Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Hydrogen Contamination Detector: Protecting the future of zero-emission fuel cell energy [Brief]

Los Alamos National Laboratory developed an electrochemical detector to protect zero-emission hydrogen fuel cells from contaminated fuels. Fuel cells power environmentally clean vehicles, fork lifts, drones, and provide auxiliary power. High-purity hydrogen is essential to avoid poisoning fuel cells. Current analysis methods are costly and cannot detect impurities in realtime. The Hydrogen Contamination Detector measures the two highest impact Department of Energy-identified impurities with a simple, low-cost unit that provides 24/7, point-of-service analysis. Los Alamos partnered with H2Frontiers to conduct field trials at hydrogen refueling stations and with Skyre LLC for commercialization through a DOE Technology Commercialization Fund project.

08 HYDROGEN↗

Predictive Contaminant Transport Simulation with the P2R Model for the Composite Analysis Base Case

In order to meet the requirements of U.S. Department of Energy (DOE) in DOE O 435.1 Chg. 1, Radioactive Waste Management, a composite analysis (CA) must be completed for the Central Plateau at the Hanford Site. The updated Hanford Site CA requires estimates of fate and transport of radionuclides in the groundwater from multiple sources within and downgradient of the Central Plateau. Numerical simulations using the MT3D-MST computer code were conducted to evaluate the fate and transport of existing distributions of 16 radionuclides as identified in CP-62184, Hanford Site Composite Analysis: Radionuclide Selection for Groundwater Pathway Evaluation: tritium (H-3), carbon-14 (C-14), chloride- 36 (Cl-36), strontium-90 (Sr-90), technetium-99 (Tc-99), rhenium-187 (Re-187), radium-226 (Ra-226), thorium-230 (Th-230), uranium-232 (U-232), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), neptunium-237 (Np-237), and uranium-238 (U- 238). This document details the application of the P2R Model version 8.3 to predict the fate and transport of contaminants in groundwater on the Central Plateau for the 10,052 year simulation to support the CA. The simulation of fate and transport of contaminants reported in this environmental calculation file (ECF) will support dose predictions as part of the updated Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaporation Induced Entrainment of Contaminants from Evaporating and Burning Liquids.

This interim report details model development, theory, and a literature review focusing on the evaporation induced entrainment (sub-boiling) of contaminated liquids. Entrainment from a variety of sources is the topic of DOE Handbook 3010, and this report deals more broadly with fire related airborne sources of contaminants in hazardous operations. Relatively few studies have examined sub-boiling behavior in the past, however, it can be a phenomenon that presents a fire related risk under hazardous operations. Molecular dynamics simulations are used to infer the gaseous evolution of coordinated complexes, and a model for a water/plutonium/nitrate system is deduced from the simulation results by evaluating the statistical trends of the results. Questions remain as to the chemical reactivity and longevity of entrained species. A generalized computer model capability and simple analytical model assumptions are developed for predicting the results of these and other (boiling and solid entrainment) scenarios. Verification related predictions using these models are illustrated.

36 MATERIALS SCIENCE↗

Permanent Foam Fixatives for Radioactive Contamination Control: Environmental Chamber Testing

The Department of Energy (DOE) Office of Environmental Management (EM) is tasked with closing cleanup sites throughout the DOE-EM complex. A major component of successfully closing the sites is the deactivation and decommissioning (D&D) of radioactively contaminated buildings in nuclear facilities. Deactivation consists of the process of placing a contaminated facility in stable condition in order to minimize any risks that could affect workers, the public, and the environment. Successful deactivation and decommissioning consists of leaving the buildings in an agreed upon end state to provide future protection against hazards. Hazards include radiation but can also include asbestos, polychlorinated biphenyls, and other environmental and physical hazards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coal Fired Power Plant Configuration and Operation Impact on Plant Effluent Contaminants and Conditions

