Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Megawatt-Scale Low Temperature Electrolyzer Research Capability

The development and installation of a flexible low-temperature electrolyzer research capability at the multi-MW scale with integrated renewables will help lower the cost barrier to entry for electrolyzer manufactures needing at scale system and stack evaluation and enable more electrolyzer manufactures to accelerate to commercialization with building block scale demonstration and validation. This NREL capability represents a DOE HFTO investment to support the $1B DOE Clean Hydrogen Electrolysis Program working to achieve the Hydrogen Shot goal of $1 for 1 kg hydrogen in 1 decade, lower greenhouse gas emissions and criteria pollutants, build clean energy infrastructure, and provide pathways to private sector uptake.

electrical grid↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters (CRADA 625) (Final Report)

This report is a final deliverable for project 81966: Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters (CRADA 625) Commercial heat pump water heater (CHPWH) systems can significantly improve the energy efficiency of service water heating (SWH), aka domestic hot water (DHW), in commercial and multifamily buildings but have not yet achieved widespread adoption due to pricing, complexity, and perceived risk factors. The goal of this project – Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial HPWHs (Scaling Up) – was to demonstrate and validate a holistic systems approach for CHPWHs that de-risks the technology, creating a reliable, cost-effective, and repeatable approach to CHPWH deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moving Zero Energy Office Buildings to the Mainstream: Establishing Design Guidelines and Energy Targets: Preprint

Office buildings represent a significant portion of the commercial sector and are ideal candidates to lead the market towards achieving zero energy or zero energy ready buildings. The variety of sizes and uses for office buildings make them challenging to determine set design guidance that can be deployed across the market. A project committee for ASHRAE’s Zero Energy - Advanced Energy Design Guide (ZE-AEDG) for small and medium office buildings , comprised of members from five major national associations with market-pull in commercial buildings, created design guidance for achieving zero energy office buildings for new construction and major retrofit. This design guidance focuses on the process, providing a pathway for both office owners and design teams to achieve zero energy status. Energy use intensity targets range from 16 kBtu/ft²·yr to 36 kBtu/ft²·yr for the different climate zones were established such that office buildings can be “zero-ready,” that is, having low energy consumption that can easily be offset with renewables, preferably on-site. The design guidance was rooted in extensive energy modeling, as well as case studies of actual office buildings that have achieved high levels of energy performance and met zero energy or zero energy ready status. A unique aspect of the zero-energy guide is that it is not compared against a baseline but focuses on achieving an absolute target. The paper presents process of creating the targets, the selection of strategies to achieve the targets, and sample case studies that show how the cost-sensitive solutions are achievable for the design community. It also presents outreach strategies to deploy market achievable zero energy measures.

buildings↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

National Cost-effectiveness of ANSI/ASHRAE/IES Standard 90.1-2016

The purpose of this analysis is to examine the cost-effectiveness of the 2016 edition of ANSI/ASHRAE/IES Standard 90.1 (ASHRAE 2016). Standard 90.1 is developed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard Standing Project Committee (SSPC) 90.1. It is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833). PNNL analyzed the cost-effectiveness of changes in Standard 90.1 from 90.1-2013 to 90.1-2016, as applied in commercial buildings across the United States. During the development of new editions of Standard 90.1, the cost-effectiveness of individual changes (addenda) is often calculated to support the deliberations of ASHRAE Standard Standing Project Committee (SSPC) 90.1. The ASHRAE process, however, does not include analysis of the cost-effectiveness of the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting State and local governments. Providing States with an analysis of cost-effectiveness may encourage more rapid adoption of newer editions of energy codes based on Standard 90.1. This information may also inform the development of future editions of Standard 90.1. To establish the cost-effectiveness of Standard 90.1-2016, three main tasks were addressed: (1) Identification of building elements impacted by the updated standard; (2) Allocation of associated installation, maintenance, and replacement costs; and (3) Cost-effectiveness analysis of required changes In addition to installation, maintenance, and replacement costs, energy cost differences were needed to determine cost-effectiveness. The energy costs for each edition of Standard 90.1 were determined previously under the development of Standard 90.1-2016, as described below. The current analysis builds on the previous PNNL analysis (as outlined in Section 5.2) of the energy use and energy cost saving impacts of Standard 90.1-2016 compared to previous editions. The overall energy savings analysis of Standard 90.1 utilized a suite of 16 prototype EnergyPlus building models in 15 climate locations representing all eight U.S. climate zones. Detailed methodology and overall energy saving results from Standard 90.1-2016 are documented in the DOE technical report titled Energy Savings Analysis: ANSI/ASHRAE/IES Standard 90.1-2016 (DOE. 2018b).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building-Integrated Microscale Sensors for CO 2 -Level Monitoring

