Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Role of initial conditions in plasma-current coupling of gas-puff Z-pinches

Azimuthal magnetic field measurements obtained during the implosion phase of an oxygen gas-puff Z-pinch on a 500 kA peak current and 180 ns rise time linear transformer driver are presented. While a fraction of the driver current was measured within the imploding plasma, key initial conditions were found to significantly impact the delivery of current to the plasma load. The electrode geometry was modified to assist the initial dielectric breakdown and resulted in improved shot reproducibility. Optimization of the gas injection plenum pressure and timing resulted in an increase in the current coupling parameter, defined as the ratio of the measured value of $B$ $θ$ to the expected value, from 50% to 75%. Furthermore, the degree of radial expansion of the gas puff in the load region, which is suspected to lead to the observed current loss during the implosion, was reduced by shortening the valve opening duration. Additionally, a pre-embedded axial magnetic field of up to 0.2 T was found to have no significant impact on the plasma-current coupling of the oxygen implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial tests of large format sensors for the ATLAS ITk strip tracker

For the construction of the Inner Tracker (ITk) as part of the phase-II upgrade programme of the ATLAS detector for the High-Luminosity (HL) LHC, batches of Long Strip (LS) and Short Strip (SS) n + -in-p type micro-strip sensors have been produced by Hamamatsu Photonics and Infineon. The full size sensors measure approximately 98 × 98 mm 2 and are designed and engineered for tolerance against the 9.7 × 10 14 1 MeV n eq /cm 2 fluence expected at the HL-LHC, including a safety factor of 1.5. Each sensor has 2 or 4 columns of 1280 individual channels arranged at 75.5 μ m horizontal pitch. To ensure the sensors comply with their specifications, a Quality Control (QC) procedure has been implemented, comprising measurements on every individual sensor as well as on a sample basis. Every sensor is subjected to an initial visual inspection, after which the full surface of the sensor is captured with very high resolution by an automated camera setup. Non-contact metrology is performed to obtain the sensor surface profile. Electrical measurements establishing the reverse bias leakage current and depletion voltage are then conducted automatically. Sample sensors from every batch are subjected to 40 h of leakage stability checks in controlled atmosphere, and tests on every channel measuring leakage current, coupling capacitance and bias resistance are done. The recorded results are uploaded to a production database following data quality checks. In this paper, QC test validation data and the compiled results for the first batches of production grade sensors are presented. The QC protocol was validated, and the first production sensors were confirmed to be within specification. The results are compared to those from the previous generation of prototype sensors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenic operation of planar ultrananocrystalline diamond field emission source in SRF injector

Here, we report a demonstration of electron beam generation in a superconducting radio frequency (SRF) Teraelectronvolt Energy Superconducting Linear Accelerator 1.3 GHz gun equipped with a field emission cathode and operated at 2 K. The cathode is a submicrometer film of nitrogen-incorporated ultrananocrystalline diamond [(N)UNCD] deposited atop a Nb RRR300 cathode plug that is 4 mm in diameter. Measurements of the output current showed that it increased exponentially as a function of the gun gradient. Our results demonstrate a feasible path toward simplified fully cryogenic SRF injector technology. At a maximal gradient of 0.9 MV/m, a current density of 22 μA/cm2 was obtained [calculated as a 2.75 μA current over the total cathode surface area of π(2 mm)2]. One important finding is that the electron emitter made of (N)UNCD, a material long been known as a highly efficient field emission material, demonstrated a record low turn-on gradient of 0.6 MV/m. A hypothesis explaining this behavior is proposed.

43 PARTICLE ACCELERATORS↗

New Muon Campus Simulations for the Muon $g\textrm{-}2$ Experiment at Fermilab

The Muon $g\textrm{-}2$ Experiment (E989) at Fermilab conducted high-precision measurements of the muon anomalous magnetic moment $a_{\mu}$ using a storage ring from 2018 to 2023, achieving a remarkable precision of $200\:\mathrm{ppb}$ over Runs 1-3, with analyses for Runs 4-6 ongoing. A comprehensive understanding of the storage ring's beam dynamics and its accurate simulations are crucial for achieving the experiment's ambitious goals. One of the requirements for this effort is a very detailed knowledge of the phase space distribution of the beam. To address this requirement, we performed high-statistics simulations of the Muon $g\textrm{-}2$ Target Station (AP0) and the Muon Campus beamlines: M2 and M3, followed by the Delivery Ring, and then M4 and M5. The resulting muon distribution at the end of the M5 beamline from our previous $3\times10^{12}$ protons-on-target (PoT) simulation serves as an essential input for the storage ring simulations. In 2024, to facilitate the analyses of Runs 4-6, we have updated our Muon Campus models and re-optimised certain parameters to reflect the operational currents and wire chamber measurements of the beam. For these optimisations, we employed the heterogeneous island method, implemented in our evolutionary optimisation tool, glyfada. This key update addresses the need to use the best possible beam for the storage ring simulations and thus supports the experiment's overall precision. The Muon $g\textrm{-}2$ Experiment at Fermilab has successfully achieved its $70\:\mathrm{ppb}$ systematic uncertainty goal and collected 21 times more data than its predecessor at BNL. The updated and improved Muon Campus models and simulations not only facilitate the experiment's efforts to potentially resolve the current tension between experimental measurements and theoretical predictions of $a_{\mu}$, but also provide a basis for future simulations for the Mu2e Experiment (E-973), which utilises shared Muon Campus beamlines.

