Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CEOS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Static and dynamic behavior of ultrathin cobalt nanowires embedded in transparent matrix

Two self-assembly of ultrathin Co nanowires (NWs) embedded in a CeO{sub 2} matrix was grown on SrTiO{sub 3}(001) and oxidized Si(001) substrates. A common feature of the two arrays of NWs is the small diameter of the wires, falling in the 4–5 nm range. Combined with their length, the aspect ratio is large enough to ensure large magnetostatic anisotropy with an easy axis along the axis of the nanowires as revealed by magnetometry measurements. The Brillouin light scattering technique has been used to investigate the behavior of the spin waves under a field perpendicular to the NWs axes. The transparency of the matrix ensures the penetration of the probing light inside the sample. Importantly, Brillouin light scattering from the magnetic modes obeys the volume Bragg condition, which is characteristic of the configuration in which the observed modes are propagating along the nanowires and due to their very small diameter are nearly constant across the section. Both series of experimental results are satisfactorily analyzed by means of a single analytical model, based on a mean-field approach, assuming the presence at remanence of two populations of NWs with up and down magnetizations and including the dipolar coupling between the cylinders.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: An X-ray powder diffractometer with a wide scattering-angle range of 72° using asymmetrically positioned one-dimensional detectors

An X-ray powder diffractometer has been developed for a time-resolved measurement without the requirement of a scattering angle (2θ) scan. Six one-dimensional detector modules are asymmetrically arranged in a vertical line at a designed distance of 286.5 mm. A detector module actually covers a diffraction angle of about 12° with an angular resolution of 0.01°. A diffracted intensity pattern is simultaneously recorded in a 2θ angular range from 1.63° to 74.37° in a “one shot” measurement. We tested the performance of the diffractometer with reference CeO{sub 2} powders and demonstrated diffraction measurements from an operating lithium-air battery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and characterization of magnesium doped cerium oxide for the fuel cell application

Cerium oxide has attained much attentions in global nanotechnology market due to valuable application for catalytic, fuel additive, and widely as electrolyte in solid oxide fuel cell. Doped cerium oxide has large oxygen vacancies that allow for greater reactivity and faster ion transport. These properties make cerium oxide suitable material for SOFCs application. Cerium oxide electrolyte requires lower operation temperature which shows improvement in processing and the fabrication technique. In our work, we synthesized magnesium doped cerium oxide by the co-precipitation method. With the magnesium doping catalytic reactivity of CeO{sub 2} was increased. Synthesized nanoparticle were characterized by the XRD and UV absorption techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication and characterization of spark plasma sintered Ce:LuAG ceramic for scintillation application

Rare earth Cerium doped Lutetium Aluminum Garnet (Ce:LuAG) ceramics are widely used as phosphor material in medical imaging and high-energy physics. Due to its technological importance, an attempt has been made to fabricate Ce:LuAG ceramics by using spark plasma sintering (SPS) technique. XRD patterns of SPS sintered Ce:LuAG ceramics reveals a mixed LuAG and CeO{sub 2} (antisite defect) phases. The microstructures of SPS sintered Ce:LuAG ceramics shows limited densification, inappropriate compaction of particles and existence of residual pores, voids between the grain boundaries affects the transparency of Ce:LuAG ceramics. Relative density and hardness of post sintered Ce:LuAG ceramic is also determined. The effect of Ce{sup 3+} doping concentration and sintering temperature on optical luminescence behavior of Ce:LuAG ceramic is presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Defects induced in cerium dioxide single crystals by electron irradiation

