Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Numerical Simulation on Liquid Hydrogen Chill-Down Process of Vertical Pipeline

In order to improve the cryogenic propellant management technologies for a liquid hydrogen rocket with high specific impulse, JAXA, the University of Tokyo, and the NASA Glenn Research Center have jointly organized a multi-agency model validation collaboration project. As part of this project, JAXA's boiling simulation was validated with NASA's experimental data on vertical pipeline chill-down. Simulation results were in good agreement with the experimental data obtained using an improved boiling model to reproduce the spray flow. This activity achieved liquid hydrogen turbo-pump simulation at JAXA for grasping the boiling flow phenomenon from engine cut-off to re-ignition. This joint research resulted in an international cooperative relationship for discussing the cryogenic propellant management technologies necessary to develop next-generation liquid rockets.

Umemura, Yutaka↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank

This paper presents a multi-node finite volume model of the chilling and filling of a cryogenic tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. Vented Chill and No Vent Fill (VCNVF) tests were conducted at Marshall Space Flight Center where a flight-like tank was filled with liquid nitrogen from a supply tank. In the VCNVF tests, the tank was partially chilled while the vent valve was open. After the partial chilling, the vent valve was closed and the tank was filled without any venting. An integrated numerical model of the test set up was developed. The model included the transfer line from the supply tank, the target tank with the spray nozzle and solid walls, and the discharge line with the vent valve. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor in the tank when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall and ullage temperature in the tank were compared with the test data.

Alok Majumdar↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank

This paper presents a multi-node finite volume model of the chilling and filling of a cryogenic tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. Vented Chill and No Vent Fill (VCNVF) tests were conducted at Marshall Space Flight Center where a flight-like tank was filled with liquid nitrogen from a supply tank. In the VCNVF tests, the tank was partially chilled while the vent valve was open. After the partial chilling, the vent valve was closed and the tank was filled without any venting. An integrated numerical model of the test set up was developed. The model included the transfer line from the supply tank, the target tank with the spray nozzle and solid walls, and the discharge line with the vent valve. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor in the tank when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall and ullage temperature in the tank were compared with the test data.

Alok Majumdar↗

Summary of Testing Results for the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The baseline SHIIVER design consists of uninsulated structural skirts attached to a propellant tank insulated with polyurethane Spray-On Foam Insulation (SOFI). The initial testing of the SHIIVER hardware was with liquid hydrogen and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI on the tank domes, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full, with and without MLI installed on the domes. The MLI installed on the domes reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed after exposure to the acoustic environment. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads

SHIIVER↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank with Thermo-dynamic Vent System Assisted Injector

This paper presents a multi-node finite volume model of No Vent Filling (NVF) of a cryogenic tank with Thermo-dynamic Vent System (TVS) assisted injector, using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. NVF tests were conducted in a CRYOgenic Orbital Testbed (CRYOTE) tank which was filled by liquid nitrogen using a TVS assisted injector with vent valve closed during the entire filling process. In TVS assisted injector, the liquid flow splits into two streams: one stream is routed to a Joule-Thomson (J-T) orifice where the flow immediately flashes from liquid to vapor or two phase mixture because the downstream to J-T leg is maintained at vacuum level.; the other stream is injected into the tank after being cooled by cold vapor of J-T leg in a heat exchanger. The flow through J-T leg is also used to cool the outer metal matrix of the injector which in turn cools the vapor in the tank ullage. The cooling of vapor in the ullage by cold injector surface reduces ullage pressure that allows liquid to enter and fill the tank. An integrated numerical model of the test set up was developed. The model included the dual lines of TVS assisted injector, tank and tank wall. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor at ullage-injector interface and when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall temperature in the tank were compared with the test data.

Alok Majumdar↗

Case Study of Using Flocad to Model a Ground Test Station Ln2 Heat Exchanger

This paper presents a case study of using FLOCAD to model the heat transfer and boiling flow behavior of a Liquid Nitrogen (LN2) ground station equipment heat exchanger. The unique aspect of this work is that is one of very few studies documenting the use of FLOCAD in the spacecraft thermal control community. The results of the simulations described herein were used to guide and plan the execution of thermal vacuum testing spacecraft hardware using a ground test heat exchanger such as the one modeled herein. The paper will review the theory of two-phase boiling flow and correlations used by SINDA/FLUINT as well as the terminology and nomenclature used within Thermal Desktop / FLOCAD regarding two-phase boiling flow heat transfer modeling and simulation. Results for using the ground station heat exchanger as a heat sink in a thermal vacuum test set up are shown in order to demonstrate the set-up and execution of a typical FLOCAD model. Results indicate that properly modeling of the two-phase behavior is critical in order to ascertain the time constant associated with the heat exchanger, as well as understanding the temperature distribution across the test equipment and prediction of required LN2 flowrates to be used during testing. The paper is meant to augment the FLOCAD user’s manual and serve as a tutorial for thermal engineers and analysts wishing to learn and apply FLOCAD to industrial problems.

