Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Corrosion Preventive Compounds Lifetime Testing

Lifetime Testing of Corrosion Preventive Compounds (CPCs) was performed to quantify performance in the various environments to which the Space Shuttle Orbiter is exposed during a flight cycle. Three CPCs are approved for use on the Orbiter: HD Calcium Grease, Dinitrol AV-30, and Braycote 601 EF. These CPCs have been rigorously tested to prove that they mitigate corrosion in typical environments, but little information is available on how they perform in the unique combination of the coastal environment at the launch pad, the vacuum of low-earth orbit, and the extreme heat of reentry. Currently, there is no lifetime or reapplication schedule established for these compounds that is based on this combination of environmental conditions. Aluminum 2024 coupons were coated with the three CPCs and exposed to conditions that simulate the environments to which the Orbiter is exposed. Uncoated Aluminum 2024 coupons were exposed to the environmental conditions as a control. Visual inspection and Electro- Impedance Spectroscopy (EIS) were performed on the samples in order to determine the effectiveness of the CPCs. The samples were processed through five mission life cycles or until the visual inspection revealed the initiation of corrosion and EIS indicated severe degradation of the coating.

Hale, Stephanie M.↗

The Growth of Small Corrosion Fatigue Cracks in Alloy 7075

The corrosion fatigue crack growth characteristics of small (greater than 35 micrometers) surface and corner cracks in aluminum alloy 7075 is established. The early stage of crack growth is studied by performing in situ long focal length microscope (500×) crack length measurements in laboratory air and 1% sodium chloride (NaCl) environments. To quantify the "small crack effect" in the corrosive environment, the corrosion fatigue crack propagation behavior of small cracks is compared to long through-the-thickness cracks grown under identical experimental conditions. In salt water, long crack constant K(sub max) growth rates are similar to small crack da/dN.

Piascik, Robert S.↗

Cyclic Oxidation and Hot Corrosion of NiCrY-Coated Disk Superalloys

Powder metallurgy disk superalloys have been designed for higher engine operating temperatures through improvement of their strength and creep resistance. Yet, increasing disk application temperatures to 704 degrees Centigrade and higher could enhance oxidation and activate hot corrosion in harmful environments. Protective coatings could be necessary to mitigate such attack. Cylindrical coated specimens of disk superalloys LSHR and ME3 were subjected to thermal cycling to produce cyclic oxidation in air at a maximum temperature of 760 degrees Centigrade. The effects of substrate roughness and coating thickness on coating integrity after cyclic oxidation were considered. Selected coated samples that had cyclic oxidation were then subjected to accelerated hot corrosion tests. This cyclic oxidation did not impair the coating's resistance to subsequent hot corrosion pitting attack.

protective coating↗

Corrosion of Bare Carbon Steel as a Passive Sensor to Assess Moisture Availability for Biological Activity in Atacama Desert Soils

In this work we suggest the corrosion of polished bared metal coupons as a passive sensor to detect or identify the lower limit of water availability that could be suitable for biological activity in the Atacama Desert on soil or solid substrates. For this purpose, carbon steel coupons were deposited in selected sites along a west-east transect and removed at predetermined times for morphological inspection. The advantage of this procedure is that the attributes of the oxide layer (corrosion extent, morphology and oxide phases) can be considered as a fingerprint of the atmospheric moisture history at a given time interval. Two types of coupons were used, a long rectangular shape that are half-buried in a vertical position, and square shape that are deposited on the soil surface. The morphological attributes observed by SEM inspection is correlated to the so-called humectation time which is determined from local meteorological parameters. The main result is that the decreasing trend of atmospheric moisture along the transect is closely related to corrosion behavior and water soil penetration. For instance, while in the coastal site oxide phases formed on the coupon surface rapidly evolve to well- crystallized species, in the driest inland site Lomas Bayas only amorphous oxide is observed.

Caceres, Luis↗

ECLSS Universal Waste Management System (UWMS) Metal Materials Compatibility Study - Elgiloy: Electrochemical and Crevice Corrosion Evaluation

Electrochemical evaluations were conducted on samples of Elgiloy in support of the materials compatibility program for the Environmental Control and Life Support System (ECLSS). Results were compared alongside three previously tested metals: Titanium 6Al-4V, Inconel 625, and Hastelloy C276. Titanium exhibited the best results of all the metals, indicating superior corrosive nobility and galvanic protection properties. Elgiloy demonstrated anti-corrosion behavior which appeared to be superior to the two nickel-chromium alloys. For this current effort, the results have clearly shown that Elgiloy possesses excellent corrosion protection properties and is galvanically compatible with the other three metals in the subject test media.