In this work, Micro-Raman spectroscopy, X-band electron paramagnetic resonance (EPR) spectroscopy, and UV-visible optical absorption spectroscopy were used to study the damage production in cerium dioxide (CeO 2 ) single crystals by electron irradiation for three energies (1.0, 1.4, and 2.5 MeV). The Raman-active T 2g peak was left unchanged after 2.5-MeV electron irradiation at a high fluence. This shows that no structural modifications occurred for the cubic fluorite structure. UV-visible optical absorption spectra exhibited a characteristic sub band-gap tail for 1.4-MeV and 2.5-MeV energies, but not for 1.0 MeV. Narrow EPR lines were recorded near liquid-helium temperature after 2.5-MeV electron irradiation; whereas no such signal was found for the virgin un-irradiated crystal or after 1.0-MeV irradiation for the same fluence. The angular variation of these lines in the {111} plane revealed a weak g-factor anisotropy assigned to Ce 3+ ions (with the 4f 1 configuration) in a high-symmetry local environment. Finally, it is concluded that Ce 3+ ions may be produced by a reduction resulting from the displacement damage process. However, no evidence of F + or F 0 center or hole center formation due to irradiation was found from the present EPR and optical absorption spectra.

36 MATERIALS SCIENCE↗

Experimental system for studying temperature gradient-driven fracture of oxide nuclear fuel out of reactor

Temperature gradients in ceramic light water reactor (LWR) uranium dioxide (UO 2 ) nuclear fuel pellets generate thermal stresses that cause fractures in the fuel beginning early in the life of fresh fuel. The combination of heating due to fission and forced convective cooling on the exterior of LWR fuel rods generates a temperature profile that is difficult to replicate outside the reactor environment. In the present study, a state-of-the-art experimental set-up using electrical heating to replicate fission heating was built and surrogate fuel materials such as ceria (CeO 2 ) were used to validate the system. Cracking experiments were conducted on these surrogates by inducing reactivity-initiated-accident (RIA) like temperature gradients in the pellets via induction and direct resistance heating. Induction heating was done using copper coils and molybdenum susceptors which heated the surrogates to a threshold temperature that is sufficiently high for the fuel material to conduct current. Thereafter, direct resistance heating was used by a D.C. power supply to introduce volumetric heating to replicate LWR operating conditions analogous to fission heating. The pellets were held against nickel electrodes and mounted on a boron nitride test-stand. All the tests were carried out in a stainless-steel vacuum chamber. Simultaneous real-time dual imaging of the surrogate pellet surface has been implemented using an optical and infrared camera system which will be mounted along axial and perpendicular directions to the pellet surface respectively. A beam-splitter was used to split the incoming radiation from the sample into two halves. While one of the beams is transmitted from the splitter through a bandpass filter to obtain optical images, the other beam is reflected from the splitter to the thermal camera to capture full field temperature gradients of the as fabricated pellet surface during crack initiation and propagation. In the current series of tests, a 2-color pyrometer was used for recording and comparing the surface and centerline temperatures of the surrogate pellets in lieu of the thermal camera. A LabVIEW data acquisition system has been set up for collecting useful data during experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electron energy loss spectroscopy study of ceria sinters and nanoparticles irradiated with swift heavy ions

The electronic energy loss spectra of ceria (CeO 2 ) irradiated with swift heavy ions (27 MeV Xe and 946 MeV Au) in the electronic slowing down regime were measured for bulk sintered samples and nanoparticles by using a double Cs-corrected transmission electron microscope. The low-loss region as well as the core-loss region, including the oxygen K-edge and cerium M 4, 5 white lines, were recorded. No strong lattice disorder was found in the low-loss peaks for both types of samples showing the same bulk oxygen plasmon loss peak at about 15 eV. However, there is a clear evidence of cerium reduction to the trivalent oxidation state after irradiation for the sintered samples as shown by the K-edge shape of oxygen and decrease of the Ce M 4 /M 5 intensity ratio. A similar change of the M 4 /M 5 intensity ratio was observed for the irradiated nanoparticles with respect to the virgin sample owing to the high energy input inside the nanograin. The effect of radiation damage on electron energy loss spectroscopy data is analyzed for both types of samples and irradiation conditions.

Crystallographic defects↗

High-resolution structural characterization and magnetic properties of epitaxial Ce-doped yttrium iron garnet thin films

Thin films of magnetic garnet materials, e.g. yttrium iron garnet (Y 3 Fe 5 O 12 , YIG), are useful for a variety of applications including microwave integrated circuits and spintronics. Moreover, substitution of rare earth ions, such as cerium, is known to enhance the magneto-optic Kerr effect (MOKE) as compared to pure YIG. Thin films of Ce 0.75 Y 2.25 Fe 5 O 12 (Ce:YIG) have been grown using the pulsed laser deposition (PLD) technique and their crystal structure examined using high resolution scanning transmission electron microscopy. Homogeneous substitution of Ce in YIG, without oxidation to form a separate CeO 2 phase, can be realized in a narrow process window with resulting enhancement of the MOKE signal. We investigated the thermally generated signal due to spin Seebeck effect for the optimally doped Ce:YIG films.

