Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dislocation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

754 records · Page 42

Advanced Materials for the Lunar Surface: Multiscale Computational Design of Refractory Alloys and Carbides

Emerging operational environments, such as the lunar surface, present novel challenges for NASA and drive the need for advanced materials in applications like fission surface power systems. To address these demands, computational materials science is rapidly evolving to augment or replace costly and hazardous empirical testing. Although materials selection at NASA remains predominantly experimentally driven, advanced simulation methodologies are being steadily integrated into the engineering lifecycle. This work details the application of multiscale simulation techniques—including first-principles calculations, CALPHAD, dislocation dynamics, and molecular dynamics—at NASA's Ames Research Center to evaluate advanced materials for extreme environments. First, we present contributions to the Space Nuclear Propulsion Project. Be-cause propellant channel coatings in nuclear thermal rockets must withstand high-pressure, high-temperature hydro-gen, optimizing these materials is critical. First-principles calculations were employed to establish a rigorous quantitative and qualitative understanding of the behavior of the refractory carbides ZrC, NbC, and their mixtures in high-enthalpy hydrogen environments. This necessitated the generation of high-fidelity thermodynamic models for both stoichiometric and carbon-depleted carbides, both with and without the presence of hydrogen. Furthermore, we highlight efforts under the Refractory Alloy Additive Manufacturing Build Optimization (RAAMBO) project, where existing and novel alloy compositions were assessed for additive manufacturing printability and subsequent performance in applications such as heat pipes and rocket nozzle extensions. This was accomplished through a comprehensive multiscale simulation framework that bridged the gap from the nanometer to the millimeter scale. Across both initiatives, rigorous validation against empirical data was prioritized. By systematically employing a verified and validated computational frame-work, we demonstrate how simulation effectively supports multidisciplinary engineering efforts, builds project-wide confidence, and drives critical materials development.

computational materials↗

Radiation-Resistant Ti/BN Coatings: Insights From 171 Days Exposure to Space Radiation and Atomic Oxygen in Low Orbit

Atmospheric Plasma Spray (APS) and Vacuum Plasma Spray (VPS) techniques were used to develop Ti/2 vol.% hBN coatings, for extreme space environments and tested aboard the International Space Station as part of the MISSE-17 (Materials International Space Station Experiments) program. The coatings were exposed to atomic oxygen, space radiation, and low-orbit thermal cycling. VPS coatings showed a 56% increase in microhardness, a 26% rise in elastic modulus, minimal porosity and crack density changes compared to APS coatings. The change in mechanical properties is attributed to the formation of TiO, TiO₂ and TiN from nitrogen retention, alongside radiation-induced dislocations, which enhanced surface hardening. The oxidation of titanium led to the formation of TiO and TiO₂, while boron nitride was retained and underwent transmutation in VPS coatings. XPS and EDS analyses confirmed the enhanced space-environment resistance of VPS coatings, making them ideal for long-term spacecraft protection in lunar and Martian conditions.

Abhijith Kunneparambil Sukumaran↗

Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

Review↗