Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Curve fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Photoelectric photometry of the RS CVn binary EI Eridani = HD 26337

Differential UBV(RI)sub KC and UBVRI photometry of the RS CVn binary EI Eridani obtained during December 1987 and January 1988 at fourteen different observatories is presented. A combined visual bandpass light curve, corrected for systematic errors of different observatories, utilizes the photometric period of 1,945 days to produce useful results. The analysis shows the visual light curve to have twin maxima, separated by about 0.4 phase, and a full amplitude of approximately 0.06 mag for the period of observation, a smaller amplitude than reported in the past. The decrease in amplitude may be due to a decrease or homogenization of spot coverage. To fit the asymmetrical light curve, a starspot model would have to employ at least two spotted regions separated in longitude.

Hooten, J. T.↗

Modeling Stochastic Variability in Multiband Time-series Data

In preparation for the era of time-domain astronomy with upcoming large-scale surveys, we propose a state-space representation of a multivariate damped random walk process as a tool to analyze irregularly-spaced multifilter light curves with heteroscedastic measurement errors. We adopt a computationally efficient and scalable Kalman filtering approach to evaluate the likelihood function, leading to maximum O(k 3 n) complexity, where k is the number of available bands and n is the number of unique observation times across the k bands. This is a significant computational advantage over a commonly used univariate Gaussian process that can stack up all multiband light curves in one vector with maximum O(k 3 n 3 ) complexity. Using such efficient likelihood computation, we provide both maximum likelihood estimates and Bayesian posterior samples of the model parameters. Three numerical illustrations are presented: (i) analyzing simulated five-band light curves for a comparison with independent single-band fits; (ii) analyzing five-band light curves of a quasar obtained from the Sloan Digital Sky Survey Stripe 82 to estimate short-term variability and timescale; (iii) analyzing gravitationally lensed g- and r-band light curves of Q0957+561 to infer the time delay. Two R packages, Rdrw and timedelay, are publicly available to fit the proposed models.

79 ASTRONOMY AND ASTROPHYSICS↗

Carbon thin film thermometry

The work concerning carbon thin film thermometry is reported. Optimum film deposition parameters were sought on an empirical basis for maximum stability of the films. One hundred films were fabricated for use at the Marshall Space Flight Center; 10 of these films were given a precise quasi-continuous calibration of temperature vs. resistance with 22 intervals between 5 and 80 K using primary platinum and germanium thermometers. Sensitivity curves were established and the remaining 90 films were given a three point calibration and fitted to the established sensitivity curves. Hydrogen gas-liquid discrimination set points are given for each film.

Collier, R. S.↗

Evolution of large-scale plasma structures in comets: Kinematics and physics

Cometary and solar wind data from December 1985 through April 1986 are presented for the purpose of determining the solar wind conditions associated with comet plasma tail disconnection events (DE's). The cometary data are from The International Halley Watch Atlas of Large-Scale Phenomena (Brandt, Niedner, and Rahe, 1992). In addition, we present the kinematic analysis of 4 DE's, those of Dec. 13.5 and 31.2, 1985, and Feb. 21.7 and 28.7, 1986. The circumstances of these DE's clearly illustrate the need to analyze DE's in groups. In situ solar wind measurements from IMP-8, ICE, and PVO were used to construct the variation of solar wind speed, density, and dynamic pressure during this interval. Data from these same spacecraft plus Vega-1 were used to determine the time of 48 current sheet crossings. These data were fitted to heliospheric current sheet curves extrapolated from the corona into the heliosphere in order to determine the best-fit source surface radius for each Carrington rotation. Comparison of the solar wind conditions and 16 DE's in Halley's comet (the four DE's discussed in this paper and 12 DE's in the literature) leaves little doubt that DE's are associated primarily with crossings of the heliospheric current sheet and apparently not with any other property of the solar wind. If we assume that there is a single or primary physical mechanism and that Halley's DE's are representative, efforts at simulation should concentrate on conditions at current sheet crossings. The mechanisms consistent with this result are sunward magnetic reconnection and tailward magnetic reconnection, if tailward reconnection can be triggered by the sector boundary crossing.

