Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Certified”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Solar Access to Public Capital (SAPC) Working Group: Best Practices in Commercial and Industrial (C&I) Solar Photovoltaic System Installation; Period of Performance: November 28, 2014-September 1, 2015

This Best Practices in Commercial and Industrial Solar Photovoltaic System Installation Guide is the second of a series of guides designed to standardize and improve solar asset transparency for investors and rating agencies, provide an industry framework for quality management, and reduce transaction costs in the solar asset securitization process. The Best Practices in C&I PV System Installation Guide is intended to outline the minimum requirements for commercial and industrial solar project developments. Adherence to the guide is voluntary. Providers that adhere to the guide are responsible for self-certifying that they have fulfilled the guide requirements. Investors and rating agencies should verify compliance.

14 SOLAR ENERGY↗

Brookfield Homes Passive House Performance Evaluation

In 2012-2013, IBACOS worked with a builder, Brookfield Homes in Denver, Colorado, to design and construct a Passive House certified model home. IBACOS used several modeling programs and calculation methods to complete the final design package along with Brookfield's architect KGA Studio. This design package included upgrades to the thermal enclosure, basement insulation, windows, and heating, ventilation, and air conditioning. Short-term performance testing in the Passive House was done during construction and after construction. Testing with a blower door indicated that whole-building air leakage to the outside was 324 CFM and 0.60 ACH50. The other two test homes had little short-term testing done post-construction by the local energy rater. IBACOS then monitored the energy consumption and whole-house comfort conditions of that occupied Passive House after one year of operation and compared the monitoring results to those for two other occupied test houses in the same area with similar square footage but slightly different floor plans. IBACOS also assisted the builder, Brookfield Homes, in researching design scenarios for Zero Energy Ready Home and ENERGY STAR acceptance levels. IBACOS also assisted Brookfield in conceptualizing product for Denver's Brighton Heights area. Brookfield was considering building to Zero Energy Ready Home standards in that location. IBACOS provided strategies that Brookfield may draw from in the event the builder chooses to pursue a Zero Energy Ready Home plan for that market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CSR behavior and aging model for the Viton© Fluorelastomer O-rings in the 9975 shipping package

The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report for Packaging (SARP) requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to provide a technical basis to extend that period. This report describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both GLT and GLT-S compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior. The CSR behavior of O-rings was evaluated at temperatures from 175 to 400 °F. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 156 °F). The predictive model developed from the CSR data conservatively indicates a service life of approximately 37 years for Viton GLT O-rings at the maximum effective service temperature of 156 °F. The estimated service life for Viton GLT-S O-rings is significantly longer.

36 MATERIALS SCIENCE↗

Brookfield Homes Passive House Performance Evaluation

In 2012-2013, IBACOS worked with a builder, Brookfield Homes in Denver, Colorado, to design and construct a Passive House certified model home. IBACOS used several modeling programs and calculation methods to complete the final design package along with Brookfield's architect KGA Studio. This design package included upgrades to the thermal enclosure, basement insulation, windows, and heating, ventilation, and air conditioning. Short-term performance testing in the Passive House was done during construction and after construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes -- Habitat for Humanity The Woods

The Woods is a Habitat for Humanity (HFH) community of ENERGY STAR Homes Northwest (ESHNW)-certified homes located in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report, and includes significant billing analysis and cost effectiveness research from a collaborative, ongoing Ductless Heat Pump (DHP)research effort for Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH. Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Looking For Value in All The Wrong Places. Toward Expanded Consideration of Green and High Performance Attributes in Non-residential Property Appraisals in the United States

