Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Band Pass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

SEXTANT - Station Explorer for X-ray Timing and Navigation Technology

The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron-star Interior Composition Explorer (NICER) mission, which is scheduled to launch in late 2016 and will be hosted as an externally attached payload on the International Space Station (ISS) via the ExPRESS Logistics Carrier (ELC). During NICER's 18-month baseline science mission to understand ultra-dense matter though observations of neutron stars in the soft X-ray band, SEXTANT will, for the first-time, demonstrate real-time, on-board X-ray pulsar navigation, which is a significant milestone in the quest to establish a GPS-like navigation capability that will be available throughout our Solar System and beyond. Along with NICER, SEXTANT has proceeded through Phase B, Mission Definition, and received numerous refinements in concept of operation, algorithms, flight software, ground system, and ground test capability. NICER/SEXTANT's Phase B work culminated in NASA's confirmation of NICER to Phase C, Design and Development, in March 2014. Recently, NICER/SEXTANT successfully passed its Critical Design Review and SEXTANT received continuation approval in September 2014. In this paper, we describe the X-ray pulsar navigation concept and provide a brief history of previous work, and then summarize the SEXTANT technology demonstration objective, hardware and software components, and development to date.

X-rays↗

Reflective Fiber Temperature Probe Based on Localized Surface Plasmon Resonance towards Low-Cost and Wireless Interrogation

Reflection fiber temperature sensors functionalized with plasmonic nanocomposite material using intensity-based modulation are demonstrated for the first time. Characteristic temperature optical response of the reflective fiber sensor is experimentally tested using Au-incorporated nanocomposite thin films deposited on the fiber tip, and theoretically validated using a thin-film-optic-based optical waveguide model. By optimizing the Au concentration in a dielectric matrix, Au nanoparticles (NP) exhibit a localized surface plasmon resonance (LSPR) absorption band in a visible wavelength that shows a temperature sensitivity ~0.025%/°C as a result of electron–electron and electron–phonon scattering of Au NP and the surrounding matrix. Detailed optical material properties of the on-fiber sensor film are characterized using scanning electron microscopy (SEM) and focused-ion beam (FIB)-assisted transmission electron microscopy (TEM). Airy’s expression of transmission and reflection using complex optical constants of layered media is used to model the reflective optical waveguide. A low-cost wireless interrogator based on a photodiode transimpedance-amplifier (TIA) circuit with a low-pass filter is designed to integrate with the sensor. The converted analog voltage is wirelessly transmitted via 2.4 GHz Serial Peripheral Interface (SPI) protocols. Feasibility is demonstrated for portable, remotely interrogated next-generation fiber optic temperature sensors with future capability for monitoring additional parameters of interest.

47 OTHER INSTRUMENTATION↗

X-Band Acquisition Aid Software

The X-band Acquisition Aid (AAP) software is a low-cost acquisition aid for the Deep Space Network (DSN) antennas, and is used while acquiring a spacecraft shortly after it has launched. When enabled, the acquisition aid provides corrections to the antenna-predicted trajectory of the spacecraft to compensate for the variations that occur during the actual launch. The AAP software also provides the corrections to the antenna-predicted trajectory to the navigation team that uses the corrections to refine their model of the spacecraft in order to produce improved antenna-predicted trajectories for each spacecraft that passes over each complex. The software provides an automated Acquisition Aid receiver calibration, and provides graphical displays to the operator and remote viewers via an Ethernet connection. It has a Web server, and the remote workstations use the Firefox browser to view the displays. At any given time, only one operator can control any particular display in order to avoid conflicting commands from more than one control point. The configuration and control is accomplished solely via the graphical displays. The operator does not have to remember any commands. Only a few configuration parameters need to be changed, and can be saved to the appropriate spacecraft-dependent configuration file on the AAP s hard disk. AAP automates the calibration sequence by first commanding the antenna to the correct position, starting the receiver calibration sequence, and then providing the operator with the option of accepting or rejecting the new calibration parameters. If accepted, the new parameters are stored in the appropriate spacecraft-dependent configuration file. The calibration can be performed on the Sun, greatly expanding the window of opportunity for calibration. The spacecraft traditionally used for calibration is in view typically twice per day, and only for about ten minutes each pass.

Britcliffe, Michael J.↗

Laser schlieren crystal monitor

A system and method for monitoring the state of a crystal which is suspended in a solution is described which includes providing a light source for emitting a beam of light along an optical axis. A collimating lens is arranged along the optical axis for collimating the emitted beam to provide a first collimated light beam consisting of parallel light rays. By passing the first collimated light beam through a transparent container, a number of the parallel light rays are deflected off the surfaces of said crystal being monitored according to the refractive index gradient to provide a deflected beam of deflected light rays. A focusing lens is arranged along optical axis for focusing the deflected rays towards a desired focal point. A knife edge is arranged in a predetermined orientation at the focal point; and a screen is provided. A portion of the deflected beam is blocked with the knife edge to project only a portion of the deflected beam. A band is created at one edge of the image of the crystal which indicates the state of change of the surface of the crystal being monitored.