Lee, R. E.↗

Stress Corrosion Evaluation of Elgiloy Alloy for the ISS ECLSS — Universal Waste Management System

Elgiloy® alloy (UNS R30003)—a spring material per AMS 5876D (reference 1)—is one among several alloys recently evaluated for stress corrosion cracking resistance in support of the International Space Station (ISS) Environmental Control and Life Support System (ECLSS). Elgiloy was evaluated particularly for its expected use in the Universal Waste Management System (described in references 2 and 3). Data for other alloys previously evaluated were reported in references 4 and 5. Materials included in reference 4 are Inconel 625, Hastelloy® C276, commercially pure titanium, titanium with 6% aluminum and 4% vanadium (Ti6Al4V), extra-low interstitial Ti6Al4V, and Cronidur 30. The results for Nitinol 60 are in reference 5. During the water recovery process, the metallic components fabricated from these materials are exposed to acidic solutions used for waste treatment. The purpose of the current and previous stress corrosion evaluations is to determine if these materials have adequate stress corrosion resistance.

Torres, Pablo D.↗

LCF Life of As-Deposited and Annealed NiCr-Y Coatings for Oxidation and Hot Corrosion Protection of Disk Alloys

Increasing temperatures in aero gas turbines is resulting in oxidation and hot corrosion attack of turbine disks. Since disks are sensitive to low cycle fatigue (LCF), any environmental attack, and especially hot corrosion pitting, can seriously degrade the life of the disk. Application of metallic coatings is one means of protecting disk alloys from this environmental attack. However, the presence of a metallic coating can degrade the LCF life of a disk alloy. Therefore, coatings must be designed which are not only resistant to oxidation and corrosion attack, but do not significantly degrade the LCF life of the alloy.Three different NiCr-Y coating compositions (29, 35.5, 44 wt.% Cr, all with 0.1 wt.% Y) were applied at two thicknesses by Plasma Enhanced Magnetron Sputtering (PEMS) to two similar Ni-based disk alloys. One Ni-35.5Cr-0.1Y coating also received a thin ZrO2 overcoat. The coated samples were also given a short thermal anneal in a low PO2 environment to encourage bonding of the coating and substrate as well as initiating formation of a chromia scale. Without further environmental exposure, the LCF life of coated and uncoated samples was evaluated at 760°C in air. The LCF lifetime of all coated samples was less than that of uncoated samples. The LCF life scaled with the Cr content and the high-Cr, thin coating showed the highest LCF life. Pre and post-test characterization of the various coatings, including identification of crack initiation sites, will be presented and the effect of the coating on the LCF life discussed.

low cycle fatigue↗

Pre-demonstration Development of Controlled-Release Corrosion Inhibitors and Healing Agents as Alternatives to Hexavalent Chromium

This Limited Scope Study was directed to achieve the following objectives:(1) Scale-up of materials that can meet MIL-PRF-23377 (solvent-based primer).(2) Provide evidence of resistance to aircraft alkaline cleaners and deicing fluids.(3) Provide formulation for initial ecological and toxicity screening.(4) Submit an interim report that will provide the basis for a future ESTCP demonstration effort.The encapsulation procedure for two corrosion inhibitors was scaled up from lab scale to 2.0 kg. This scale will accommodate high volume production of coatings with encapsulated corrosion inhibitors for large surface areas during a follow on ESTCP demonstration effort.Test results provided evidence of resistance to alkaline cleaners and aircraft deicing fluids and compliance with MIL-PRF-23377. All the MIL-PRF-23377 requirements were met with the exception of the adhesion requirement, in top coated panels, and the flexibility requirement. Work on solving these two problems will be done prior to validation and demonstration of the technology. An initial ecological and toxicity screening identified several factors that were not critical to the acceptance of the encapsulated corrosion inhibitor. This new technology will lead to environmentally friendly alternatives to hexavalent chromium that will enable DoD to protect its assets. Field demonstration, licensing, qualification, and commercialization will allow its real world utilization.

