Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Conference Comments by the Editors

The Symposium on Radiation Measurements and Applications (SORMA) met for the first time on the West Coast June 2-5, 2008, in Berkeley, CA. With radiation detectors increasing in number, variety, and societal importance, we plan to alternate between SORMA East (in Ann Arbor, MI) and SORMA West so that the forum will be available every two years. The topic areas for SORMA West 2008 were much the same as those of recent Ann Arbor programs, and were meant to encompass the full breadth of ionizing radiation measurement applications and technologies, with both oral and poster presentations. The technical program of SORMA 2008 included 342 scientific presentations, 116 oral presentations plus eight invited keynote lectures in plenary sessions, as well as 218 presentations in poster sessions. The SORMA 2008 meetings were attended by 439 registered participants from 25 different countries. Topics of interest at the meeting ranged from room temperature semiconductor detectors, cryogenic detectors, photodetectors, neutron detectors, novel scintillators, nonproportionality and characterization of scintillators, simulation and analysis of radiation interactions, novel radiation sources, imaging technologies and homeland security and medical applications. This was the first conference of the SORMA series to be technically cosponsored by the Institute of Electrical and Electronic Engineers (IEEE), specifically by the Nuclear and Plasma Sciences Society (NPSS) of IEEE. The co-sponsorship has been important for visibility of SORMA and for attracting a record number of new participants. This special issue of IEEE TRANSACTIONS ON NUCLEAR SCIENCE comprises the refereed proceedings of SORMA 2008, containing 128 papers on the research presentations. The Chairs of the SORMA 2008 conference would like to acknowledge partial financial support from the NNSA, DNDO, and DTRA, and organizational support from Lawrence Berkeley National Laboratory and Lawrence Livermore National Laboratory. We acknowledge our corporate supporters: Caen Nuclear, Eljen Technology, Hilger Crystals and GE Global Research. Finally, we thank the members of the local organizing committee: Diana Attila, Thomas Budinger, Joe Chew, Daniel Chivers, Rob Johnson, Laurie O'Brien, Donna Raziano, Emily Sause, and Brian Wirth for doing all the work that actually made this conference happen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation Studies Of Photon Signal Reconstruction In The DUNE Single Phase Far Detector With Xe Doping

Xenon when doped to argon has the potential to increase the effectiveness of scintillation systems in liquid argon time projection chambers (LArTPC). To test the potential improvements, a simulation study was conducted. A simulation of light going through liquid Argon and Xenon photon libraries (photon libraries are used to reduce the amount of computational power needed for interactions that produce a large amount of photons), comparing differences in their properties. The study found more light being emitted in a shorter time by Xe than by Ar with less attenuation present. Preliminary results show lower efficiency of Ar at closer distances. It's unclear whether this is due to inherit properties of the Xe or a result of selection cuts not being optimized. These potential improvements are being looked into for future neutrino experiments such as the Deep Underground Neutrino Experiment (DUNE).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low energy neutrino detection with a compact water-based liquid scintillator detector

In this study, the conceptual design and physics simulations of a near-field Water-based Liquid Scintillator (WbLS) detector placed 100 m from the Akkuyu Nuclear Power Plant (ANPP), currently under construction and aiming at being Turkey’s first nuclear power plant, is presented. The ANPP is an excellent opportunity for neutrino studies and the development of an R &D program for neutrino detectors in Turkey. The Reactor Neutrino Experiments of Turkey (RNET) program includes a compact detector with a 2.5-ton volume of WbLS and a ~ 30% photo-coverage, and the program is planned to be expanded with a medium-size 30-ton detector that will be an international testbed for WbLS and new detector technologies through low energy neutrino studies. In the following, the focus will be on the smaller ~2.5 ton detector, instrumented with 8-in. high quantum efficiency PMTs and two layers of cosmic veto paddles, covering all sides of the detector, to track and veto cosmic particles. Inverse Beta Decay (IBD) events from electron anti-neutrinos generated in the reactor core are simulated using the RAT-PAC simulation package and several liquids with different percentages of Liquid Scintillator (LS) and Gadolinium (Gd) are investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution DEPFET active pixel sensors for the Belle II experiment