Anderson, Kevin R.↗

Interfacial thermodynamics of cryogenic fluids: The effect on non-condensable gas on fluid storage

Propellant tanks that contain cryogenic fluids (CFs) in low gravity conditions are usually pressurized with non-condensable (NC) gases for fast extraction. Unfortunately, the presence of NC gases causes CFs to exhibit higher boil-offs compared to pure CF systems. For optimal utilization of the cryogenic fuels, these higher boil-off rates must be minimized. Our goal is to quantify the effects NC gases have on the evaporation and condensation dynamics of CFs to develop strategies that mitigate the higher boil-offs. The hypothesis is that the NC gas accumulates around the CF’s liquid vapor interface in the Knudsen layer, creating a kinetic barrier for both evaporation and condensation. Testing this hypothesis with experimental methods is difficult due to the transient nature of the Knudsen layer, which is only a few nanometers thick. Furthermore, experimental capabilities are limited in low gravity conditions and extremely expensive. Accordingly, we approach this problem from a theoretical perspective. In this study, we employ molecular dynamics (MD) simulations to probe the interfacial mechanisms that affect CF’s evaporation and condensation at varying concentrations of NC gases. Specifically, we use nitrogen (N2) and oxygen (O2) as our CFs and neon (Ne) as our NC gas. Using MD simulations, we show that Ne accumulates at N2 liquid vapor interface across a wide range of Ne concentrations, thereby impeding mass transport of N2. Our simulations allow for direct computation of the molar flux as well as the mass accommodation coefficient (MAC) which can then be used as input parameters to continuum fluid dynamics (CFD) models for optimal storage tank design.

Michael Robert DeLyser↗

Microbial Survival in Brewed Tea

Loose-leaf bagged tea is a commonly requested crew food item that comprises up to 7% of samples in the spaceflight food system. Tea preferences are typically specific and vary between different crew members, and there is significant interest to provide preferred food selections for the physical and mental wellbeing of the crew. Loose leaf bagged teas are made from herbs and spices that frequently have high microbial loads which do not meet the microbiological standards outlined in NASA-STD-3001. The food industry on earth does not require standards for microbial load of loose-leaf teas, because tea is brewed in boiling (100C) water, which is assumed to reduce the number of microorganisms. However, hot water from the ISS PWD is typically dispensed at a temperature between 155F (68C) and 175F (79C), which is below the suggested temperature range for safe brewing (180F/80C – 212F/100C). In this study, a commonly requested chamomile tea bags were infected with Bacillus cereus, a pathogenic, spore forming bacterium known to cause foodborne illness. Brewing B. cereus infected tea bags with boiling (212F/100C) or ISS PWD (155F/68C) temperature water showed no significant reduction in the overall microbial load of the tea (p=0.535). The addition of boiling and ISS PWD temperature water also was not sufficient to kill 100% of the infected B. cereus, and in one case of ISS PWD temperature water, B. cereus was detected at levels above a previously reported infectious dose. This study showed that the microbiological risk associated with drinking brewed tea on ISS is not reduced by the brewing process.

S G Thornhill↗

Endogenous Microbial Survival in Brewed Tea

Loose-leaf bagged tea is a commonly requested beverage item that comprises up to 7% of the microbiological samples from the space food systems. As loose-leaf tea blends often contain herbs and spices that frequently have high microbial loads, they have a high failure rate as defined by the microbiological standards outlined in NASA-STD-3001, which are more stringent than the limits set for industry. Between April 2019 and September 2022, 54.8% of loose-leaf teas submitted for microbiological testing have failed, necessitating the evaluation of a variety of brands and lot numbers of each requested tea type to meet crew preference requests, which are typically specific, resulting in excess labor and material costs to provide a single product for spaceflight consumption. Attempts to identify specific brands or ingredients that are less likely to produce a failure have been unsuccessful, as to date, no trends in those measures have been identified. We have, however, noticed a trend in types of teas (spiced and herbal) which are more likely to fail. Of additional concern, hot water available for brewing tea on ISS is dispensed at a lower temperature than the CDC recommended brewing temperature. In a study we previously reported, we found that that brewing water temperature may not have a significant impact on the number of aerobic bacteria in chamomile tea, as there were no significant differences in the total microbial load between tea brewed with boiling, ISS-like, or room temperature waters. It did appear that ISS temperature water was similarly effective to boiling water against a pathogenic bacterial species. In this study, we aim to assess whether the total number of aerobic bacteria of other high-fail-rate tea types is similarly unaffected when brewing tea in room temperature or boiling water. Data from this study and the previous study, as well as additional analysis of every tea product that has been tested as part of the normal food system since April 2019, will be used to determine the expected typical microbial load for loose-leaf teas, which we will compare to existing industry limits so that we can recommend a new microbiological limit for loose-leaf teas that accurately reflects the true risk of consuming brewed teas in spaceflight.

