Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Event planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

DarkSide-20k: A 20 tonne two-phase LAr TPC for direct dark matter detection at LNGS

Abstract. Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LAr TPC) with an active (fiducial) mass of 23 t (20 t). This paper describes a preliminary design for the experiment, in which the DarkSide-20k LAr TPC is deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). This preliminary design provides a baseline for the experiment to achieve its physics goals, while further development work will lead to the final optimization of the detector parameters and an eventual technical design. Operation of DarkSide-50 demonstrated a major reduction in the dominant 39Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of > 3 × 109 is achievable. This, along with the use of the veto system and utilizing silicon photomultipliers in the LAr TPC, are the keys to unlocking the path to large LAr TPC detector masses, while maintaining an experiment in which less than < 0.1 events (other than ?-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ, giving sensitivity to WIMP-nucleon cross sections of 1.2×10 -47 cm2 (1.1×10 -46 cm2) for WIMPs of 1TeV/c2 (10TeV/c2) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background.

Aalseth, Craig E.↗

Outline for a theory of intelligence

Intelligence is defined as that which produces successful behavior. Intelligence is assumed to result from natural selection. A model is proposed that integrates knowledge from research in both natural and artificial systems. The model consists of a hierarchical system architecture wherein: (1) control bandwidth decreases about an order of magnitude at each higher level, (2) perceptual resolution of spatial and temporal patterns contracts about an order-of-magnitude at each higher level, (3) goals expand in scope and planning horizons expand in space and time about an order-of-magnitude at each higher level, and (4) models of the world and memories of events expand their range in space and time by about an order-of-magnitude at each higher level. At each level, functional modules perform behavior generation (task decomposition planning and execution), world modeling, sensory processing, and value judgment. Sensory feedback control loops are closed at every level.

Albus, James S.↗

Security and Emergency Management: NMPEA Application

The Security and Emergency Management (S&EM) Center at Sandia National Laboratories (SNL) is responsible for ensuring overall security for people, information, and facilities at SNL. The center runs a broad Security and Emergency Management Program in close cooperation with other organizations throughout SNL. The mission of the Security program is to minimize current and future security threats so that Sandia can protect, sustain and enhance SNL’s ability to function as a multidisciplinary national security laboratory. The mission of the Emergency Management program is to provide SNL with dedicated professionals who deliver safe, prompt, courteous, efficient emergency planning and response to fire-related incidents, hazardous materials, confined space, emergency medical emergencies, and non-emergency events to protect the workers, the public and the environment. They embrace mission success in the National Interest, actively supporting all Divisions. The Emergency Management (EM) Program’s vision is to be recognized by SNL/NM and the entire DOE complex as the model for superior emergency management services. Emergency Management plans to accomplish this vision through a leadership philosophy that promotes respect and mutual trust among all members through open and honest communication.

99 GENERAL AND MISCELLANEOUS↗

A Nonlinear Regression Method for Composite Protection Modeling of Induction Motor Loads

Protection equipment are used to prevent damages to induction motor loads by isolating those from the power network in the event of severe faults. Modeling the response of induction motor loads and their protection is vital for power system planning and operation, especially in understanding system's response moments after a fault has occurred. This article proposes an optimization based framework to generate composite protection models for commercial building motor loads. Introducing a mathematical abstraction, the task of finding a suitable (simplified) model of the composite protection scheme is formulated as a nonlinear regression problem. Numerical examples are provided to illustrate the application of the framework.

Kundu, Soumya↗

An RTDS-Based Testbed for Investigating the Impacts of Transmission-Level Disturbances on Solar PV Operation

The increasing penetration of renewable energy resources such as solar and wind via power electronic inverters is challenging grid dynamics, as well as grid planning, operation, and protection. Recently, the North American Electric Reliability Corporation (NERC) has reported a series of similar events of the unintended loss of solar generation in Southern California over a large geographic area following the transmission-level disturbances. These events highlight the importance of understanding the characteristics of the transmission-side disturbances propagating into the distribution systems and their impacts on the operation of inverter-based resources. In this paper, a real-time electromagnetic simulation testbed is constructed for real-time electromagnetic simulations to generate realistic transmission-level disturbances and investigate their impacts on the solar PV operation under different fault types and locations, solar penetration levels, and loading levels. Through the simulation analysis and grid strength assessment, it is found that the grid strength at points of integration (POIs) of solar PVs significantly affects the transient stability of solar generators. Particularly, undesirable transient stability events are more likely to occur at the weak POIs following the transmission-level disturbances. Moreover, undesirable transient stability events become severer when the transmission-level disturbance is closer to the weak POIs or the disturbances become more serious. Additionally, the impact of the transmission-level disturbances on the solar PVs at the weak POIs exacerbate with the increasing solar penetration levels and loading levels. Thus, it is important to study and develop new technologies for grid planning, operation, and protection in weak grid conditions to address the emerging issues of integrating the high penetration of solar PVs and other IBRs.