The primary objective of this project is to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. This project was in response to the U.S. Department of Energy (DOE) Solicitation DE-FOA-0001842. The project duration was between September 01, 2018, and December 31, 2021 (no-cost extension filed, due to the Covid-19 pandemic restrictions, and approved). Field and lab test program was conducted with the main goal to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. In this project, the team of Lehigh University (prime recipient) and Western Kentucky University identified two suitable Thermoelectric Power Plants (TTPs) firing bituminous and sub-bituminous coals respectively, designed test plans, and performed sample collection. Sampling included coal from each TTPs power generation units, Wet Flue Gas Desulfurization (WFGD) slurry material and waste-water samples taken from the outlet of the water treatment tank prior to discharge and other pertinent locations. Coal samples are dried, crushed, and pulverized according to the American Society for Testing and Materials (ASTM) methods. The prepared coal samples are analyzed for normal proximate and ultimate analysis tests in addition to the toxic metals and anions according to ASTM methods. The FGD slurry materials are analyzed for toxic metals and anions according to Electric Power Research Institute (EPRI) or Environmental Protection Agency (EPA) methods, as appropriate. The wastewater samples from the water treatment tank outlet are analyzed for toxic metals and anions according to EPA methods. The effluent species analyzed include mercury, arsenic, selenium, nitrate/nitrite, bromide, and chlorine. This project provided results of effluent conditions as a function of coal type, unit configuration, and unit operation profile, and identified the levels of uncertainty in the effluent results.

01 COAL, LIGNITE, AND PEAT↗

Unclassified Source Term and Radionuclide Data for the Groundwater Flow and Contaminant Transport Model for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nye County, Nevada, Revision 1

This report documents the evaluation of information and data available on the unclassified source term and radionuclide (RN) contamination for Central and Western Pahute Mesa (PM): Corrective Action Units (CAUs) 101 and 102. The Central and Western PM CAUs constitute two areas of the Nevada National Security Site (NNSS) used for underground nuclear testing (Figure 1-1). Eighty-five underground nuclear tests were conducted at the PM CAUs between 1965 and 1992 (NNSA/NFO, 2015b). Underground nuclear tests deposit radioactive elements in the subsurface, resulting in groundwater contamination in the vicinity of the underground test locations. At the PM CAUs, the testing resulted in more than 2.68 × 10 7 curies (Ci) of radioactivity (decay-corrected to September 30, 2012) remaining underground (Finnegan et al., 2016). Of the 85 underground nuclear tests conducted at the PM CAUs, three were shallow tests detonated within 200 meters (m) of the surface and referred to as the “near-surface tests”; the remaining 82 were detonated deeper than 200 m below ground surface (bgs) and are referred to as the “deep underground tests” in this document.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Opportunities for Improvement in FRMAC's Assessment Method for Ingestion of Contaminated Crops

This report provides recommendations to improve the assessment method of the Federal Radiological Monitoring and Assessment Center (FRMAC) for the ingestion of crops contaminated with radionuclides. The current FRMAC method of calculating investigation levels (ILs) and crop derived response levels (DRLs) is detailed. Recommended modifications to these calculations are presented based on the following aspects: handling radionuclide mixtures, no immediate equilibrium, washing of contaminated crops, and updated dietary intake rates.

54 ENVIRONMENTAL SCIENCES↗

Initial Uncertainty Analysis of Carbon Tetrachloride Contamination and Remediation in the Ringold A and Lower Mud Units at the Central Plateau

The long-term effectiveness of groundwater cleanup at the Hanford Site Central Plateau depends on predictive models that can capture key uncertainties in contaminant fate and transport. Carbon tetrachloride (CCl 4 ), a persistent and toxic compound, presents particular challenges due to variability in degradation rates, uncertainty in initial plume distribution, and subsurface heterogeneity. These uncertainties directly influence plume persistence, migration pathways, and remedy performance, and thus must be systematically evaluated to support long-term remediation planning. To address these gaps, a large-scale Monte Carlo analysis was conducted using the Plateau to River (P2R) model framework. The modeling approach parameterized three primary uncertainty factors: (1) degradation rate, (2) initial plume distribution, and (3) hydraulic conductivity. Degradation was represented as a first-order process, with half-lives ranging from 70 to 700 years. Initial plume distributions were created using a geostatistical simulation method (sgsim), which generates many equally plausible versions of how contaminants might be distributed underground. From this, 100 different scenarios were mapped onto the P2R grid. Variability in hydraulic conductivity was represented in a similar way, with 100 scenarios each for the Ringold Lower Mud and Ringold A units (layers 6 and 7), based on fitted exponential variograms and conditioned to well data. In total, more than 1000 realizations were simulated to assess plume behavior under uncertainty. Results demonstrate that degradation kinetics exert the strongest control over plume persistence: Shorter half-lives produced rapid mass reduction, while longer half-lives yielded persistent plumes with limited attenuation. A nonlinear response was observed, with steep mass reductions at half-lives greater than 200 years and near-linear declines beyond this threshold, reflecting interactions between degradation and pumping. The initial plume distribution strongly influenced early transport patterns, with broader sources generating larger plume footprints, although pump-and-treat operations constrained plume migration to managed areas. By comparison, hydraulic conductivity variability in the Ringold units had only a secondary influence, modifying spreading behavior without altering the dominant migration pathways governed by source configuration and hydraulic controls. Overall, the analysis highlights that uncertainty in degradation rate and initial plume configuration are the primary drivers of variability in plume predictions, while conductivity heterogeneity plays a limited role. These findings underscore the need for improved site-specific data on degradation processes and source characterization to enhance the reliability of long-term performance assessments and to better inform remedial decision-making at the Central Plateau.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Enhancement of Medium Temperature Baked Nb SRF Cavity by Surface Contamination Removal