This research effort enabled the development of new classes of small-scale sensing systems that use mass and/or electrochemical sensors to detect the presence of carbon dioxide (CO 2 ). The concentration of this gas within the indoor environment is an important metric, as it can help enable the use of variable speed ventilation fans in commercial and governmental buildings, thus saving a significant amount of energy. Furthermore, there is a pressing need for enhanced CO 2 sensing to improve the comfort and productivity of people in commercial and government buildings, including academic spaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commercial Zero Code Plug-In: Zero Energy and Operational Emissions Overlay for Model Energy Codes (Technical Brief)

Model energy codes (MEC) describe requirements needed to demonstrate building energy performance compliance. They can be readily adopted by states and local jurisdictions to support desirable energy efficiency investment in new buildings and major renovations. This report provides commercial building energy code language as an overlay to current MEC, which is recognized by the U.S. DOE as ASHRAE Standard 90.1 2022. The code language provides a performance-based compliance path for achieving net zero energy or net zero operational energy emissions buildings with MEC. The path requires meeting two compliance metric target values: 1) a required minimum level of efficiency and 2) a measure of zero energy or emissions. The supporting documentation illustrates the magnitude of needed efficiency improvement and the additional offsets to be achieved from renewable energy sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Paving the Way for Net Zero Energy Codes through Performance Based Approaches

The prescriptive path is the most widely used approach for commercial code compliance in the United States. However, to achieve near-term net zero energy performance that many stakeholders in the buildings industry desire, it is clear that energy codes will need to transition from prescriptive to performance-based approaches. However, that transition is not without potential pitfalls. Among the concerns expressed by stakeholders are added complexity and cost, lack of confidence in energy modeling results, gamesmanship on the part of applicants, lack or qualified reviewers, challenges in promoting de-carbonization, and the inequity of trading long lived envelope efficiency for short lived measures such as building controls. This paper will discuss multiple approaches being evaluated and implemented by Pacific Northwest National Laboratory to improve the usability of the performance-based approach for both code compliance and beyond code programs to meet aggressive energy savings targets. A 'system performance' approach provides a simpler approach compared to whole building performance, while keeping tradeoffs limited to specific building systems. A simplified whole-building performance-based approach for small commercial buildings can cost effectively achieve deeper savings for buildings that typically follow the prescriptive compliance approach. Improved reporting and verification processes applied to the traditional performance path can provide greater confidence in simulation results and facilitate adoption of performance-based approaches. Prescriptive packages provide prescriptive solutions while targeting specific performance thresholds. This paper discusses the progress being made with each of these approaches and provides examples of their implementation in energy codes and beyond code programs.

Performance Based Codes, Appendix G, PRM, TSPR, Sy↗

Evaluation of Rooftop Solar Potential in Chernihiv and Lviv, Ukraine, and Efficacy of High-Resolution 3D Data Digital Twins [Slides]

NREL evaluated rooftop solar photovoltaic (PV) siting opportunities in the cities of Chernihiv and Lviv, Ukraine, leveraging very-high-resolution 3D elevation data to calculate technical potential. The study assessed total rooftop solar capacity and annual energy production. In Chernihiv and Lviv, 116,503 buildings were analyzed for their rooftop solar potential. The buildings in the study areas include a mixture of residential, commercial, and industrial buildings, characterized by diverse roof shapes and sizes. The total estimated rooftop solar capacity is 332 MWDC in Chernihiv and 873 MWDC in Lviv with annual energy production up to 376.2 GWhDC in Chernihiv and 995.5 GWhDC in Lviv. This accounting provides a clear estimate of the potential rooftop solar installations that could be realized under optimal conditions, considering both technical constraints and the geographic distribution of available rooftop space. Related to Russia's invasion of Ukraine, NREL estimates loss from buildings damaged or destroyed of 2,754 buildings, 20.15 MWDC of capacity, and 22,869 MWhDC of annual energy production in Chernihiv as well as a loss of 1,316 buildings, 34.49 MWDC of capacity, and 39,369 MWhDC of annual energy production in Lviv. The study also assessed the feasibility of adapting this methodology on a national scale using either simulated digital surface models (DSMs) or a digital twin approach. While the very-high-resolution DSM provided more precise results, the simulated DSM demonstrated reasonable accuracy for broader applications in modeling aggregated distributed solar supply. The feasibility of using a digital twin for Ukraine's national rooftop solar potential is considered promising, with certain limitations in areas with highly variable building stock and heavy war damage.

14 SOLAR ENERGY↗

2019 ASHRAE Handbook: HVAC Applications - Chapter 37 - Energy Use and Management

Handbook is a highly-regarded engineers reference book for heating, ventilating, air conditioning, and energy engineers. Building energy and water use metrics were developed for 53 commercial and residential building types. Supporting narrative was drafted and provided along with multiple tables of building performance metrics for publication in this ASHRAE handbook. ORNL (T. Sharp) developed the building performance metrics in Tables 2, 3, and 4 and authored the narrative about them. T. Sharp also authored the section on "Benchmarking Water Use" and developed building water use metrics published in Table 5.