43 PARTICLE ACCELERATORS↗

Progress Toward Gamma-Ray Imaging for Automated Holdup Measurement in Gloveboxes

Shielded gloveboxes are currently being constructed to facilitate dilution and disposal of many tons of excess plutonium oxide. Measuring holdup in these gloveboxes is expected to be challenging because of the limited available lines of sight through the glovebox shielding. A system of gamma-ray imagers is being developed to provide localization and quantification for holdup. The system will be mounted above the glovebox, where there is minimal shielding. Multiple imagers with overlapping coded-aperture fields of view are employed to enable three-dimensional reconstruction. Compton reconstruction is also available to localize sources outside the coded-aperture field of view. Improved uncertainties with respect to current techniques are expected by virtue of the fixed installation, spectroscopic performance of the detectors, and iterative image reconstruction techniques. Measurement campaigns have been undertaken at an active glovebox at Savannah River Site to test the gamma-ray imaging system in an operational environment, providing a simple test of a single imager that mimics the geometry of the installation proposed for future shielded gloveboxes. Data taken during quiescent periods in the glovebox were used to measure the buildup of material on an outlet filter and record a trend over time. Calibration data was taken with known sources to simplify analysis and provide a reliable assay of the filter. Resulting images make it possible to isolate the filter from other sources and recognize compromised data. This paper will present details of the measurement and analysis methods.

Schmitt, Kyle↗

The Influence of Current Density on Transport of Vanadium Acetylacetonate through a Cation-Exchange Membrane

Fluxes of negatively charged, neutral, and positively charged vanadium acetylacetonates through the cation-exchange membrane Nafion® 211 were measured as functions of current density. Fluxes increase in order V(C 5 H 7 O 2 ) 3 – < V(C 5 H 7 O 2 ) 3 0 < V(C 5 H 7 O 2 ) 3 + as expected for a membrane with fixed negative charges. Furthermore, the dependence of these fluxes on current density is quantitatively consistent with predictions made using independently measured conductivities in Nernst-Planck-Einstein transport equations. However, differences between the three fluxes are smaller than predicted by Donnan equilibrium calculations for Nafion 211 immersed in V(C 5 H 7 O 2 ) 3 solutions. Furthermore, specific interactions between sorbed species appear to be responsible for the relatively rapid transport of V(C 5 H 7 O 2 ) 3 – compared to V(C 5 H 7 O 2 ) 3 + .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward virtual thin-beam 𝜈 cross-section measurements: A feasibility study of 𝜈-Ar interaction analysis with DUNE-PRISM

Neutrino-nucleus cross section measurements are critical for future neutrino oscillation analyses. However, our models to describe them require further refinement, and a deeper understanding of the underlying physics is essential for future neutrino oscillation experiments to realize their ambitious physics goals. Current neutrino cross section measurements provide clear deficiencies in neutrino interaction modeling, but almost all are reported averaged over broad neutrino fluxes, rendering their interpretation challenging. Using the concept of deep underground neutrino experiment-precision reaction independent spectrum measurement (DUNE-PRISM)—a movable near detector that samples multiple off axis positions—neutrino interaction measurements can be used to construct narrow virtual fluxes (less than 100 MeV wide). These fluxes can be used to extract charged-current neutrino-nucleus cross sections as functions of outgoing lepton kinematics within specific neutrino energy ranges. Based on a dedicated simulation with realistic event statistics and flux-related systematic uncertainties, but assuming an almost-perfect detector, we run a feasibility study demonstrating how DUNE-PRISM data can be used to measure muon neutrino charged-current integrated and differential cross sections over narrow fluxes. We find that this approach enables a largely model-independent reconstruction of powerful observables, including energy transfer, typically accessible only in electron scattering measurements, but that large exposures may be required for differential cross section measurements with few-percentage statistical uncertainties.

