Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogenic Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Design and performance of the cryogenic focal plane optics assembly for the Infrared Astronomical Satellite (IRAS)

The Infrared Astronomical Satellite (IRAS) has successfully completed its mission of providing an unbiased all-sky survey of astronomical objects in the 8 to 120 micrometer wavelength region. The design and performance of the Focal Plane Optics Assembly (FPOA) for the IRAS instrument is described in this paper. The FPOA consists of 62 survey field stops, 62 individual small field lenses, 124 small spectral filters, and a precision multi-part aluminum housing. The FPOA is capable of repeated thermal cycling from ambient temperature to 2 Kelvin. The spectral filters, along with the detector spectral responses, provide infrared bandpasses of 8-15, 18-30, 46-78, and 85-117 micrometers. The combination of very long wavelengths, liquid helium temperatures, and small size provided a significant design challenge. Spectral filter and field lens designs for the four spectral bands are described. Also, discussed are techniques which were developed for mechanical mounting of the small lenses and spectral filters, and to assure their optical alignment.

Bamberg, J. A.↗

Reference Interferometer Using a Semiconductor Laser/LED Reference Source in a Cryogenic Fourier-Transform Spectrometer

A combination of a single mode AlGaAs laser diode and broadband LED was used in a Michelson interferometer to provide reference signals in a Fourier transform spectrometer, the Composite Infrared Spectrometer, on the Cassini mission to Saturn. The narrowband light from the laser produced continuous fringes throughout the travel of the interferometer, which were used to control the velocity of the scan mechanism and to trigger data sampling. The broadband light from the LED produced a burst of fringes at zero path difference, which was used as a fixed position reference. The system, including the sources, the interferometer, and the detectors, was designed to work both at room temperature and instrument operating temperature of 170 Kelvin. One major challenge that was overcome was preservation, from room temperature to 170 K, of alignment sufficient for high modulation of fringes from the broadband source. Another was the shift of the source spectra about 30 nm toward shorter wavelengths upon cooldown.

Martino, Anthony J.↗

First Detection of 120 GeV Protons with Superconducting Nanowire Detectors

We report the test results for a 120 GeV proton beam incident on superconducting nanowire particle detectors of various wire sizes. NbN devices with the same sensitive area were fabricated with different wire widths and tested at a temperature of 3 K. The relative detection efficiency was extracted from bias current scans for each device. The results demonstrate efficient detection of high energy protons for wire widths less than 400 nm. These results are particularly relevant for novel applications at accelerator facilities, such as the Electron-Ion Collider, where cryogenic cooling is readily available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The X-ray Microcalorimeter Spectrometer (XMS): A Reference Cryogenic Instrument Design for Constellation-X

Constellation-X, a mission now belonging to the Beyond Einstein initiative, is being planned to inherit the x-ray sky from Chandra, XMM-Newton and Astro-E. The first two of four observatories in the constellation will be launched together in 2013 and followed a year later by the launch of the remaining two. The four will independently orbit the Sun-Earth Lagrange point L2. An instrument compliment resides in the Focal Plane Module (FPM) of each observatory 10 m from the Optics Module and consists of three Hard X-ray Telescope (HXT) detectors, a Reflection Grating Spectrometer (RGS) focal plane CCD camera and an X-ray Microcalorimeter Spectrometer (XMS). Instrument awards are scheduled for early 2006. The reference detector for XMS is a 32 x 32 array of microcalorimetric superconducting Transition Edge Sensors (TES). Each pixel casts a variable resistance in a SQUID based multiplexed readout circuit which is coupled to series SQUID arrays for amplification and finally read out by external electronics. A multi-stage continuous ADR will provide the stable 50 mK desired for the TES array and a stable 1 K for the series SQUID arrays while also lifting thermal parasitic and inefficiency loads to a 6 K cryocooler interface. The 6 K cryocooler is expected to emerge from the joint-project Advanced Cryocooler Technology Development Program (ACTDP) in which Constellation-X is an active participant. Project Pre-Formulation activities are marked by extensive technology development necessitating early, but realistic, thermal and cooling load requirements for ADR and ACTDP-cryocooler design points. Such requirements are driven by the encompassing XMS cryostat and ultimately by the thermal environment imposed by the FPM. It is further desired that the XMS instrument be able to operate on its side in the laboratory, with a warm vacuum shell, during an extensive calibration regime. It is that reference system design of the XMS instrument (microcalorimeter, ADR, cryocooler and cryostat) which is the subject of this paper.