Brandt, John C.↗

Calibration of CDM-Based Creep Constitutive Model Using Accelerated Creep Test (ACT) Data

In conventional creep testing (CCT) a specimen is subject to constant load and temperature for a long-duration until creep rupture occurs. Conventional testing can be costly when considering the number of experiments needed to characterize the creep response of a material over a range of stress and temperature. To predict long-term creep-rupture properties, the time-temperature-stress superposition principle (TTSSP) approach has been employed where stress and/or temperature is applied at an elevated level; the result of which are extrapolated down to low stress and/or temperature conditions. These methods have been successful in predicting minimum-creep-strain-rate (MCSR) and stress-rupture (SR) but suffer from an inability to predict the creep deformation curve or account for changes in deformation mechanisms or aging that occurs at long-duration. An accelerated technique, termed the Stepped isostress method (SSM) allows the accelerated testing of materials to determine their creep deformation response. Unlike TTSSP tests, the SSM test employs a single specimen where the stress is periodically step increased until rupture. The SSM creep deformation curve is processed (time and strain shifted) to produce an accelerated creep deformation curve that represent the creep deformation curve at the initial stress level in SSM. A processing procedure for metals has yet to be developed. The research objective of this study is to develop a processing procedure for SSM test data using a creep-damage constitutive model. Triplicate SSM tests were conducted on Ni-based superalloy Inconel 718 at 650°C with stress being periodically increased until rupture. Triplicate CCT tests were conducted at the initial stress level of the SSM tests. The Sine-hyperbolic (Sinh) creep-damage model was employed in this study. The Sinh creep-damage constitutive model is based on coupled creep strain rate and damage evolution equations; where both rates are dependent on the current state of damage. Calibration is two-step: analytical and numerical optimization. Each stepped creep deformation curve is tackled quasi-analytically to determine MCSR and SR related material constants and accumulated damage. The damage accumulated at the end of each step was then passed onto subsequent steps to calibrate the MCSR, rupture prediction, and damage evolution. Numerical optimization was applied to optimize model constants involved in the creep strain constitutive equations in order to generate best-fitted Sinh creep deformation curves. The Sinh model predictions were compared to the SSM and CCT data. The Sinh model satisfactorily predicts the SSM data and thus the calibrated material constants provides a good estimate of rupture found in the CCT data. Calibration using SSM data reduces the number of tests needed to calibrate a model; significantly reducing costs. A single SSM test replaces numerous creep tests at different stresses.

36 MATERIALS SCIENCE↗

LOFTID Heat Flux Gauge Calibration: What is Truth?