The new Belle II experiment at the SuperKEKB collider at KEK was launched in 2009 as a general upgrade of the previous successful Belle experiment. Important improvements in the Belle II detector are additional two pixel layers forming the innermost part of the vertex detector. This paper gives a short overview of the expected impact of the two inner pixel layers on the performance of Belle II based on simulations and current experimental knowledge of the DEPFET pixel detectors. The focus is on the expected performance of the thinned DEPFET pixel sensors in Belle II in terms of spatial resolution. The measurements and simulations of the current generation of DEPFET sensors in beam tests indicate that the design resolution requirements can be met. The dependence of the spatial resolution on the deposited energy was observed in beam tests and we simulated the effect for the Belle II detector type to estimate its magnitude. A short description of the readout and data acquisition chain of the Belle II pixel vertex detector is given. (authors)

43 PARTICLE ACCELERATORS↗

SU-F-T-657: In-Room Neutron Dose From High Energy Photon Beams

Purpose: To estimate neutron dose inside the treatment room from photodisintegration events in high energy photon beams using Monte Carlo simulations and experimental measurements. Methods: The Monte Carlo code MCNP6 was used for the simulations. An Eberline ESP-1 Smart Portable Neutron Detector was used to measure neutron dose. A water phantom was centered at isocenter on the treatment couch, and the detector was placed near the phantom. A Varian 2100EX linear accelerator delivered an 18MV open field photon beam to the phantom at 400MU/min, and a camera captured the detector readings. The experimental setup was modeled in the Monte Carlo simulation. The source was modeled for two extreme cases: a) hemispherical photon source emitting from the target and b) cone source with an angle of the primary collimator cone. The model includes the target, primary collimator, flattening filter, secondary collimators, water phantom, detector and concrete walls. Energy deposition tallies were measured for neutrons in the detector and for photons at the center of the phantom. Results: For an 18MV beam with an open 10cm by 10cm field and the gantry at 180°, the Monte Carlo simulations predict the neutron dose in the detector to be 0.11% of the photon dose in the water phantom for case a) and 0.01% for case b). The measured neutron dose is 0.04% of the photon dose. Considering the range of neutron dose predicted by Monte Carlo simulations, the calculated results are in good agreement with measurements. Conclusion: We calculated in-room neutron dose by using Monte Carlo techniques, and the predicted neutron dose is confirmed by experimental measurements. If we remodel the source as an electron beam hitting the target for a more accurate representation of the bremsstrahlung fluence, it is feasible that the Monte Carlo simulations can be used to help in shielding designs.

60 APPLIED LIFE SCIENCES↗

SNM Detection with an Optimized Water Cherenkov Neutron Detector

Special Nuclear Material (SNM) can either spontaneously fission or be induced to do so: either case results in neutron emission. For this reason, neutron detection performs a crucial role in the functionality of Radiation Portal Monitoring (RPM) devices. Since neutrons are highly penetrating and difficult to shield, they could potentially be detected escaping even a well-shielded cargo container. If the shielding were sophisticated, detecting escaping neutrons would require a highly efficient detector with close to full solid angle coverage. In 2008, we reported the successful detection of neutrons with a 250 liter (l) gadolinium doped water Cherenkov prototype—a technology that could potentially be employed cost effectively with full solid angle coverage. More recently we have built and tested both 1-kl and 3.5-kl versions, demonstrating that very large, cost effective, non-flammable and environmentally benign neutron detectors can be operated efficiently without being overwhelmed by background. In our paper, we present a new design for a modular system of water-based neutron detectors that could be deployed as a real RPM. The modules contain a number of optimizations that have not previously been combined within a single system. We present simulations of the new system, based on the performance of our previous detectors. These simulations indicate that an optimized system such as is presented here could achieve SNM sensitivity competitive with a large 3 He-based system. Moreover, the realization of large, cost effective neutron detectors could, for the first time, enable the detection of multiple neutrons per fission from within a large object such as a cargo container. Such a signal would provide a robust indication of the presence of fissioning material, reducing the frequency of false alarms while increasing sensitivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterizing the radiation response of Cherenkov glass detectors with isotopic sources

