Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct Conversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

TU-EF-207-03: Advances in Stationary Breast Tomosynthesis Using Distributed X-Ray Sources

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-04: Advances in Detector Technology for Breast Tomosynthesis

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-05: Dedicated Cone-beam Breast CT

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

Enhancing Direct Electrochemical CO 2 Electrolysis by Introducing A-Site Deficiency for the Dual-Phase Pr(Ca)Fe(Ni)O 3-δ Cathode

High-temperature CO 2 electrolysis via solid oxide electrolysis cells (CO 2 –SOECs) has drawn special attention due to the high energy convention efficiency, fast electrode kinetics, and great potential in carbon cycling. However, the development of cathode materials with high catalytic activity and chemical stability for pure CO 2 electrolysis is still a great challenge. In this work, A-site cation deficient dual-phase material, namely (Pr 0.4 Ca 0.6 ) x Fe 0.8 Ni 0.2 O 3-δ (PCFN, x = 1, 0.95, and 0.9), has been designed as the fuel electrode for a pure CO 2 –SOEC, which presents superior electrochemical performance. Among all these compositions, (Pr 0.4 Ca 0.6 ) 0.95 Fe 0.8 Ni 0.2 O 3-δ (PCFN95) exhibited the lowest polarization resistance of 0.458 Ω cm 2 at open-circuit voltage and 800 °C. The application of PCFN95 as the cathode in a single cell yields an impressive electrolysis current density of 1.76 A cm -2 at 1.5 V and 800 °C, which is 76% higher than that of single cells with stoichiometric Pr 0.4 Ca 0.6 Fe 0.8 Ni 0.2 O 3-δ (PCFN100) cathode. The effects of A-site deficiency on materials' phase structure and physicochemical properties are also systematically investigated. Such an enhancement in electrochemical performance is attributed to the promotion of effective CO 2 adsorption, as well as the improved electrode kinetics resulting from the A-site deficiency.

30 DIRECT ENERGY CONVERSION↗

Direct glycerol fuel cell with polytetrafluoroethylene (PTFE) thin film separator

Here, anion-exchange membrane-based direct glycerol fuel cells (AEM-DGFCs) can yield high power density, however challenges exist in developing chemically stable AEMs. Here, we demonstrate a porous PTFE thin film, a well-known chemical, electro-chemical, and thermal robust material that can serve as a separator between anode and cathode, thus achieving high DGFC’s performance. A simple aqueous-phase reduction method was used to prepare carbon nanotube supported PdAg nanoparticles (PdAg/CNT) with an average particle size of 2.9 nm. A DGFC using a PTFE thin film without any further modification with PdAg/CNT anode catalyst exhibits a peak power density of 214.7 mW cm –2 at 80 °C, about 22.6% lower than a DGFC using a state-of-the-art AEM. We report a 5.8% decrease and 11.1% decrease in cell voltage for a PTFE thin film and AEM; similarly, the cell voltage degradation rate decreases from 1.2 to 0.8 mV h –1 for PTFE thin film, while for AEM, it decreases from 9.6 to 3.0 mV h –1 over an 80 h durability test period. Transmission electron microscopy results indicate that the average particle size of PdAg/CNT increases from 2.9 to 3.7 nm after 80 h discharge; this suggests that PdAg particle growth may be the main reason for the performance drop.

30 DIRECT ENERGY CONVERSION↗

Structural analysis of sonochemically prepared PtRu versus Johnson Matthey PtRu in operating direct methanol fuel cells

Sonochemically prepared PtRu (3 : 1) and Johnson Matthey PtRu (1 : 1) were analyzed by X-ray absorption spectroscopy in operating liquid feed direct methanol fuel cells. The total metal loadings were 4 mg cm{sup -2} unsupported catalysts at the anode and cathode of the membrane electrode assembly. Ex situ XRD lattice parameter analysis indicates partial segregation of the Ru from the PtRu fcc alloy in both catalysts. A comparison of the in situ DMFC EXAFS to that of the as-received catalyst shows that catalyst restructuring during DMFC operation increases the total metal coordination numbers. A combined analysis of XRD determined grain sizes and lattice parameters, ex situ and in situ EXAFS analysis, and XRF of the as-received catalysts enables determination of the catalyst shell composition. The multi-spectrum analysis shows that the core size increases during DMFC operation by reduction of Pt oxides and incorporation of Pt into the core. This increases the mole fraction of Ru in the catalyst shell structure.