36 MATERIALS SCIENCE↗

Automating STEM Aberration Correction via Bayesian Optimization

Multipole aberration correctors have given scanning transmission electron microscopes (STEM) the ability to produce high-quality, atomic-resolution images, enabling STEM to be a key tool in material sciences for characterizing the structure and composition of materials. However, the process of correcting these aberrations typically requires human input and is accomplished using scanned STEM or Ronchigram images at different focii and beam tilts. In this work, we demonstrate an automated on-sample aberration correction system using Bayesian Optimization. We have developed a Python-based server able to communicate with the CEOS DCOR aberration corrector and the Thermo Fischer microscope scripting interface. This server allows us to change aberrations, acquire images and perform basic image analysis.

47 OTHER INSTRUMENTATION↗

Compressive sensing lattice dynamics. II. Efficient phonon calculations and long-range interactions

We apply the compressive sensing lattice dynamics method to calculate phonon dispersion for crystalline solids. While existing methods such as frozen phonon, small displacement, and linear response are routinely applied for phonon calculations, they are considerably more expensive or cumbersome to apply to certain solids, including structures with large unit cells or low symmetry, systems that require more expensive electronic structure treatment, and polar semiconductors/insulators. In the latter case, we propose an approach based on a corrected long-range force constant model with proper treatment of the acoustic sum rule and the symmetric on-site force constant matrix. Here, our approach is demonstrated to be accurate and efficient for these systems through case studies of NaCl, CeO 2 , Y 3 Al 5 O 12 , and La 2 Fe 14 B.

36 MATERIALS SCIENCE↗

Hole antidoping of oxides

In standard doping, adding charge carrier to a compound results in a shift of the Fermi level towards the conduction band for electron doping and towards the valence band for hole doping. In this paper, we discuss the curious case of antidoping, where the direction of band movements in response to doping is reversed. Specifically, $\textit{p}$-type antidoping moves the previously occupied bands to the principal conduction band resulting in an increase of band gap energy and reduction of electronic conductivity. We find that this is a generic behavior for a class of materials: early transition and rare-earth metal (e.g., Ti, Ce) oxides where the sum of composition-weighed formal oxidation states is positive; such compounds tend to form the well-known electron-trapped intermediate bands localized on the reduced cation orbitals. What is less known is that doping by a hole annihilates a single trapped electron on a cation. The latter thus becomes electronically inequivalent with respect to the normal cation in the undoped lattice, thus representing a symmetry-breaking effect. We give specific theoretical predictions for target compounds where hole antidoping might be observed experimentally: Magnéli-like phases (i.e., CeO 2–x and TiO 2–x ) and ternary compounds (i.e., Ba 2 Ti 6 O 13 and Ba 4 Ti 12 O 27 ), and note that this unique behavior opens the possibility of unconventional control of materials conductivity by doping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale probing of resonant photonic modes in dielectric nanoparticles with focused electron beams

We report that understanding the optical responses of nanostructures with high spatial resolution is paramount in photonic engineering. The excitation of resonant optical-frequency geometric modes in oxide nanoparticles is explored using monochromated electron energy-loss spectroscopy in a scanning transmission electron microscope. These geometric or cavity modes are found to produce a progression of resonance peaks within the bandgap regions of the electron energy-loss spectra of CeO 2 , TiO 2 , and MgO nanoparticles. Complementary simulations of the electron probe combined with analytic Mie analysis are performed to interpret the complex spectral features and to understand their underlying physical origins. The factors that influence the energies, shapes, and strengths of these modes are also investigated and their dependence upon nanoparticle size, geometry, refractive index, aggregation, impact parameter, and electron kinetic energy are elucidated. Taken together, this work demonstrates the unique ability of fast electron spectroscopy to determine the photonic density of states in individual and complex assemblies of dielectric nanoparticles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of Ce 4 f hybridization in the origin of magnetism in nanoceria