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) is a demonstration of Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which may enable the delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the size of the rocket’s shroud, inflatable aeroshells can be deployed to a much larger scale, thus allowing a spacecraft to begin its deceleration earlier and experience less heating. On LOFTID, there will be 4 total heat flux gauges (HFG) with a range of 70 W/cm2 and 1 radiometer with a range of 3 W/cm2, arranged as shown in Fig. 1. Both the radiometer and total HFGs are Schmidt-Boelter gauges purchased from an external vendor. Radiative calibrations were performed in-house at NASA Ames’ Sensors and TPS Advanced Research Laboratories (STAR Labs) before and after environmental testing to investigate how the testing affected the sensors' response. Additional rounds of radiative calibration at STAR Labs were also performed in order to investigate the large uncertainties associated with these tests. For example, a survey of multiple calibration facilities concluded that the uncertainty within a given facility was +/-3% [1]. An additional NIST study that calibrated heat flux gauges at 7 different facilities also found the variation in calibration coefficients to be up to ~3% within a given facility, but up to 15% between facilities, suggesting systematic differences between test setups [2]. Finally, the response of heat flux gauges to radiative versus convective heat flux has shown to differ by up to 20% [3],[4]. Because the heat flux gauges on LOFTID will predominantly experience convective heat flux during flight, a convective calibration study was performed at Boeing's Large-Core Arc Tunnel (LCAT) facility. Radiative Calibration Procedure The calibrations performed at STAR Labs utilize a quartz lamp bank (QLB) that provides a maximum heat flux of 50 W/cm2, which bounds the expected LOFTID flight environment. The calibration involves exposing a water-cooled Gardon gauge (reference) and then the unit-under-test (UUT) to 5 different heat fluxes multiple times for 10 seconds each, and then calculating a linear fit. The test setup is shown in Fig. 2. The total HFGs were calibrated at STAR Labs 3 times, denoted as STAR 1 (before environmental testing), STAR 2 (after protoflight vibration and thermal-vacuum testing), and STAR 3 (no change from previous test). All 8 flight-lot total HFGs showed a decrease in full-scale output from STAR 1 to STAR 2 by between 0.5% and 10. The first portion of this investigation was to determine whether the change could be due to differences in temperature between the two calibration runs. A typical linear fit to the calibration data was performed using Eq. 1 where q’ is the heat flux in W/cm2, c is the calibration coefficient, and mV is the sensor output. To account for temperature, the data were fit to a nonlinear function that included both the sensor output (mV) and the temperature from the thermocouple embedded inside the HFG near the surface (T): q'=mV/(c1* T + c0}. The residuals between the fits and the actual data points were calculated for every point, and proven to be much smaller for the temperature-compensated fits than for the linear fits for all sensors. An example is shown in Fig. 3. When the temperature-compensated fits from STAR 1 were applied to the STAR 2 data, the residuals did not improve, suggesting that the change in sensitivity between these two calibration runs was not due to temperature. A third round of calibration (STAR 3) was conducted to further address the temperature dependence of the total HFGs, and the resulting sensitivities matched closely to STAR 2 (within 2%). Temperature-compensated calibration curves were once again fit to the data. In this case, when the temperature-compensated fits from STAR 3 were applied to STAR 2 data, the residuals between the fits and STAR 2 data were much lower than the residuals due to the linear fits. This suggests that the changes seen between STAR 1 and STAR 2 were likely due to actual changes in the sensors caused by the environmental testing between the two calibrations. A modification of the original calibration process, in which the UUT was exposed to each heat flux for just 3 seconds (instead of 10) to reduce the temperature increase during the test, was additionally performed on several of the HFGs. In general, the sensitivities were 1-1.5% lower than from the 10-second tests, but the temperatures were also significantly lower. When the temperature-compensated fits from the 10-second tests were applied to the 3-second test data, the residuals were greatly improved than when just using the linear fits, further suggesting that the temperature-compensated fits may lead to better accuracy than the linear fits in flight. Convective Calibration The second portion of this study was to create a mapping between the radiative and convective calibration coefficients. The majority of the heating during flight will be convective, so it is important to understand how the HFG response differs under these conditions. However, there are no standardized methods for convective calibration [5]. Because the TPS aerothermal response models were validated at LCAT, the same facility was chosen for convective calibration of two of the total HFGs (Fig. 4). Preliminary results showed that the full-scale output was 3% and 8% higher in convective heat flux as compared to radiative heat flux. However, tunnel variation may have contributed to noise and uncertainty in the measurements, and more testing and analysis remains to be done. Scope of Presentation The presentation will include an overview of the changes seen in HFG calibration before and after environmental testing, differences between radiative and convective calibrations, the modeling work done to aid in understanding the sensor response to varying environments, and recommended future work.

H S Alpert↗

The Interstellar Polarization Feature Associated with the 2175 Angstrom Extinction Bump

The most successful model at fitting the wavelength dependence of interstellar extinction consists of two populations of bare silicate and graphite grains (Mathis, Rumpl & Nordsieck, (MRN)). The graphite grains are needed to fit the strong 2175 A extinction bump, with the silicates providing most of the smooth extinction seen at other wavelengths. From observations of the IR silicate absorption features, it was inferred that the silicate grains, non-spherical and aligned to the Galactic magnetic field, were responsible for the interstellar polarization. Aligned silicate grains make a very good fit to the smooth featureless UV polarization curves that comprise most of the observed sample. The lines of sight showing a UV polarization feature require something different, perhaps a second population of grains as do the fits to the extinction curve. The polarization wavelength dependence of HD 197770 can be fit by a MRN-like mixture of aligned bare silicate and graphite grains. However, none of the popular grain models including MRN envisaged an aligned bump grain population. It has been suggested that the extinction bump is not due to graphite but rather to a population of polycyclic aromatic hydrocarbons (PAHs). If the observed UV polarization features could be associated with the 2175 A bump then it would strengthen the argument that the bump must be due to grains rather than PAHs which are not likely to be aligned to the Galactic Magnetic field. The reality of ultraviolet polarization features has been confirmed by observations with ASTRO-2. The original detection toward HD 197770 has been confirmed and a new feature has been detected toward HD 147933-4. Both features have centroids lying close to 2175 A the location of the UV extinction bump. Two possibilities are considered for the source of the polarization bump, alignment of graphite grains responsible for the extinction bump or changes in the size distribution of the aligned silicate grains responsible for the continuum polarization. It seems the graphite grains are a more likely source of the polarization.