30 DIRECT ENERGY CONVERSION↗

Accelerating Additive Manufacturing Process Design for Energy Conversion Materials using In-situ Sensing and Machine Learning

One promising candidate for manufacturing of the bismuth Telluride thermoelectric legs is laser powder bed fusion (LPBF) additive Manufacturing (AM). AM processing parameters highly influence the material properties, however current processing parameter development methods in AM are costly and time consuming. In-situ sensors allow for the capture of physically relevant process information on a layer-by-layer basis and will be used to aide process development. To optimize the AM process for the best thermoelectric performance, process variables, in-situ process sensor data and ex-situ material characterization data are collected. Several different interpretable machine learning (ML) approaches are used, and the performance of each method are assessed. Significant input process variables include laser focus, hatch spacing and laser power. The best performing models are used to determine the manufacturing parameters that maximize the power factor. AM of bismuth telluride material provides the ability to create complex geometries enabling more efficient energy conversion.

30 DIRECT ENERGY CONVERSION↗

Palladium and Tin Alloyed Catalysts for the Ethanol Oxidation Reaction in an Alkaline Medium

In this paper, we present a study of a series of carbon-supported Pd-Sn binary alloyed catalysts prepared through a modified Polyol method as anode electrocatalysts for direct ethanol fuel cell reactions in an alkaline medium. Transmission electron microscopy, energy-dispersive X-ray spectroscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and aberration-corrected scanning transmission electron microscopy equipped with electron energy loss spectroscopy were used to characterize the Pd-Sn/C catalysts, where homogeneous Pd-Sn alloys were determined to be present with the surface Sn being partially oxidized. Among various Pd-Sn catalysts, Pd{sub 86}Sn{sub 14}/C catalysts showed much enhanced current densities in cyclic voltammetric and chronoamperometric measurements, compared to commercial Pd/C (Johnson Matthey). The overall rate law of ethanol oxidation reaction for both Pd{sub 86}Sn{sub 14}/C and commercial Pd/C were also determined, which clearly showed that Pd{sub 86}Sn{sub 14}/C was more favorable in high ethanol concentration and/or high pH environment. Density functional theory calculations also confirmed Pd-Sn alloy structures would result in lower reaction energies for the dehydrogenation of ethanol, compared to the pure Pd crystal.

30 DIRECT ENERGY CONVERSION↗

System and method for single-phase, single-stage grid-interactive inverter

The present invention provides for the integration of distributed renewable energy sources/storages utilizing a cascaded DC-AC inverter, thereby eliminating the need for a DC-DC converter. The ability to segment the energy sources and energy storages improves the maintenance capability and system reliability of the distributed generation system, as well as achieve wide range reactive power compensation. In the absence of a DC-DC converter, single stage energy conversion can be achieved to enhance energy conversion efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Additive Manufacturing: A New Paradigm for the Next Generation of High-Power-Density Direct-Drive Electric Generators: Preprint

In recent years, there has been a growing demand for high-power-density direct-drive generators in the wind industry owing to their high reliability, torque per-unit volume, and conversion efficiencies. However, direct-drive wind turbine generators are very large, low-speed electric machines, which pose remarkable design and manufacturing issues that challenge their upscaling potential and cost of implementation. With air-gap tolerance as the main design driver, the need for high stiffness shifts the focus toward support-structure design that forms a significant portion of the generator's total mass. Existing manufacturing processes allow the use of segmented-steel-weldment disk or spoke-arm assemblies that yield stiffer structures per unit mass but tend to be heavier and more expensive to build. As a result, there is a need for a transformative approach to realize lightweight designs that can also facilitate series production at competitive costs. Inspired by recent developments in metal additive manufacturing (AM), we explore a new freedom in the structural design space with a high potential for weight savings in direct-drive generators. This includes the feasibility of using nonconventional complex geometries, such as lattice-based structures as structurally efficient options. Powder-binder jetting of a sand-cast mold was identified as the most feasible AM technology to produce large-scale generator rotor structures with complex geometry. A parametric optimization study was performed and optimized results within deformation and mass constraints were found for each design. The response to the maximum Maxwell stress due to unbalanced magnetic pull was also explored for each design. Further, a topology optimization was applied for each parameter-optimized design to validate results and provide insights into further mass reduction. These novel designs catered for AM are compared in both deflection and mass to conventional rotor designs using NREL's systems engineering design tool, GeneratorSE. The optimized lattice design with a Ubeam truss resulted in a 24% reduction in structural mass of the rotor and 60% reduction in radial deflection. It is demonstrated that additive manufacturing shifts the focus from manufacturability constraints toward lower mass.

