Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Co-culture of 3D tumor spheroids with fibroblasts as a model for epithelial–mesenchymal transition in vitro

Epithelial–mesenchymal transition (EMT) acts as a facilitator of metastatic dissemination in the invasive margin of malignant tumors where active tumor–stromal crosstalks take place. Co-cultures of cancer cells with cancer-associated fibroblasts (CAFs) are often used as in vitro models of EMT. We established a tumor–fibroblast proximity co-culture using HT-29 tumor spheroids (TSs) with CCD-18co fibroblasts. When co-cultured with TSs, CCD-18co appeared activated, and proliferative activity as well as cell migration increased. Expression of fibronectin increased whereas laminin and type I collagen decreased in TSs co-cultured with fibroblasts compared to TSs alone, closely resembling the margin of in vivo xenograft tissue. Active TGFβ1 in culture media significantly increased in TS co-cultures but not in 2D co-cultures of cancer cells–fibroblasts, indicating that 3D context-associated factors from TSs may be crucial to crosstalks between cancer cells and fibroblasts. We also observed in TSs co-cultured with fibroblasts increased expression of α-SMA, EGFR and CTGF; reduced expression of membranous β-catenin and E-cadherin, together suggesting an EMT-like changes similar to a marginal region of xenograft tissue in vivo. Overall, our in vitro TS–fibroblast proximity co-culture mimics the EMT-state of the invasive margin of in vivo tumors in early metastasis. - Highlights: • An adjacent co-culture of tumor spheroids and fibroblasts is presented as EMT model. • Activation of fibroblasts and increased cell migration were shown in co-culture. • Expression of EMT-related factors in co-culture was similar to that in tumor tissue. • Crosstalk between spheroids and fibroblasts was demonstrated by secretome analysis.

60 APPLIED LIFE SCIENCES↗

mmu-miR-1963 negatively regulates the ameloblast differentiation of LS8 cell line by directly targeting Smoc2 3’UTR

Highlights: • mmu-miR-1963 could downregulate the expression of Smoc2 by binding to its 3’UTR. • Smoc2 could promote the amelogenic differentiation of LS8. • mmu-miR-1963 inhibits the ameloblast differentiation of LS8 via Smoc2. RUNX2 is a key regulator of osteogenic differentiation and odontoblastic differentiation. RUNX2 mutations could cause Cleidocranial dysplasia (CCD; OMIM119600), which is featured by abnormal development of bone and teeth. By using microRNA array, we identified a large number of microRNAs that showed different expression between wild-type Runx2 group and mutant groups. The aim of this study is to find out the effect of mmu-miR-1963, which was downregulated in all mutant Runx2 groups, on the ameloblast differentiation of LS8 cells. qPCR and Western Blot results showed the suppressive effect of mmu-miR-1963 on ameloblast differentiation of LS8 cell line. We further confirmed Smoc2 as one direct target of mmu-miR-1963. For the first time, we showed that mmu-miR-1963 could regulate the ameloblast differentiation of LS8 by targeting Smoc2. This study suggests the suppressive role of mmu-miR-1963 on ameloblast differentiation of LS8 via directly targeting the 3’UTR of Smoc2. We also demonstrated that Smoc2 itself could promote the ameloblast differentiation of LS8 for the first time. Our results indicate a novel explanation to the enamel hypoplasia phenotype in part of CCD patients.

60 APPLIED LIFE SCIENCES↗

Improving Image Quality and Reducing Drift Problems via Automated Data Acquisition and Averaging in Cs-corrected TEM

Image acquisition with a CCD camera is a single-press-button activity: after selecting exposure time and adjusting illumination, a button is pressed and the acquired image is perceived as the final, unmodified proof of what was seen in the microscope. Thus it is generally assumed that the image processing steps of e.g., 'dark-current correction' and 'gain normalization' do not alter the information content of the image, but rather eliminate unwanted artifacts. Image quality therefore is, among a long list of other parameters, defined by the dynamic range of the CCD camera as well as the maximum allowable exposure time depending on sample drift (ignoring sample damage). Despite the fact that most microscopists are satisfied with present, standard image quality we found that it is a relatively easy to improve on existing routines in at least two aspects: (1) Suppression of lateral image drift during acquisition by using significantly shorter exposure times with a plurality of exposures (3D-data set); and (2) Improvement in the Signal/Noise ratio by averaging over a given data set by exceeding the dynamic range of the camera.