Owen, Robert B.↗

Multiple-etalon systems for the Advanced Technology Solar Telescope

Multiple etalon systems are discussed that meet the science requirements for a narrow-passband imaging system for the 4-meter National Solar Observatory (NSO)/Advance Technology Solar Telescope (ATST). A multiple etalon system can provide an imaging interferometer that works in four distinct modes: as a spectro-polarimeter, a filter-vector magnetograph, an intermediate-band imager, and broadband high-resolution imager. Specific dual and triple etalon configurations are described that provide a spectrographic passband of 2.0-3.5 micron and reduce parasitic light levels to 10(exp -4) as required for precise polarization measurement, e.g., Zeeman measurements of magnetic sensitive lines. A TESOS-like (Telecentric Etalon SOlar Spectrometer) triple etalon system provides a spectral purity of 10(exp -5). The triple designs have the advantage of reducing the finesse requirement on each etalon; allow the use of more stable blocking filters, and have very high spectral purity. A dual-etalon double-pass (Cavallini-like) system can provide a competing configuration. Such a dual-etalon design can provide high contrast. The selection of the final focal plane instrument will depend on a trade-off between an ideal instrument and practical reality. The trade study will include the number of etalons, their aperture sizes, complexities of the optical train, number of blocking filters, configuration of the electronic control system, computer interfaces, temperature controllers, etalon controllers, and their associated feedback electronics. The heritage of single and multiple etalon systems comes from their use in several observatories, including the Marshall Space Flight Center (MSFC) Solar Observatory, Sacramento Peak Observatory (NSO), and Kiepenheuer-Institut fur Sonnenphysik (KIS, Germany), Mees Solar Observatory (University of Hawaii), and Arcetri Astrophysical Observatory (Italy). The design of the ATST multiple etalon system will benefit from the experience gained at these observatories.

Gary, G. Allen↗

Seasonal Changes in Titan's Southern Stratosphere

In August 2009 Titan passed through northern spring equinox, and the southern hemisphere passed into fall. Since then, the moon's atmosphere has been closely watched for evidence of the expected seasonal reversal of stratospheric circulation, with increased northern insolation leading to upwelling, and consequent downwelling at southern high latitudes. If the southern winter mirrors the northern winter, this circulation will be traced by increases in short-lived gas species advected downwards from the upper atmosphere to the stratosphere. The Cassini spacecraft in orbit around Saturn carries on board the Composite Infrared Spectrometer (CIRS), which has been actively monitoring the trace gas populations through measurement of the intensity of their infrared emission bands (7-1000 micron). In this presentation we will show fresh evidence from recent CIRS measurements in June 2012, that the shortest-lived and least abundant minor species (C3H4, C4H2, C6H6, HC3N) are indeed increasing dramatically southwards of 50S in the lower stratosphere. Intriguingly, the more stable gases (C2H2, HCN, CO2) have yet to show this trend, and continue to exhibit their 'summer' abundances, decreasing towards the south pole. Possible chemical and dynamical explanations of these results will be discussed , along with the potential of future CIRS measurements to monitor and elucidate these seasonal changes.

Nixon, C. A.↗

Retrieval of Aerosol Optical Properties under Thin Cirrus from MODIS

Retrieval of aerosol optical properties using shortwave bands from passive satellite sensors, such as MODIS, is typically limited to cloud-free areas. However, if the clouds are thin enough (i.e. thin cirrus) such that the satellite-observed reflectance contains signals under the cirrus layer, and if the optical properties of this cirrus layer are known, the TOA reflectance can be corrected for the cirrus layer to be used for retrieving aerosol optical properties. To this end, we first correct the TOA reflectances in the aerosol bands (0.47, 0.55, 0.65, 0.86, 1.24, 1.63, and 2.12 micron for ocean algorithm and 0.412, 0.47, and 0.65 micron for deep blue algorithm) for the effects of thin cirrus using 1.38 micron reflectance and conversion factors that convert cirrus reflectance in 1.38 micron band to those in aerosol bands. It was found that the conversion factors can be calculated by using relationships between reflectances in 1.38 micron band and minimum reflectances in the aerosol bands (Gao et al., 2002). Refer to the example in the figure. Then, the cirrus-corrected reflectance can be calculated by subtracting the cirrus reflectance from the TOA reflectance in the optically thin case. A sensitivity study suggested that cloudy-sky TOA reflectances can be calculated with small errors in the form of simple linear addition of cirrus-only reflectances and clear-sky reflectances. In this study, we correct the cirrus signals up to TOA reflectance at 1.38 micron of 0.05 where the simple linear addition is valid without extensive radiative transfer simulations. When each scene passes the set of tests shown in the flowchart, the scene is corrected for cirrus contamination and passed into aerosol retrieval algorithms.