Nanoscale CeO 2 (nanoceria) is a prototypical system that presents d 0 ferromagnetism. Here, using a combination of x-ray absorption spectroscopy, x-ray magnetic circular dichroism, and modeling, we show that the nanostructure, defects and disorder, and nonstoichiometry create magnetically polarized Ce 4 f and O 2p hybridized states captured by the vacancy orbitals ( V orb ) that are vital to ferromagnetism. Further, we demonstrate that foreign ions (Fe and Co) enhance the moment at Ce 4 f sites while the number of V orb is unchanged, pointing clearly to the mechanism of orbital hybridization being the key missing ingredient to understanding the unexpected ferromagnetism in many nanoscale dilute magnetic oxides and semiconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Specimen-displacement correction for powder X-ray diffraction in Debye–Scherrer geometry with a flat area detector

The effect of small changes in the specimen-to-detector distance on the unit-cell parameters is examined for synchrotron powder diffraction in Debye–Scherrer (transmission) geometry with a flat area detector. An analytical correction equation is proposed to fix the shift in 2θ values due to specimen capillary displacement. This equation does not require the use of an internal reference material, is applied during the Rietveld refinement step, and is analogous to the specimen-displacement correction equations for Bragg–Brentano and curved-detector Debye–Scherrer geometry experiments, but has a different functional form. The 2θ correction equation is compared with another specimen-displacement correction based on the use of an internal reference material in which new integration and calibration parameters of area-detector images are determined. Example data sets showing the effect of a 3.3 mm specimen displacement on the unit-cell parameters for 25°C CeO 2 , including both types of displacement correction, are described. These experiments were performed at powder X-ray diffraction beamlines at the National Synchrotron Light Source II at Brookhaven National Laboratory and the Advanced Photon Source at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

Synthesis and structure of high-purity BaCe 0.25 Mn 0.75 O 3 : an improved material for thermochemical water splitting

Solar thermochemical hydrogen production (STCH) via redox-active metal oxides is an approach for direct solar-driven hydrogen generation typically using a high-temperature redox cycle involving refractory oxides and steam. Typical cycles involve high-temperature reduction of oxides to form oxygen vacancies, followed by lower temperature reaction between oxygen vacancies and steam where the oxide is re-oxidized and the steam is reduced to hydrogen. Only a few materials have demonstrated reversible cycling under the typically harsh STCH conditions (e.g. 1500°C reduction, 900°C re-oxidation) and critical questions remain on the true reversibility of non-stoichiometric multi-cation oxide systems, significantly hampered by the lack of single-phase samples for these material systems. To date, most STCH processes have relied on CeO 2 as a benchmark active material, but more recently, the 12R phase of BaCe 0.25 Mn 0.75 O 3 (BCM) has demonstrated greater hydrogen-generation potential at lower peak temperatures. However, previous reports of 12R-BCM have included large fractions, > 10 wt%, of secondary phases, which complicate analysis of the stability and performance. A comprehensive understanding of the redox mechanism and reversibility of the process in BCM can only be achieved with nearly single-phase samples which, to date, have been difficult to produce. Here two approaches to BCM synthesis are reported: solid state and sol–gel-based routes. It is demonstrated that both routes can be tuned to produce the 12R structure with > 97 wt% yield when annealed ≥1450°C. Herein synchrotron-based diffraction measurements of rhombohedral 12R-BCM enabled characterization of the anisotropy between thermal expansion along the c-axis and within the ab plane. The impact of high-temperature redox cycling on the stability and phase fraction of the 12R-BCM polytype was also investigated. Our results offer two viable routes for synthesis of high-purity 12R-BCM critically needed for evaluating the efficacy of BCM as a STCH material and validate its ability to split water at lower temperatures over extended numbers of redox cycles.