Whitehouse, Paul L.↗

Calorimetric Low-Temperature Detectors for X-Ray Spectroscopy on Trapped Highly-Charged Heavy Ions

The application of Calorimetric Low-Temperature Detectors (CLTDs) has been proposed at the Heavy-Ion TRAP facility HITRAP which is currently being installed at the Helmholtz Research Center for Heavy Ion Research GSI. This cold ion trap setup will allow the investigation of X-rays from ions practically at rest, for which the excellent energy resolution of CLTDs can be used to its full advantage. However, the relatively low intensities at HITRAP demand larger solid angles and an optimized cryogenic setup. The influence of external magnetic fields has to be taken into account. CLTDs will also be a substantial part of the instrumental equipment at the future Facility for Antiproton and Heavy Ion Research (FAIR), for which a wide variety of high-precision X-ray spectroscopy experiments has been proposed. This contribution will give an overview on the chances and challenges for the application of CLTDs at HITRAP as well as perspectives for future experiments at the FAIR facility.

Kilbourne, Caroline↗

Parallel-Plate Capacitor TiN KIDs for Infrared Astronomy

The Balloon Experiment for Galactic INfrared Science (BEGINS) is a concept for a sub-orbital observatory that will characterize dust in the vicinity of high-mass stars. It requires detectors with NEPs from 2x10 -16 W Hz -1/2 to 6x10 -17 W Hz -1/2 from 25-250 microns, respectively. The mission’s sensitivity requirements will be met by utilizing arrays of 1,840 lens-coupled, lumped-element kinetic inductance detectors (KIDs) operating at 300 mK. Each KID will consist of a titanium nitride (TiN) parallel strip absorbing inductive section and parallel plate capacitor deposited on a Silicon (Si) substrate. The parallel plate capacitor geometry allows for reduction of the pixel spacing. We present the optical performance of a prototype BEGINS KID array at 25 microns when coupled to Fresnel zone plate lenses. We present sensitivity, optical efficiency and quasiparticle lifetime measurements taken in a cryogenic test bed with a cryogenic blackbody.

Joanna Perido↗

First Results from BREAD: Broadband Reflector Experiment for Axion Detection

We report R&D progress, as well as first dark photon search results with BREAD - a novel dish antenna for broadband ~$\mu$eV-eV wave-dark matter detection, which allows to utilize state-of-the-art high-field solenoidal magnets. Axions are converted non-resonantly to photons on a cylindrical metallic wall parallel to an external magnetic field. These photons are then focused using a novel reflector geometry onto a state-of-the-art high-sensitive photon detector. We recently demonstrated [PRL 128 (2022) 131801] that this concept using a $\sim 10\,{\rm m}^2$ conversion area in a $\sim 10\,{\rm T}$ solenoidal magnet has the potential to discover QCD axions spanning multiple decades in mass range. In this talk we discuss progress of our first stage pilot experiments - GigaBREAD and InfraBREAD - covering different mass ranges. We show first results of a room-temperature GigaBREAD prototype and discuss upscaling to larger, cryogenic and magnetized versions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Miniature J-T refrigators using adsorption compressors

More sophisticated cooling systems for the employed detectors will be needed to satisfy the demand for higher resolution and sensitivity of various detectors used in space missions. The design of the cooling system must take into consideration the unique environment of space vehicles. It is pointed out that a deep space vehicle usually has an ample supply of waste heat from a radioisotope thermoelectric generator (RTG) and has a heat sink near zero Kelvin. Passive radiative coolers have been used for cooling temperatures above 90 K. Cooling below 90 K is currently handled by phase changes of solid or liquid cryogens or mechanical refrigeration. However, the weight of the cryogen may be a problem in a long duration space mission. Refrigerators of small cooling capacity are required in many spacecraft applications. For some future NASA missions, a multistage Joule-Thomson refrigerator using adsorption compressors appears particularly attractive. A study is discussed of four different refrigeration stages which use charcoal as the adsorbent. The adsorbed gases are nitrogen, helium, hydrogen, and neon.

