Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computed Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Clean Condensing Gas Furnace

Natural gas furnaces are the most common space heating equipment in the U.S. residential and commercial building markets. However, current residential natural gas condensing furnaces generate substantial acidic condensate as well as significant emissions of sulfur oxides (SOx), nitrogen oxides (NOx), carbon monoxide (CO), hydrocarbons (HC), and methane (CH 4 ) contributing to environmental degradation of air, water, and soil. This report describes a novel solution to reduce the environmental impact of natural gas condensing furnaces based on the technology of a monolithic acidic gas reduction (AGR) catalyst for SOx trapping, NOx redox to nitrogen, and oxidation of formic acid, CO, HC, and CH 4 . The AGR technology offers the following benefits: (1) a neutral furnace condensate with a pH of ~7, allowing its safe release into the sewer system thus eliminating a second drainage system; (2) trapping and removing nearly all SOx emissions; (3) NOx emissions nearly at nearly 1-2 ng/J, more than 95% lower than new emissions standards in California; (4) the use of a low-cost heat exchanger as a condensing heat exchanger (HX) since the condensate is not acidic, avoiding the need for expensive stainless steel alloys; and (5) unburnt fuel energy recovery to boost efficiency.The AGR component and AGR-enabled furnace performance were broadly tested to determine their effects on long-term reliability and durability, as well as SOx storage and regeneration activity. The AGR regeneration does not impair the performance in achieving neutral condensate and ultra-low NOx emissions, and the AGR catalyst subjected to regeneration activities continued to function well and achieved slightly better annual fuel utilization efficiency (AFUE). The 400-hour reliability and durability test of the retrofitted condensing furnace with the AGR component shows that the furnace unit still achieves a neutral furnace condensate with a pH of ~7 and enables 0~3 ng/J of NOx emissions. However, the 400-hour operation slightly degraded the AFUE because of soot particle accumulation caused by frequent incomplete combustion owing to inappropriate condensate drainage during testing. Thus, proper condensate drainage is critical for AGR-enabled furnaces. Furthermore, neutron computed tomography was employed to survey the aged AGR component and demonstrate high-resolution 2D and 3D representations for the nondestructive diagnosis of the AGR component. The tomography showed that the AGR component did not deform or suffer broken AGR channels. A new AGR catalyst with low precious metal loading was preliminarily explored to identify a pathway of optimizing AGR material loading and maximizing acidic gas reduction at low cost. The new AGR component can reduce precious metal loading by 38% and still achieve neutral condensate and ultralow NOx emissions. The furnace with the AGR component of low Pt/Rh loading enables a maximum AFUE of 97%, which is meaningfully higher than the original furnace. Long-duration testing for the furnace enabled with the low precious metal loading AGR component will be vital in future research. Although the current work demonstrates a proof of concept for the AGR-enabled furnace, the AGR assembly needs to be optimized and integrated into the design of new OEM furnace products. Furthermore, the AGR technology can be applied not only for residential gas furnaces, but also for commercial rooftop units, gas heat pumps, gas-fired water heaters, combustion boilers, and other systems.

03 NATURAL GAS↗

Technology Enabling Zero-EPZ Micro Modular Reactors: Fabrication of Zirconium Hydride with Controlled Hydrogen Loading

This report completes Milestone M2.2.2 - ZrH pellet fabricated with controlled hydride loading: ZrH1.5±0.1 single phase pellets fabricated with controlled and thermally stable hydride loading. Hydrogen content to be quantified and single-phase confirmed by X-ray diffraction. In this milestone, we report the successful fabrication of delta-phase zirconium hydride pellets using the ORNL bulk metal hydriding system. The successful deployment of zirconium hydride moderator in advanced reactors requires development of a consistent and affordable production pathway along with implementation of a hydrogen retention solution throughout the reactor life. Fabrication of delta-phase zirconium hydride is challenging since the absorption of a large amount of hydrogen into alpha-zirconium induces significant volume expansion and the present hydrogen concentration gradient results in cracking. A fully programmable hydriding system with continuous hydrogen partial pressure and flow control to facilitate processing of massive metal hydride has been developed at ORNL. In this report, the working principle of the hydriding system will be introduced. Characterization of the produced zirconium hydride includes X-ray powder diffraction to identify the present phases and X-ray Computed Tomography to visualize the internal microstructure (including cracks). The results indicate that single delta-phase zirconium hydride pellets with various sizes have been successfully produced.

