Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Buildings Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Envision Charlotte Project Final Report

The Envision Charlotte Project (EC Project), supported by partners at the Center for Climate and Energy Solutions, the University of North Carolina at Charlotte’s Center for Sustainably Integrated Buildings and Sites and the City of Charlotte, has successfully demonstrated that existing buildings can benefit from operations improvements and low-cost efficiency upgrades, and that behavioral change campaigns can be effectively designed for measurability, longevity and impact. Support from this grant gave Envision Charlotte and its partners the resources and flexibility to demonstrate a variety of approaches to improve coordination with stakeholders in the implementation of programs to reduce the consumption of energy, water and waste. The project team also gained insights into the motivations and abilities that influence stakeholder engagement in sustainability initiatives at multiple levels. Importantly, as this report describes, strong partnerships between nonprofits, industry partners and research institutions can produce tangible impacts and replicable results in building efficiency. Further, building operators working alongside student researchers can form productive relationships that can advance building energy management goals. Key Findings of the EC Project This project focused on advancing solutions to energy efficiency in U.S. commercial buildings. The Building Re-Tuning™ Training (BRT) developed by the U.S. DOE’s Pacific Northwest National Lab (PNNL), designed to detect energy savings opportunities and implement improvements with resources and online tools, provided the starting point for the curriculum developed by stakeholders in the EC Project. Although the project partners encountered some issues with data consistency, the overall project outcomes fell short of the energy savings stated in the original proposal, and the total participating building targets were lower than anticipated, important findings, outcomes and lessons learned were achieved. EC Project grantees observed that the PNNL BRT, as currently written, was not compatible with the skills of average frontline mechanical personnel in the Charlotte region where the grant program was performed. Frontline staff are not, typically, energy managers, engineers or building commissioning agents, but they can play a key role in building performance. As detailed in this report, the grantees therefore focused on changes to the BRT that improved the level of training and competency of the frontline workers in this region. Among the technical observations related to improving the BRT that were observed in the EC Project: centralized facilities management often has an impact on building performance; operators can be overly reliant on service contracts; individual behaviors matter, and technology cannot be viewed as a crutch; current Building Automation Systems (BAS) are often too complex to support building efficiency optimization, but BAS coupled with appropriate training can support better outcomes; the “perfectly optimized” building is not a near-term possibility, but better education, especially of executives and managers, on the role of behavioral intervention is a promising direction the building science community can and should pursue; a lack of standards and protocols, and competition between proprietary software from service contracts, remain challenges for this industry. These technical observations, in turn, informed the EC Project’s overall findings, which were: Accomplishing building efficiency is a process of education for all involved in the building design, construction and operation supply chain. Building operators, as a professional class, have an opportunity for further training and education that will lead to better on-the-job performance. An updated Building Re-Tuning™ Training curriculum, based on the findings of this report, could be an avenue for these operators’ professional development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Molecular Doping Increases the Semitransparent Photovoltaic Performance of Dilute Bulk Heterojunction Film with Discontinuous Polymer Donor Networks

The semitransparent and colorful properties of organic solar cells (OSCs) attract intensive academic interests due to their potential application in building integrated photovoltaics, wearable electronics, and so forth. The most straightforward and effective method to tune these optical properties is varying the componential ratio in the blend film. However, the increase in device transmittance inevitably sacrifices the photovoltaic performance because of severe carrier recombination that originates from discontinuous charge-transport networks in the blend film. In this work, a strategy is proposed via the molecular-doping strategy to overcome these shortcomings. It is discovered that p-doping is able to release the trapped holes in segregated polymer domains leading to short-circuit current enhancement, while n-doping is more effective to fill the bandgap states producing a higher fill factor. More importantly, either type of doping improves the photovoltaic performance in the semitransparent photovoltaic devices. These discoveries provide a new pathway to breaking the compromise between the photovoltaic performance and optical transmittance in semitransparent OSCs, and hold promise for their future commercialization.