Abstract Cherenkov detectors are widely used for particle identification and threshold detectors in high-energy physics. Glass Cherenkov detectors that are sensitive to beta emissions originating from neutron activation have been demonstrated recently as a potential replacement for activation foils. In this work, we set the groundwork to evaluate large Cherenkov glass detectors for sensitivity to MeV photons through first understanding the measured response of small Cherenkov glass detectors to isotopic gamma-ray sources. Counting and pulse height measurements are acquired with reflected glass Cherenkov detectors read out with a photomultiplier tube. Simulation was used to inform our understanding of the measured results. This simulation included radioactive source decay, radiation interaction, Cherenkov light generation, optical ray tracing, and photoelectron production. Implications for the use of Cherenkov glass detectors to measure low energy gammaray response are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bayesian comparison of post-Newtonian approximations of gravitational wave chirp signals

We estimate the probability of detecting a gravitational wave signal from coalescing compact binaries in simulated data from a ground-based interferometer detector of gravitational radiation using Bayesian model selection. The simulated wave form of the chirp signal is assumed to be a spinless post-Newtonian (PN) wave form of a given expansion order, while the searching template is assumed to be either of the same post-Newtonian family as the simulated signal or one level below its post-Newtonian expansion order. Within the Bayesian framework, and by applying a reversible jump Markov Chain Monte Carlo simulation algorithm, we compare PN1.5 vs PN2.0 and PN3.0 vs PN3.5 wave forms by deriving the detection probabilities, the statistical uncertainties due to noise as a function of the signal-to-noise ratio, and the posterior distributions of the parameters. Our analysis indicates that the detection probabilities are not compromised when simplified models are used for the comparison, while the accuracies in the determination of the parameters characterizing these signals can be significantly worsened, no matter what the considered post-Newtonian order expansion comparison is.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COMPARISON OF PIONEER 10, VOYAGER 1, AND VOYAGER 2 ULTRAVIOLET OBSERVATIONS WITH ANTI-SOLAR LYMAN-ALPHA BACKSCATTER SIMULATIONS

Observations made by ultraviolet (UV) detectors on board Pioneer 10, Voyager 1, and Voyager 2 can be used to analyze the distribution of neutral hydrogen throughout the heliosphere, including the interaction regions of the solar wind and local interstellar medium. Previous studies of the long-term trend of decreasing intensity with increasing heliocentric distance established the need for more sophisticated heliospheric models. Here we use state-of-the-art three-dimensional (3D) magnetohydrodynamic (MHD) neutral models to simulate Lyman-alpha backscatter as would be seen by the three spacecrafts, exploiting a new 3D Monte Carlo radiative transfer code under solar minimum conditions. Both observations and simulations of the UV backscatter intensity are normalized for each spacecraft flight path at {approx}15 AU, and we focus on the slope of decreasing intensity over an increasing heliocentric distance. Comparisons of simulations with Voyager 1 Lyman-alpha data results in a very close match, while the Pioneer 10 comparison is similar due to normalization, but not considered to be in agreement. The deviations may be influenced by a low resolution of photoionization in the 3D MHD-neutral model, a lack of solar cycle activity in our simulations, and possibly issues with instrumental sensitivity. Comparing the slope of Voyager 2 and the simulated intensities yields an almost identical match. Our results predict a large increase in the Lyman-alpha intensity as the hydrogen wall is approached, which would signal an imminent crossing of the heliopause.