Medium-temperature (mid-T) baking, typically conducted at 300 350 C, enhances the quality factor of niobium (Nb) superconducting radio frequency cavities. However, surface contamination introduced during vacuum furnace baking can limit the cavity performance. To investigate this effect, a 1.3 GHz single-cell Nb cavity underwent mid-T baking, followed by a chemical treatment to remove the surface contaminants. Post-treatment measurements revealed a significant improvement in both the quality factor and the quench field.

Chouhan, Vijay [Fermilab]↗

A Data-driven Phytotechnology Framework for Identification and Remediation of Leached-Metals-Contaminated Soil Near Coal Ash Impoundments

This project developed and evaluated advanced remote sensing and machine learning approaches to identify, monitor, and address environmental contamination associated with coal combustion residual (CCR) impoundments and landfills at coal-fired power plants. In Phase I, historical and multi-temporal Sentinel-2 satellite imagery, groundwater monitoring data, and environmental variables were integrated to detect vegetation stress potentially caused by toxic metal leaching from coal ash disposal sites. Multiple vegetation and biophysical indices were analyzed to determine their effectiveness in identifying abnormal vegetation growth patterns linked to contamination. Results from case studies conducted at coal ash–impacted power plant sites in North Carolina and Virginia demonstrated that satellite-based vegetation monitoring can serve as an effective early indicator of environmental stress associated with metals such as arsenic, cadmium, cobalt, lead, lithium, radium, and thallium.

01 COAL, LIGNITE, AND PEAT↗

Degradation Comparison of Cyclic and Linear Siloxane Contamination on Solid Oxide Fuel Cells Ni-YSZ Anode

The solid oxide fuel cell (SOFC) nickel-yttria stabilized zirconia (Ni-YSZ) anode degradation due to different types of siloxane contamination is investigated. A cyclic structure siloxane, octamethylcyclotetrasiloxane (D4), and a linear structure siloxane, decamethyltetrasiloxane (L4), are mixed with H 2 +N 2 as the fuel for SOFCs at 750°C. The electrochemical characterization results after stability experiments suggest that the SOFC contaminated with cyclic siloxane, D4, had higher degradation. Pure YSZ pellets with different surface hydroxylation extents were also tested to investigate the D4/L4 adsorption and deposition process. Postmortem SEM/WDS, XRD and Raman analysis all indicate that cyclic siloxane has more deposition than linear siloxane on the anode. Further analysis demonstrates that high adsorption and low desorption rates of cyclic siloxane on YSZ are linked to the degradation. Besides the silicon deposition, SiC and amorphous carbon deposition were also observed from the XRD and Raman analysis.

25 ENERGY STORAGE↗

Community response of soil microorganisms to combined contamination of polycyclic aromatic hydrocarbons and potentially toxic elements in a typical coking plant