36 MATERIALS SCIENCE↗

In-Situ Spatial Mapping of Hydrogen in Yttrium Hydrides at LANSCE

This report summarizes the neutron imaging techniques and experimental activities performed at the Los Alamos Neutron Science Center (LANSCE) with the main goal of measuring temperature driven hydrogen diffusion within bulk-yttrium hydride (YH x ) materials. The experimental results and technique developments reported herein support the US Department of Energy Office of Nuclear Energy’s (DOE-NE) Microreactor Program under Technology Maturation. In particular, the critical need to experimentally validate and verify hydrogen-diffusion models of metal hydrides used in hightemperature microreactor designs is addressed by means of high-spatial-resolution neutron imaging coupled with custom-built and application-specific furnaces. These capabilities were designed to apply large temperature gradients across centimeter-sized YH x pellets to simulate conditions faced in the microreactor environment. Neutron imaging, combined with in-situ sample heating, enables near real-time tracking of hydrogen diffusion in YH x on the sub-millimeter scale. In this report, an overview of neutron imaging methodology and technologies are given in the context of recent spatial measures of hydrogen concentrations in similar metals hydrides. Additionally, the commissioning and operation of a custom-built compact dual-zone furnace is given along with details on the first two in-situ heating measurements of YH x performed over the 2020 and 2021 LANSCE operation cycles. In parallel with in-situ heating measurements, neutron computed tomography scans were performed to visualize hydrogen aggregates in post-heated YH x samples. Analysis and results from these neutron imaging measurements are given along with outlooks and plans for improving future hydrogen diffusion measurements at LANSCE.

47 OTHER INSTRUMENTATION↗

Quantification of morphological change in materials based on image data utilizing machine learning techniques

Computed tomography (CT) resolution has become high enough to monitor morphological changes due to aging in materials in long-term applications. We explored the utility of the critic of a generative adversarial network (GAN) to automatically detect such changes. The GAN was trained with images of pristine Pharmatose, which is used as a surrogate energetic material. It is important to note that images of the material with altered morphology were only used during the test phase. The GAN-generated images visually reproduced the microstructure of Pharmatose well, although some unrealistic particle fusion was seen. Calculated morphological metrics (volume fraction, interfacial line length, and local thickness) for the synthetic images also showed good agreement with the training data, albeit with signs of mode collapse in the interfacial line length. While the critic exposed changes in particle size, it showed limited ability to distinguish images by particle shape. The detection of shape differences was also a more challenging task for the selected morphological metrics that related to energetic material performance. We further tested the critic with images of aged Pharmatose. Subtle changes due to aging are difficult for the human analyst to detect. Both critic and morphological metrics analysis showed image differentiation.

36 MATERIALS SCIENCE↗

Understanding Phase and Interfacial Effects of Spall Fracture in Additively Manufactured Ti-5Al-5V-5Mo-3Cr

Additive manufactured Ti-5Al-5V-5Mo-3Cr (Ti-5553) is being considered as an AM repair material for engineering applications because of its superior strength properties compared to other titanium alloys. Here, we describe the failure mechanisms observed through computed tomography, electron backscatter diffraction (EBSD), and scanning electron microscopy (SEM) of spall damage as a result of tensile failure in as-built and annealed Ti-5553. We also investigate the phase stability in native powder, as-built and annealed Ti-5553 through diamond anvil cell (DAC) and ramp compression experiments. We then explore the effect of tensile loading on a sample containing an interface between a Ti-6Al-V4 (Ti-64) baseplate and additively manufactured Ti-5553 layer. Post-mortem materials characterization showed spallation occurred in regions of initial porosity and the interface provides a nucleation site for spall damage below the spall strength of Ti-5553. Preliminary peridynamics modeling of the dynamic experiments is described. Finally, we discuss further development of Stochastic Parallel PARticle Kinteic Simulator (SPPARKS) Monte Carlo (MC) capabilities to include the integration of alpha (α)-phase and microstructural simulations for this multiphase titanium alloy.