14 SOLAR ENERGY↗

Catalyst Layer Design, Manufacturing and In-line Quality Control

In this project we successfully demonstrated the capabilities of the Reactive Spray Deposition Technology (RSDT) to fabricate large-scale CCMs for advanced PEMWEs that have one-order of magnitude lower PGM loading in their catalyst layers, and performance comparable with the commercial state-of-the-art CCMs. The RSDT is a unique methodology that combines the catalyst synthesis and CCM fabrication in one step and reduces dramatically the time for CCM manufacturing. As fabricated large-scale CCMs with geometric area of 680 cm2 demonstrated excellent activity and durability performance, and the novel duo-recombination layer design paves the way for solving the safety concerns related to PEMWEs. In addition, excellent activity and durability performance has been demonstrated with RSDT fabricated CCMs with thinner membranes and duo RL design. This is a novel approach for further performance improvement of the MEAs for PEMWEs that has been successfully demonstrated for the first time in this project. The integration of the in-situ laser diagnostics system along with the in-line optical quality control system within the RSDT that has been achieved and demonstrated in this project, is an example for possibility of designing and building advanced manufacturing technologies that can meet the requirements of the future manufacturing. Therefore, the RSDT offers a precise real-time monitoring and control of the particles size, composition, loading, porosity, thickness, and defects in the catalysts’ layers, which render this technology as the best candidate for manufacturing of cost effective CCMs for PEMWEs. By using RSDT we successfully met all project’s milestones, Go/No-Go decision, objectives, goals, and deliverables.

08 HYDROGEN↗

Application of an AREVA Mobile Evaporator Design Used Successfully at NRC Licensed U.S. Commercial Nuclear Sites to Support Hanford Site Operations - 18134

The U.S. Department of Energy (DOE), Office of River Protection (ORP), manages the River Protection Project at the Hanford site in the South Eastern corner of Washington State in the Pacific Northwest of the United States. The mission of the River Protection Project is to retrieve and treat Hanford's tank waste and close the tank farms to protect the Columbia River. The Site Tank Operations Contractor (Washington River Protection Solutions (WRPS)) via its site operations teams creates additional space in the Double Shell Tanks (DSTs) using the site's only remaining operational evaporator - 242-A. The current 242-A Evaporator has long been identified as a potential single point of failure that in the event of a major breakdown, could significantly impact retrieval operations at the Hanford Site. Areva has experience both on the Hanford site as an integrated subcontractor to the mission and in the design, procurement and construction of a mobile forced circulation evaporator unit designed to be used on Nuclear Regulatory Commission commercial nuclear utility sites. The mobile unit has been used at the following nuclear power plants: SONGS, Salem, Davis Besse, Waterford and Palo Verde. It was designed to take spent Water-EDTA based chemical cleaning solvent and evaporate water off to reduce the volume of waste required to go through downstream processes. It was further designed to fit inside ISO shipping containers. A multi-step approach will be used to: 1. review lessons learned from the previous DOE study for deploying a mobile evaporator on the Hanford sit, 2. evaluate the proposed waste streams and the required throughput and waste arising, sizing the evaporator appropriately, 3. develop a concept design requirements document for the use of a customized evaporator to meet the Hanford need 4. Design, and build a mobile evaporator and 5. Test, install and commission at a site to be agreed with WRPS/DOE. With an overall budget for the approach described of around $35 m, an operational evaporator could be delivered to site in 18-24 months from the approval of a detailed design package. Potential befits include the elimination of the 242-A evaporator as a single point failure, the creation of additional DST tank space and the elimination of the need to stage waste at the 242-A evaporator by moving the mobile unit to a location where is could be deployed at or close to the tank such as in 200W. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Solar Steam on Demand