Both polycyclic aromatic hydrocarbons (PAHs) and potentially toxic elements (PTEs) of coking industries impose negative effects on the stability of soil ecosystem. Soil microbes are regarded as an essential moderator of biochemical processes and soil remediation, while their responses to PAHs-PTEs combined contamination are largely unknown. In the present study, soil microbial diversity and community composition in the typical coking plant under the chronic co-exposure of PAHs and PTEs were investigated and microbial interaction networks were built to reveal microbial co-occurrence patterns. The results indicated that the concentrations of PAHs in the soil inside the coking plant were significantly higher than those outside the plant. The mean concentration of ∑16PAHs was 2894.4 ng·g −1 , which is 5.58 times higher than that outside the plant. The average Hg concentration inside the coking plant was 22 times higher than the background value of Hebei province. The soil fungal community inside the coking plant showed lower richness compared with that of outside community, and there are significant difference in the bacterial and fungal community composition between inside and outside of coking plant ( p < 0.01). Predicted contribution of different environmental factors to each dominant species based on random forest identified 20 and 25 biomarkers in bacteria and fungi, respectively, that were highly sensitive to coking plant soil in operation, such as Betaproteobacteria,Sordariomycetes and Dothideomycetes . Bacterial and fungal communities were shaped by the soil chemical properties (pH), PTEs (Hg), and PAHs together in the coking plant soils. Furthermore, the bacterial and fungal interaction patterns were investigated separately or jointly by intradomain and interdomain networks. Competition is the main strategy based on the co-exclusion pattern in fungal community, and the competitive relationship inside the coking plant is more complex than that outside the plant. In contrast, cooperation is the dominant strategy in bacterial networks based on the co-occurrence pattern. The present study provided insights into microbial response strategies and the interactions between bacteria and fungi under long-term combined contamination.

Shen, Qihui↗

Evaluation of aflatoxin contamination in protein-rich pulses using a GFP-expressing Aspergillus flavus strain

Background Mycotoxigenic fungi pose significant threats to food safety and marketability. Crop-specific differences in susceptibility to these fungi can influence contamination levels. Objectives The resistance or susceptibility of protein-rich pulse crops—chickpeas (Cicer arietinumL. cv. CDC Frontier), lentils (Lens culinarisMedik cv. Eston), peas (Pisum sativumL. cv. LeRoy), and corn (Zea maysL. cv. H97C) to infection byAspergillus flavuswere evaluated using a kernel screening assay (KSA). Methodology A. flavusstrain 70 (AF-70) expressing green-fluorescent protein (GFP) was used to quantify fungal spread and mycotoxin production. Fungal infection and toxin levels, including aflatoxins (AFB 1 , AFB 2 ), cyclopiazonic acid (CPA), and α-aflatrem, were monitored at 2-day intervals over a 10-day period post inoculation. Results Although all seeds were infected byA. flavus, corn produced significantly higher levels of AFB 1 and AFB 2 compared to pulses. However, pulses accumulated relatively higher levels of CPA and α‑aflatrem. Conclusion While pulses may be less susceptible to aflatoxin contamination than corn, the elevated concentrations of CPA and α‑aflatrem underscore the need for further toxicological evaluation and mechanistic studies. Future research should explore the underlying resistance mechanisms from field to storage to better ensure crop safety.

Microbiology↗

Detection and Screening of Organic Contaminants in A Riverine System of Georgia Using Non-Targeted Analysis

Numerous organic chemicals exist within aquatic environments, yet effectively screening and prioritizing them is a huge challenge. This study provides a comprehensive investigation into the ecological dynamics of the North Oconee River within Athens-Clarke County, Georgia, with a specific focus on the distribution of 33 identified compounds, including a prominent pesticide. The research, conducted in the riverine ecosystems proximal to the Firefly trail, employs advanced analytical techniques to elucidate potential contamination sources arising from agricultural and urban runoff. Intriguingly, the study reveals North Oconee River near the Firefly Trail as a notable site for heightened pesticide contamination, warranting a meticulous exploration of its origins. Furthermore, the investigation unveils the intricate microbial degradation processes of malathion within the North Oconee River, elucidating the pivotal role played by microbial activity in river water. The detection of degradant byproducts prompts the considerations of bioavailability and toxicity, associating potential implications for the river’s overall ecological health. Ongoing research endeavors to precisely quantify environmental risks and unravel indigenous microbial degradation pathways, presenting pivotal contributions to the scientific community’s understanding of complex riverine ecosystems. This research serves as a foundational piece in informing sustainable environmental management practices and emphasizes the urgency of comprehensive stewardship in safeguarding aquatic ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Valve effectively controls amount of contaminant in flow stream

Contaminant valve with a coaxial groove rotor uniformly deposits contaminant into a flow stream under full pressure and flow conditions. The valve tests filters and filter elements of hydraulic oil, fuel, or lubricant systems without any detrimental effect on the performance.

Schnitzer, T. E.↗

Purification of contaminated water by filtration through porous glass

Method for purifying water that is contaminated with mineral salts and soluble organic compounds is described. Method consists of high pressure filtration of contaminated water through stabilized porous glass membranes. Procedure for conducting filtration is described. Types of materials by percentage amounts removed from the water are identified.

Wydeven, T.↗