Large numbers of commercial buildings have sought to improve their energy and environmental performance, with half of all leasable U.S. offices now designated at some level of “green”. All proper/es fall somewhere on the green/high-­performance spectrum (above and below average) whether or not they bear a formal label or ra/ng.1 Variations in the level of performance can either positively or negatively influence value. This component of value can be shaped by many factors, from utility costs to tenant/owner preferences that translate into income (rent levels, vacancy rates, lease-­up /mes, etc.). Occupant perceptions of indoor environmental quality are another potential influence on value. While there has been little uptake of this thinking by practicing appraisers, the increased prevalence of green/HP practices combined with concerns about appraiser competency are compelling the industry to adapt their traditional techniques to this new driver of value. However, the overly narrow focus of policymakers on appraisal of labeled or rated exemplary buildings (e.g., LEED or ENERGY STAR Certified) represents a significant missed opportunity. Any level of green or energy performance can in fact influence value, including below-­average performance (a.k.a. “brown discount”), irrespec/ve of whether or not the building has been formally rated. Another surmountable challenge is the limitations to non-­appraisers’ understanding of the appraisal process (and constraints therein). A crucial byproduct of this is unrealistic expectations of what appraisers can and will do in the marketplace. This report identifies opportunities for catalyzing improvement of the green/HP appraisal process, which apply to all involved actors—from owner, report-­ordering client, the appraiser, and the appraisal reviewer—and fostering more demand for appraisals that recognize green/HP property attributes. The intended audience is primarily the public policy community and other stakeholders outside the formal appraisal community who can contribute to the broader effort to advance professional practces. The discussion begins with a descripton of the appraisal process and the points at which green/HP consideratons can enter the analysis. A series of major barriers to better practces are identfied along with approaches to reducing them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A New Appraisal- Lessons from the History of Efforts to Value Green and High-Performance Home Attributes in the United States