99 GENERAL AND MISCELLANEOUS↗

Coupled Cluster Theory on Graphics Processing Units I. The Coupled Cluster Doubles Method

The coupled cluster (CC) ansatz is generally recognized as providing one of the best wave function-based descriptions of electronic correlation in small- and medium-sized molecules. The fact that the CC equations with double excitations (CCD) may be expressed as a handful of dense matrix-matrix multiplications makes it an ideal method to be ported to graphics processing units (GPUs). Here we present our implementation of the spin-free CCD equations in which the entire iterative procedure is evaluated on the GPU. The GPU-accelerated algorithm readily achieves a factor of 4-5 speedup relative to the multithreaded CPU algorithm on same-generation hardware. The GPU-accelerated algorithm is approximately 8-12 times faster than Molpro, 17-22 times faster than NWChem, and 21-29 times faster than GAMESS for each CC iteration. Single-precision GPU-accelerated computations are also performed, leading to an additional doubling of performance. Single-precision errors in the energy are typically on the order of 10 -6 hartrees and can be improved by about an order of magnitude by performing one additional iteration in double precision.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three- and four-body nonadditivities in nucleic acid tetramers: a CCSD(T) study

Three- and four-body nonadditivities in the uracil tetramer (in DNA-like geometry) and the GC step (in crystal geometry) were investigated at various levels of the wave-function theory: HF, MP2, MP3, L-CCD, CCSD and CCSD(T). All of the calculations were performed using the 6-31G**(0.25,0.15) basis set, whereas the HF, MP2 and the MP3 nonadditivities were, for the sake of comparison, also determined with the much larger aug-cc-pVDZ basis set. The HF and MP2 levels do not provide reliable values for many-body terms, making it necessary to go beyond the MP2 level. The benchmark CCSD(T) three- and four-body nonadditivities are reasonably well reproduced at the MP3 level, and almost quantitative agreement is obtained (fortuitously) either on the L-CCD level or as an average of the MP3 and the CCSD results. Reliable values of many-body terms (especially their higher-order correlation contributions) are obtained already when the rather small 6-31G**(0.25,0.15) basis set is used. The four-body term is much smaller when compared to the three-body terms, but it is definitely not negligible, e.g. in the case of the GC step it represents about 16% of all of the three- and four-body terms. While investigating the geometry dependence of many-body terms for the GG step at the MP3/6-31G**(0.25,0.15) level, we found that it is necessary to include at least three-body terms in the determination of optimal geometry parameters.

59 BASIC BIOLOGICAL SCIENCES↗

Anisotropic Decomposition of Energetic Materials

Using a white x-ray synchrotron beam, we have dynamically studied radiation-induced decomposition in single crystalline PETN and TATB. By monitoring the integrated intensity of selected diffraction spots via a CCD x-ray camera as a function of time, we have found that the decomposition rate varies dramatically depending upon the orientation of the crystalline axes relative to polarized x-ray beam and for differing diffracting conditions (spots) within the same crystalline orientation. We suggest that this effect is due to Compton scattering of the polarized x-rays with electron clouds that is dependent upon their relative orientation. This novel effect may yield valuable insight regarding anisotropic detonation sensitivity in energetic materials such as PETN.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Insect Wing Displacement Measurement Using Digital Holography

Insects in flight have been studied with optical non destructive techniques with the purpose of using meaningful results in aerodynamics. With the availability of high resolution and large dynamic range CCD sensors the so called interferometric digital holographic technique was used to measure the surface displacement of in flight insect wings, such as butterflies. The wings were illuminated with a continuous wave Verdi laser at 532 nm, and observed with a CCD Pixelfly camera that acquire images at a rate of 11.5 frames per second at a resolution of 1392x1024 pixels and 12 Bit dynamic range. At this frame rate digital holograms of the wings were captured and processed in the usual manner, namely, each individual hologram is Fourier processed in order to find the amplitude and phase corresponding to the digital hologram. The wings displacement is obtained when subtraction between two digital holograms is performed for two different wings position, a feature applied to all consecutive frames recorded. The result of subtracting is seen as a wrapped phase fringe pattern directly related to the wing displacement. The experimental data for different butterfly flying conditions and exposure times are shown as wire mesh plots in a movie of the wings displacement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high-resolution coherent transition radiation diagnostic for laser-produced electron transport studies (invited)

High-resolution images of the rear-surface optical emission from high-intensity (I{approx}10{sup 19} W/cm{sup 2}) laser illuminated metal foils have been recorded using coherent transition radiation (CTR). CTR is generated as relativistic electrons, generated in high-intensity laser-plasma interactions, exit the target's rear surface and move into vacuum. A transition radiation diagnostic (TRD) records time-integrated images in a 24 nm bandwidth window around {lambda}=529 nm. The optical transmission at {lambda}=1053 nm, the laser wavelength, is 15 orders of magnitude lower than the transmission at the wavelength of interest, {lambda}=527 nm. The detector is a scientific grade charge-coupled device (CCD) camera that operates with a signal-to-noise ratio of 10{sup 3} and has a dynamic range of 10{sup 4}. The TRD has demonstrated a spatial resolution of 1.4 {mu}m over a 1 mm field of view, limited only by the CCD pixel size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Invited Article: Deep Impact instrument calibration