Chan, C. K.↗

Developing a New Generation of Integrated Micro-Spec Far Infrared Spectrometers for the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The current state of far-infrared astronomy drives the need to develop compact, sensitive spectrometers for future space and ground-based instruments. Here we present details of the µ-Spec spectrometers currently in development for the far-infrared balloon mission EXCLAIM. The spectrometers are designed to cover the 555 – 714 µm range with a resolution of R = λ/∆λ = 512 at the 638 µm band center. The spectrometer design incorporates a Rowland grating spectrometer implemented in a parallel plate waveguide on a low-loss single-crystal Si chip, employing Nb microstrip planar transmission lines and thin-film Al kinetic inductance detectors (KIDs). The EXCLAIM µ-Spec design is an advancement upon a successful R = 64 µ-Spec prototype, and can be considered a sub-mm superconducting photonic integrated circuit (PIC) that combines spectral dispersion and detection. The design operates in a single M=2 grating order, allowing one spectrometer to cover the full EXCLAIM band without requiring a multi-order focal plane. The EXCLAIM instrument will fly six spectrometers, which are fabricated on a single 150 mm diameter Si wafer. Fabrication involves a flip-wafer-bonding process with patterning of the superconducting layers on both sides of the Si dielectric. The spectrometers are designed to operate at 100 mK, and will include 355 Al KID detectors targeting a goal of NEP ∼8 × 10−19 W/√( Hz). We summarize the design, fabrication, and ongoing development of these µ-Spec spectrometers for EXCLAIM.

Carolyn G. Volpert↗

Arrays of Nano Tunnel Junctions as Infrared Image Sensors

Infrared image sensors based on high density rectangular planar arrays of nano tunnel junctions have been proposed. These sensors would differ fundamentally from prior infrared sensors based, variously, on bolometry or conventional semiconductor photodetection. Infrared image sensors based on conventional semiconductor photodetection must typically be cooled to cryogenic temperatures to reduce noise to acceptably low levels. Some bolometer-type infrared sensors can be operated at room temperature, but they exhibit low detectivities and long response times, which limit their utility. The proposed infrared image sensors could be operated at room temperature without incurring excessive noise, and would exhibit high detectivities and short response times. Other advantages would include low power demand, high resolution, and tailorability of spectral response. Neither bolometers nor conventional semiconductor photodetectors, the basic detector units as proposed would partly resemble rectennas. Nanometer-scale tunnel junctions would be created by crossing of nanowires with quantum-mechanical-barrier layers in the form of thin layers of electrically insulating material between them (see figure). A microscopic dipole antenna sized and shaped to respond maximally in the infrared wavelength range that one seeks to detect would be formed integrally with the nanowires at each junction. An incident signal in that wavelength range would become coupled into the antenna and, through the antenna, to the junction. At the junction, the flow of electrons between the crossing wires would be dominated by quantum-mechanical tunneling rather than thermionic emission. Relative to thermionic emission, quantum mechanical tunneling is a fast process.

Son, Kyung-Ah↗

Mechanical Design of a 4-Stage ADR for the PIPER mission

The four 1,280 bolometer detector arrays that will fly on the balloon borne PIPER mission will be cooled by a 4-stage adiabatic demagnetization refrigerator (ADR). Two of the three mechanically independent ADR assemblies provide thermal isolation to their salt pills through Kevlar suspensions while the other provides thermal isolation to its salt pill through the use of bellows and Vespel material. The ADR integrates with the detector arrays and it sits in a large bucket Dewar containing superfluid liquid helium. This paper will describe the complex mechanical design of the PIPER ADR, and summarize the mechanical analysis done to validate the design.The four 1,280 bolometer detector arrays that will fly on the balloon borne PIPER mission will be cooled by a 4-stage adiabatic demagnetization refrigerator (ADR). Two of the three mechanically independent ADR assemblies provide thermal isolation to their salt pills through Kevlar suspensions while the other provides thermal isolation to its salt pill through the use of bellows and Vespel material. The ADR integrates with the detector arrays and it sits in a large bucket Dewar containing superfluid liquid helium. This paper will describe the complex mechanical design of the PIPER ADR, and summarize the mechanical analysis done to validate the design.

Cryogenics↗

NASA Tech Briefs, February 2011

Topics covered include: Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly; Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection; Photocatalytic Active Radiation Measurements and Use; Computer Generated Hologram System for Wavefront Measurement System Calibration; Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System; SpaceCube 2.0: An Advanced Hybrid Onboard Data Processor; CMOS Imager Has Better Cross-Talk and Full-Well Performance; High-Performance Wireless Telemetry; Telemetry-Based Ranging; JWST Wavefront Control Toolbox; Java Image I/O for VICAR, PDS, and ISIS; X-Band Acquisition Aid Software; Antimicrobial-Coated Granules for Disinfecting Water; Range 7 Scanner Integration with PaR Robot Scanning System; Methods of Antimicrobial Coating of Diverse Materials; High-Operating-Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength; A Model of Reduced Kinetics for Alkane Oxidation Using Constituents and Species for N-Heptane; Thermally Conductive Tape Based on Carbon Nanotube Arrays; Two Catalysts for Selective Oxidation of Contaminant Gases; Nanoscale Metal Oxide Semiconductors for Gas Sensing; Lightweight, Ultra-High-Temperature, CMC-Lined Carbon/Carbon Structures; Sample Acquisition and Handling System from a Remote Platform; Improved Rare-Earth Emitter Hollow Cathode; High-Temperature Smart Structures for Engine Noise Reduction and Performance Enhancement; Cryogenic Scan Mechanism for Fourier Transform Spectrometer; Piezoelectric Rotary Tube Motor; Thermoelectric Energy Conversion Technology for High-Altitude Airships; Combustor Computations for CO2-Neutral Aviation; Use of Dynamic Distortion to Predict and Alleviate Loss of Control; Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards; and A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks.