Rigorous consideration of green and high-performance (“green/HP”) features is rarely included in the property valuation process._ To help illuminate why this is the case, this report takes stock of the history of efforts to improve practices, and identifies barriers that have emerged and opportunities for overcoming them. Particular emphasis is placed on what energy and environmental policymakers and other stakeholders outside the appraisal community can contribute to the broader effort to advance professional practices. The history has unfolded in parallel with turbulent periods in the housing market for which appraisers and their customers are deemed to share responsibility, followed by cycles of regulations, siloing of appraisers in the name of professional integrity, and commoditization of the valuation process itself. This pattern has important ramifications for aspirations that appraisers engage more fully in identifying and valuing the green/HP characteristics of homes. On the one hand, it is legally and ethically incumbent on appraisers to do so, yet on the other hand it is perceived as a risky avenue to follow. Risks arise where findings can be challenged as either over- or under-stating value, together with a market environment in which the complexity of their assignments increases despite downward pressure on appraiser fees. While efforts to address green/HP considerations date back to the early 1980s, the vast majority of activity has taken place within the past five years. Many players have engaged in the efforts to promote improved valuation practices. These include the Appraisal Foundation, The Appraisal Institute, Colorado Energy Office, Earth Advantage, EcoBroker, Elevate Energy, Fannie Mae, Federal Housing Administration, Home Innovation Research Labs, The Institute for Market Transformation, Northwest Energy Efficiency Alliance, National Association of Homebuilders, National Association of State Energy Officials, National Association of Appraisers, RESNET, USEPA, USDOE and its National Laboratories, the U.S. Green Buildings Council, and the Vermont Green Homes Alliance. Many activities have resulted, ranging from trainings, to data-gathering instruments, and the emergence of a literature attempting to statistically isolate the effects of green/HP characteristics on home values. In some cases, the results of studies have been overgeneralized and oversold, and embodied flawed methods. Although the green/HP community has encouraged appraisers to focus on exemplary buildings (e.g., LEED or ENERGY STAR Certified), any level of green or energy performance can in fact influence value, including below-average performance (a.k.a. “brown discount”), irrespective of whether or not the building has been formally rated. This overly narrow focus represents a significant missed opportunity. Other surmountable challenges include limitations to non-appraisers’ understanding of the appraisal process (and practical constraints therein). A byproduct of this can be unrealistic expectations of what appraisers can and will do in the marketplace. These challenges notwithstanding, the environment for moving forward has improved. There is better data today (a critical need); expanded efforts to disclose energy use information (characteristics, consumption, bills); improved and more pervasive building energy codes, building rating and labeling initiatives; and a host of federal, state, and local policies that have collectively brought green/HP practices much more into the mainstream. Meanwhile, a renewed focus on professional standards of care and competency for assessing green/HP homes make it increasingly important for appraisers to consider these factors in their assignments. Despite the past four decades of studies, there is little if any discernible uptake of these practices by the appraisal practice at large. It would behoove interested parties to step back and consider what new strategies might be productive. A key element of any new plan should be to reset the nature of interactions with the industry, with the goal a more collaborative, two-way discussion to help improve outsiders’ understanding of the valuation process. It is not only the appraiser that needs to be engaged and could benefit from awareness raising. Homeowners, builders, lenders, utilities, insurance companies should also provide input on how green/HP factors impact property valuations and ways to accurately reflect these considerations in appraisals and real estate transactions more broadly. Given extensive inertia within the appraisal industry and a mixed history of interactions with the non-appraisal stakeholders, it is unlikely that the status quo will achieve much unless followed with more coordinated and persistent efforts. Workshops, studies, and memoranda of understanding will not on their own have much impact, and do not address deeper structural issues. Expectations are often unrealistic and not attentive to real-world constraints faced by appraisers. The report identifies key barriers impeding more thorough consideration of green/HP factors in residential real estate appraisals, and solutions for mitigating them. Barriers • Although industry standards of practice caution against bias of any sort, a skeptical predisposition towards “green” is reinforced by information deficiencies. • Information deficiencies result from the lack or difficulty of obtaining usable data on green/HP features in subject properties as well as valid sales comparisons or cashflow analyses. • Competency deficiencies, such as lack of conversancy in relevant technical topics, leads to oversights, and disjointed treatment of relevant information. • Time/cost pressure and process commoditization (e.g., template-based approaches) result from highly constrained budgets, quick turn-around times expected of appraisers, and standardized practices that were not developed with green/HP considerations in mind. • Professional differences between appraisers and sustainability professionals include divergent objectives, the former being market observers and the latter market influencers. • Risk aversion arises from multiple concerns including veracity, accuracy, and persistence of energy data, impacts of operational choices, new sources of appraiser liability associated with green/HP assessments, industry pressures not to over-value buildings or suggestion of bias, and concern about spending non-billable time on complex assignments. • A public policy vacuum has been created by disjointed and uncoordinated efforts from public-sector stakeholders, insufficient efforts to discuss and understand the appraisal industry and process, and a perception by some valuation professionals that green/HP is oversold. Opportunities • Elevating the competency of appraisers can be achieved through a combination of improved industry standards of care and equal-access training and professional development offerings. • Development of better information resources must focus on building-level information that provides robust documentation as well as aggregate sales-comparison data and other contextual information such as local codes, typical upgrade costs, energy prices, etc. • Improved energy benchmarking and rating tools could provide appraisers with information more well-adapted to their particular needs, which differ from those of typical audiences such as energy managers. • Better characterizing and managing risk will enable appraisers to cope with uncertainties in performance information, and help identify where risks may be introduced or mitigated by green/HP features, including higher costs or obsolescence of poorly-performing buildings. • Integrating disaster resilience and sustainability in appraisals would recognize important synergisms among these features, including durability and ability of green/HP buildings to better withstand external hazards. • Mitigating the problem of additional time/cost for performing assignments is an essential need that can be addressed by providing easier access to information and analytic procedures, perhaps coupled with new resources to defray the associated costs. • Enhancing demand for improved appraisals is a fundamental need, and depends on owners, developers, lenders, and others soliciting competent appraisers to perform scopes that expressly call out green/HP considerations, and to critically review the work product for compliance before acceptance. • Engaging new market participants, such as energy utilities and insurance companies can ensure fuller representation and participation of market stakeholders already engaged in green/HP activities and capable of furnishing valuable data and managing associated risks. Cutting across these individual activities, there is a need for outside stakeholders to formulate and follow a roadmap instead of piecemeal initiatives, bridging the professional/cultural divide between appraisers and green/HP communities, and tracking progress in order to know what is working. A more coherent communication and training strategy is needed, as the appraisal industry is highly fragmented, with two-thirds of appraisers opting out of membership in trade associations. In sum, while there is no silver bullet for advancing the practice of valuing green/HP features, there are concrete opportunities. Parties seeking solutions must identify barriers they wish to address and select from among potential initiatives that map to those barriers. Close collaboration with the appraisal community is critical, as non-appraisers have historically obtained limited traction with this industry due to lack of understanding of the nuances involved in the valuation profession. Large organizations and agencies should have a united approach; the perception or reality of a fragmented and uncoordinated strategy is unsettling for prospective partners in the appraisal industry. This requires improved communication and education within and among these communities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LX-17-1 Stockpile Returned Material Lot Comparison