Clayton, Geoffrey C.↗

Interpretation of BM Orionis

The entire light curve of the BM Ori system both inside and outside primary and secondary eclipses has been examined on the basis of two models for the disk around the secondary component: one with the luminous energy of the disk coming entirely from the secondary, and another with the luminous energy coming at least partly from the primary. It has been found that if the disk is highly opaque, as is suggested by the fitting of the light curve, there exist in the first model discrepancies between what has been derived from the luminosity consideration for the secondary component and what has been derived from the radius consideration. Hence the second model is accepted. Based on this model the nature of both component stars has been examined from a consideration of the luminosity and the dimensions of the disk.

Huang, S.-S.↗

Constraining RV variation using highly reddened Type Ia supernovae from the Pantheon+ sample

ABSTRACT Type Ia supernovae (SNe Ia) are powerful tools for measuring the expansion history of the Universe, but the impact of dust around SNe Ia remains unknown and is a critical systematic uncertainty. One way to improve our empirical description of dust is to analyse highly reddened SNe Ia [E(B − V) > 0.4, roughly equivalent to the fitted SALT2 light-curve parameter c > 0.3]. With the recently released Pantheon+ sample, there are 57 SNe Ia that were removed because of their high colour alone (with colours up to c = 1.61), which can provide enormous leverage on understanding line-of-sight RV. Previous studies have claimed that RV decreases with redder colour, though it is unclear if this is due to limited statistics, selection effects, or an alternative explanation. To test this claim, we fit two separate colour–luminosity relationships, one for the main cosmological sample (c < 0.3) and one for highly reddened (c > 0.3) SNe Ia. We find the change in the colour–luminosity coefficient to be consistent with zero. Additionally, we compare the data to simulations with different colour models, and find that the data prefers a model with a flat dependence of RV on colour over a declining dependence. Finally, our results strongly support that line-of-sight RV to SNe Ia is not a single value, but forms a distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of the early spectra and light curve of SN 1987A

Numerical modeling of supernova spectra, light curves, and hydrodynamics requires physical inputs, numerical techniques, approximations, and assumptions which must be thoroughly understood in order to study the details of supernova explosions. Here, we discuss some of these in the context of the early evolution of supernova 1987A. Gray radiation-hydrodynamics is used to calculate the bolometric light curve and the hydrodynamic evolution of the supernova. Synthetic spectra are then obtained for the resulting density and velocity structure. The spectrum calculations are performed using a special-relativistic treatment of the radiative transfer equation in the comoving frame, line blanketing by about 10(exp 5) spectral lines, and departures from local thermodynamic equilibrium (LTE) for H I, He I, Mg II, and Ca II. We find that we are able to simultaneously fit the early light curve and spectra reasonably well, using a progenitor model from Arnett (1991a), without fine-tuning the free parameters. Temperature structures and radiative equilibrium, non-LTE effects, homologous expansion, and mean opacities are discussed.

Hauschildt, Peter H.↗

A Simple Model for the Light Curve Generated by a Shoemaker-Levy 9 Impact

The impact of a typical Shoemaker-Levy 9 fragment produced three light peaks as seen from Earth. The first peak is related to the entry of the fragment into the Jovian atmosphere. The second peak occurs when the exploding fireball rises above Jupiter's limb into direct view from Earth. The third peak, much the brightest, occurs when the ejecta plume falls back on the atmosphere. By contrast, Galileo, which had a direct view of the impacts, saw two peaks, one at entry, and one at plumefall. Here we present a simple, highly idealized model of a ballistic plume, which we then use to fit the observed light curve of the R impact as recorded at Mauna Kea and Mount Palomar. From the light curve we find that the nominal R fragment had diameter 450-500 m and mass approx. 2-3 x 10(exp 13) g. The uncertainty in the mass is probably about a factor of 3, with a smaller event more likely than a larger one.

Zahnle, Kevin↗

Practical guide to understanding goodness-of-fit metrics used in chemical state modeling of x-ray photoelectron spectroscopy data by synthetic line shapes using nylon as an example

Chemical state analysis of a sample surface through fitting bell-shaped curves to x-ray photoelectron spectroscopic polymer data is reviewed using nylon to introduce and discuss aspects of data analysis. Different strategies for modeling chemistry in nylon spectra are presented and in so doing, a case is made to include in published science the design logic and implementation in terms of line shapes and optimization parameter constraints between components in a peak model. Imperfections in line shape relative to the true shape for photoemission lines, when compensated for using constraints to optimization parameters, are shown to provide chemical state information about a sample that justify, for peak models constructed with these limitations, metrics for goodness-of-fit different from those expected for pulse-counted data.