INTRODUCTION: This Report summarizes the research and development project performed by Sunvapor and the subrecipient National Renewable Energy Laboratory (NREL) during the period of 10/01/2018-9/30/2021. The work was aimed at the economic integration of solar steam with an industrial process, and in particular, the advantages that a novel type of thermal energy storage and collector design could bring to the system. The completed work includes experimental research on the storage material, design of the collector, engineering of a complete solar steam plant, and economic analysis. The plant was, in the end, not constructed, due to COVID-19 impacts to the project host. PURPOSE: The purpose of the project was to test the hypothesis that a levelized cost of heat (LCOH) of 2¢/kWh delivered to a steam-consuming process, including energy discharged from storage, could be feasibly achieved. PROJECT OBJECTIVES: For Budget Period 1 our objectives were to engineer a prototype industrial solar steam generation system, and design and test a Latent Heat Energy Storage (LHES) lab-scale system. For Budget Period 2 our objectives were to construct and test the solar steam prototype plant, and to build and factory-test a full LHES module. For Budget Period 3 our objective was to integrate the storage module with the solar steam generator, show successful long duration energy tests of the combined system, and use the results to project the LCOH of delivered steam to a second-generation plant. PROJECT OUTCOMES: Various phase change materials (PCMs) for the LHES were tested for compatibility with industrial steam uses as measured by phase change temperature, stability of latent heat of fusion, and their corrosive effects on steel (the heat exchanger material). Two of these materials (sodium formate and sodium/ potassium) showed potential to meet the technical criteria. The estimated cost of a complete LHES module with these materials did not meet economic targets. The developmental collector design builds from previous work to exploit the potential cost advantages of a spaceframe of lumber construction. Design improvements were achieved in assembly efficiency and structural performance. A complete engineering package was completed for the solar steam system without storage that included the developmental as well as commercial arrays. The plant was permitted for construction. The storage CAPEX for a reference plant was estimate to be greater than $\$ 57$/kWh. The LCOH of the system without storage and with developmental collectors of lumber construction was projected to be 2¢/kWh, assuming a FCR of 8.2% over thirty years. PROJECT MILESTONES: The Milestones fully achieved in the first Budget Period includes obtaining a Letter of Intent from an industrial steam-consuming project host, issuance of a construction permit, and corrosion resistance. The Milestone that was partly achieved was the degradation in the latent heat of fusion. Milestones associated with Budget Periods 2 and 3, related to the construction and operation of the plant were not achieved as a result of the host shutting down the plant due to COVID-19 impacts. CONCLUSIONS: Sunvapor was able to secure an agreement with a host to build a fully engineered and permitted solar steam plant that met the host’s economic goals. As a basis for comparison, the solar field design was comprised of eight commercial collector arrays and one developmental Green Parabolic Trough Collector (GPTC) array. The projected LCOH with a solar field entirely populated with a second generation GPTC met the goal of 2¢/kWh. The experimental program concerning the PCM indicated the feasibility of meeting their technical requirements for industrial steam uses. The cost of the complete LHES exceeded its $\$ 14$/kWh target, and therefore the inclusion of LHES could not be economically justified. Due to COVID-19 impacts on the host, the solar steam plant was not constructed.

14 SOLAR ENERGY↗

Remote Software Application and Display Development

The era of the shuttle program has come to an end, but only to give rise to newer and more exciting projects. Now is the time of the Orion spacecraft, a work of art designed to exceed all previous endeavors of man. NASA is exiting the time of exploration and is entering a new period, a period of pioneering. With this new mission, many of NASAs organizations must undergo a great deal of change and development to support the Orion missions. The Spaceport Command and Control System (SCCS) is the new system that will provide NASA the ability to launch rockets into orbit and thus control Orion and other spacecraft as the goal of populating Mars becomes ever increasingly tangible. Since the previous control system, Launch Processing System (LPS), was primarily designed to launch the shuttles, SCCS was needed as Kennedy Space Center (KSC) reorganized to a multiuser spaceport for commercial flights, providing a more versatile control over rockets. Within SCCS, is the Launch Control System (LCS), which is the remote software behind the command and monitoring of flight and ground system hardware. This internship at KSC has involved two main components in LCS, including Remote Software Application and Display development. The display environment provides a graphical user interface for an operator to view and see if any cautions are raised, while the remote applications are the backbone that communicate with hardware, and then relay the data back to the displays. These elements go hand in hand as they provide monitoring and control over hardware and software alike from the safety of the Launch Control Center. The remote software applications are written in Application Control Language (ACL), which must undergo unit testing to ensure data integrity. This paper describes both the implementation and writing of unit tests in ACL code for remote software applications, as well as the building of remote displays to be used in the Launch Control Center (LCC).