14 SOLAR ENERGY↗

Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved software design, and manufacturer–user training may help mitigate these events.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of cosmogenic production of 39 Ar and 42 Ar for rare-event physics using underground argon

Underground argon (UAr) with lower cosmogenic activities of 39 Ar and 42 Ar has been planned as a detector in detecting scintillation light and charge collection using time projection chambers for dark matter searches and as a veto detector in suppressing backgrounds for neutrinoless double beta decay (0$vββ$ ) experiments. Long-lived radioactive isotopes, 39 Ar and 42 Ar, can also be produced on the surface when UAr is pumped out from a deep well. Understanding the production of long-lived isotopes in Ar is important for utilizing UAr for dark matter and 0$vββ$ experiments in terms of its production, transportation, and storage. Ar exposure to cosmic rays at sea-level is simulated using Geant4 for a given cosmic ray muon, neutron, and proton energy spectrum. Here we report the simulated cosmogenic production rates of 39 Ar, 42 Ar, and other long-lived isotopes at sea-level from fast neutrons, high energy muons, and high energy protons. Total production rates of 938.53/kg Ar day and 5.81 × 10 -3 /kg Ar day for 39 Ar and 42 Ar are found from our simulation. Utilizing these production rates, we set a time limit of 954 days constrained by the production of 39 Ar for UAr to be on the surface before it compromises the sensitivity for a dark matter experiment. Similarly, a time limit of 1702 days constrained by the production of 42 Ar is found for a 0$vββ$ experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent trends in power system reliability and implications for evaluating future investments in resiliency

Here, this study examines the relationship between annual changes in electricity reliability reported by a large cross-section of U.S. electricity distribution utilities over a period of 13 years and a broad set of potential explanatory variables, including weather and utility characteristics. We find statistically significant correlations between the average number of power interruptions experienced annually and above average wind speeds, precipitation, lightning strikes, and a measure of population density: customers per line mile. We also find significant relationships between the average number of minutes of power interruptions experienced and above average wind speeds, precipitation, cooling degree-days, and one strategy used to mitigate the impacts of severe weather: the amount of underground transmission and distribution line miles. Perhaps most importantly, we find a significant time trend of increasing annual average number of minutes of power interruptions over time—especially when interruptions associated with extreme weather are included. Lastly, the research method described in this analysis can provide a basis for future efforts to project long-term trends in reliability and the associated benefits of strategies to improve grid resiliency to severe weather—both in the U.S. and abroad.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decentralized modular hybrid supervisory control for the formation of unmanned helicopters

Abstract Formation control of Unmanned Aerial Vehicles (UAVs) requires them to tightly cooperate to reach and keep the formation, while avoiding collision. This paper proposes a novel decentralized hybrid supervisory control approach for the formation control of multiple UAVs. This is achieved by developing a symbolic motion planning technique to polarly partition the motion space resulting in a finite state discrete event model for the motion dynamics of each UAV. Then, a modular discrete supervisor is designed for different components of the formation mission including reaching the formation, keeping the formation, and collision avoidance. Further, for the collision avoidance mechanism, a novel top‐down decomposition‐based approach is developed to design local supervisors decentralizedly. It is formally proved that with the proposed top‐down decomposition‐based approach, the (locally) supervised UAVs, as a whole, can cooperatively satisfy the desired (global) collision avoidance specification. The proposed decentralized supervisory control algorithm is also verified through a hardware‐in‐the‐loop simulator for the formation control of unmanned helicopters.