Source record↗

First characterisation of the MAGO cavity, a superconducting RF detector for kHz–MHz gravitational waves

Heterodyne detection using microwave cavities is a promising method for detecting high-frequency gravitational waves (GWs) or ultralight axion dark matter. In this work, we report on studies conducted on a spherical 2-cell cavity developed by the MAGO collaboration for high-frequency GWs detection. Although fabricated around 20 years ago, the cavity had not been used since. Due to deviations from the nominal geometry, we conducted a mechanical survey and performed room-temperature plastic tuning. Measurements and simulations of the mechanical resonances and electromagnetic properties were carried out, as these are critical for estimating the cavity’s GW coupling potential. Based on these results, we plan further studies in a cryogenic environment. The cavity characterisation does not only provide valuable experience for a planned physics run but also informs the future development of improved cavity designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thin Film Thermal Conductivity Measurements using Superconducting Nanowires

We present a simple experimental scheme for estimating the cryogenic thermal transport properties of thin films using superconducting nanowires. In a parallel array of nanowires, the heat from one nanowire in the normal state changes the local temperature around adjacent nanowires, reducing their switching current. Calibration of this change in switching current as a function of bath temperature provides an estimate of the temperature as a function of displacement from the heater. This provides a method of determining the contribution of substrate heat transport to the cooling time of superconducting nanowire single photon detectors. Understanding this process is necessary for successful electrothermal modeling of superconducting nanowire systems.

Shaw, M. D.↗

Preliminary Cryogenic Cold Test Results of the First 9-Cell LSF Shape Cavity

Following successful prototyping and testing of single- & 5-cell LSF shape cavities *, **, the first 9-cell LSF shape cavity LSF9-1 was successfully constructed using an innovative process at JLab with the in-house facilities. The cavity was then shipped to KEK for post-fabrication mechanical adjustment and ILC TDR style treatment and surface processing. Cold testing was carried out at the JLab VTA facility, instrumented with a suite of Kyoto instruments. Favorable values for the bath pressure detuning sensitivity and Lorentz force detuning coefficient were experimentally measured, validating the design improvement in cell stiffeners. Pass-band measurements indicate 4 out of 9 cells reaching gradient capability of > 45 MV/m, including 2 cells reaching 51 MV/m. Cornell OST detectors identified the cell and location responsible for the current hard quench limit. Multipacting-like barriers observed in end cells are investigated both analytically and numerically. The cavity was shipped to FNAL and received a light EP at the joint ANL/FNAL facility for further cold testing at Jlab. Two new 9-cell LSF cavities are being constructed including one made of large-grain niobium material.

43 PARTICLE ACCELERATORS↗

MegaMIR: The Megapixel Mid-Infrared Instrument for the Large Binocular Telescope Interferometer

The Megapixel Mid-infrared Instrument (MegaMIR) is a proposed Fizeau-mode camera for the Large Binocular Telescope operating at wavelengths between 5 and 28 micrometers. The camera will be used in conjunction with the Large Binocular Telescope Interferometer (LBTI), a cryogenic optical system that combines the beams from twin 8.4-m telescopes in a phase coherent manner. Unlike other interferometric systems, the co-mounted telescopes on the LBT satisfy the sine condition, providing diffraction-limited resolution over the 40" field of view of the camera. With a 22.8-m baseline, MegaMIR will yield 0.1" angular resolution, making it the highest resolution wide field imager in the thermal infrared for at least the next decade. MegaMIR will utilize a newly developed 1024 x 1024 pixel Si:As detector array that has been optimized for use at high backgrounds. This new detector is a derivative of the Wide-field Infrared Survey Explorer (WISE) low-background detector. The combination of high angular resolution and wide field imaging will be a unique scientific capability for astronomy. Key benefits will be realized in planetary science, galactic, and extra-galactic astronomy. High angular resolution is essential to disentangle highly complex sources, particularly in star formation regions and external galaxies, and MegaMIR provides this performance over a full field of view. Because of the great impact being made by space observatories like the Spitzer Space Telescope, the number of available targets for study has greatly increased in recent years, and MegaMIR will allow efficient follow up science.

