Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAPACITANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Phase-Discriminating Capacitive Sensor System

Crosstalk eliminated by maintaining voltages on all electrodes at same amplitude, phase, and frequency. Each output feedback-derived control voltage, change of which indicates proximity-induced change in capacitance of associated sensing electrode. Sensors placed close together, enabling imaging of sort. Images and/or output voltages used to guide robots in proximity to various objects.

Vranish, John M.↗

Capacitive Proximity Sensors With Additional Driven Shields

Improved capacitive proximity sensors constructed by incorporating one or more additional driven shield(s). Sensitivity and range of sensor altered by adjusting driving signal(s) applied to shield(s). Includes sensing electrode and driven isolating shield that correspond to sensing electrode and driven shield.

Mcconnell, Robert L.↗

Phase discriminating capacitive array sensor system

A phase discriminating capacitive sensor array system which provides multiple sensor elements which are maintained at a phase and amplitude based on a frequency reference provided by a single frequency stabilized oscillator. Sensor signals provided by the multiple sensor elements are controlled by multiple phase control units, which correspond to the multiple sensor elements, to adjust the sensor signals from the multiple sensor elements based on the frequency reference. The adjustment made to the sensor signals is indicated by output signals which indicate the proximity of the object. The output signals may also indicate the closing speed of the object based on the rate of change of the adjustment made, and the edges of the object based on a sudden decrease in the adjustment made.

Vranish, John M.↗

Capacitive Sensor With Driven Shields And Bridge Circuit

Like other capaciflectors described in prior articles in NASA Tech Briefs, this one includes sensing electrode driven by alternating voltage, giving rise to electric field in vicinity of electrode; object entering electric field detected by its effect on capacitance between sensing electrode and electrical ground. Also includes shielding electrode (in this case, driven shield 1), excited via voltage follower at same voltage as that applied to sensing electrode to concentrate more of electric field outward from sensing electrode, increasing sensitivity and range of sensor. Because shielding electrode driven via voltage follower, it does not present significant electrical load to source of alternating voltage.

Vranish, John M.↗

Ultra-High-Frequency Capacitive Displacement Sensor

Improved class of compact, high-resolution capacitive displacement sensors operates at excitation frequency of 915 MHz and measures about 7.5 by 4 by 2 centimeters. Contains commercially available 915-MHz oscillator and transmission-line resonator. Resonator contains stripline inductor in addition to variable capacitor. Ultrahigh excitation frequency offers advantages of resolution and frequency response. Not deleteriously affected by mechanical overdriving, or contact between electrodes.

Vanzandt, Thomas R.↗

Capacitive Sensors And Targets Would Measure Alignments

Multiple capacitive sensors and active targets used to measure distance between, and relative orientation of, two objects. Sensed target signals processed and used by control systems to align objects to be joined. Shapes, sizes, and layouts of sensors and targets optimized for specific application. Particular layout of targets and sensors enables determination of relative position and orientation of two objects in all six degrees of freedom.

Jenstrom, Del T.↗

Steerable Capacitive Proximity Sensor

Steerable capacitive proximity sensor of "capaciflector" type based partly on sensing units described in GSC-13377 and GSC-13475. Position of maximum sensitivity adjusted without moving sensor. Voltage of each driven shield adjusted separately to concentrate sensing electric field more toward one side or other.

Jenstrom, Del T.↗

Capacitive acoustic wave detector and method of using same

A capacitor having two substantially parallel conductive faces is acoustically coupled to a conductive sample end such that the sample face is one end of the capacitor. A non-contacting dielectric may serve as a spacer between the two conductive plates. The formed capacitor is connected to an LC oscillator circuit such as a Hartley oscillator circuit producing an output frequency which is a function of the capacitor spacing. This capacitance oscillates as the sample end coating is oscillated by an acoustic wave generated in the sample by a transmitting transducer. The electrical output can serve as an absolute indicator of acoustic wave displacement.

