cloud liquid water forecasts. Therefore, when both conventional observations and radiance data were assimilated, the 25–30 h forecast errors of the downward longwave and shortwave radiation fluxes and sensible and latent heat fluxes decreased by 12.7%, 8.1%, 3.2%, and 7.8% with the WSM5 scheme and by 17.1%, 4.7%, 2.5%, and 3.1% with the 2-moment Morrison scheme, respectively, compared to those in the experiments without DA. The forecast errors of the 10 m wind and 2 m temperature with DA were smaller than those without DA at most observation stations. Therefore, the uncertainties of the Arctic forecasts in the PWRF decreased when using DA. To further improve Arctic forecasts, the assimilation of various additional satellite data is necessary.

54 ENVIRONMENTAL SCIENCES↗

Investigation on cloud vertical structures based on Ka-band cloud radar observations at Wuhan in Central China

Based on vertically pointing observations of Ka-band frequency-modulated continuous millimeter wave cloud radar (MMCR) in 2020, we investigate cloud vertical structures at Wuhan in central China. Case comparison indicates that the cloud top locations in the MMCR observation are largely consistent with those in satellite data. The precipitation has the occurrence frequency of 9.5% over the year, with the maximum value of 16.3% in July and the submaximal value of 14.7% in January, showing the significant influences of monsoons on precipitation at Wuhan. As the humid, cloudy and rainy climate, the probability of precipitation and non-precipitation clouds increases gradually from 53.9% in January to a large value of 71.5% in July. The non-precipitation clouds have the probability of 44.5% in the year, with two prominent peaks at the reflectivities of -35 to -30 dBZ around 12 km in summer and - 37– -32 dBZ around 10 km in spring. The cloud top can reach the heights of 14.49, 16.62, 13.38 and 11.73 km from spring to winter, respectively. The monthly mean cloud layer thickness is the largest (2.18 km) in May and September, and the smallest (1.36 km) in November. The seasonally averaged base and top heights and thickness of clouds have small diurnal variations. The high cloud is predominant in the warm months from May to September, and in the other cool months, the middle cloud has the most fraction. The quantitative investigation of clouds is helpful in improving the cloud parameterization in climate models.

54 ENVIRONMENTAL SCIENCES↗

Observational study of relationships between entrainment rate, homogeneity of mixing, and cloud droplet relative dispersion

The entrainment–mixing process is key to the cloud’s dynamical and microphysical processes. However, to the best of our knowledge, no study has quantitatively linked entrainment rate and homogeneity of mixing. Additionally, their combined effects on cloud droplet relative dispersion and physical mechanisms are even more unclear. This study analyzed the aircraft measurements of cumulus clouds collected in the Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecosystems field campaign to identify these relationships. The relationship between the entrainment rate and homogeneous mixing degree was found to be moderately positive, and the underlying mechanisms related to mixing and evaporation time scales and environmental relative humidity were explored. The relationship between relative dispersion and entrainment rate changes from positive to negative with increasing entrainment rate, depending on the dominance of evaporation of large or small droplets. The relative dispersion first increases and then decreases with increasing homogeneous mixing degree, validating the results of previous model simulations. Further, the results shed new light on understanding the interactions between cloud microphysics and cloud dynamics through turbulent entrainment and mixing processes.

54 ENVIRONMENTAL SCIENCES↗

Association of residential energy efficiency retrofits with indoor environmental quality, comfort, and health: A review of empirical data

This paper reviews empirical data from evaluations of the influence of residential energy efficiency retrofits on indoor environmental quality conditions and self-reported thermal comfort and health. The data were extracted from 36 studies described in 44 papers plus two reports. Nearly all reviewed studies were performed in Europe or United States. Most studies evaluated retrofits of homes with low-income occupants. Indoor radon and formaldehyde concentrations tended to increase after retrofits that did not add whole-house mechanical ventilation. Study-average indoor concentrations of nitrogen dioxide and volatile organic compounds other than formaldehyde increased and decreased with approximately equal frequency. Average indoor temperatures during winter typically increased after retrofits, usually by less than 1.5 °C. Dampness and mold, usually based on occupant's reports, almost always decreased after retrofits. Subjectively reported thermal comfort, thermal discomfort, non-asthma respiratory symptoms, general health, and mental health nearly always improved after retrofits. For asthma symptoms, the evidence of improvement slightly outweighed the evidence of worsening. There was insufficient evidence to determine whether changes in thermal comfort and health outcomes varied depending on the type of energy efficiency retrofit. The published research has numerous limitations including a lack of data from retrofits in warm-humid climates and minimal data on changes in objective health outcomes. Suggestions for future research are provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How can we combine urban cooling strategies to effectively cool cities over the entire diurnal cycle?

The urban heat island effect generally peaks in the night/evening hours and, in some cases, an urban cool island effect during daytime has been reported. These patterns are observed mainly because of the widespread use of impervious and thermally massive materials (like concrete and asphalt) in the built environment and their ability to store energy during the daytime and release it at night. Unfortunately, most urban cooling strategies, such as cool (white), green, and blue spaces, provide better thermal performance during the daytime than at night. Hence, such solutions are not ideal for nighttime heat mitigation. In this study, we investigate the effect of the thermal storage capacity of existing buildings on nighttime urban air temperature for a hot arid city—Phoenix, and a hot humid city—Atlanta. The study uses regional scale atmospheric modeling to compare the nighttime urban cooling capability of thermally light buildings (Cross-laminated timber buildings in this case) with concrete buildings. The results show that the adoption of thermally light buildings reduce nighttime air temperatures, and slightly increases daytime air temperatures. On the other hand, cool roof adaption could reduce urban air temperature significantly during the daytime and slightly at night. Therefore, together with cool roofs, thermally light buildings may be able to cool the surrounding air by an average of about 1°C throughout the diurnal cycle, providing thermal comfort and reducing cooling demand during all hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