Sharp, Terry↗

Making Data-Driven Policy Decisions for the Nation’s First Building Energy Performance Standards

Nearly every major U.S. city has committed itself to ambitious climate action goals – for Washington, DC this means a 50 percent reduction in greenhouse gases by 2032 and carbon neutrality by 2050. In support of these goals, Washington, DC has passed one of the most aggressive and practical climate action bills in the nation—with the Clean Energy DC Omnibus Act, DC became the first city in the U.S. to adopt energy performance standards for existing buildings. DC’s Building Energy Performance Standards (BEPS) require energy efficiency improvements for all commercial and multifamily buildings that do not meet a sector-specific minimum ENERGY STAR score or equivalent metric, with iterative compliance cycles every five years that will accelerate the pace of whole building retrofits. This paper explores this revolutionary policy framework and uses two data analysis projects that DC conducted to evaluate the potential impact of the BEPS and move towards carbon neutrality. First, we analyze the potential energy savings and greenhouse gas reductions, as well as potential cost impacts, from the implementation of a BEPS policy in DC We then examine the role of BEPS in a carbon neutrality strategy, how BEPS savings iterate over time, and what additional existing building improvements will be driven by the gravitational pull of new building codes on median performance. The paper highlights the benefits and limitations of such data-driven approaches to support policy decisions. Finally, we will review ongoing BEPS implementation, including expected policy directions, critical supportive programs, and lessons learned to date.

Bergfeld, Katie↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Securing Grid-interactive Efficient Buildings (GEB) through Cyber Defense and Resilient System (CYDRES)

The DOE CYDRES project is driven by the urgent need to address critical research gaps in the domain of cyber-physical security of smart buildings, including Grid-interactive Efficient Buildings (GEBs). CYDRES, a real-time advanced building resilient platform, aims to enhance the cyber-attack-immune capabilities of buildings through multi-layered prevention, detection, and adaptation mechanisms. CYDRES consists of five key modules: a multi-layer network analyzer, an Automatic Fault Detection, Diagnosis, and Prognosis (AFDDP) framework, an intelligent mode selector, a cyber-resilient control framework, and a situation awareness platform. The Network Analyzer employs a data-driven framework that includes a protocol state learning tool and a CRF (Conditional Random Field) command validator. In Hardware-In-the-Loop (HIL) testbeds, it achieved 100% detection accuracy with a false alarm rate of 3%, validating its efficacy in identifying selected cyber-attacks. The AFDDP framework leverages pattern matching, PCA (Principal Component Analysis)-based strategies, and a DBN (Dynamic Bayesian Network)-based fault diagnosis approach to pinpoint the causes of physical system abnormalities using Building Automation System (BAS) data. In HIL experiments, the AFDDP module attained a detection accuracy of over 95% with a false alarm rate below 7%. Additionally, the fault detector utilized machine learning (Random Forest) and deep learning (Multi-Layer Perceptron) methods with acoustic sensor data to achieve a 100% fault detection accuracy in Heating, Ventilation, and Air-Conditioning (HVAC) equipment. The Mode Selector offered real-time impact analysis, allowing immediate actions to protect BASs in the face of emerging threats. The cyber-resilient control framework included an adaptive Model Predictive Control (MPC) and a measurement compensator, reducing temperature violations by up to 94% and improving the total demand flexibility by up to 70% in HIL experiments. Such HIL experiments covered a cyber-attack case and a physical fault case, showcasing CYDRES’ efficiency in maintaining operational continuity during threats. The situation awareness platform in Grafana enhanced real-time threat detection and response visualization, augmenting the operational awareness for building operators. CYDRES demonstrated high technical effectiveness in various test scenarios, particularly in HIL environments. The project's phased development approach ensured efficient use of resources, highlighting its practical feasibility and readiness for commercialization. By enhancing the security and resilience of building operations, CYDRES represents a significant advance in mitigating risks associated with cyber-physical systems, thereby enhancing public confidence in the safety of modern building infrastructure. Future directions for the project include expanding testing protocols, refining AFDDP methodologies, exploring more comprehensive resilient control strategies, and testing in real commercial buildings.

42 ENGINEERING↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovations in Sensors and Controls for Building Energy Management: Research and Development Opportunities Report for Emerging Technologies

Sensors, actuators, and controllers, which collectively serve as the backbone of cyberphysical systems for building energy management, are one of the core technical areas of investment for achieving the U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) goals for energy affordability in the national building stock - both commercial and residential. In fact, an aggregated annual energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms. energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low Carbon Technology Strategies: Commercial Kitchen

This document is a supplement to Low Carbon Technology Strategies for building types that typically include commercial kitchens. It includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon commercial kitchens.

carbon reduction, carbon emissions, low carbon, de↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