MODIS↗

Timing Calibration of the NuSTAR X-Ray Telescope

The Nuclear Spectroscopic Telescope Array (NuSTAR) mission is the first focusing X-ray telescope in the hard X-ray (3–79 keV) band. Among the phenomena that can be studied in this energy band, some require high time resolution and stability: rotation-powered and accreting millisecond pulsars, fast variability from black holes and neutron stars, X-ray bursts, and more. Moreover, a good alignment of the timestamps of X-ray photons to UTC is key for multi-instrument studies of fast astrophysical processes. In this paper, we describe the timing calibration of the NuSTAR mission. In particular, we present a method to correct the temperature-dependent frequency response of the on-board temperature-compensated crystal oscillator. Together with measurements of the spacecraft clock offsets obtained during downlinks passes, this allows a precise characterization of the behavior of the oscillator. The calibrated NuSTAR event timestamps for a typical observation are shown to be accurate to a precision of ∼65 μs.

Matteo Bachetti↗

Radar systems for the water resources mission. Volume 4: Appendices E-I

The use of a scanning antenna beam for a synthetic aperture system was examined. When the resolution required was modest, the radar did not use all the time the beam was passing a given point on the ground to build a synthetic aperture, so time was available to scan the beam to other positions and build several images at different ranges. The scanning synthetic-aperture radar (SCANSAR) could achieve swathwidths of well over 100 km with modest antenna size. Design considerations for a SCANSAR for hydrologic parameter observation are presented. Because of the high sensitivity to soil moisture at angles of incidence near vertical, a 7 to 22 deg swath was considered for that application. For snow and ice monitoring, a 22 to 37 deg scan was used. Frequencies from X-band to L-band were used in the design studies, but the proposed system operated in C-band at 4.75 GHz. It achieved an azimuth resolution of about 50 meters at all angles, with a range resolution varying from 150 meters at 7 deg to 31 meters at 37 deg. The antenna required an aperture of 3 x 4.16 meters, and the average transmitter power was under 2 watts.

Moore, R. K.↗

Studies of surface adsorbate electronic structure and femtochemistry at the fundamental length and time scales. Final report

The electronic structure and ultrafast (10-15 s-femtosecond timescale) electron dynamics were investigated for clean and atom/molecule covered metal surfaces. The studies were performed by scanning tunneling microscopy (STM) to measure the structure of adsorbed atoms and molecules on metal surfaces, and to investigate their electronic properties. The electronic structure of the observed molecular networks was calculated by electronic structure theory in collaboration with Prof. Jin Zhao, who is a long-time collaborator, a Professor at the University of Science and Technology of China, and holds an Adjunct Professorship at the University of Pittsburgh. We also investigated the electronic properties of C60 molecules when they are templated by corrugated black phosphorous surfaces. We found unexpected charge delocalization that is enabled by the templating. This research was done in collaboration with Professor Min Feng at the Wuhan University, and who also holds an Adjunct Professorship at the University of Pittsburgh. Moreover, the electronic structure and electron dynamics in metal surfaces were investigated by time-resolved photoemission electron spectroscopy. The focus of ultrafast spectroscopy has been on the plasmonic response of silver surfaces. One direction has been to develop multidimensional (energy, momentum, and time) photoelectron spectroscopy of the coherent response of solid surfaces. This method was applied to study the collective electron excitations known generally as plasmons, which screen optical fields from penetration into metals. Although this collective response has been known for more than 60 years and is used extensively to deposit optical energy into metals, how this happens is poorly known. We investigated the plasmonic response of silver at the point where the dielectric response passes through zero and bulk plasmon is excited by light. We discovered that the plasmon excitation decays by exciting electrons from the Fermi level of a metal, which is contrary to what is believed in the plasmonic science community. This research has been performed in collaboration with Dr. Marcel Reutzel, who was a postdoctoral fellow working on this research at the University of Pittsburgh, and now has a faculty position at the University of Göttingen in Germany. Prof. Branko Gumhalter from the Institute of Physics in Zagreb contributed on the theory of plasmonic decay processes. Furthermore, we investigated the Floquet engineering of electronic bands in metals leading to multiphoton photoemission and above threshold photoemission. Finally, we demonstrated that it is possible to change the electronic structure of metals by application of optical fields. Our studies indicated that this happens on subfemtosecond time scale and could potentially be used in ultrafast information processing and quantum computation. Related document information

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hybrid Active-Passive Systems for Control of Aircraft Interior Noise