79 ASTRONOMY AND ASTROPHYSICS↗

Applying the Kalman filter particle method to strange and open charm hadron reconstruction in the STAR experiment

Here, we apply KF Particle, a Kalman Filter package for secondary vertex finding and fitting, to strange and open charm hadron reconstruction in heavy-ion collisions in the STAR experiment. Compared to the conventional helix swimming method used in STAR, the KF Particle method improves the reconstructed Λ, Ω and $D$ 0 significance considerably. At the same time, we demonstrate that Monte Carlo simulation with the STAR detector responses can well reproduce the topological variable distributions reconstructed in real data using the KF Particle method, therefore retaining good control on the reconstruction efficiency uncertainties for strange and open charm hadrons measurements in heavy-ion collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Super-resolution model for overlapping peak detection and improved spatial resolution in high-energy diffraction microscopy

Reconstruction quality in Far-field High-Energy Diffraction Microscopy (FF-HEDM) is limited by the spatial resolution of area detectors and the frequent occurrence of overlapping diffraction spots. To address these challenges, we developed a super-resolution (SR) framework using convolutional neural networks (CNNs) to recreate 2D diffraction peaks at up to ×8 resolution from raw detector data. A specialized simulation tool was created to generate synthetic training datasets with varying degrees of peak overlap. Integrated into the Microstructural Imaging using Diffraction Analysis Software (MIDAS), the SR model improves the spatial accuracy and precision of 3D grain reconstruction by an order of magnitude. This approach provides a robust solution for investigation of complex micromechanical states and material classes where the analysis is limited by the presence of overlapping peaks. Furthermore, the methodology developed here can potentially be extended to other techniques that require sub-pixel accuracy for high-fidelity data analysis.

High-energy diffraction microscopy↗

A New Mass Reconstruction Technique for Resonances Decaying to di-tau

Accurate reconstruction of the mass of a resonance decaying to a pair of $\tau$ leptons is challenging because of the presence of multiple neutrinos from $\tau$ decays. The existing methods rely on either a partially reconstructed mass, which has a broad spectrum that reduces sensitivity, or the collinear approximation, which is applicable only to the relatively small fraction of events. We describe a new technique, which provides an accurate mass reconstruction of the original resonance and does not suffer from the limitations of the collinear approximation. The major improvement comes from replacing assumptions of the collinear approximation by a requirement that mutual orientations of the neutrinos and other decay products are consistent with the mass and decay kinematics of a $\tau$ lepton. This is achieved by minimizing a likelihood function defined in the kinematically allowed phase space region. In this paper we describe the technique and illustrate its performance using $Z/\gamma^{*}\to\tau\tau$ and $H\to\tau\tau$ events simulated with the realistic detector resolution. The method is also tested on a clean sample of data $Z/\gamma^{*}\to\tau\tau$ events collected by the CDF experiment at the Tevatron. We expect that this new technique will allow for a major improvement in searches for the Higgs boson at both the LHC and the Tevatron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SimELIT: A Novel GUI-Based Comprehensive Ion Trajectory Simulation Software for Mass Spectrometry

Ion trajectory simulation in mass spectrometry systems from injection to detection is technically challenging but very important for better understanding the ion dynamics in instrument development. Here, in this work, we present SimELIT (Simulator of Eulerian and Lagrangian Ion Trajectories), a novel ion trajectory simulation platform. SimELIT is built upon a suite of multiphysics solvers compiled into OpenFOAM (an open-source numerical solver library particularly used for computational mechanics), with a simple web-based graphical user interface (GUI) allowing users to define the details of OpenFOAM cases and run simulations. SimELIT is a modular program and can provide extensions of physics (e.g., gas flows, electrodynamic fields) and thus enable ion trajectory simulations from the ion source to detector. The current version (SimELIT) provides two numerical solvers for ion trajectory simulations–(1) a Lagrangian particle tracker in vacuum and (2) a Eulerian ion density solver in background gas in the presence of electric fields. Here, we describe the architecture of SimELIT, including its use of Docker and the React Framework, and demonstrate the computation of ion trajectories of multiple m/z values in a static/linear voltage drop in vacuum (across a 1 m long flight tube). Further, the drift motion of ions under 1 Torr pressure conditions in a static background (N 2 ) gas through a 20 V/cm static electric field is shown. The results produced from SimELIT were compared with SIMION and theoretical estimates. In addition, we report the computation of ion trajectories in electrodynamic fields within a planar FAIMS device operating at atmospheric pressure.