Many different lots of LX-17 have been produced over the years. Two varieties of LX-17, LX-17-0 and LX-17-1, have at one point or another been a part of the Livermore stockpile systems. LX-17-0 was made with dry-aminated TATB whereas LX-17-1 was made with wet-aminated TATB. Both versions have the same TATB to Kel-F 800 mass ratio of 92.5%/7.5%. Both kinds of LX-17 were formulated at Holston during the late 1970s or early to mid-1980s and were certified to have met the necessary specifications that cover the purity, particle size range, explosive to binder ratio, etc. In recent years, Trevor Willy and others have performed a detailed evaluation of solid parts made from each of the LX-17 lots manufactured at Holston. Using the Advanced Light Source at LBNL, Willey and his colleagues radiographed many samples from isostatic pressings using the same scanning conditions. In their investigation they identified that even though the bulk composition can be the same, there may exist a large spread in how smoothly the TATB and binder were distributed within the radiographed volume of different lots of material.1 Overall, the dry-aminated TATB-based material, LX-17-0, had a smooth TATB and binder distribution, whereas the wet-aminated TATB-based LX-17-1 showed a wide range of binder distributions. The results for five different LX-17-1 lots are shown in Figure 1. The wide variation in material distribution has raised the question about whether or not this sort variability will cause significant differences in mechanical behavior.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Direct Drive Wave Energy Buoy

This Project aims to satisfy objectives of the DOE’s Water Power Program by completing a system detailed design (SDD) and other important activities in the first phase of a utility-scale grid-connected ocean wave energy demonstration. In early 2012, Columbia Power (CPwr) had determined that further cost and performance optimization was necessary in order to commercialize its StingRAY wave energy converter (WEC). CPwr’s progress toward commercialization, and the requisite technology development path, were focused on transitioning toward a commercial-scale demonstration. This path required significant investment to be successful, and the justification for this investment required improved annual energy production (AEP) and lower capital costs. Engineering solutions were developed to address these technical and cost challenges, incorporated into a proposal to the US Department of Energy (DOE), and then adapted to form the technical content and statement of project objectives of the resulting Project (DE-EE0005930). Through Project cost-sharing and technical collaboration between DOE and CPwr, and technical collaboration with Oregon State University (OSU), National Renewable Energy Lab (NREL) and other Project partners, we have demonstrated experimentally that these conceptual improvements have merit and made significant progress towards a certified WEC system design at a selected and contracted deployment site at the Wave Energy Test Site (WETS) at the Marine Corps Base in Oahu, HI (MCBH).

16 TIDAL AND WAVE POWER↗

Supply Chain-Based Solution to Prevent Fuel Tax Evasion: Final Report

The primary source of funding for the United States transportation system is derived from motor fuel and other highway use taxes. Loss of revenue attributed to fuel-tax evasion has been assessed to be somewhere between 1 billion and 3 billion per year. Any solution that addresses this problem needs to include not only the tax-collection agencies and auditors, but also the carriers transporting oil products and the carriers customers. This report presents a system developed by the Oak Ridge National Laboratory (ORNL) for the Federal Highway Administration which has the potential to reduce or eliminate many fuel-tax evasion schemes. The solution balances the needs of tax-auditors and those of the fuel-hauling companies and their customers. The system has three main components. The on-board subsystem combined sensors, tracking and communication devices, and software (the on-board Evidential Reasoning System, or obERS) to detect, monitor, and geo-locate the transfer of fuel among different locations. The back office sub-system (boERS) used self-learning algorithms to determine the legitimacy of the fuel loading and offloading (important for tax auditors) and detect potential illicit operations such as fuel theft (important for carriers and their customers, and may justify the deployment costs). The third sub-system, the Fuel Distribution and Auditing System or FDAS, is a centralized database, which together with a user interface allows tax auditors to query the data submitted by the fuel-hauling companies and correlate different parameters to quickly identify any anomalies. Industry partners included Barger Transport of Weber City, Virginia (fleet); Air-Weigh, of Eugene, Oregon (and their wires and harnesses); Liquid Bulk Tank (LBT) of Omaha, Nebraska (three five-compartment trailers); and Innovative Software Engineering (ISE) of Coralville, Iowa(on-board telematics device and back-office system). ORNL conducted a pilot test with the three instrumented vehicles collecting real-world data during an eight-month period (October 2014 to June 2015). The vehicles logged a total of 375,000 miles and transported more than 7.5 million gallons of fuel. The drivers entered information on the telematics device about 77% of the time, with about 15% (10%) of the data showing at least one compartment with loading (offloading) valve activity, but not driver information entry for that compartment. Seven events (or about 0.7% of the trips) were identified by the boERS as having a missing fuel diversion number. The solution developed and tested in the pilot test had federal- and state-level tax auditors as its main audience. Nonetheless, the technology has to be adopted by the fuel carriers and therefore the solution had to address the needs of fuel-hauling companies and their customers (i.e., fuel theft and cocktailing). Sensors in the hatches allowed the obERS recognize when one of those were opened (always a suspicious activity, unless it happens at locations where maintenance is performed on the vehicle). The fuel-theft issue was addressed by a self-learning algorithm deployed on the boERS that continuously processed the data from the field to construct probability distributions of measures such as elapsed time of fuel loading and offloading by driver, vehicle, and compartment, valve actuation sequence, elapsed time between the first two valve actuations (by driver, compartment, and location), and other parameters. Probability thresholds, which can be set up by the carrier, determined how to classify the observed events. The boERS also kept track of valve sequencing at a given location and analyzed these actuations to help identify any suspicious activities. Technical and economic recommendations include: a) simplification of the driver data-entry task; b) reduction of system deployment cost; c) addition of capabilities that make the system more appealing to industry (i.e., identify and avoid fuel misdelivery); and d) incorporation of additional capabilities to the FDAS. Path to commercialization recommendations include: a) identify a company willing to further develop, test, and certify a hardened system with a price point the market will bear; b).transfer ERS to licensee; c) establish a fleet or fleets who want this technology for carrier benefits or trailer manufacturer who wants to offer it as optional technology; and d) identify a location for the deployment of FDAS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