08 HYDROGEN↗

Influence of partial charge on the material removal rate during chemical polishing

A partial charge-based chemical polishing model has been developed, which can serve as metric for describing the relative polishing material removal rate for different combinations of slurries and workpieces. A series of controlled polishing experiments utilizing a variety of colloidal polishing slurries (SiO 2 , CeO 2 , ZrO 2 , MgO, Sb 2 O 5 ) and optical materials [single crystals of Al 2 O 3 (sapphire), SiC, Y 3 Al 5 O 12 (YAG), CaF 2 , and LiB 3 O 5 (LBO); a SiO 2 -Al 2 O 3 -P 2 O 5 -Li 2 O glass ceramic (Zerodur); and glasses of SiO 2 :TiO 2 (ULE), SiO 2 (fused silica), and P 2 O 5 -Al 2 O 3 -K 2 O-BaO (Phosphate)] was performed and its material removal rate was measured. As previously proposed by Cook (J Non-Cryst Solids. 1990;120:152), for many polishing systems, the removal rate is governed by a series of chemical reactions which include the formation of a surface hydroxide, followed by condensation of that hydroxyl moiety with the polishing particle, and a subsequent hydrolysis reaction. The rate of condensation can often be the rate limiting step, thus it can determine the polishing material removal rate. By largely keeping the numerous other factors that influence material removal rate fixed (such as due to particle size distributions, interface interactions, pad topography, kinematics, and applied pressure), the material removal rate is shown to scale exponentially with the partial charge difference (δ wp-s ) between the workpiece and polishing slurry particle for many of the slurry-workpiece combinations indicating that condensation rate is the rate limiting step. The partial charge (δ) describes the equilibrium distribution of electron density between chemically bonded atoms and is related to the electronegativity of the atoms chemically bonded to one another. This partial charge model also explains the age-old experimental finding of why cerium oxide is the most effective polishing slurry for chemical removal of many workpieces. Finally, some of the slurry-workpiece combinations that did not follow the partial charge dependence offer insight to other removal mechanisms or rate limiting reaction pathways.

36 MATERIALS SCIENCE↗

Assessment of Bulk Oxygen Capacity and Transient Redox Behavior of Foamed Lanthanum Strontium Manganese Perovskites

Synthesis of solar thermochemical hydrogen (STCH) production redox materials with engineered structures, for example, replica foams, can enable efficient heat and mass transport and are critical for scaled-up systems. Prior work has motivated the use of lanthanum strontium manganese (LSM)-type perovskites as foamed STCH materials, but the effect of their morphology on bulk and kinetic behavior has not been reported. In this work, replica and direct foamed samples of La 0.65 Sr 0.35 MnO 3-δ (LSM35) were fabricated and compared to synthesized powders and dense monoliths, and similarly synthesized CeO 2-δ (ceria) foams, regarding their specific reaction rates and bulk oxygen capacity/H 2 yields. Changes in oxygen capacity (Δδ) and reaction rates were measured between 1200 °C and 1400 °C by using fixed ratios of steam and hydrogen during both reduction and oxidation steps, allowing for analysis under practical high conversion conditions. Results suggest bulk behavior and reaction rates of the foamed LSM materials are comparable to their powder analogues. Differences in reaction rates were observed only when replica foamed samples were subjected to rapid laser heating (emulating conditions expected in solar furnaces), which is expected but has not been demonstrated at such a small scale. Here, foamed samples were further subjected to 50 redox cycles at 1400 °C to evaluate their stability. Results show no statistically significant decrease in hydrogen production for any of the foamed samples, but the direct foamed samples became brittle with time. Together, these results demonstrate the viability of replica foamed LSM perovskites for integration in scaled-up STCH systems.