Karimoddini, Ali↗

Assessment of NDE for Key Indicators of Aging Cables in Nuclear Power Plants – Interim Status

Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. System tests verify cable function under normal loads; however, the concern is over cable performance under exceptional loads associated with design-basis events (DBEs). The cable’s ability to perform safely over the initial 40 year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program to justify cable performance under normal operation as well as accident conditions. Currently the gold standard for determining cable insulation degradation is the elongation-at-break (EAB). This, however, is an ex-situ measurement and requires removal of a sample for laboratory investigation. A reliable nondestructive examination (NDE) in-situ approach is desirable to objectively determine the suitability of the cable for service. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none of these tests are suitable for all cable configurations nor does any single test confirm all features of interest. Nevertheless, the complete collection of test possibilities offers a powerful range of tools to assure the integrity of critical cables. Licensees and regulators have settled on a practical program to justify continued operation based on condition monitoring of a lead sample set of cables where test data is tracked in a database and the required test data are continually adjusted based on plant and fleet-wide experience. As part of the Light Water Reactor Sustainability program sponsored by the U.S. Nuclear Regulatory Commission, the U.S. Department of Energy, and industry (represented by the Electric Power Research Institute), an assessment of cable NDE methods was commissioned. Technologies include both bulk electrical measurements (Tan d, time domain reflectometry, frequency domain reflectometry (FDR), partial discharge, and other techniques) and local insulation measurement (indenter, dynamic mechanical analysis interdigital capacitance, infrared spectral measurement, etc.). This aging cable NDE program update reviews the full range of techniques but focuses on the most interesting test approaches that have a chance to be deployed in-situ, particularly including Tan d, FDR, and ultrasound methods that have been reviewed most completely in this progress period.

cable aging inspection↗

Science with a wide-field UV transient explorer

The time-variable electromagnetic sky has been well-explored at a wide range of wavelengths. In contrast, the ultra-violet (UV) variable sky is relatively poorly explored, even though it offers exciting scientific prospects. Here, we review the potential scientific impact of a wide-field UV survey on the study of explosive and other transient events, as well as known classes of variable objects, such as active galactic nuclei and variable stars. We quantify our predictions using a fiducial set of observational parameters which are similar to those envisaged for the proposed ULTRASAT mission. We show that such a mission would be able to revolutionize our knowledge about massive star explosions by measuring the early UV emission from hundreds of events, revealing key physical parameters of the exploding progenitor stars. Such a mission would also detect the UV emission from many tens of tidal-disruption events of stars by supermassive black holes at galactic nuclei and enable a measurement of the rate of such events. The overlap of such a wide-field UV mission with existing and planned gravitational-wave and high-energy neutrino telescopes makes it especially timely.

79 ASTRONOMY AND ASTROPHYSICS↗

The Effect of Power Electronic Loads on Western Interconnection Stability

The prevalence of power electronics in the bulk power system is increasing rapidly in both the generation and consumption of electricity. This work focuses on the effect of changing load composition - specifically the transition from single phase air conditioner motors to power electronics backed air conditioners - on power system stability. Various transmission and generation contingency events for the Western Interconnection were simulated using Positive Sequence Load Flow software and planning models from the Western Electricity Coordinating Council. In general, an increased proportion of power electronic load leads to more instability. For some specific faults resulting in fault-induced delayed voltage recovery, transitioning to higher proportions of power electronic loads helps expedite system recovery. These results demonstrate that load composition should be examined in conjunction with generation composition when evaluating system stability.

FIDVR↗

Model Agnostic Bayesian Framework for Online Anomaly/Event Detection in PMU Data

Phasor measurement units (PMU) are integral to the modernization and automation plan of the electric power industry. A PMU data signature contains system-level events (e.g., faults, generation/load change, etc.) and any measurement/device-related errors. Therefore, the reliable and resilient operation of power systems is equivalent to the quality of the PMU data and the situation awareness provided by its data signature. Despite recent progress, current state-of-the-art methods are not fool-proof and have certain limitations tracing an error/abnormality to sensor sub-components and grid systems. This is because of technical challenges imposed by the scarcity of the labeled information, loss of data quality, and non-stationarity of data. In this paper, we consider the online PMU data stream as an output of a stochastic process and pose the anomaly/event detection as a changepoint detection problem dealing with detecting parameter changes in the underlying stochastic processes. The proposed model-agnostic framework relies on: (a) feature extraction utilizing the minimum volume enclosing ellipsoids (MVEE) method from raw PMU observations and (b) a Bayesian framework of changepoint detection. The validity of the proposed methodology is discussed through numerical experiments on real-world utility-scale PMU data.