Calibration of NASA's Deep Impact spacecraft instruments allows reliable scientific interpretation of the images and spectra returned from comet Tempel 1. Calibrations of the four onboard remote sensing imaging instruments have been performed in the areas of geometric calibration, spatial resolution, spectral resolution, and radiometric response. Error sources such as noise (random, coherent, encoding, data compression), detector readout artifacts, scattered light, and radiation interactions have been quantified. The point spread functions (PSFs) of the medium resolution instrument and its twin impactor targeting sensor are near the theoretical minimum [{approx}1.7 pixels full width at half maximum (FWHM)]. However, the high resolution instrument camera was found to be out of focus with a PSF FWHM of {approx}9 pixels. The charge coupled device (CCD) read noise is {approx}1 DN. Electrical cross-talk between the CCD detector quadrants is correctable to <2 DN. The IR spectrometer response nonlinearity is correctable to {approx}1%. Spectrometer read noise is {approx}2 DN. The variation in zero-exposure signal level with time and spectrometer temperature is not fully characterized; currently corrections are good to {approx}10 DN at best. Wavelength mapping onto the detector is known within 1 pixel; spectral lines have a FWHM of {approx}2 pixels. About 1% of the IR detector pixels behave badly and remain uncalibrated. The spectrometer exhibits a faint ghost image from reflection off a beamsplitter. Instrument absolute radiometric calibration accuracies were determined generally to <10% using star imaging. Flat-field calibration reduces pixel-to-pixel response differences to {approx}0.5% for the cameras and <2% for the spectrometer. A standard calibration image processing pipeline is used to produce archival image files for analysis by researchers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The use and characterization of a backilluminated charge-coupled device in investigations of pulsed x-ray and radiation sources

Examinations of bremsstrahlung and energetic electron beams from a novel laser plasma source motivate and assist characterization of a backthinned, backilluminated direct detection x-ray charge-coupled device (CCD), a topology that is uncommon in hard x-ray work. Behavior toward pseudomonochromatic ({sup 55}Fe) and multichromatic ({sup 241}Am) sources is briefly reviewed under optimized noise conditions. Results collectively establish the previously unknown functional depth structure. Several modes of usage are illustrated in {approx}4-20 keV x-ray laser plasma source investigations, where the significance of the characterization is briefly discussed. The spectral redistribution associated with this CCD topology is unfavorable, yet appropriate analysis ensures that sufficient spectral information remains for quantitative determination of broadband x-ray flux and spectra in essentially single laser shot measurements. The energy dependence of nascent electron cloud radii in silicon is determined using broadband x-rays from the laser plasma source, turning the narrow depletion depth to advantage. Finally, the characterization is used to quantify recent x-ray spectral explorations of the water jet laser plasma source operating under aspirator vacuum. These results will have key value for establishment of laboratory based ultrafast extended x-ray absorption fine structure experiments using microbolometric detectors.

43 PARTICLE ACCELERATORS↗

Extended fast-ion D-alpha diagnostic on DIII-D

A fast-ion deuterium-alpha (FIDA) diagnostic, first commissioned on DIII-D in 2005, relies on Doppler-shifted light from charge-exchange between beam neutrals and energetic ions. The second generation (2G) system was installed on DIII-D in 2009. Its most obvious improvement is the spatial coverage with 11 active in-beam and three passive off-beam views; the latter allows for simultaneous monitoring of the background signal. Providing extended coverage in fast-ion velocity space, the new views possess a more tangential component with respect to the toroidal field compared to their first generation counterparts. Each viewing chord consists of a bundle of three 1.5 mm core fibers to maximize light gathering. For greater throughput, fast f/1.8 optical components are used throughout. The signal is transmitted via fiber optics to a patch panel, so the user is able to choose the detector. FIDA was originally installed with a spectrometer and charge-coupled device (CCD) camera to monitor the full D{sub {alpha}} spectrum for two spatial views. 2G adds another spectrometer and CCD that monitor the blue-shifted wing for six spatial views at 1 kHz. In addition, a photomultiplier tube and fast digitizer provide wavelength-integrated signals at 1 MHz for eight spatial views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential Phase-Contrast Scanning X-Ray Microscope For Observation Of Low-Z element Specimen