L2 Milestone 5433: Characterization of Dynamic Behavior of AM and Conventionally Processed Stainless Steel (316L and 304L)

For additive manufacturing (AM) of metallic materials, the certification and qualification paradigm needs to evolve as there currently exists no broadly accepted “ASTM- or DIN-type” additive manufacturing certified process or AM-material produced specifications. Accordingly, design, manufacture, and thereafter implementation and insertion of AM materials to meet engineering applications requires detailed quantification of the constitutive (strength and damage) properties of these evolving materials, across the spectrum of metallic AM methods, in comparison/contrast to conventionally-manufactured metals and alloys. This report summarizes the 316L SS research results and presents initial results of the follow-on study of 304L SS. For the AM-316L SS investigation, cylindrical samples of 316L SS were produced using a LENS MR-7 laser additive manufacturing system from Optomec (Albuquerque, NM) equipped with a 1kW Yb-fiber laser. The microstructure of the AM-316L SS was characterized in both the “as-built” Additively Manufactured state and following a heat-treatment designed to obtain full recrystallization to facilitate comparison with annealed wrought 316L SS. The dynamic shock-loading-induced damage evolution and failure response of all three 316L SS materials was quantified using flyer-plate impact driven spallation experiments at peak stresses of 4.5 and 6.35 GPa. The results of these studies are reported in detail in the first section of the report. Publication of the 316L SS results in an archival journal is planned. Following on from the 316L SS completed work, initial results on a study of AM 304L SS are in progress and presented herein. Preliminary results on the structure/dynamic spallation property behavior of AM-304L SS fabricated using both the directed-energy LENS and an EOS powder-bed AM techniques in comparison to wrought 304L SS is detailed in this Level 2 Milestone report.

316L SS↗

Secondary Containment Design for the LLNL B801 Diala Oil Tank

Design is to add an extension to the secondary containment of tank T1-A3 at building 801. Piping from the inner tank penetrates the secondary containment tank below the liquid level of the primary tank. To meet Oil Pollution Prevention Regulation 40 CFR 120.7 the single wall piping needs to be provided with secondary containment. Steel Tank Institute (STI) conference publication states: §112.3(d)(1)(iii) –SPCC Plan requirements- Systems shall be designed in accordance with good engineering practice, including consideration of applicable industry standards and that procedures for required inspections and testing have been established. Section 112.7(a)(2) allows for deviations from specific rule requirements, provided the Owner/operator responsible to select, document and implement alternate measure and a PE certifies the SPCC Plan in accordance with good engineering practices, including consideration of industry standards

42 ENGINEERING↗

Nevada Renewable Energy Training Project: Geothermal Power Plant Operators

The purpose of this project was to develop and institute a training program for certified geothermal power plant operators (GPO). An advisory board consisting of subject matter experts from the geothermal energy industry and academia identified the critical skill sets required for this profession. A 34-credit Certificate of Achievement (COA), Geothermal Power Plant Operator, was developed using eight existing courses and developing five new courses. Approval from the Nevada System of Higher Education Board of Regents was obtained. A 2,400 sq. ft. geothermal/fluid mechanics laboratory and a 3,000 sq. ft. outdoor demonstration laboratory were constructed for hands-on training. Students also participated in field trips to geothermal power plants in the region. The majority of students were able to complete the program in 2-3 semesters, depending on their level of math proficiency. Additionally the COA allowed students to continue to an Associate of Applied Science (AAS), Energy Technologies with an emphasis in Geothermal Energy (26 additional credits), if they desired. The COA and AAS are stackable degrees, which provide students with an ongoing career pathway. Articulation agreements with other NSHE institutions provide students with additional opportunities to pursue a Bachelor of Applied Science in Management or Instrumentation. Job placement for COA graduates has been excellent.