36 MATERIALS SCIENCE↗

X-ray CT Scans - Minerals - Set 1

A collection of x-ray computed tomography scans of mineral specimens from private collections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduced diffusion and enhanced retention of multiple radionuclides from pore structure characterization of barrier materials for enhanced repository performance

Fluid flow and chemical transport in porous media are the macroscopic consequences of pore structure, which integrates geometry (e.g., pore size and surface area, pore-size distribution) and topology (e.g., pore connectivity). Low-permeability geological media whose pores are poorly interconnected will exhibit the characteristics of anomalous diffusion and sample size-dependent effective porosity, which will strongly impact long-term net diffusion and retention of radionuclides in geological repository settings involving different host rocks and barrier materials. A suite of innovative and complementary experimental approaches is utilized to study the microscopic pore structure and macroscopic fluid flow & chemical transport for a range of host rocks and barrier materials, in addition to standard clay minerals and reference rocks. With a particular focus on quantifying the presence and magnitude of “isolated” pores for a reduced effective porosity in low-permeability geomedia, the integrated methodologies for basic properties and pore structure characterization of these geomedia include X-ray diffraction, thin section petrography, grain size distribution, water immersion porosimetry after vacuum-pulling for full saturation, mercury intrusion porosimetry, nitrogen physisorption, scanning electron microscopy, X-ray computed tomography, and (ultra-)small angle neutron (X-ray) scattering. In addition, custom-designed gas diffusion, tracer recipe involving a range of anionic and cationic chemicals with subsequent analyses by laser ablation and inductively coupled plasma-mass spectrometry, along with batch sorption, column transport, and imbibition tests were conducted for coupled effects of pore structure and chemical retention/transport. From the perspectives of pore structure in conjunction with multiple and complementary approaches to examining a range of sample sizes under different observational scales, we find that the poor pore connectivity is prevalent in low-permeability media (mudstone and crystalline rock) that is related to geological processes (e.g., compaction, diagenesis and thermal maturation). For example, the deep and organic matter-rich mudstones have a much smaller effective porosity than the total porosity (as a result of poor pore connectivity) and associated diffusion coefficient, and the effective porosity & diffusion coefficients are also dependent upon the sample sizes used in the measurement. Similarly, most of the pore space in the shallow mudstone is also controlled by pore-throat diameters in the 5-50 nm range of intergranular pore types from its fine-grained nature, but with an overall good pore connectivity. However, the nm-sized pore space (physically pore-network architecture) and strong sorption capacities (chemical retention from clay minerals) of both shallow and deep mudstones lead to the synergistic retention of cationic radionuclides and their utilities as effective host rocks and barrier materials. Our unique approaches of studying how the micro-scale pore structure affect macro-scale fluid flow, diffusion & retention, and chemical transport produce improved mechanistic understanding, and realistic quantification, of diffusion and retention of typical radionuclides in a range of generic host rocks and barrier materials (clay/shale, salt, crystalline rock, and tuff), with the overall results leading to scientifically-based understanding of enhanced isolation (from both diffusion and retention) of radionuclides and improved confidence on the long-term performance of geological repository to store high-level radioactive wastes. In addition to the training of 25 undergraduates, graduates, and postdocs of UTA, the scientists (organizations) involved in performing this work (e.g., discussion, sample sharing, and operation of SANS and SAXS instruments) include Ed Matteo, Yifeng Wang, and Kristopher Kuhlman (Sandia National Laboratories), Jens Birkholzer, Liange Zheng, Tim Kneafsey, and Sharon Borglin (Lawrence Berkeley National Laboratory), Mavrik Zavarin (Lawrence Livermore National Laboratory), Yukio Tachi and Yuta Fukatsu (Japan Atomic Energy Agency), Mieke de Craen (Euridice, Belgium), Markus Bleuel (NIST), Wei-Ren Chen, Gergely Nagy, Changwoo Do, William Heller, Larry Anovitz, and Kenneth Littrell (ORNL), as well as Jan Illvsky, Ivan Kuzmenko, Ju-Sang Park and Jon Almers (ANL). Key deliverables include a total of 13 peer-reviewed journal articles (nine published and three under review), 23 presentations at scientific conferences (AAPG, AAPG Southwest Section, AGU, Asian Clay Conference, GSA, GSA South-Central Section, IHLRWM, InterPore, International Conference on Chemistry and Migration Behavior of Actinides and Fission Products in the Geosphere, International Conference on Coupled Processes in Fractured Geological Media: Observation, Modeling and Application), and academic institutions (UTA, New Mexico State University; University of Poitiers, France; University of Helsinki, Finland; Uppsala University, Sweden; Istanbul Technical University, Turkey) and other organizations (Andra, France; Posiva Oy, Finland).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Next Generation of MeV Energy X-ray Sources for Use in the Inspection of Additively Manufactured Parts for Industry