Hossain, Ramij Raja↗

TU-EF-304-09: Quantifying the Biological Effects of Therapeutic Protons by LET Spectrum Analysis

Purpose: To correlate in vitro cell kill with linear energy transfer (LET) spectra using Monte Carlo simulations and knowledge obtained from previous high-throughput in vitro proton relative biological effectiveness (RBE) measurements. Methods: The Monte Carlo simulation toolkit Geant4 was used to design the experimental setups and perform the dose, dose-averaged LET, and LET spectra calculations. The clonogenic assay was performed using the H460 lung cancer cell line in standard 6-well plates. Using two different experimental setups, the same dose and dose-averaged LET (12.6 keV/µm) was delivered to the cell layer; however, each respective energy or LET spectrum was different. We quantified the dose contributions from high-LET (≥10 keV/µm, threshold determined by previous RBE measurements) events in the LET spectra separately for these two setups as 39% and 53%. 8 dose levels with 1 Gy increments were delivered. The photon reference irradiation was performed using 6 MV x-rays from a LINAC. Results: The survival curves showed that both proton irradiations demonstrated an increased RBE compared to the reference photon irradiation. Within the proton-irradiated cells, the setup with 53% dose contribution from high-LET events exhibited the higher biological effectiveness. Conclusion: The experimental results indicate that the dose-averaged LET may not be an appropriate indicator to quantify the biological effects of protons when the LET spectrum is broad enough to contain both low- and high-LET events. Incorporating the LET spectrum distribution into robust intensity-modulated proton therapy optimization planning may provide more accurate biological dose distribution than using the dose-averaged LET. NIH Program Project Grant 2U19CA021239-35.

60 APPLIED LIFE SCIENCES↗

Dynamic Contingency Analysis Tool 2.0 User Manual with Test System Examples

This document introduces Version 2 of the Dynamic Contingency Analysis Tool (DCAT) software package developed by Pacific Northwest National Laboratory and serves as a guide for using this package to conduct cascading failure simulations for the electric power system. The DCAT is an open-platform and publicly available software; it is intended to help develop applications that aim to improve the capabilities of power system planning engineers to assess the impact and likelihood of extreme contingencies and potential cascading events across their systems and interconnections. Outputs from the DCAT will support finding mitigating actions to reduce the risk of cascading outages in technically sound and effective ways. This manual provides detailed instructions on how to use this tool on multicore Windows workstations or servers. In the public version of DCAT, several improvements have been made over the previous version: (1) it was modularized; (2) a graphical user interface (GUI) was developed; (3) a new version of the MPjobs parallel processing module was incorporated; and (4) a batch-processing function was added. The features of the DCAT GUI are described, including some examples of how to use the GUI to perform simulations. A full explanation of the DCAT methodology is available in the Phase 1 report.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Develop a weather-aware climate model to understand and predict extremes and associated power outages and renewable energy shortages with uncertainty-aware and physics-informed machine learning

Focal Area(s): The focus area is predictive modeling through the use of AI techniques and AI-derived model components with a particular emphasis on extreme weather in Atmospheric Science and power outages and shortages in Energy Science. Science Challenge: Predicting weather extremes (e.g., heavy precipitation, strong wind, and large hailstones), and weather-related power system outages and shortages can mitigate economic losses, save lives, support renewables integration, and improve power system resiliency. However, currently, the poor reliability and large uncertainty associated with the weather extreme prediction in the current climate models make the problem intractable. The key challenges are: (1) physical factors like green-house gases (GHGs), aerosols, and land use and land cover (LULC) can significantly impact extreme storms, but the understanding of these impacts is limited, particularly globally; (2) the convective permitting resolutions needed to model severe convective storms and their impacts are computationally prohibitive with global climate models (GCMs); (3) interactions between weather extremes and power system outages are complex and subject to great uncertainty. Current outage prediction models are short lead (~ 3 days), which do not allow for long-time planning of energy production and distribution. Moreover, we have limited capacity to predict weather events leading to sustained shortages in a renewable-energy-dominated power system. These challenges drive motivation for mechanistic understanding and reliable and efficient predictive modeling of extremes and their impacts from the sub-seasonal to long term projections.

54 ENVIRONMENTAL SCIENCES↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radar Studies of Convective Dynamics (CONVECT) Field Campaign Report

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s third ARM Mobile Facility (AMF3)-Bankhead National Forest (BNF) field deployment site and surrounding region offer a significant advantage for convective cloud studies. The higher mid-tropospheric humidity promotes frequent clouds, and when coupled with seasonal variability in convective environments, promotes isolated convection and severe thunderstorms, organized convection in the summertime, and strongly sheared convection during transitional seasons. The CONVECT field experiment was designed to provide unique, high-spatiotemporal-resolution microphysical and dynamical observations of severe weather events. The CONVECT scientific objectives align well with the AMF3-BNF site science plan.

54 ENVIRONMENTAL SCIENCES↗