Yost, William T.↗

Efficient modeling of interconnects and capacitive discontinuities in high-speed digital circuits

Modeling of interconnects and associated discontinuities with the recent advances high-speed digital circuits has gained a considerable interest over the last decade although the theoretical bases for analyzing these structures were well-established as early as the 1960s. Ongoing research at the present time is focused on devising methods which can be applied to more general geometries than the ones considered in earlier days and, at the same time, improving the computational efficiency and accuracy of these methods. In this thesis, numerically efficient methods to compute the transmission line parameters of a multiconductor system and the equivalent capacitances of various strip discontinuities are presented based on the quasi-static approximation. The presented techniques are applicable to conductors embedded in an arbitrary number of dielectric layers with two possible locations of ground planes at the top and bottom of the dielectric layers. The cross-sections of conductors can be arbitrary as long as they can be described with polygons. An integral equation approach in conjunction with the collocation method is used in the presented methods. A closed-form Green's function is derived based on weighted real images thus avoiding nested infinite summations in the exact Green's function; therefore, this closed-form Green's function is numerically more efficient than the exact Green's function. All elements associated with the moment matrix are computed using the closed-form formulas. Various numerical examples are considered to verify the presented methods, and a comparison of the computed results with other published results showed good agreement.

Oh, K. S.↗

Capacitive Sensing Of Gaseous Fraction In Two-Phase Flow

Instrument makes nonintrusive, real-time capacitive measurements to determine volume fraction of vapor or other gas in flowing, electrically nonconductive liquid/gas mixture. Works even with liquids having relatively low permittivities. Useful for measuring proportions of vapor in boiling, condensing, and flowing heat-transfer fluids and in cryogenic fluids.

Crowley, Christopher J.↗

Measuring Work Functions Of "Dirty" Surfaces With A Vibrating Capacitive Probe

Apparatus measures work function of possibly contaminated surface of specimen of metal or other electrically conductive material. Measures work function of specimen indirectly, by vibrating capacitive measurement of contact potential. Work function of specimen affected by microstructure and by contamination.

Yost, William T.↗

Design and Application of a Collocated Capacitance Sensor for Magnetic Bearing Spindle

This paper presents a collocated capacitance sensor for magnetic bearings. The main feature of the sensor is that it is made of a specific compact printed circuit board (PCB). The signal processing unit has been also developed. The results of the experimental performance evaluation on the sensitivity, resolution and frequency response of the sensor are presented. Finally, an application example of the sensor to the active control of a magnetic bearing is described.

Shin, Dongwon↗

Capacitive Extensometer Particularly Suited for Measuring in Vivo Bone Strain

The present invention provides for in vivo measurements of the principal strain magnitudes and directions, and maximum shear strain that occurs in a material, such as human bone, when it is loaded (or subjected to a load). In one embodiment the invention includes a capacitive delta extensometer arranged with six sensors in a three piece configuration, with each sensor of each pair spaced apart from each other by 120 degrees.

Perusek, Gail P.↗

Miniaturized Wilkinson Power Dividers Utilizing Capacitive Loading

This letter reports the miniaturization of a planar Wilkinson power divider by capacitive loading of the quarter wave transmission lines employed in conventional Wilkinson power dividers. Reduction of the transmission line segments from lambda/4 to between lambda/5 and lambda/12 are reported here. The input and output lines at the three ports and the lines comprising the divider itself are coplanar waveguide (CPW) and asymmetric coplanar stripline (ACPS), respectively. The 10 GHZ power dividers are fabricated on high resistivity silicon (HRS) and alumina wafers. These miniaturized dividers are 74% smaller than conventional Wilkinson power dividers, and have a return loss better than +30 dB and an insertion loss less than 0.55 dB. Design equations and a discussion about the effect of parasitic reactance on the isolation are presented for the first time.

Scardelletti, Maximilian C.↗

Capacitive Extensometer

The present invention provides for measurements of the principal strain magnitudes and directions, and maximum shear strain that occurs in a porous specimen, such as plastic, ceramic or porous metal, when it is loaded (or subjected to a load). In one embodiment the invention includes a capacitive delta extensometer arranged with six sensors in a three piece configuration, with each sensor of each pair spaced apart from each other by a predetermined angle, such as 120 degrees.