08 HYDROGEN↗

WE-A-16A-01: International Medical Physics Symposium: Increasing Access to Medical Physics Education/Training and Research Excellence

In response to a world in which cancer is a growing global health challenge, there is now a greater need for US Medical Physicists and other Radiation Oncology professionals across institutions to work together and be more globally engaged in the fight against cancer. There are currently many opportunities for Medical Physicists to contribute to alleviating this pressing need, especially in helping enhance access to Medical Physics Education/training and Research Excellence across international boundaries, particularly for low and middle-income countries (LMIC), which suffer from a drastic shortage of accessible knowledge and quality training programs in radiotherapy. Many Medical Physicists are not aware of the range of opportunities that even with small effort could have a high impact. Faculty at the two CAMPEP-accredited Medical Physics Programs in New England: the University of Massachusetts Lowell and Harvard Medical School have developed a growing alliance to increase Access to Medical Physics Education/training and Research Excellence (AMPERE), and facilitate greater active involvement of U.S. Medical Physicists in helping the global fight against cancer and cancer disparities. In this symposium, AMPERE Alliance members and partners from Europe and Africa will present and discuss the growing global cancer challenge, the dearth of knowledge, research, and other barriers to providing life-saving radiotherapy in LMIC, mechanisms for meeting these challenges, the different opportunities for participation by Medical Physicists, including students and residents, and how participation can be facilitated to increase AMPERE for global health. Learning Objectives: To learn about the growing global cancer challenge, areas of greatest need and limitations to accessing knowledge and quality radiotherapy training programs, especially in LMIC; To learn about the range of opportunities for Medical Physicists, including students and residents, to work together in global health to help increase AMPERE and alleviate the growing global burden of cancer; To present and discuss a new model for harmonizing Medical Physics Training across countries and how this model (UMass and Heidelberg) could be extended to LMIC in collaboration with the IAEA; To highlight a new platform and program for facilitating contributions by Medical Physicists to increase AMPERE towards the elimination of global cancer disparities. Challenges in Cancer Control in Africa Twalib A. Ngoma, MD, Professor, Executive Director, Ocean Road Cancer Institute, Dar Es Salaam, Tanzania Cancer care in Africa is beset by lack of attention, political will, cancer registries, cancer plans, human resources, financial resources and treatment facilities.. As a result of this, cancer patients in Africa are far more likely to die of their disease than those in developed countries. According to data from the WHO 750,000 new cancer cases occur in Africa every year and this number is predicted to rise by 70% by 2020. To make matters worse, an estimated 75% of cancer patients in Africa have advanced or incurable cancers at diagnosis making palliative care the most realistic approach to their management. Furthermore, Cancer prevention is nearly nonexistent, cancer detection is rare and treatment usually comes too late and is inefficient. The overall mortality-to-incidence ratio for men with cancer in the Africa is 0.75 compared with 0.54 in the developed world while the ratios for women in Africa, is 0.65 compared with 0.45 for women in the developed world. There is also limited access to radiotherapy. According to the International Atomic Energy Agency (IAEA), whilst developed countries usually have one radiotherapy machine per 250,000 people, most African nations have only one machine per ten million people. The above numbers are alarming and speak for themselves. The only solution to improve this alarming situation is to address the major challenges which African countries face in provision of cancer services which include but not limited to lack of cancer registries, lack of funding, lack of human resources, lack of radiotherapy machines, lack of cancer drugs and lack of accessible and affordable cancer screening, early diagnosis, treatment or palliative care services. Since there are considerable differences among African countries, in my presentation I will share with the audience how we address cancer control challenges in Tanzania in general and specifically in radiation oncology. The African continent cancer plan 2013 2017 Folakemi Odedina, PhD, Professor and Director of Health Disparities, UF Health Cancer Center, University of Florida The burden of cancer is rising in Africa, in addition to current heavy burden of communicable, and other non-cancer related non—communicable diseases. Conquering cancer in Africa will require a comprehensive collaborative approach with cancer clinicians, scientists, patients, advocates, policy makers and community leaders working hand-in-hand at the local, state, national, and continent levels with the primary mission: To reduce the number of deaths from cancer and improve the quality of life of cancer patients, survivors and caregivers. Unfortunately, less than 40% of African countries have a credible cancer control policy and program. The African Organization for Research and Training in Cancer (AORTIC) decided to create an African Cancer Plan to provide cost-effective strategies that can be employed throughout the continent to fight cancer. Based on the