ACL↗

New Thermochemical Salt Hydrate System for Energy Storage in Buildings

This paper introduces an innovative design for an “inorganic salt-expanded graphite” composite thermochemical system. The storage unit is made of a perforated, compressed, expanded graphite block impregnated with molten CaCl 2 ∙6H 2 O; the humid air passes through the holes that allow the moisture to diffuse and react with the salt. The prepared block underwent 90 hydration-dehydration cycles. Although most of the performed cycles were carried out with salt overhydration and deliquescence, the treated samples have remained mechanically and thermally stable with no drop in energy density. The volumetric energy density of the composite ranged from 135.5 to 277.6 kWh/m 3 , depending on airflow rate and absolute humidity. To ensure composite material cycling stability, the energy density of the block was measured during hydration at similar conditions of absolute humidity, inlet temperature, and airflow rate (0.01 kg water /kg air , 20 °C, 400 l/min). The average energy density at these conditions was sustained at 219 kWh/m 3 . The block integrity was monitored by visual inspection after removing it from the reactor chamber every few cycles. Both the composite material and its manufacturing process are simple and easy to scale up for future commercialization.

25 ENERGY STORAGE↗

Near-Term Reliability and Resilience (NTRR) (Final Report)

The Near-Term Reliability and Resiliency (NTRR) was awarded in December 2020 as an inter-lab project to examine the reliability and resilience of the electricity grid and natural gas transportation availability. The project builds on studies conducted by The North American Electric Reliability Corporation (NERC), the U.S. Department of Energy (DOE), and other non-governmental research and operational focused on reliability and resilience analyses challenges. The research was conceived to address near-term scenarios (within 10 years), when many local and regional policy transitions could begin to impact grid reliability, resilience, and supporting infrastructure availability. To integrate the natural gas interdependency, the team began with the generating capacity and demand projections from the 2020 NERC Long-Term Reliability Assessment and the Bulk Electric System (BES) transmission topologies defined in the Western Electricity Coordinating Council (WECC) Anchor Data Set, Eastern Interconnection Reliability Assessment Group Multi-Regional Modeling Working Group (ERAG/MMWG) Data Set, the team calculated baseline regional power sector gas demands from present electricity delivery year through the end of delivery year 2030/31 by applying security constrained economic dispatch. This demand was compiled along with demand projections for regional residential, commercial, and industrial natural gas demands from the most recent Energy Information Administration (EIA) Annual Energy Outlook Reference Case into Deloitte’s MarketBuilder® North American Gas Model. Through the application of these demands, MarketBuilder® was projected the topology of natural gas flows in the natural gas pipeline network across the interconnected North American system along with regional natural gas prices that may be seen by market participants in future years Additionally, contingencies and sensitivities focused on the built models of the Eastern Interconnection (EI) and Western Interconnection (WI). They address challenges from the following with the outcomes being an identification of performance under the extreme conditions and an identification of potential grid weaknesses that should be addressed to mitigate the reduced performance and improve the resilience and reliability of the specific regions as well as the National Grid: • Weather events including extreme heat, extreme cold, high wind, no wind, wind and solar forecasting errors, and wildfires. • Gas availability, factoring in supply disruption (contractual and physical), seasonal availability constraints, and infrastructure limitations; and • Transmission availability and congestion.