Materials Science↗

Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

Luecke, William E.↗

Data Validation in the Kepler Science Operations Center Pipeline

We present an overview of the Data Validation (DV) software component and its context within the Kepler ScienceOperations Center (SOC) pipeline and overall Kepler Science mission. The SOC pipeline performs a transiting planetsearch on the corrected light curves for over 150,000 targets across the focal plane array. We discuss the DV strategy forautomated validation of Threshold Crossing Events (TCEs) generated in the transiting planet search. For each TCE, atransiting planet model is fitted to the target light curve. A multiple planet search is conducted by repeating the transitingplanet search on the residual light curve after the model flux has been removed; if an additional detection occurs, aplanet model is fitted to the new TCE. A suite of automated tests are performed after all planet candidates have beenidentified. We describe a centroid motion test to determine the significance of the motion of the target photocenterduring transit and to estimate the coordinates of the transit source within the photometric aperture; a series of eclipsingbinary discrimination tests on the parameters of the planet model fits to all transits and the sequences of odd and eventransits; and a statistical bootstrap to assess the likelihood that the TCE would have been generated purely by chancegiven the target light curve with all transits removed.

photometry↗

Gamma-Ray Pulsar Light Curves in Vacuum and Force-Free Geometry

Recent studies have shown that gamma-ray pulsar light curves are very sensitive to the geometry of the pulsar magnetic field. Pulsar magnetic field geometries, such as the retarded vacuum dipole and force-free magnetospheres have distorted polar caps that are offset from the magnetic axis in the direction opposite to rotation. Since this effect is due to the sweepback of field lines near the light cylinder, offset polar caps are a generic property of pulsar magnetospheres and their effects should be included in gamma-ray pulsar light curve modeling. In slot gap models (having two-pole caustic geometry), the offset polar caps cause a strong azimuthal asymmetry of the particle acceleration around the magnetic axis. We have studied the effect of the offset polar caps in both retarded vacuum dipole and force-free geometry on the model high-energy pulse profiles. We find that, compared to the profiles derived from symmetric caps, the flux in the pulse peaks, which are caustics formed along the trailing magnetic field lines, increases significantly relative to the off-peak emission, formed along leading field lines. The enhanced contrast produces improved slot gap model fits to Fermi pulsar light curves like Vela, with vacuum dipole fits being more favorable.

Harding, Alice K.↗

Effects of different pretreatment methods on the drying characteristics and quality of potatoes

Abstract The effects of different pretreatments on the vitamin C content of peeled fresh potato, the drying characteristics, and several quality attributes of dehydrated potatoes were investigated. Citric acid pretreatment (0.1%–0.3%, 10–30 min), steam blanching (100ºC, 1–2 min), and water blanching (95°C, 1–2 min) were found to have no obvious effect on the drying rate of potatoes, whereas temperature was the main influencing factor. In terms of quality of dehydrated diced potato, 20 min of citric acid pretreatment resulted in the highest vitamin C retention and better color. Furthermore, dehydrated potato pretreated with citric acid all showed similar dynamic moisture adsorption curves, namely type II sorption isotherm. The moisture adsorption curves can be well fitted using the Guggenheim–Anderson–deBoer model with R 2 higher than .97.

Sun, Xiangfeng↗

Real-time nuclear activation detectors for measuring neutron angular distributions at the National Ignition Facility (invited)

The Real Time Nuclear Activation Detector (RTNAD) array at NIF measures the distribution of 14 MeV neutrons emitted by deuterium-tritium (DT) fueled inertial confinement fusion implosions. The uniformity of the neutron distribution is an important indication of implosion symmetry and DT shell integrity. The array consists of 48 LaBr 3 (Ce) crystal gamma-ray spectrometers mounted outside the NIF target chamber, which continuously monitor the slow decay of the 909 keV gamma-ray line from activated 89 Zr located in Zr cups surrounding each crystal. The measured decay rate dramatically increases during a DT implosion in proportion to the number of 14 MeV neutrons striking each Zr cup. The neutrons produce activated 89 Zr through an (n, 2n) reaction on 90 Zr, which is insensitive to low energy neutrons. The neutron flux along the detector line-of-sight at shot time is determined by extrapolating the fitted 909 keV decay curve back to shot time. Automatic analysis algorithms were developed to handle the non-stop data stream. The large number of detectors and the high statistical accuracy of the array enable the spherical harmonic modes of the neutron angular distribution to be measured up to L ≤ 4 to provide a better understanding of implosion dynamics. In addition, these data combined with measurements of the down-scattered neutrons can be used to derive fuel areal density distributions. This paper will describe the RTNAD hardware and analysis procedures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