African proverb that “It takes a village to raise a child”, the Cancer Plan provides specific strategies that can be used by individuals, employers, organizations and policy-makers to fight cancer. In addition, we have provided overarching strategies to address cancer in Africa and targeted 5-year plan for prostate, breast, cervix, lung and liver cancers. In developing this Cancer Plan, our primary goal is to decrease cancer incidence and mortality in Africa. This goal can only be achieved by stakeholders and dedicated individuals to lead and implement the strategies outlined in this plan. If you are interested in partnering with AORTIC to reduce the burden of cancer in Africa, please send an email to info@aortic-africa.org. Synergies in research and clinical care through international collaboration Thomas Bortfeld and David Gierga, Massachusetts General Hospital, Harvard Medical School, MA Medical Physics relies on high technology that is not distributed equally. The whole spectrum of Medical Physics technologies is not available at every hospital or research institute, and not even in every high income country. One example is heavy ion therapy equipment which is currently only available in Japan, Germany and Italy. There is also a large global variation in terms of research infrastructure and focus. A student of Medical physics cannot gain broad experience, certainly not hands-on experience, by staying at one place only. While it is debatable what a good trade-off between breadth and depth in Medical Physics education is, it is generally agreed upon that some breadth is necessary. Researchers in Medical Physics have to cross borders if they need specific technologies for their projects. Therefore it is self-evident that international programs in Medical Physics education and research make sense. Yet, very few programs of this type exist. In this presentation we will report on our own experience of pursuing an international career in Medical Physics, with international student programs, and with the international exchange of researchers. We will present new or planned opportunities such as the medical beamline at CERN in Geneva. We will also report on the synergies in clinical care through international collaborations between partners in high and low income countries. One example is the partnership of the MGH/Harvard Medical School community with the oncology community and government of Botswana to form the BOTSOGO (BOTSwana Oncology Global Outreach) initiative. This collaborative effort in oncology care was spurred by existing relationships in HIV/AIDS research and care delivery developed within the Botswana-Harvard AIDS Institute Partnership (BHP). The initial efforts of the BOTSOGO initiative have been organized as follows: 1) on-site visits to share expertise in clinical cancer care for capacity building purposes (e.g. cervical brachytherapy), 2) developing a forum for multi-disciplinary case discussions and education and 3) relationship building with local stakeholders for long-term sustainability and growth. An international system for the certification of medical physicists Raymond K. Wu, Chairman, IOMP Professional Relations Committee; Chairman, AAPM Exchange Scientist Program Subcommittee An international system for the certification of medical physicists is an important issue. The International Organization for Medical Physicists (IOMP) has in collaboration with a number of member countries established the International Medical Physics Certification Board (IMPCB) to address this issue, and to provide a mechanism to mark the milestone for the professional development of clinical medical physicists. Raymond Wu, PhD, is the CEO of IMPCB and the Chairman of the IOMP Professional Relations Committee. He is the invited speaker recommended by IOMP to give a talk on this important subject. He will give the latest update of the work of IMPCB, its near term goals, and pathways to the goals. He will also discuss the importance of such an International System of certification in the training/education of next generation Medical Physicists, including those in low and middle income countries (LMIC) where such training is crucial in the fight against cancer. Learning Objectives: Understand the certification program as described in the IOMP Policy Statements. Understand the plan of the IMPCB to establish the accreditation process of national certification programs. Understand the goals of this international collaborative effort and the potential impacts to the quality of clinical medical physics practice. Medical Physics Education Across Continents: The UMass Lowell and Heidelberg University Joint Coordination Effort Erno Sajo, Director of Medical Physics, University of Massachusetts at Lowell Medical Physics education has unique flavors across institutions within the US and shows significant differences across continents. In the latter, even the definition of Medical Physics may differ. Not only is there a difference in topical coverage, but often what is considered a cohesive topic in one institution, and taught as a single course, is fragmented among several other courses in the other institution due to a different philosophy. Because of the regulatory and certification requirements, these differences impact the mobility of medical physicists across continents. As a result, physicists who wish to practice in the US or Canada but have completed their education elsewhere often find that they have to take remedial courses or even obtain a new degree in Medical Physics despite the fact that they already have one. Outreach to developing countries, therefore, is even more difficult. The