03 NATURAL GAS↗

Mountaineer Commerical Scale Carbon Capture and Storage (CCS) Project

The Final Technical documents all work performed during the award period on the Mountaineer Commercial Scale Carbon Capture & Storage project. This report presents the findings and conclusions produced as a consequence of this work. As identified in the Cooperative Agreement DE-FE0002673, AEP's objective of the Mountaineer Commercial Scale Carbon Capture and Storage (MT CCS II) project is to design, build and operate a commercial scale carbon capture and storage (CCS) system capable of treating a nominal 235 MWe slip stream of flue gas from the outlet duct of the Flue Gas Desulfurization (FGD) system at AEP's Mountaineer Power Plant (Mountaineer Plant), a 1300 MWe coal-fired generating station in New Haven, WV. The CCS system is designed to capture 90% of the CO{sub 2} from the incoming flue gas using the Alstom Chilled Ammonia Process (CAP) and compress, transport, inject and store 1.5 million tonnes per year of the captured CO{sub 2} in deep saline reservoirs. Specific Project Objectives include: (1) Achieve a minimum of 90% carbon capture efficiency during steady-state operations; (2) Demonstrate progress toward capture and storage at less than a 35% increase in cost of electricity (COE); (3) Store CO{sub 2} at a rate of 1.5 million tonnes per year in deep saline reservoirs; and (4) Demonstrate commercial technology readiness of the integrated CO{sub 2} capture and storage system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Project Report "Advanced Concept Exploration For Fast Ignition Science Program"

The Fast Ignition (FI) Concept for Inertial Confinement Fusion has the potential to provide a significant advance in the technical attractiveness of Inertial Fusion Energy (IFE) reactors. FI differs from conventional “central hot spot” (CHS) target ignition by decoupling compression from heating: using the laser (or heavy ion beam or Z pinch) drive pulse (10’s of ns) to create a dense fuel and a second, much shorter (~10 ps) high intensity pulse to ignite a small region of it. There are two major physics issues concerning this concept; controlling the laser-induced generation of large electron currents and their propagation through high density plasmas. This project has addressed these two significant scientific issues in Relativistic High Energy Density (RHED) physics. Learning to control relativistic laser matter interaction (and the limits and potential thereof) will enable a wide range of applications. While these physics issues are of specific interest to inertial fusion energy science, they are also important for a wide range of other HED phenomena, including high energy ion beam generation, isochoric heating of materials, and the development of high brightness x-ray sources. Generating, controlling, and understanding the extreme conditions needed to advance this science has proved to be challenging: Our studies have pushed the boundaries of physics understanding and are at the very limits of experimental, diagnostic, and simulation capabilities in high energy density laboratory physics (HEDLP). Our research strategy has been based on pursuing the fundamental physics underlying the Fast Ignition (FI) concept. We have performed comprehensive study of electron generation and transport in fast-ignition targets with experiments, theory, and numerical modeling. A major issue is that the electrons produced in these experiments cannot be measured directly—only effects due to their transport. We focused mainly on x-ray continuum photons from bremsstrahlung and x-ray line radiation from K-shell fluorescence. Integrated experiments, which combine target compression with short-pulse laser heating, yield additional information on target heating efficiency. This indirect way of studying the underlying behavior of the electrons must be validated with computational modeling to understand the physics and improve the design. This program execution required a large, well-organized team and it was managed by a joint Collaboration between General Atomics (GA), Lawrence Livermore National Laboratory (LLNL), and the Laboratory for Laser Energetics (LLE). The Collaboration was formed 8 years ago to understand the physics issues of the Fast Ignition concept, building on the strengths of each partner. GA fulfills its responsibilities jointly with the University of California, San Diego (UCSD), The Ohio State University (OSU) and the University of Nevada at Reno (UNR). Since RHED physics is pursued vigorously in many countries, international researchers have been an important part of our efforts to make progress. The division of responsibility was as follows: (1) LLE had primary leadership for channeling studies and the integrated energy transfer, (2) LLNL led the development of measurement methods, analysis, and deployment of diagnostics, and (3) GA together with UCSD, OSU and UNR studied the detailed energy-transfer physics. The experimental program was carried out using the Titan laser at the Jupiter Laser Facility at LLNL, the OMEGA and OMEGA EP lasers at LLE and the Texas Petawatt laser (TPW) at UT Austin. Modeling has been pursued on large computing facilities at LLNL, OSU, and UCSD using codes developed (by us and others) within the HEDLP program, commercial codes, and by leveraging existing supercomputer codes developed by the NNSA ICF program. This Consortium brought together all the components—resources, facilities, and personnel—necessary to accomplish its aggressive goals. The ACE Program has been strongly collaborative, taking advantage of the expertise of the participating institutions to provide a research effort that is far greater than the sum of its parts. The results of this work have firmly strengthened the scientific foundation from which the viability of FI and other applications can be evaluated. Program execution has also led to improved diagnostics for probing dense, hot plasmas, detailed understanding of high-current, relativistic electron energy generation and transport across boundaries and into dense plasmas, and greatly enhanced predictive modeling capabilities. One important aspect of this program was the involvement and training of young scientists including postdoctoral fellows and graduate students. During the entire 8 years of FI and ACE project period since 2005, more than fifteen graduate students completed their doctoral dissertations including three from OSU and two from UCSD in last three years. This project generated an impressive forty articles in high quality journals including nine (including two under review) in Physical Review Letters during the last funding period since 2011.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cooperative Research and Development Agreement between University of Genoa and National Energy Technology Laboratory [Abstract]