space flight food↗

Microchannel Geometries for Improved Heat Transfer with Low-GWP refrigerants

Due to efforts aimed at decarbonizing industries, the use of refrigerants with low global warming potential (GWP) is highly recommended in the air-conditioning and refrigeration sectors. Despite possessing low-GWP values of less than 150, hydrofluoroolefins (HFO) exhibit relatively lower heat transfer performance compared to conventional hydrofluorocarbons (HFC) under certain operating conditions. In contrast to HFCs, there is a high demand for enhanced surfaces to meet the needs of heat transfer systems utilizing low GWP refrigerants. Accordingly, this study analyzes the pool boiling performance of low-GWP refrigerants in microchannel geometries. The experiments were carried out at various heat flux levels on both smooth and enhanced surfaces. The pool boiling behavior of low-GWP refrigerant R1234yf was compared to that of R-134a refrigerant in terms of heat transfer coefficient and wall superheat. The results indicate that the heat transfer coefficients of the enhanced surface are significantly higher than those of the smooth surface. Furthermore, the microchannel geometry demonstrated a lower wall superheat compared to the smooth surface. Additionally, a visualization study was performed using a high-speed camera to understand the pool boiling mechanism of low-GWP refrigerants on both smooth and enhanced surfaces.

Murugan, Muneeshwaran↗

On the prediction of critical heat flux using a physics-informed machine learning-aided framework

The critical heat flux (CHF) corresponding to the departure from nucleate boiling (DNB) crisis is essential to the design and safety of a two-phase flow boiling system. Despite the abundance of predictive tools available to the thermal engineering community, the path for an accurate, robust CHF model remains elusive due to lack of consensus on the DNB triggering mechanism. This work aims to apply a physics-informed machine learning (ML)-aided hybrid framework to achieve superior predictive capabilities. Such a hybrid approach takes advantage of existing understanding in the field of interest (i.e., domain knowledge) and uses ML to capture undiscovered information from the mismatch between the actual and domain knowledge-predicted target. A detailed case study is carried out with an extensive DNB-specific CHF database to demonstrate (1) the improved performance of the hybrid approach as compared to traditional domain knowledge-based models, and (2) the hybrid model’s superior generalization capabilities over standalone ML methods across a wide range of flow conditions. The hybrid framework could also readily extend its applicability domain and complexity on the fly, showing an elevated level of flexibility and robustness. Based on the case study conclusions, the window-type extrapolation mapping methodology is further proposed to better inform high-cost experimental work.

42 ENGINEERING↗

Effect of helical micro-fins on two-phase flow behavior of R410A evaporating in horizontal round tubes obtained through visualization

This paper presents a new approach in visualization of the evaporation mechanism and the two phase flow. The visualization test section is a transparent micro-fin tube made by 3D printing. The 3D printing technology helps reproduce the real geometry in commercial metal micro-fin tubes. Even though the wall material is different from the real metal, this new method provides a more complete understanding of the mechanisms of flow boiling and the heat transfer enhancement due to micro-fin geometry. To investigate the effect of micro-fin geometries on two-phase flow behavior, R410A flow boiling experiments are conducted at 1°C saturation temperature and visualized through a clear smooth tube and micro-fin tubes of 0°, 10° and 18° helix angles. The results showed that the annular flow pattern in the helical micro-fin tube occurred at a lower vapor quality than the smooth and axial micro-fin tubes. Helix angle affects the transition boundary of stratified wavy flow to wavy annular flow, which shifts downward (to lower mass flux and vapor quality conditions) as the helix angle increases. Other transitions are not significantly affected by the helix angle. Helical micro-fin tubes with different groove directions were made to understand the flow behavior on the upward side and downward side of the tube.