Calle, L. M.↗

LCF Life of NiCr-Y Coated Disk Alloys After Shot Peening, Oxidation and Hot Corrosion

In a prior companion study (Ref. 1), three different Ni-Cr coating compositions (29, 35.5, 45 wt% Cr) were applied at two thicknesses by Plasma Enhanced Magnetron Sputtering (PEMS) to two similar Ni-based disk alloys. One coating also received a thin ZrO2 overcoat. The low cycle fatigue (LCF) life of each coating was determined at 760 °C and was less than that of the uncoated specimens. In this followon effort, shot peening was examined as a means to improve the as-deposited coating morphology as well as impart a residual compressive stress in the near-surface region. After evaluating the effect of the shot peening on the LCF life, the effectiveness of the shot-peened coating in protecting the disk alloy from oxidation and hot corrosion attack was evaluated. This evaluation was accomplished by exposing coated and shot-peened specimens to 500 h of oxidation followed by 50 h of hot corrosion, both at 760 °C in air. These exposed specimens were then tested in fatigue and compared to similarly treated and exposed uncoated specimens. For all cases, shot peening improved the LCF life of the coated specimens. More specifically, the highest Cr coating showed the best LCF life of the coated specimens after shot peening, as well as after the environmental exposures. Characterization of the coatings after shot peening, oxidation, hot corrosion and LCF testing is presented and discussed.

James A Nesbitt↗

A Dynamic Testing Approach for Particulate Erosion–Corrosion for Gas Turbine Coatings

Particle interactions in gas turbine engines can be multicomponent, complex phenomena leading to the degradation of thermal (TBCs) and environmental barrier coatings (EBCs) meant to protect engine components. Ingestion of particles into the engine can lead to recession of coatings due to particle erosion. Similarly, these same particles can become molten, adhere to coatings and result in thermochemical corrosion of coating materials. Particle erosion testing is often carried out where the particles are injected into a gas stream, accelerated within a nozzle, and impinge on sample. Conversely, most molten particle corrosion testing is often done in static laboratory furnaces, which does not capture the dynamic nature of deposition in application. Nevertheless, these damage mechanisms are often tested separately and no single standard exists to test both erosive and corrosive particle interactions with coating materials under relevant operating conditions for gas turbine engines. Understanding the synergies of particle interactions in engines is crucial in determining operating lifetimes of potential coating materials. Such considerations emphasize the need for realistic approaches in standardizing particle interaction testing in combustion environments. The current study outlines initial efforts at NASA Glenn’s Erosion Burner Rig Facility in improving dynamic erosion/corrosion testing methods by assessing the durability of state-of-the-art (SOA) TBC material 7 wt.% yttria stabilized zirconia (7YSZ) as a function of particle deposition rate, burner temperature, and particle size. Calibration data to determine particle deposition rate will be presented, and mass and optical profilometry measurements were utilized to estimate mass/volume loss versus deposition per increment of particulate used over time. Electron microscopy analyses were then carried out to assess coating damage after testing.

TBC↗

A Dynamic Testing Approach for Particulate Erosion–Corrosion for Gas Turbine Coatings

Particle interactions in gas turbine engines can be multicomponent, complex phenomena leading to the degradation of thermal (TBCs) and environmental barrier coatings (EBCs) meant to protect engine components. Ingestion of particles into the engine can lead to recession of coatings due to particle erosion. Similarly, these same particles can become molten, adhere to coatings and result in thermochemical corrosion of coating materials. Particle erosion testing is often carried out where the particles are injected into a gas stream, accelerated within a nozzle, and impinge on sample. Conversely, most molten particle corrosion testing is often done in static laboratory furnaces, which does not capture the dynamic nature of deposition in application. Nevertheless, these damage mechanisms are often tested separately and no single standard exists to test both erosive and corrosive particle interactions with coating materials under relevant operating conditions for gas turbine engines. Understanding the synergies of particle interactions in engines is crucial in determining operating lifetimes of potential coating materials. Such considerations emphasize the need for realistic approaches in standardizing particle interaction testing in combustion environments. The current study outlines initial efforts at NASA Glenn’s Erosion Burner Rig Facility in improving dynamic erosion/corrosion testing methods by assessing the durability of state-of-the-art (SOA) TBC material 7 wt.% yttria stabilized zirconia (7YSZ) as a function of particle deposition rate, burner temperature, and particle size. Calibration data to determine particle deposition rate will be presented, and mass and optical profilometry measurements were utilized to estimate mass/volume loss versus deposition per increment of particulate used over time. Electron microscopy analyses were then carried out to assess coating damage after testing.