The production, transportation, storage, and consumption of oil and gas resources rely on a global network of infrastructure, which is maintained and regulated by numerous commercial, non-profit, academia, and local to national government entities. Thus, information about this infrastructure is often highly variable in the quality, quantity and accessibility of the data. However, integrating and standardizing these disparate data sets into a global, open-access assessment and inventory of oil and gas infrastructure can provide a framework to support advanced analyses, including predictions and assessments of global methane infrastructure and emissions risk, identify information gaps, evaluate economic costs, and support a range of decision making needs. At present, there is no single point of access to authoritative, publicly available oil and gas infrastructure data. In addition, conventional online search approaches are increasingly inefficient as the volume and variety of open-data online continues to evolve and increase. Consequently, there exists a great deal of uncertainty surrounding the extent, gaps, and quality of infrastructure data across the world. This six-month effort used a combination of expert driven and machine learning techniques to build a virtual taxonomy of global oil and gas infrastructure to provide an open data foundation for addressing a range of stakeholder questions and needs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Innovations in Building Energy Modeling: Research and Development Opportunities for Emerging Technologies

Building energy modeling (BEM) is a multipurpose tool for building energy efficiency (EE). The U.S. Department of Energy Building Technologies Office (BTO) seeks to expand the use and effectiveness of BEM in the design and operation of commercial and residential buildings with the goal of achieving lasting reductions in total and peak energy use. This report identifies gaps and outlines recommended initiatives to achieve this goal, based on a combination of technical analysis and stakeholder input. In addition to BTO, this report can benefit BEM professionals (architects, mechanical engineers, energy consultants, building auditors, equipment manufacturers, and BEM software vendors) and BEM clients (building owners and operators, EE program administrators, EE service providers, policymakers, and policy and code jurisdictions such as states and cities). This report was developed in two phases. In the first, BTO worked with a team from Navigant Consulting (now Guidehouse) to characterize objectives, opportunities, and current activities; identify gaps and barriers; and define initiatives. To collect input, Navigant conducted telephone interviews and workshops with industry experts. The initial phase produced a draft report, which was released for public review in 2016 and yielded over 400 comments. Based on these comments, BTO compiled a second draft report that addressed many of those comments while acknowledging changes that had occurred both at BTO and in the industry. Unlike the first draft report, the second focused much more heavily on BTO’s own role, portfolio, and activities. BTO is a direct player in the BEM field - it funds the development of several significant software packages that are embedded in commercial products - and transparency about its goals and future plans is requisite. BTO recognizes that a great number of other public and private organizations contribute to the BEM enterprise. With the second draft report, BTO did not attempt to produce a blueprint for the industry as a whole, but rather a working document BTO can use to iteratively solicit stakeholder input and synthesize it into a program. BTO released the second draft report for public review in 2019. The second round of review generated 83 pages of feedback and comments - almost exactly the length of the draft report itself - a significant portion of which was collected and synthesized by IBPSA-USA Advocacy Committee. This final report incorporates this feedback. This report does not address the use of BEM in support of building-based grid services, a recent BTO initiative called Grid-interactive Efficient Buildings (GEB). In 2019, BTO published a report that specifically addresses the role of BEM - and other “integration” technologies - in GEB.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Balancing Science Objectives and Operational Constraints: A Mission Planner's Challenge