Neutrino interactions↗

Development of planar P-type point contact germanium detectors for low-mass dark matter searches

The detection of low-energy deposition in the range of sub-eV through ionization using germanium (Ge) with a bandgap of ~ 0.7 eV requires internal amplification of the charge signal. This can be achieved through high electric field that accelerates charge carriers, which can then generate more charge carriers. The minimum electric field required to generate internal charge amplification is derived for different temperatures. We report the development of a planar point contact Ge detector in terms of its fabrication and the measurements of its leakage current and capacitance as a function of applied bias voltage. With the determination of the measured depletion voltage, the field distribution is calculated using GeFiCa, which predicts that the required electric field for internal charge amplification can be achieved in proximity to the point contact. The energy response to an Am-241 source is characterized and discussed. We conclude that such a detector with internal charge amplification can be used to search for low-mass dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Doppler Lidar Motion-Correction Wind Profiles (DLMCPROF-WIND) Value-Added Product Report

Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility currently operates several scanning coherent Doppler lidar (DL) systems that provide accurate height-resolved measurements of wind speed and direction. These instruments operate in the near infrared (IR;1.5 microns) and provide range-resolved measurements of radial velocity, attenuated aerosol backscatter, and signal-to-noise ratio (SNR). The systems are operated using a fixed scan schedule consisting of plan position indicator (PPI) or Doppler Beam-Swing (DBS) scans. PPI scans are performed by scanning the beam in azimuth while maintaining a fixed elevation angle, and DBS scans are similar but typically also include a vertical beam. Radial velocity data from these scans are processed to yield profiles of wind speed direction. For stationary ground-based deployments, the Doppler Lidar Horizontal Wind Profiles (DLPROF-WIND) Value-Added-Product (VAP) provides height- and time-resolved measurements of the winds (Newsom and Krishnamurthy 2022). For operation on a moving platform, modifications to the existing DLPROF-WIND VAP are required to compensate for the effects of the platform motion. This report describes a parallel VAP, DLMCPROF-WIND, that was developed for computing motion-compensated wind profiles from ARM Doppler lidar data acquired during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) campaign, when the lidar was deployed on the German icebreaker Polarstern.

54 ENVIRONMENTAL SCIENCES↗

MESOSCALE THERMAL TRANSPORT MEASUREMENTS OF MULTI-PHASE AND POROUS NUCLEAR FUELS USING A SQUARE-WAVE PULSE THERMOREFLECTANCE TECHNIQUE

The safe and efficient operation of nuclear reactors require accurate knowledge of peak temperatures in the fuel assemblies. The temperature profiles are governed by the thermal transport properties of the fuel, namely the thermal conductivities (k) and thermal diffusivities (D). These values can be very difficult to measure as they are known to vary considerably from the measured bulk values of the fresh fuel, and quickly degrade with increasing burnup [1 -3] . Laser-based techniques have been effectively used for non-destructive and non-contact thermal transport measurements of a wide variety of materials, including nuclear materials [4-6] that would otherwise prove too hazardous or difficult to measure otherwise. In this study, a new thermoreflectance technique known as square-pulse transient thermoreflectance (SPTR) is described and used to determine the mesoscale thermal diffusivity of both uranium sesquisilicide (U3Si2) and uranium nitride (UN) phases in a composite fuel with micron level spatial resolution [7]. This technique employs a rapid train of square-wave pulses from an excitation laser to create a periodic heat flux on a gold coated sample surface. Surface adsorption results in transient film temperatures and hence rapid fluctuations in thermoreflectance that can be measured via a detection laser coupled with a digital oscilloscope. The lasers are coaxially focused on the sample surface, allowing for a sample measurement area of a single convolved laser spot size (~2 µm). A sensitivity analysis was conducted to identify key measurement parameters of this technique using reference materials with a range of thermal conductivities comparable to those of both ceramic, composite, and metal nuclear fuel types (1.4 – 27.2 W/m-K). The reference materials were measured using the new technique as well as a spatial-domain thermoreflectance technique (SDTR) previously reported for a comparison [8]. Additionally, measurements of several U3Si2 and UN phase regions of a polished UN/U3Si2 (70/30 vol.%) sample were taken, and the resulting calculated D values are reported, with both techniques showing excellent agreement between samples. This technique was used to scan a multiphase region at 5 micron increments to generate a local diffusivity map, demonstrating the utility of the techniques for measuring thermal transport properties in specimens with precipitates and secondary phases. Furthermore, the technique is currently being applied to measure thermal properties of Fast Flux Test Reactor (FFTR) irradiated metal fuel specimens whose porous microstructure make it very difficult to measure using other techniques. Comparison of the local scale measurements are compared with the pre-irradiated fuel samples to show the degradation of thermal transport in fuels due to pores from fission gas bubbles and other irradiation induced defects.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Experiences with the Rexon UL-320-FDR: An Automated Thermoluminescent Dosimeter Reader with Removable Contact Heating Planchets and an Infrared Temperature Feedback System