TBC↗

A Dynamic Testing Approach for Particulate Erosion–Corrosion for Gas Turbine Coatings

Particle interactions in gas turbine engines can be multicomponent, complex phenomena leading to the degradation of thermal (TBCs) and environmental barrier coatings (EBCs) meant to protect engine components. Ingestion of particles into the engine can lead to recession of coatings due to particle erosion. Similarly, these same particles can become molten, adhere to coatings and result in thermochemical corrosion of coating materials. Particle erosion testing is often carried out where the particles are injected into a gas stream, accelerated within a nozzle, and impinge on sample. Conversely, most molten particle corrosion testing is often done in static laboratory furnaces, which does not capture the dynamic nature of deposition in application. Nevertheless, these damage mechanisms are often tested separately and no single standard exists to test both erosive and corrosive particle interactions with coating materials under relevant operating conditions for gas turbine engines. Understanding the synergies of particle interactions in engines is crucial in determining operating lifetimes of potential coating materials. Such considerations emphasize the need for realistic approaches in standardizing particle interaction testing in combustion environments. The current study outlines initial efforts at NASA Glenn’s Erosion Burner Rig Facility in improving dynamic erosion/corrosion testing methods by assessing the durability of state-of-the-art (SOA) TBC material 7 wt.% yttria stabilized zirconia (7YSZ) as a function of particle deposition rate, burner temperature, and particle size. Calibration data to determine particle deposition rate will be presented, and mass and optical profilometry measurements were utilized to estimate mass/volume loss versus deposition per increment of particulate used over time. Electron microscopy analyses were then carried out to assess coating damage after testing.

burner rig↗

Tank Bottom Corrosion Induced by Anode-Generated Oxygen

Cathodic protection system using aclose coupled mixed metal oxide (MMO) anode is the corrosion prevention technique for soil-side of the aboveground storage tank (AST) bottoms. MMO anodes generate oxygen at its surfacesdue to water electrolysis at polarized potentials above a threshold; oxygen from the MMO anodes can depolarize the bottoms’polarized potentials. Further, when the tank bottom plate loses contact with the sand pad due to flexing, oxygen can accumulate in the void space and accelerate corrosion. This paper provides information on preventive measures that can be adopted to prevent oxygen concentration corrosion of the AST soil-side bottoms

36 MATERIALS SCIENCE↗

Electrochemical Mitigation of Corrosion in Molten Chloride Salts During CSP Plant Operation

We are designing an electrochemical flow-cell for removal of corrosive impurities from molten chloride salt Gen3 Concentrating Solar Power (CSP) plants during plant operation. Corrosive impurities will inevitably form in molten chloride salts upon exposure to air and moisture. We previously showed that even small amounts of these impurities, especially MgOHCl, will be detrimental in Gen3 CSP plants, necessitating prohibitively expensive containment alloys and frequent replacement of corroded components. Pre-purification of salt with Mg metal at temperatures above 650 degrees C is the current method for removing corrosive impurities from chloride salts before they are introduced to CSP systems. However, this is not a suitable method for impurity removal during plant operation. First, this method will produce MgO particulates which will damage plant components. Second, Mg metal is solid at the low temperature point (500 degrees C), so the purification will not proceed at a fast rate. At the high temperature point, Mg is soluble. In this case, fast purification may proceed, but dissolved metal is likely to precipitate out in cold-temperature point components, causing damage. In contrast, our electrochemically driven method allows fast Mg-based purification to proceed at the low temperature point, without formation of harmful particulates and without the risk of Mg metal precipitation. This novel approach is inspired by electrorefining techniques that are widely employed in industrial metallurgy for removal of impurities from metals. Impurities in the incoming molten salt will be reduced to inert MgO at the cathode, which can be removed by periodically washing the cell with acid. Simultaneously, Mg dissolution at the anode will ensure salt composition is maintained, with no net removal of Mg2+. We have validated this electrochemical approach at lab scale under static conditions with batch rectors. Furthermore, we have performed analytical modeling and technoeconomic analysis to produce a preliminary engineering design for the purification flow cell.

CSP↗

Non-invasive, in situ diagnosis and monitoring of corrosion in high temperature systems

Techniques for non-invasive diagnosis and/or monitoring of corrosion in high temperature systems using specialized sensors that produce multi-mode acoustic signals in situ for accurate determination of wall loss and/or physical property changes for a vessel in contact with a high temperature, highly corrosive substance are disclosed. Sensitivity of a few microns (or about 0.1%) of wall loss, detection of changes in physical properties of vessel contents (e.g., approximately 1%), or both, at temperatures of 500° C., 600° C., or higher may be realized. Corrosion may be identified and/or monitored using time domain, frequency domain, or mixed time domain and frequency domain analysis of signal characteristics, signal delay, or both, for relatively short circumferential acoustic wave propagation (e.g., a few inches), as well as relatively long axial acoustic wave propagation (e.g., tens of feet).