Differential phase-contrast scanning x-ray microscope/microtomography have been developed. A fast readout charge-coupled device (CCD) camera coupled with a visible-light conversion unit is used as a detector to record the transmitted intensity distribution of far-field image for every pixel in a scan. Simultaneous absorption and phase-contrast images are given from a single scan by image-processing of the CCD frames. The system is constructed at BL20XU of SPring-8, and its feasibility is demonstrated at the photon energy of 8 keV. A tantalum test chart is observed and its finest structure of 140 nm pitch pattern is clearly observed. Measured phase sensitivity is approximately {lambda}/270. Some low-Z element specimens are observed and obtained phase contrast image shows much higher sensitivity than that of absorption contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Firmware lower-level discrimination and compression applied to streaming x-ray photon correlation spectroscopy area-detector data

We present a data acquisition system to perform on-the-fly background subtraction and lower-level discrimination compression of streaming x-ray photon correlation spectroscopy data from a fast charge-coupled device (CCD) area detector. The system is built using a commercial frame grabber with an on-board field-programmable gate array. The system is capable of continuously processing at least 60 CCD frames per second each consisting of 1024 x 1024 16-bit pixels with < or approx. 15 000 photon hits per frame at a maximum compression factor of {approx_equal}95%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of two-grating spectrometer for the charge exchange spectroscopy system on KSTAR

The charge exchange spectroscopy (CES) system on Korea Superconducting Tokamak Advanced Research (KSTAR) was installed last year and had been applied to measure the C VI ion temperature and rotation velocity profiles. The ion temperature and rotation velocity profiles had been estimated from the C VI 5290.5 A (n = 8-7) charge-exchange spectrum signal measured by a Czerny-Turner type spectrometer and a thinned back-illuminated charge coupled device (CCD) camera. However, the Czerny-Turner type spectrometer used for the KSTAR CES system showed so low signal to noise ratio for KSTAR plasmas in the 2010 experimental campaign that the time resolution of the CES system had been limited to 100 ms due to the increased exposure time of the attached CCD camera. Then, new two-grating spectrometer had been developed in order to improve the time resolution of the CES system. The spectrometer consists of two gratings (1200 g/mm and 1800 g/mm each) with additive configuration, concave mirrors (f = 50 cm), and a cylindrical lens (f = 50 cm). The time resolution of the CES system increases by a factor of 2-4 with the two-grating spectrometer. The C VI ion temperature and rotation velocity profiles obtained by the two-grating spectrometer are compared to those by Czerny-Turner type spectrometer in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact multichannel spectrometer for Thomson scattering

The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T{sub e} < 100 eV are achieved by a 2971 l/mm VPH grating and measurements T{sub e} > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated ({approx}2 ns) ICCD camera for detection. A Gen III image intensifier provides {approx}45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring electron-positron annihilation radiation from laser plasma interactions

We investigated various diagnostic techniques to measure the 511 keV annihilation radiations. These include step-wedge filters, transmission crystal spectroscopy, single-hit CCD detectors, and streaked scintillating detection. While none of the diagnostics recorded conclusive results, the step-wedge filter that is sensitive to the energy range between 100 keV and 700 keV shows a signal around 500 keV that is clearly departing from a pure Bremsstrahlung spectrum and that we ascribe to annihilation radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A protection system for the JET ITER-like wall based on imaging diagnostics

The new JET ITER-like wall (made of beryllium and tungsten) is more fragile than the former carbon fiber composite wall and requires active protection to prevent excessive heat loads on the plasma facing components (PFC). Analog CCD cameras operating in the near infrared wavelength are used to measure surface temperature of the PFCs. Region of interest (ROI) analysis is performed in real time and the maximum temperature measured in each ROI is sent to the vessel thermal map. The protection of the ITER-like wall system started in October 2011 and has already successfully led to a safe landing of the plasma when hot spots were observed on the Be main chamber PFCs. Divertor protection is more of a challenge due to dust deposits that often generate false hot spots. In this contribution we describe the camera, data capture and real time processing systems. We discuss the calibration strategy for the temperature measurements with cross validation with thermal IR cameras and bi-color pyrometers. Most importantly, we demonstrate that a protection system based on CCD cameras can work and show examples of hot spot detections that stop the plasma pulse. The limits of such a design and the associated constraints on the operations are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel technique for single-shot energy-resolved 2D x-ray imaging of plasmas relevant for the inertial confinement fusion

A novel x-ray diagnostic of laser-fusion plasmas is described, allowing 2D monochromatic images of hot, dense plasmas to be obtained in any x-ray photon energy range, over a large domain, on a single-shot basis. The device (named energy-encoded pinhole camera) is based upon the use of an array of many pinholes coupled to a large area CCD camera operating in the single-photon mode. The available x-ray spectral domain is only limited by the quantum efficiency of scientific-grade x-ray CCD cameras, thus extending from a few keV up to a few tens of keV. Spectral 2D images of the emitting plasma can be obtained at any x-ray photon energy provided that a sufficient number of photons had been collected at the desired energy. Results from recent inertial confinement fusion related experiments will be reported in order to detail the new diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