The Rexon UL-320 FDR is a novel resistive-heating thermoluminescent dosimeter reader with a unique temperature measurement system and an automated dosimeter processing mechanism. The removable contact heating planchets have black-body adhesives on the back for capturing temperature information with infrared sensors. A heating cycle feedback loop ensures accurate, precise, and reproducible heating sequences. Heating rates between 0.8 and 40°C s -1 for up to 1,000 s are possible. Photomultiplier tube sensitivity and drift, dark current counts, and planchet glow were measured experimentally. Additionally, 25 LiF:Mg,Ti dosimeters were calibrated to demonstrate reader performance. Sensitivity was optimized at 1,200 V, which produced the highest reference light count to dark current count ratio while extending photomultiplier tube life. Dark current counts measured with typical time-temperature profiles for LiF:Mg,Ti were below 10 counts per channel but increased by up to 2.5% for more extreme heating cycles. Reader sensitivity drifts of up to 10% were observed during extended automated operations with typical time-temperature profiles. Total counts resulting from planchet glow decreased with faster heating rates. Calibrations performed with LiF:Mg,Ti dosimeters yielded results comparable to more established reader designs. Spikes were observed in ~3% of the glow curves from planchet dust and oil burning off at elevated temperatures. The use of N 2 gas and sensitivity drift corrections are recommended to improve dosimetry performance for the UL-320 FDR reader.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of ITER divertor shunts as a synthetic diagnostic for detachment control

Reliable diagnostics that measure the detached state of the ITER divertor plasma will be necessary to control heat flux to the divertor targets during steady state, burning plasma operation. This paper conducts an initial exploration into the feasibility of the divertor shunt diagnostic as a lightweight, robust, and real-time detachment sensor. This diagnostic is a set of shunt lead pairs that measure the voltage drop along the divertor cassette body, from which the plasma scrape-off layer (SOL) current is calculated. Using SOLPS-ITER simulations for control-relevant ITER plasma scenarios, the thermoelectric current magnitude along the SOL is shown to decrease significantly with the onset of partial detachment at the outer divertor target. Electromagnetic modelling of a simplified divertor cassette is used to develop a control-oriented inductance-resistance circuit model, from which SOL currents can be calculated from shunt pair voltage measurements. The sensitivity and frequency-response of the resulting system indicates that the diagnostic will accurately measure SOL thermoelectric currents during ITER operation. These currents will be a good measure of the detached state of the divertor plasma, making the divertor shunt diagnostic a potentially extremely valuable and physically robust sensor for real-time detachment control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precise determination of the $B^0_S - \bar {B}^0_S$ oscillation frequency

Mesons comprising a beauty quark and strange quark can oscillate between particle ($B^0_s$) and antiparticle ($\bar{B}^0_s$) flavour eigenstates, with a frequency given by the mass difference between heavy and light mass eigenstates, Δm s . Here we present a measurement of Δm s using $B^0_s$ → $D^–_sπ^+$ decays produced in proton–proton collisions collected with the LHCb detector at the Large Hadron Collider. The oscillation frequency is found to be Δm s = 17.7683 ± 0.0051 ± 0.0032 ps –1 , where the first uncertainty is statistical and the second is systematic. This measurement improves on the current Δm s precision by a factor of two. We combine this result with previous LHCb measurements to determine Δm s = 17.7656 ± 0.0057 ps –1 , which is the legacy measurement of the original LHCb detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shot noise and universal Fano factor as a characterization of strongly correlated metals

Shot noise measures out-of-equilibrium current fluctuations and is a powerful tool to probe the nature of current-carrying excitations in quantum systems. Recent shot-noise measurements in the heavy-fermion strange metal YbRh 2 Si 2 exhibit a strong suppression of the Fano factor ( F )—the ratio of the current noise to the average current in the dc limit. This system is representative of metals in which electron correlations are extremely strong. Here we carry out the first theoretical study on the shot noise of diffusive metals in the regime of strong correlations. A Boltzmann-Langevin equation formulation is constructed in a quasiparticle description in the presence of strong correlations. We find that F = 3 / 4 in such a correlation regime. Thus, we establish the aforementioned Fano factor as universal to Fermi liquids, and we show that the Fano factor suppression observed in experiments on YbRh 2 Si 2 necessitates a loss of the quasiparticles. Our work opens the door to systematic theoretical studies of shot noise as a means of characterizing strongly correlated metallic phases and materials. Published by the American Physical Society 2024

Wang, Yiming (ORCID:0000000277582921)↗