The Air Force minute sensor technology integration (MSTI-3) satellite's primary mission is to characterize Earth's atmospheric background clutter. MSTI-3 will use three cameras for data collection, a mid-wave infrared imager, a short wave infrared imager, and a visible imaging spectrometer. Mission science objectives call for the collection of over 2 million images within the one year mission life. In addition, operational constraints limit camera usage to four operations of twenty minutes per day, with no more than 10,000 data and calibrating images collected per day. To balance the operational constraints and science objectives, the mission planning team has designed a planning process to e event schedules and sensor operation timelines. Each set of constraints, including spacecraft performance capabilities, the camera filters, the geographical regions, and the spacecraft-Sun-Earth geometries of interest, and remote tracking station deconflictions has been accounted for in this methodology. To aid in this process, the mission planning team is building a series of tools from commercial off-the-shelf software. These include the mission manifest which builds a daily schedule of events, and the MSTI Scene Simulator which helps build geometrically correct scans. These tools provide an efficient, responsive, and highly flexible architecture that maximizes data collection while minimizing mission planning time.

Weldy, Michelle↗

Way Beyond Widgets: Delivering Integrated Lighting Design in Actionable Solutions

Previously, energy-efficiency strategies for commercial spaces have focused on using efficient equipment without providing specific detailed instructions. Designs by experts in their fields are an energy-efficiency product in its own right. A new national program has developed interactive application-specific lighting designs for widespread use in four major commercial sectors. This paper will describe the technical basis for the solutions, energy efficiency and cost-savings methodology, and installations and measurement/verification to-date. Lighting designs have been developed for five types of retail stores (big box, small box, grocery, specialty market, and pharmacy) and are planned for the office, healthcare, and education sectors as well. Nationally known sustainable lighting designers developed the designs using high-performance commercially available products, daylighting, and lighting controls. Input and peer review was received by stakeholders, including manufacturers, architects, utilities, energy-efficiency program sponsors (EEPS), and end-users (i.e., retailers). An interactive web tool delivers the lighting solutions and analyzes anticipated energy savings using project-specific inputs. The lighting solutions were analyzed against a reference building using the space-by-space method as allowed in the Energy Standard for Buildings Except Low-Rise Residential Buildings (ASHRAE 2004) co-sponsored by the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the Illuminating Engineering Society of North America (IESNA). The results showed that the design vignettes ranged from a 9% to 28% reduction in the allowed lighting power density. Detailed control strategies are offered to further reduce the actual kilowatt-hour power consumption. When used together, the lighting design vignettes and control strategies show a modeled decrease in energy consumption (kWh) by 33% to 50% below the baseline design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemical Reduction of Flue Gas Carbon Dioxide to Commercially Viable C2-C4 Products (Final Report)