3D printing↗

Diabatic visualization shows effects of micro-fins on evaporation of R410A: Smooth, axial micro-fin, and helical micro-fin tubes

A novel approach to visualize the flow boiling inside a clear micro-fin tube under diabatic conditions is presented. Transparent smooth, axial micro-fin, and helical micro-fin tubes are made by 3D printing. The 3D printed tube is placed inside a glass tube and heated by the transparent secondary fluid flowing between the two tubes for providing the evaporation conditions and transparency. R410A flow boiling and the flow patterns in the three geometries captured with a high speed camera are compared. The experimental results show that micro-fin geometry influences flow behavior. Bubbles are mainly generated in the groove region due to a higher superheat than the fin region. Some of the liquid refrigerant is trapped in the grooves of the upper part of the micro-fin tube when the slug flow is present, and bubbles are generated in this thin liquid layer. In addition, the bubbles in the helical micro-fin tube are easier to merge because of the obstacle of the fin geometry for the bubble flowing path. As the two bubble merge, the conversion of surface free energy causes the bubble to travel with a higher velocity.

3D printed↗

Enabling BWR fuel rod analysis in the BISON fuel performance code

Nuclear fuel vendors around the world are pursuing approaches to sustain the existing nuclear reactor fleet consisting primarily of pressurized-water reactors (PWRs) and boiling-water reactors (BWRs). To support the industry's efforts, advanced modeling and simulation tools need to be capable of analyzing both legacy reactor concepts. BWR fuel rods are significantly different than those used in PWRs, which can affect fuel performance analysis. BWR fuel rods include: (1) an extensive use of gadolinia dopant as a burnable absorber, (2) an axial variation in fuel enrichment and gadolinia content, (3) the inclusion of a liner on the inner cladding surface to mitigate the impact of pellet-clad mechanical interaction (which impacts hydrogen and hydride distribution), (4) a lower initial fill gas pressure, (5) bottom-entry control rods, and (6) a lower coolant pressure that results in the two-phase flow boiling phenomenon. Although the primary focus of BISON has been in the area of PWR and advanced reactor fuel analyses, this paper presents the developments in BISON to support BWR fuel performance analysis. An overview of the models that account for the effects of gadolinia is highlighted. Internal mesh generation capabilities to include a liner is presented. Normal operating and transient (reactivity insertion accident) demonstration problems are presented to illustrate the impact of gadolinia, the hydrogen and hydride evolution due to the presence of the liner, and BISON's ability to simulate axially varying enrichments and dopant concentration. Bottom-entry control effects are captured by the axial power peaking factors present in the demonstration cases. Comparisons to integral experiments from the Halden IFA-681 experiments are discussed as initial validation. Reasonable comparisons are obtained for fuel centerline temperature and rod internal pressure as a function of time. In conclusion, simulations of additional experiments containing Gd 2 O 3 -bearing fuel are necessary to completely validate the code for BWR applications.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tree-Based Ensemble Learning Models for Wall Temperature Predictions in Post-Critical Heat Flux Flow Regimes at Subcooled and Low-Quality Conditions

Accurately predicting post-critical heat flux (CHF) heat transfer is an important but challenging task in water-cooled reactor design and safety analysis. Although numerous heat transfer correlations have been developed to predict post-CHF heat transfer, these correlations are only applicable to relatively narrow ranges of flow conditions due to the complex physical nature of the post-CHF heat transfer regimes. In this paper, a large quantity of experimental data is collected and summarized from the literature for steady-state subcooled and low-quality film boiling regimes with water as the working fluid in vertical tubular test sections. In addition, a low-quality water film boiling (LWFB) database is consolidated with a total of 22,813 experimental data points, which cover a wide flow range of the system pressure from 0.1 to 9.0 MPa, mass flux from 25 to 2750 kg/m 2 s, and inlet subcooling from 1 to 70 °C. Two machine learning (ML) models, based on random forest (RF) and gradient boosted decision tree (GBDT), are trained and validated to predict wall temperatures in post-CHF flow regimes. The trained ML models demonstrate significantly improved accuracies compared to conventional empirical correlations. To further evaluate the performance of these two ML models from a statistical perspective, three criteria are investigated and three metrics are calculated to quantitatively assess the accuracy of these two ML models. For the full LWFB database, the root-mean-square errors between the measured and predicted wall temperatures by the GBDT and RF models are 5.7% and 6.2%, respectively, confirming the accuracy of the two ML models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling of Liquid Hydrogen Tank Cooled with Para-Orthohydrogen Conversion

With the accelerating development of liquid-hydrogen storage facilities, the problem of boil-off hydrogen losses becomes very important. A promising method to reduce these losses is to utilize the endothermic para-orthohydrogen conversion of vented hydrogen, which can effectively decrease heat loads on a hydrogen tank. To model such a process, a hybrid computational model has been developed, based on the application of computational fluid dynamics for an ullage space, where knowledge of thermal stratification is important, and reduced-order models for other system elements. The simulation results for a spheroidal tank in selected conditions indicated a 10–25% reduction of boil-off losses due to cooling produced by vented hydrogen undergoing para-ortho-conversion.

08 HYDROGEN↗