In September 2022, we investigated whether we can change the way we perform non-destructive characterization (NDC) of dense, micrometer-scale objects, e.g., additively manufactured (AM) parts, using the BELLA inverse Compton source (ICS). X-ray computed tomography (CT) is the most suitable technique for NDC of these objects, but often requires x-rays with MeV energy for penetration, sub-mm spatial resolution for small structures, a narrow spectrum for low-artifact images, and the ability to tune x ray energy to image a wide range of materials. The BELLA ICS has the unique potential to produce such an x-ray beam with a repetition rate high enough for CT. We scanned a geometric calibration phantom, fabricated by LLNL, a bearing, and an AM part manufactured by Renishaw. We reconstructed the first CT images of their kind. The results are very promising, and LLNL will present our findings at an SPIE conference.

42 ENGINEERING↗

Probabilistic Failure Criterion of SiC/SiC Composites Under Multiaxial Loading

Owing to its excellent mechanical properties and stability under high temperature and neutron irradiation conditions, SiC/SiC composites have emerged as a promising material for light water reactors (LWRs) in the development of accident-tolerant fuel (ATF) systems. Structural integrity and retention of hermeticity are two crucial requirements for SiC/SiC claddings during normal operations, and both of them are closely related to the proportional limit stress (PLS) of the material. Understanding the behavior of SiC/SiC composites under multiaxial stress states and developing a probabilistic approach for evaluating the structural vulnerability are of paramount importance for reliability-based analysis and design of SiC/SiC composite claddings. So far, there has been very limited effort towards experimental and analytical investigations of probabilistic failure of SiC/SiC claddings. This critical knowledge gap motivates this research. A probabilistic failure criterion for SiC/SiC composites under multi-axial loading is developed, and this criterion is incorporated into reliability analysis of the structural integrity of SiC/SiC fuel cladding. The research consists of two parts: 1) experimental investigation of multiaxial failure behavior of SiC/SiC composites, and 2) theoretical modeling of time-dependent probabilistic failure of SiC/SiC cladding. In the experimental investigation, the PLS is determined through the examination of stress-strain response, the acoustic emission measurement, as well as the X-ray computed tomography. The theoretical framework is derived by combin- ing the finite weakest-link statistical model and the subcritical damage growth model. This theoretical model captures the time-dependent failure mechanism of the material, which has a major consequence for predicting the lifetime distribution of the cladding. Meanwhile, the model also predicts that the failure statistics of the cladding depends strongly on the cladding length. The results of the multiaxial experiments reveal the level of statistical variation of the PLS of SiC/SiC materials under different stress states. The theoretical model provides a robust analytical tool for extrapolation of small-scale laboratory test results to the behavior of full-scale claddings. These findings establish a scientific foundation for the development of reliability-based design of SiC/SiC fuel claddings, which will play an essential role in improving the structural safety and integrity of LWRs.

42 ENGINEERING↗

Detection of System Drift for the Health Monitoring of an X-ray CT Scientific Instrument

This SE296 Capstone Project technical report is being submitted as a final requirement of the UCSD Master of Science in Structural Engineering with specialization in Structural Health Monitoring (SHM) and Nondestructive Evaluation (NDE). The Capstone provides students the opportunity to apply knowledge in their technology areas towards the solution of an SHM or NDE problem. As an employee of the Lawrence Livermore National Laboratory and NDE/NCI team member, I chose to apply the SHM design paradigm taught at UCSD to improve the health monitoring of the X-ray Micro-Computed Tomography (MCT) system. I would like to thank LLNL’s Dr. Harry Martz for serving as my mentor during this project and the entire LLNL MCT technical team for answering my questions and contributing to my knowledge. I would also like to thank Prof. Michael Todd for recruiting me to the UCSD NDE/SHM program and serving as my graduate advisor.