17 WIND ENERGY↗

An efficient construction of nano-interfaces for excellent coking tolerance of cermet anodes

Solid oxide fuel cells (SOFCs) are promising energy conversion devices for the effective and convenient utilization of hydrocarbons (for example, methane) to electricity. However, the development of direct methane SOFCs is primarily hindered by the poor coking tolerance of the state-of-the-art Ni-based cermet anodes. Herein, we efficiently construct nano-interfaces in the anode by infiltrating a Ni 0.6 Y 0.064 Zr 0.336 O 2-δ (NYZ) catalyst onto the traditional Ni-based cermet anode to effectively enhance the coking tolerance. After being reduced in H 2 , Ni and Y 0.16 Zr 0.84 O 2-δ (YSZ) nanoparticles (NPs) are in situ formed on the surface of the Ni-YSZ substrate. The roughened anode demonstrates significantly improved fuel oxidation activity and coking tolerance, due likely to the formation of nano-interfaces. Specifically, when applied in the Ni-YSZ-based anode-supported SOFCs, a high peak power density of 1.785 W cm –2 and a stable operation of ~ 240 h with no observable degradation is achieved at 750 °C in nearly dry methane (3% H 2 O). Finally, a density functional theory study suggests that the excellent coking tolerance is attributed to the formation of OH species on Ni/YSZ nano-interfaces, which would further interact with intermediate carbon species to generate COH intermediates.

30 DIRECT ENERGY CONVERSION↗

Fabrication and characterization of P3HT:PCBM-based thin film organic solar cells with zinc phthalocyanine

[6,6]–phenyl C{sub 61}–butyric acid methyl ester and poly(3–hexylthiophene) bulk heterojunction solar cells added with zinc–tetra–tertiary–butyl–phthalocyanine (ZnPc) were fabricated and characterized. The photovoltaic properties of the solar cells with an inverted structure were improved by the ZnPc addition, which were investigated on the bases of current density–voltage characteristics, incident photon to current conversion efficiency.

30 DIRECT ENERGY CONVERSION↗

Underpotential deposition-mediated layer-by-layer growth of thin films

A method of depositing contiguous, conformal submonolayer-to-multilayer thin films with atomic-level control is described. The process involves the use of underpotential deposition of a first element to mediate the growth of a second material by overpotential deposition. Deposition occurs between a potential positive to the bulk deposition potential for the mediating element where a full monolayer of mediating element forms, and a potential which is less than, or only slightly greater than, the bulk deposition potential of the material to be deposited. By cycling the applied voltage between the bulk deposition potential for the mediating element and the material to be deposited, repeated desorption/adsorption of the mediating element during each potential cycle can be used to precisely control film growth on a layer-by-layer basis. This process is especially suitable for the formation of a catalytically active layer on core-shell particles for use in energy conversion devices such as fuel cells.

30 DIRECT ENERGY CONVERSION↗

Revealing the Electrochemical Kinetics of Electrolytes in Nanosized LiFePO 4 Electrodes

Lithium-ion battery rate performance is ultimately limited by the electrolyte, yet the behaviors of electrolytes during high-rate (dis)charge remain elusive to electrochemical measurement. Herein, we develop and study a nanosized LiFePO 4 model system in which the electrolyte completely controls the electrochemical kinetics of the porous electrode. Impedance spectroscopy, cyclic voltammetry, and rate performance testing prove that ion transport in the electrolyte is the sole rate-limiting process, even in thin electrodes. A novel pseudo-steady-state extrapolation (S3E) method for Tafel analysis shows that LiFePO 4 obeys Butler-Volmer kinetics with a transfer coefficient of 3. The combination of these unexpectedly rapid interfacial kinetics and an activation barrier for phase transformation causes extreme reaction heterogeneity, which manifests as a moving reaction zone. Resistance versus capacity analysis enables direct measurement of electrolyte resistance growth during high-rate (dis)charge, revealing how the interaction between concentration polarization and a moving reaction zone controls electrolyte rate performance in LiFePO 4 electrodes. This work elucidates the profound impacts of the electrolyte on electrochemical measurements in porous battery electrodes: when the active material is not rate limiting, it is impossible to directly measure the intrinsic kinetics of the active material, but conversely, it becomes possible to directly measure the kinetics of the electrolyte.

Electrochemistry↗

SHAPE SELECTIVE NANO-CATALYSTS: TOWARD DIRECT METHANOL FUEL CELLS APPLICATIONS

A series of bimetallic core-shell-alloy type Au-Pt nanomaterials with various morphologies, aspect ratios and compositions, were produced in a heterogenous epitaxial fashion. Gold nanoparticles with well-controlled particle size and shape, e.g. spheres, rods and cubes, were used as 'seeds' for platinum growth in the presence of a mild reducing agent, ascorbic acid and a cationic surfactant cethyltrimethyl ammonium bromide (CTAB). The reactions take place in air and water, and are quick, economical and amenable for scaling up. The synthesized nanocatalysts were characterized by electron microscopy techniques and energy dispersive X-ray analysis. Nafion membranes were embedded with the Au-Pt nanomaterials and analyzed by atomic force microscopy (AFM) and scanning electron microscopy (SEM) for their potential in direct methanol fuel cells applications.

30 DIRECT ENERGY CONVERSION↗