Findikoglu, Alp Tugrul↗

Milestone 1.2.14: Surface Characterization of Irradiated Surrogate Non-Native Corrosion Plumes on Aluminum 6061-T6 Specimens

The United States Department of Energy is seeking to evaluate the feasibility of extended dry storage of aluminum-clad spent nuclear fuel (ASNF) in helium-backfilled cannisters. A significant research effort has been devoted to determining the amount of radiation-induced molecular hydrogen generation from corrosion layers that would be present on the fuel assembly surfaces. However, to date, no evidence of radiation-induced changes in the microstructure of the corroded aluminum surfaces have been reported. This report provides surface characterization, in terms of corrosion layer composition and morphology, for aluminum alloy 6061-T6 “plume” samples subjected to one of three potential ASNF drying techniques—“vacuum only”, “vacuum + 4 hours at 100 oC”, and “vacuum + 4 hours at 220 oC”—and gamma irradiated (= 53 MGy) in the presence of helium gas with ~0% added relative humidity. At these high absorbed gamma doses, for the first time ever, radiation-induced circular defects were found on the sample surface, regardless of the drying regime employed. Additionally, large cracks that penetrated through the corrosion layer to expose bare aluminum metal were observed in irradiated “plume” specimens subjected to drying conditions of “vacuum + 4 hours at 220 oC”. The nature and implications of these defects on the extended dry storage of ASNF is unclear, requiring further study.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Multi-Parameter Optical Fiber Sensing of Humidity, CH4, CO2, and Corrosion

In this work, the previously demonstrated capability of the optical fiber sensor (OFS) for successful monitoring of humidity has been extended to monitor the humidity, CH4, and CO2 with different gas composition based on the strain produced along the single mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases on to the commercially available polyacrylate coated jacketed portion of the fiber resulting a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different humidity conditions, while the unjacketed portion of the fiber was used only for sensing pressure/temperature induced strain. In case of N2 at 800 psig pressure, the observed microstrain was approximately 80, 65, 50 and 35 µε at 100, 75.0, 46.8, and 23.4 RH% respectively. Comparatively, a microstrain of approximately 95 µε was observed with 100% RH CH4 which demonstrates that SMF produces a measurable CH4 response alongside water. Similarly, the observed microstrain with CO2 was approximately 105, 90, 85, 80, and 70 µε at 100, 75.0, 46.8, 23.4, and 0 RH% respectively. Linear regression and principal component analysis of these dataset provided deconvolution of the impact of strain from H2O, CH4, and CO2 enabling good cross sensitivity. Additionally, modified OFS comprising of Fe coated fiber section was employed to monitor corrosion, using Fe as corrosion proxy, under harsh corrosive environment.

Mainali, Badri↗

Determining Drying Conditions to Mitigate Hanford Transfer Line Corrosion

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site.1,2,3 The underground transfer lines are used to transfer the waste between the tanks and other assets at the Hanford tank farm facilities. The transfer lines constructed before 1990 are pipe-in-pipe design with most of the lines having carbon steel carrier pipe and carbon steel encasements. The lines constructed after 1990 have a stainless-steel carrier with a carbon steel encasement. The carrier lines, which are in contact with the waste, provide a critical confinement function, while the encasements provide secondary containment to reduce the risk of a release and contamination to the environment. In 2022, a visual inspection of the annulus between the encasement and the carrier for one of the pre-1990 transfer lines revealed standing liquid in contact with the carrier pipe. Additionally, a significant build-up of corrosion products on the exterior of the carrier pipe and the interior of the encasement pipe was observed. To assess the extent of condition, borescope inspections were performed in the encasement space of additional transfer lines in the facility to provide a baseline. The inspection revealed that of the lines inspected, 29 had either moisture present or evidence that moisture had been present in the past (e.g., waterline corrosion where the pipe had been exposed to standing water). Additional inspections indicated several instances of pitting corrosion on the interior of the encasement and exterior the carrier transfer lines. An image of the carrier pipe with several pits is presented in Figure 1(a) and the profiled image of the transfer line section along with the pit depths are presented Figure 1(b). As seen in the figure, the deepest pit was 73 mils on the pipe section. These lines were designated as “do-not-use” until further compensatory actions are implemented to return the lines to service.

Shukla, Pavan K. [Savannah River National Laborato↗