ultraluminous galaxies↗

Silicon Wafer-Scale Substrate for Microshutters and Detector Arrays

The silicon substrate carrier was created so that a large-area array (in this case 62,000+ elements of a microshutter array) and a variety of discrete passive and active devices could be mounted on a single board, similar to a printed circuit board. However, the density and number of interconnects far exceeds the capabilities of printed circuit board technology. To overcome this hurdle, a method was developed to fabricate this carrier out of silicon and implement silicon integrated circuit (IC) technology. This method achieves a large number of high-density metal interconnects; a 100-percent yield over a 6-in. (approximately equal to 15-cm) diameter wafer (one unit per wafer); a rigid, thermally compatible structure (all components and operating conditions) to cryogenic temperatures; re-workability and component replaceability, if required; and the ability to precisely cut large-area holes through the substrate. A method that would employ indium bump technology along with wafer-scale integration onto a silicon carrier was also developed. By establishing a silicon-based version of a printed circuit board, the objectives could be met with one solution. The silicon substrate would be 2 mm thick to survive the environmental loads of a launch. More than 2,300 metal traces and over 1,500 individual wire bonds are required. To mate the microshutter array to the silicon substrate, more than 10,000 indium bumps are required. A window was cut in the substrate to allow the light signal to pass through the substrate and reach the microshutter array. The substrate was also the receptacle for multiple unpackaged IC die wire-bonded directly to the substrate (thus conserving space over conventionally packaged die). Unique features of this technology include the implementation of a 2-mmthick silicon wafer to withstand extreme mechanical loads (from a rocket launch); integrated polysilicon resistor heaters directly on the substrate; the precise formation of an open aperture (approximately equal to 3x3cm) without any crack propagation; implementation of IR transmission blocking techniques; and compatibility with indium bump bonding. Although designed for the microshutter arrays for the NIRSpec instrument on the James Webb Space Telescope, these substrates can be linked to microshutter applications in the photomask generation and stepper equipment used to make ICs and microelectromechanical system (MEMS) devices.

Jhabvala, Murzy↗

Optical Measurement of Mass Flow of a Two-Phase Fluid

An optoelectronic system utilizes wavelength-dependent scattering of light for measuring the density and mass flow of a two-phase fluid in a pipe. The apparatus was invented for original use in measuring the mass flow of a two-phase cryogenic fluid (e.g., liquid hydrogen containing bubbles of hydrogen gas), but underlying principles of operation can readily be adapted to non-cryogenic two-phase fluids. The system (see figure) includes a laser module, which contains two or more laser diodes, each operating at a different wavelength. The laser module also contains beam splitters that combine the beams at the various wavelengths so as to produce two output beams, each containing all of the wavelengths. One of the multiwavelength output beams is sent, via a multimode fiberoptic cable, to a transmitting optical coupler. The other multiwavelength output beam is sent, via another multimode fiber-optic cable, to a reference detector module, wherein fiber-optic splitters split the light into several multiwavelength beams, each going to a photodiode having a spectral response that is known and that differs from the spectral responses of the other photodiodes. The outputs of these photodiodes are digitized and fed to a processor, which executes an algorithm that utilizes the known spectral responses to convert the photodiode outputs to obtain reference laser-power levels for the various wavelengths. The transmitting optical coupler is mounted in (and sealed to) a hole in the pipe and is oriented at a slant with respect to the axis of the pipe. The transmitting optical coupler contains a collimating lens and a cylindrical lens that form the light emerging from the end of the fiber-optic cable into a fan-shaped beam in a meridional plane of the pipe. Receiving optical couplers similar to the transmitting optical couplers are mounted in the same meridional plane at various longitudinal positions on the opposite side of the pipe, approximately facing the transmitting optical coupler along the same slant. Light collected by each receiving optical coupler is sent, via a multimode fiber-optic cable, to a detector module similar to the reference detector module. The outputs of the photodiodes in each detector module are digitized and processed, similarly to those of the reference detector module, to obtain indications of the amounts of light of each wavelength scattered to the corresponding receiving position. The value for each wavelength at each position is also normalized to the reference laser-power level for that wavelength. From these normalized values, the density and the mass flow rate of the fluid are estimated.

Wiley, John↗