University of Massachusetts Lowell and Heidelberg University recently completed a joint coordination effort, in which they identified topics that are common versus complementary in their medical physics curricula. A student exchange program was developed that permits students to take any of the common topics at the other institution while taking complementary courses as electives, which count towards their degree requirements at their home institution. Thesis research is also mutually accepted. When properly documented, in this way CAMPEP recommendations can be met across the institutions. Therefore, students participating in this program satisfy both the American Board of Radiology (ABR) requirements and the European regulatory requirements. The framework on which this collaboration rests and the cross-comparison methods developed therein may be implemented in other exchange programs and thus a similar approach can be adopted in outreach programs with developing countries. IAEA PACT Program and opportunities for support and collaboration Susan Morgan, Program Coordinator, International Atomic Energy Agency, Vienna, Austria In response to the developing world's cancer crisis, the International Atomic Energy Agency (IAEA) established the Program of Action for Cancer Therapy (PACT) in 2004 to fully realize the public health impact obtained through global partnerships in cancer control and technology transfer in radiation medicine. PACT's vision strives for global partnerships to confront the cancer crisis in developing countries, notably with our sister United Nations agency, the World Health Organization (WHO), and our Joint Programme on Cancer Control established in 2009. The IAEA, through PACT, the WHO, the International Agency for Research on Cancer (IARC) and other cancer-related organizations work together to make a coordinated global response in supporting low and middle income (LMI) IAEA Member States in the implementation of comprehensive national cancer control programmes. PACT's goals are: To build global partnerships of cancer-related organizations committed to addressing the challenge of cancer in LMI Member States in all its aspects; To mobilize resources from charitable trusts, foundations, and others in public and private sectors sources to assist LMI Member States to develop and implement their radiation medicine capacities within a national cancer control programme (NCCP); and, To ensure the effective and sustainable transfer of radiation medicine technologies or knowledge to all LMI Member States where unmet needs exist. PACT work focuses on: imPACT: Assessing Cancer Burden PMDS: Developing Global Partnerships VUCCnet: Promoting Cancer Control Training AGaRT: Making Radiotherapy Accessible Facilitating increased participation and professional development of Medical Physicists and other Radiation Oncology professionals in global health Wilfred Ngwa, Harvard Medical School, University of Massachusetts Lowell, MA The 2014 World Health Organization (WHO) Cancer report highlights an alarming increase in the global burden of cancer. It also highlights what it terms “the cancer divide”, or disparities, evinced by a substantially higher cancer burden in low and middle income countries (LMIC) in Asia, Central/South America and Africa. The WHO even predicts a potential African cancer epidemic by 2020 if significant progress is not made in global cancer control efforts. Evidence that collaborative global health approaches have led to major progress in controlling infectious diseases including in LMIC suggests that similar approaches will be useful for non-communicable diseases like cancer. In consonance with this, leaders in cancer policy from the USA and 14 economically diverse countries recently concluded that successful campaigns to control cancers with existing methods and to improve current strategies will increasingly depend onconcerted multinational collaborations (Sci Transl Med 5, p. 175, 2013). Hence there is growing urgency for increasing collaborative global cancer Care Research and Education (CaRE), as well as support for greater effectiveness of already existing initiatives involving partners from different nations, diverse economic and cultural backgrounds. The good news is that there is a growing awareness of the importance of global health and growing interest including amongst Medical Physicists and other Radiation oncology (RadOnc) professionals to participate in global health. However, many are unaware of currently existing opportunities for participation that even with small effort could have a high impact. Over 50% of cancer patients in the developed world depend on RadOnc professionals for their treatment, and hence participation of RadOnc professionals in global health efforts in the global fight against cancer is crucial. It is also important that the next generation of RadOnc professionals (students, and residents) be trained with a global perspective, to be global health leaders in cancer CaRE. This presentation will highlight a novel platform for enhancing participation and professional development of Medical Physicists and other RadOnc professionals in global health. Ways in which this platform can facilitate contributions by Medical Physicists and other RadOnc Professionals, students and residents in global health towards the elimination of global cancer disparities will be discussed. This will be followed by a panel discussion by some of the pioneers/leaders in collaborative global cancer CaRE on the growing cancer burden, challenges and opportunities for greater active involvement and professional development.

60 APPLIED LIFE SCIENCES↗