This is the final scientific/technical report for a DOE project focused on the electrochemical conversion of CO 2 in non-aqueous solvents to novel products. Electrochemical reduction of CO 2 provides an attractive route to produce valuable fuels and chemicals that can simultaneously lower greenhouse gas emissions when powered by renewable electricity. While recent technological advances have shown the feasibility of industrial CO 2 electroreduction, many challenges remain to improve this technology and expand the list of economically viable products. The vast majority of electrochemical CO 2 reduction research has been conducted in aqueous media under neutral to alkaline conditions, leading to commonly reported products including carbon monoxide, formic acid, methane, methanol, ethylene, acetic acid, and ethanol. In comparison, non-aqueous media for CO 2 reduction has been underexplored but represents a possible avenue to yield new products and improved operating conditions. The aim of the project was to convert waste CO 2 in the form of flue gas to a multicarbon C2 - C4 chemical product in a reactor designed to achieve economically competitive values of current density and selectivity. The project strived to advance the technology readiness of an electrochemical CO 2 reduction process in alcohol solvents from the proof-of-concept stage to a device capable of meeting performance metrics for commercial viability. In the initial plan, the University of Louisville researchers were to focus on investigating the electrochemical process and improving the faradaic efficiency for novel C2 – C4 species, while also working on a parallel effort to build a practical electrolysis reactor to markedly increase the CO 2 reduction current density. The reactor development effort also aimed to engineer a dual-electrolyte feed strategy with non-aqueous catholyte and aqueous anolyte to promote water oxidation as the coupling anodic half-reaction to enable a sustainable and economical overall process. At the outset, the University of North Dakota was to investigate the feasibility of operating directly from coal-derived flue gas without separate capture and purification. The research team sought to determine impurity effects and test mitigation strategies, as well as engineer the gaseous feed system for high reactor tolerance to lower CO 2 concentration. In the last half year of the project, the focus was planned to shift to integrating the advances in the catalysis, electrochemical conditions, reactor design, and flue gas compatibility into a fully functional device and improve it for maximum current density and faradaic efficiency for C2 – C4 species. Knowledge of the full system components, constraints, and maximum performance was then to be used as the basis for a thorough technoeconomic analysis (TEA) and life cycle analysis (LCA) at the end of the project.

01 COAL, LIGNITE, AND PEAT↗

A Generalized Nuclear Code of Accounts for Cost Estimation Standardization

This is a joint INL-EPRI study. Link to corresponding page at the Electric Power Research Institute (EPRI): https://www.epri.com/research/products/000000003002028937 Recent Advanced Reactor (AR) designs typically offer features and attributes that depart from traditional water-cooled reactors in terms of fuel forms, coolants, structural materials, size, safety margins, and other important design and operational aspects. These departures, relative to the industry experience, will likely present a challenge for potential owner-operators when evaluating one or more AR designs for commercial deployment on a like-for-like basis. This is further exacerbated with new classes of reactors gaining prominence (e.g., microreactors) and new emerging applications (e.g., floating barge reactors or space propulsion reactors). The differences in design-specific technologies are compounded by the differences in approach to cost estimation. The lack of consistency in build up toward cost estimates creates a challenge when comparing competing concepts and evaluating their associated cost drivers. The outcome of a 2019 Scoping Study conducted by the Electric Power Research Institute (EPRI) indicated the need for a cost modeling guide (CMG), which would be underpinned by a technology-neutral and inclusive Generalized Nuclear Code of Accounts (GN-COA). A code of accounts (COA) is a tool by which costs are identified in even more specific categories, providing clarity on what specific costs are included in an estimate. A parallel independent effort was meanwhile taking place at Idaho National Laboratory via funding by the Systems Analysis Integration (SA&I) campaign of the Office of Nuclear Energy under the U.S. Department of Energy (U.S. DOE-NE) to also update the COA structure to enable more flexibility and encompass a wider variety of reactor technologies. After being made aware of these synergistic efforts, the two parties decided to combine efforts and develop a joint new standard format for nuclear cost estimation that builds on previous structures. This document describes the development of this joint GN-COA and provides guidance on the implementation of the tool, which is provided as the associated GN-COA Excel document. The main attributes of this novel COA format are that all items are functionally defined (in order to be technology and application agnostic) and grouped into logical arrangements that facilitate the tabulation of costs for reactor constructions under consideration. The intent is for the GN-COA to form a standard that is endorsed by future vendors and customers.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A critical review of cyber-physical security for building automation systems

Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.

97 MATHEMATICS AND COMPUTING↗