Gail P Perusek↗

The effects of hindlimb unweighting on the capacitance of rat small mesenteric veins

Microgravity is associated with an impaired cardiac output response to orthostatic stress. Mesenteric veins are critical in modulating cardiac filling through venoconstriction. The purpose of this study was to determine the effects of simulated microgravity on the capacitance of rat mesenteric small veins. We constructed pressure-diameter relationships from vessels of 21-day hindlimb-unweighted (HLU) rats and control rats by changing the internal pressure and measuring the external diameter. Pressure-diameter relationships were obtained both before and after stimulation with norepinephrine (NE). The pressure-diameter curves of HLU vessels were shifted to larger diameters than control vessels. NE (10(-4) M) constricted veins from control animals such that the pressure-diameter relationship was significantly shifted downward (i.e., to smaller diameters at equal pressure). NE had no effect on vessels from HLU animals. These results indicate that, after HLU, unstressed vascular volume may be increased and can no longer decrease in response to sympathetic stimulation. This may partially underlie the mechanism leading to the exaggerated fall in cardiac output and stroke volume seen in astronauts during an orthostatic stress after exposure to microgravity.

Non-NASA Center↗

Determination of H2O and CO2 concentrations in fluid inclusions in minerals using laser decrepitation and capacitance manometer analysis

Water and carbon dioxide concentrations within individual and selected groups of fluid inclusions in quartz were analyzed by using laser decrepitation and quantitative capacitance manometer determination. The useful limit of detection (calculated as ten times the typical background level) is about 5 x 10(-10) mol of H2O and 5 x 10(-11) mol of CO2; this H2O content translates into an aqueous fluid inclusion approximately 25 micrometers in diameter. CO2/H2O determinations for 38 samples (100 separate measurements) have a range of H2O amounts of 5.119 x 10(-9) to 1.261 x 10(-7) mol; CO2 amounts of 7.216 x 10(-10) to 1.488 x 10(-8) mol, and CO2/H2O mole ratios of 0.011 to 1.241. Replicate mole ratio determinations of CO2/H2O for three identical (?) clusters of inclusions in quartz have average mole ratios of 0.0305 +/- 0.0041 1 sigma. Our method offers much promise for analysis of individual fluid inclusions, is sensitive, is selective when the laser energy is not so great as to melt the mineral (laser pits approximately 50 micrometers in diameter), and permits rapid analysis (approximately 1 h per sample analysis).

Water/analysis↗

Efficacy of compression of different capacitance beds in the amelioration of orthostatic hypotension

Orthostatic hypotension (OH) is the most disabling and serious manifestation of adrenergic failure, occurring in the autonomic neuropathies, pure autonomic failure (PAF) and multiple system atrophy (MSA). No specific treatment is currently available for most etiologies of OH. A reduction in venous capacity, secondary to some physical counter maneuvers (e.g., squatting or leg crossing), or the use of compressive garments, can ameliorate OH. However, there is little information on the differential efficacy, or the mechanisms of improvement, engendered by compression of specific capacitance beds. We therefore evaluated the efficacy of compression of specific compartments (calves, thighs, low abdomen, calves and thighs, and all compartments combined), using a modified antigravity suit, on the end-points of orthostatic blood pressure, and symptoms of orthostatic intolerance. Fourteen patients (PAF, n = 9; MSA, n = 3; diabetic autonomic neuropathy, n = 2; five males and nine females) with clinical OH were studied. The mean age was 62 years (range 31-78). The mean +/- SEM orthostatic systolic blood pressure when all compartments were compressed was 115.9 +/- 7.4 mmHg, significantly improved (p < 0.001) over the head-up tilt value without compression of 89.6 +/- 7.0 mmHg. The abdomen was the only single compartment whose compression significantly reduced OH (p < 0.005). There was a significant increase of peripheral resistance index (PRI) with compression of abdomen (p < 0.001) or all compartments (p < 0.001); end-diastolic index and cardiac index did not change. We conclude that denervation increases vascular capacity, and that venous compression improves OH by reducing this capacity and increasing PRI. Compression of all compartments is the most efficacious, followed by abdominal compression, whereas leg compression alone was less effective, presumably reflecting the large capacity of the abdomen relative to the legs.

Non-NASA Center↗