42 ENGINEERING↗

Material and Design Optimization of Printed Melt Wire Arrays

Recent work conducted by the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory resulted in the establishment of in-house capabilities for fabricating and testing new advanced manufactured sensors for measuring irradiation temperatures inside a nuclear test reactor. Though current methods of real-time temperature monitoring (e.g., thermocouples) can still be used, the complexity of the feedthroughs and attachments needed for collecting real time measurements greatly increases the experiment-related costs. On the other hand, passive monitoring techniques can be used for collecting post irradiation temperature measurements by inferring reactor temperatures, based on the melting points of well-characterized materials (i.e., standard melt wires). However, challenges have arisen due to the limited space available for including instrumentation in experiments. To resolve this issue, the ASI program expanded its temperature detection capabilities to include advance manufactured melt wires for post-irradiation temperature measurements. These melt wires can determine reactor temperatures while also accommodating space limitations in irradiation experiments. To improve performance reliability and enhance melt wire readability following irradiation, FY-22 efforts have focused on optimizing the materials used in the encapsulation and printed melt wire array. This report details the design and fabrication tasks, along with the subsequent x ray computed tomography (XCT) evaluation process. The melt wire array consisted of indium with a melting point of 157°C, indium/silver (96/4 at%) with a melting point of 219°C, and tin with a melting point of 230°C. The encapsulation disc was made of vanadium due to its low activation properties and radiation resistance when deployed in nuclear reactors. Additionally, the melt wire design consisted of a ceramic sublayer (alumina disc) to further enhance the XCT post melting images of the printed melt wires. However, when sealing the vanadium container, all three melt wires melted, reflecting the temperature limitations that must be considered when employing metal containers in the sealing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Situ Spatial Mapping of Hydrogen in Yttrium Hydrides at LANSCE (FY23 Version, Rev. 1)

This report summarizes the development of neutron imaging capabilities and experimental activities performed at the Los Alamos Neutron Science Center (LANSCE) with the main goal of measuring temperature-driven hydrogen diffusion within bulk-yttrium hydride (YH x ) materials. Yttrium hydride is the leading candidate to serve as a solid neutron moderator in microreactor cores, owing to its high density of hydrogen atoms as well as its superior thermal stability compared to all other metal hydrides. The experimental results and technique developments reported herein support the U.S. Department of Energy Office of Nuclear Energy’s (DOE-NE) Microreactor Program under Technology Maturation. In particular, it addresses the critical need to experimentally validate and verify hydrogen-diffusion models of metal hydrides used in high-temperature microreactor designs by means of high-spatial-resolution neutron imaging. These capabilities were designed to apply large temperature gradients across centimeter-sized YH x pellets to simulate conditions faced in the microreactor environment. In principle, neutron imaging, combined with in-situ sample heating, enables near real-time tracking of hydrogen diffusion in YH x on the sub-millimeter scale. In this report, an overview of neutron imaging methodology and technologies are given in the context of recent spatial measures of hydrogen concentrations in similar metal hydrides. Additionally, the commissioning and operation of a custom-built compact dual-zone furnace is given along with details on three in-situ heating measurements of YH x performed over the 2020 to 2022 LANSCE operation cycles. The aims of these experiments ranged from furnace commissioning, determining sample quality, i.e., hydrogen uniformity via neutron computed tomography, and studying the effects of applied temperature-gradients on YH x pellets. Analyses and results from these neutron imaging measurements are given along with outlooks and guidelines for optimal future hydrogen diffusion measurements. Our conclusions are as follows. Image analyses indicate that centimeter-sized yttrium hydride cylindrical pellets exhibit uniform, whole-body hydrogen desorption and absorption without clear temperature dependence as reflected in the image attenuation at the opposing ends of each sample. This suggests that despite the large magnitude in temperature gradients applied by the furnace heating elements, the sample equilibrates to an unknown intermediate temperature. The origin of this result is likely the combination of short sample length (∼1cm) and use of a TZM can for containment where the latter created a thermal short across the sample. Nevertheless, the results from the most recent measurements indicate that neither significant concentration gradients of hydrogen were formed in centimeter-sized samples through the entire temperature range (25 °C to 950 °C) nor any formed due to temperature gradients on the order of 50 °C/cm up to 700 °C/cm. Furthermore, images from the FY2021 and FY2022 measurements indicate that samples of YH x , fabricated from either the direct hydride or powder metallurgy methods, are highly uniform in their hydrogen concentration to within the measurements’ spatial resolutions. The following questions arise from these latest results: 1) What is the intermediate temperature of the pellets in the TZM cans? 2) How quickly does the temperature equilibrate within the sample? and, 3) Do the observed changes in image attenuation follow known pressure-composition-temperature relations of yttrium hydride?

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