15 GEOTHERMAL ENERGY↗

Classification of the Z-Pinch Waste Stream as Low-Level Waste for Disposal

The purpose of this document is to describe the waste stream from Z-Pinch Residual Waste Project that due to worker safety concerns and operational efficiency is a candidate for blending Transuranic and low level waste together and can be safely packaged as low-level waste consistent with DOE Order 435.1 requirements and NRC guidance 10 CFR 61.42. This waste stream consists of the Pu-ICE post-shot containment systems, including plutonium targets, generated from the Z Machine experiments requested by LANL and conducted by SNL/NM. In the past, this TRU waste was shipped back to LANL after Sandia sends the TRU data package to LANL to certify the characterization (by CCP), transport and disposition at WIPP (CBFO) per LANL MOU-0066. The Low Level Waste is managed, characterized, shipped and disposed of at NNSS by SNL/NM per Sandia MOU # 11-S-560.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chapter 24: Strategic Energy Management (SEM) Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

Strategic energy management (SEM) focuses on achieving energy-efficiency improvements through systematic and planned changes in facility operations, maintenance, and behaviors (OM&B) and capital equipment upgrades in large energy-using facilities, including industrial buildings, commercial buildings, and multi-facility organizations such as campuses or communities. Facilities can institute a spectrum of SEM actions, ranging from a simple process for regularly identifying energy-savings actions, to establishing a formal, third-party recognized or certified SEM framework for continuous improvement of energy performance. In general, SEM programs that would be considered part of a utility program will contain a set of energy-reducing goals, principles, and practices emphasizing continuous improvements in energy performance or savings through energy management and an energy management system (EnMS).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

1QCY17 Saltstone waste characterization analysis

In the first quarter of calendar year 2017, a salt solution sample was collected from Tank 50 on January 16, 2017 in order to meet South Carolina (SC) Regulation 61-107.19 Part I C, “Solid Waste Management: Solid Waste Landfills and Structural Fill – General Requirements” and the Saltstone Disposal Facility Class 3 Landfill Permit. The Savannah River National Laboratory (SRNL) was requested to prepare and ship saltstone samples to a United States Environmental Protection Agency (EPA) certified laboratory to perform the Toxicity Characteristic Leaching Procedure (TCLP) and subsequent characterization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Graphene-based filament material for thermal ionization

The use of graphene oxide materials for thermal ionization mass spectrometry analysis of plutonium and uranium has been investigated. Filament made from graphene oxide slurries have been 3-D printed. A method for attaching these filaments to commercial thermal ionization post assemblies has been devised. Resistive heating of the graphene based filaments under high vacuum showed stable operation in excess of 4 hours. Plutonium ion production has been observed in an initial set of filaments spiked with the Pu 128 Certified Reference Material.

36 MATERIALS SCIENCE↗

Synthesis and Crystal Structures of Volatile Neptunium(IV) β- Diketonates

Production of certified reference materials in support of domestic nuclear forensics programs require volatile precursors for introduction into electromagnetic isotopic separation instruments. β-diketone chelates of tetravalent actinides are known for their high volatility, but previously developed synthetic approaches require starting material (NpCl 4 ) that is prohibitively difficult and hazardous to prepare. An alternative strategy was developed here that uses controlled potential electrolysis to reduce neptunium to the tetravalent state in submolar concentrations of hydrochloric acid. Four different β-diketone ligands of varying degrees of fluorination were reacted with an aqueous solution of Np 4+ . Products of this reaction were characterized via X-ray diffraction and infrared spectroscopy, and were found to be neutral 8-coordinate complexes that adopt square antiprismatic crystal geometry. Synthesis of Np β-diketonates by this approach circumvents the necessity of using NpCl 4 in tetravalent Np coordination compound synthesis. The volatility of the complexes was assessed using thermogravimetric analysis, where the temperature of sublimation was determined to be in the range of 180° to 205° C. The extent of fluorination did not appreciably alter the sublimation temperature of the complex. Thermal decomposition of these compounds was not observed during sublimation. High volatility and thermal stability of Np β-diketonates make them an ideal candidate for gaseous introduction into isotopic separation instruments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