97 MATHEMATICS AND COMPUTING↗

Studies of Muon-Induced Radioactivity at NuMI

The JASMIN Collaboration has studied the production of radionuclides by muons in the muon alcoves of the NuMI beamline at Fermilab. Samples of aluminum and copper are exposed to the muon field and counted on HPGe detectors when removed to determine their content of radioactive isotopes. We compare the results to MARS simulations and discuss the radiological implications for neutrino factories and muon colliders.

07 ISOTOPE AND RADIATION SOURCES↗

Transient and steady-state dark current mechanisms in amorphous selenium avalanche radiation detectors

A theoretical model for describing bias-dependent transient and steady-state behaviors of dark current in amorphous selenium (a-Se) avalanche detector structures has been developed. The analytical model considers bulk thermal generation current from mid-gap sates, transient carrier depletion, and carrier injection from the electrodes incorporating avalanche multiplication. The proposed physics-based dark current model is compared with the published experimental results on three potential a-Se avalanche detector structures. The steady-state dark current is the minimum for the structures that have effective blocking layers for both holes and electrons. The transient decay time to reach a plateau decreases considerably with increasing electric field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE ATACAMA COSMOLOGY TELESCOPE: DATA CHARACTERIZATION AND MAPMAKING

We present a description of the data reduction and mapmaking pipeline used for the 2008 observing season of the Atacama Cosmology Telescope (ACT). The data presented here at 148 GHz represent 12% of the 90 TB collected by ACT from 2007 to 2010. In 2008 we observed for 136 days, producing a total of 1423 hr of data (11 TB for the 148 GHz band only), with a daily average of 10.5 hr of observation. From these, 1085 hr were devoted to an 850 deg{sup 2} stripe (11.2 hr by 9. Degree-Sign 1) centered on a declination of -52. Degree-Sign 7, while 175 hr were devoted to a 280 deg{sup 2} stripe (4.5 hr by 4. Degree-Sign 8) centered at the celestial equator. The remaining 163 hr correspond to calibration runs. We discuss sources of statistical and systematic noise, calibration, telescope pointing, and data selection. For the 148 GHz band, out of 1260 survey hours and 1024 detectors in the array, 816 hr and 593 effective detectors remain after data selection, yielding a 38% survey efficiency. The total sensitivity in 2008, determined from the noise level between 5 Hz and 20 Hz in the time-ordered data stream (TOD), is 32 {mu}K{radical}s in cosmic microwave background units. Atmospheric brightness fluctuations constitute the main contaminant in the data and dominate the detector noise covariance at low frequencies in the TOD. The maps were made by solving the least-squares problem using the Preconditioned Conjugate Gradient method, incorporating the details of the detector and noise correlations. Simulations, as well as cross-correlations with Wilkinson Microwave Anisotropy Probe sky maps on large angular scales, reveal that our maps are unbiased at multipoles l > 300. This paper accompanies the public release of the 148 GHz southern stripe maps from 2008. The techniques described here will be applied to future maps and data releases.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of the DUNE photodetectors and study of the event burst phenomenon

The Deep Underground Neutrino Experiment (DUNE) is an upcoming neutrino physics experiment that will answer some of the most compelling questions in particle physics and cosmology. The DUNE far detectors employ silicon photomultipliers (SiPMs) to detect light produced by charged particles interacting in a large liquid argon time projection chamber (LArTPC). The SiPMs are photosensors consisting of an array of single-photon avalanche diodes (SPAD) operating in Geiger mode. Their high sensitivity and dynamic range, as well as the possibility to fill large surfaces with high-granularity sensors, makes them an ideal choice for DUNE. An international consortium of research groups is currently engaged in a systematic comparison of the performances of the SiPM models that have been custom developed for DUNE by two manufacturers. Such detailed studies, which include gain measurements and a structure study of the dark count rate at 77 K, are meant to determine the best choice of the photodetection system for DUNE, as well as characterize the response of the chosen detectors for the DUNE simulation. Moreover, an investigation of a newly observed phenomenon, in which quick bursts of tens of events at close range are collected in individual SiPMs, is being carried out, which potentially impacts the design of future models and their implementation in particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