THE COMPOSITE BEHAVIOUR OF FILAMENT-WOUND MATERIALS
Heterogeneity and anisotropy of a glass filament imbedded epoxy resin layer from material and geometric parameters
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Heterogeneity and anisotropy of a glass filament imbedded epoxy resin layer from material and geometric parameters
Optimum gasket designs for lox and liquid hydrogen application
Wide thin flat microtape minimizing permeability of filament-wound containers for cryogenic liquids
Precision winding of cylindrical composites with shaped glass filaments - mechanical property determination
Flexure rigidity and tensile strength of Dacron- glass yarn and fiberglass
Cross linking in Styrene-Butadiene Rubber /SBR/ glass bead composites
Chemical bonding between glass and plastic in glass reinforced plastic composite material
Evaluation of fibrous materials in cryogenic structural polyurethane adhesive used for bonding Saturn S-IVB tank assembly attachments
Procedures for fluorination and alkylation of glass fabric for subsequent use in production of laminates
Crystallization kinetics and impact tests of glass fiber-epoxy composites
Flexural, shear, bending, tensile, and impact strengths of high modulus, high strength, glass fiber-epoxy resin composites
The laminate fabrication procedures and quality assurance ultrasonic C-scan results used for structural elements are described. These procedures are the result of processing eleven lots of graphite/PMR-15 prepreg tape materials and two lots of graphite/NR-150B2. Early processing difficulties with NR-150B2 composites were corrected, permitting the fabrication of quality specimens from either of the two currently prescribed matrix materials. The quality of all deliverable specimens is measured by the control of fiber content, glass transition temperature, and void content, as well as laminate ultrasonic C-scan data.
The possibility of using general formulas for determining the strength of different anisotropic materials is considered, and theoretical formulas are applied and confirmed by results of tests on various nonmetallic materials. Data are cited on the strength of wood, plywood, laminated wood plastics, fiber glass-reinforced plastics and directed polymer films.
Glass compositions having a Young's modulus of at least 15 million psi are described. They and a specific modulus of at least 110 million inches consist essentially of, in mols, 15 to 40% SiO2, 6 to 15% Li2O, 24 to 45% of at least two bivalent oxides selected from the group consisting of Ca, NzO, MgO and CuO; 13 to 39% of at least two trivalent oxides selected from the group consisting of Al2O3, Fe2O3, B2O3, La2O3, and Y2O3 and up to 15% of one or more tetravelent oxides selected from the group consisting of ZrO2, TiO2 and CeO2. The high modulus, low density glass compositions contain no toxic elements. The composition, glass density, Young's modulus, and specific modulus for 28 representative glasses are presented. The fiber modulus of five glasses are given.
An account is given of the composite fabrication techniques envisioned for the production of mirror-quality substrates furnishing the specular reflectance required for the NASA Space Station's solar dynamic concentrator energy system. The candidate materials were graphite fiber-reinforced glass, aluminum, and polymer matrices whose surfaces would be coated with thin metal layers and with atomic oxygen degradation-inhibiting protective coatings to obtain the desired mirror surface. Graphite-epoxy mirror substrate samples have been found to perform satisfactorily for the required concentrator lifetime.
Recent advances in ceramic and other high-temperature composites have created a need for test methods that can be used at 1000 C and above. Present test methods usually require adhesively bonded tabs that cannot be used at high temperatures. This paper discusses some of the difficulties with high-temperature test development and describes several promising test methods. Stress-strain data are given for Nicalon ceramic fiber reinforced glass and glass-ceramic matrix composites tested in air at temperatures up to 1000 C.
An account is given of an inspection method that has been successfully used to assess the postimpact damage and residual strength of syntactic (glass microspheres in epoxy matrix) foam-core sandwich panels with hybrid (carbon and glass fiber-reinforced) composite skins, which inherently possess high damage tolerance. SEM establishes that the crushing of the microspheres is responsible for the absorption of most of the impact energy. Damage tolerance is a function of the localization of damage by that high impact energy absorption.
The present invention provides a simple, portable, relatively inexpensive apparatus for accurately and efficiently collecting, separating, testing, and even storing between about 1-20 ml, preferably about 1-10 ml, of blood or other bodily fluid in situ. The apparatus includes a collection chamber bounded on its sides by an opening in a sheet of material, preferably clear plastic, abutting a filter card. The filter card is made of fibrous material, preferably less than about a millimeter thick, having an average pore size of less than about 3 microns. Preferably, the fibers are glass and the fibrous material has an average pore size of about 1 micron. The fibrous material is treated with a carbohydrate/protein mixture which contains between about 1-40 percent wt/vol carbohydrate and about 0.1-15 percent wt/vol nonspecific protein, preferably between about 10-20 percent carbohydrate and about 5-8 percent protein. A preferred carbohydrate/protein mixture comprises about 10 percent mannitol and about 6 percent albumin. The blood or other fluid moves through the filter card by capillary action aided by an absorbent matrix with a high Klemm factor which abuts the filter card. The absorbent matrix and/or filter card can be treated with a wide spectrum of test reagents. The speed, cleanliness, and efficiency of the separation process can be altered by: (a) changing the absolute concentration of the carbohydrate/protein mixture; (b) applying positive or negative pressure to one side of the filter; and/or (c) varying the relative density and pore size of the filter card and absorbent matrix.