Previous work has demonstrated the large potential for hybrid active-passive systems for attenuating interior noise in aircraft fuselages. The main advantage of an active-passive system is, by utilizing the natural dynamics of the actuator system, the control actuator power and weight is markedly reduced and stability/robustness is enhanced. Three different active-passive approaches were studied in the past year. The first technique utilizes multiple tunable vibration absorbers (ATVA) for reducing narrow band sound radiated from panels and transmitted through fuselage structures. The focus is on reducing interior noise due to propeller or turbo fan harmonic excitation. Two types of tunable vibration absorbers were investigated; a solid state system based upon a piezoelectric mechanical exciter and an electromechanical system based upon a Motran shaker. Both of these systems utilize a mass-spring dynamic effect to maximize tile output force near resonance of the shaker system and so can also be used as vibration absorbers. The dynamic properties of the absorbers (i.e. resonance frequency) were modified using a feedback signal from an accelerometer mounted on the active mass, passed through a compensator and fed into the drive component of the shaker system (piezoelectric element or voice coil respectively). The feedback loop consisted of a two coefficient FIR filter, implemented on a DSP, where the input is acceleration of tile ATVA mass and the output is a force acting in parallel with the stiffness of the absorber. By separating the feedback signal into real and imaginary components, the effective natural frequency and damping of the ATVA can be altered independently. This approach gave control of the resonance frequencies while also allowing the simultaneous removal of damping from the ATVA, thus increasing the ease of controllability and effectiveness. In order to obtain a "tuned" vibration absorber the chosen resonant frequency was set to the excitation frequency. In order to minimize sound radiation a gradient descent algorithm was developed which globally adapted the resonance frequencies of multiple ATVA's while minimizing a cost based upon the radiated sound power or sound energy obtained from an array of microphones.

Fuller, Chris R.↗

A New Spectroscopic and Interferometric Study of the Young Stellar Object V645 Cyg

Aims. We present the results of high-resolution optical spectroscopy, low-resolution near-IR spectroscopy and near-infrared speckle interferometry of the massive young stellar object candidate V645 Cyg that were taken in order to refine its fundamental parameters and properties of its circumstellar envelope. Methods. Speckle interferometry in the H- and K-bands and an optical spectrum in the range 5200-6680 A with a spectral resolving power of R = 60000 were obtained at the 6 m telescope of the Russian Academy of Sciences. Another optical spectrum in the range 4300-10500 A with R = 79000 was obtained at the 3.6m CFHT. A low-resolution spectrum in the ranges 0.46-1.4 and 1.4-2.5 microns with a R approx. 800 and approx. 700, respectively, were obtained at the 3m Shain telescope of the Lick Observatory. Results. Using a new kinematic method based on non-linear modeling of the neutral hydrogen density profile in the direction toward the object, we suggest a new a distance D = 4.2+/-0.2 kpc. We also suggest a new estimate for the star's effective temperature, T(sub eff) approx. 25000 K. We have resolved the object in both H- and K-bands. Using a two-component ring fit, we derived a compact component size of 18 mas and 15 mas in the H- and K-band, respectively, which correspond to 37 and 33 AU at the new distance. Analysis of our and previously published data shows a approx. 2 mag drop of the near-infrared brightness of V645 Cyg in the beginning of the 1980 s. At the same time, the cometary nebular condensation N1 seems to fade in this wavelength range with respect to the N0 object, which represent the star with a nearly pole-on optically-thick disk and an optically-thin envelope. Conclusions. We conclude that V645 Cyg is a young massive main-sequence star, which recently emerged from its cocoon. and already passed the protostellar accretion stage. The presence of accretion is not necessary to account for the high observed luminosity of (2.6) x 10(exp 4) Solar Mass/yr. The receding part of a strong, mostly uniform outflow with a terminal velocity of approx.800 km/s is only blocked from view far from the star, where forbidden lines form. The near-infrared size of the source is consistent with the dust sublimation distance near this hot and luminous star and is the largest among young stellar objects observed interferometrically to-date.

Miroshinichenko, A. S.↗

The utility of Skylab photo-interpreted earth resources data in studies of marine geology and coastal processes in Puerto Rico and the Virgin Islands

The author has identified the following significant results. Three Skylab earth resources passes over Puerto Rico and St. Croix on 6 June and 30 November 1973 and 18 January 1974 resulted in color photography and multispectral photography and scanner imagery. Bathymetric and turbid water features are differentiable by use of the multispectral data. Photography allows mapping of coral reefs, offshore sand deposits, areas of coastal erosion, and patterns of sediment transport. Bottom sediment types could not be differentiated. Patterns of bottom dwelling biologic communities are well portrayed but are difficult to differentiate from bathymetric detail. Effluent discharges and oil slicks are readily detected and are differentiated from other phenomena by the persistence of their images into the longer wavelength multispectral bands.

Trumbull, J. V. A.↗

MARS 2020 Backshell Radiative Heating Measurement and Shock Tube Verification

In February 2021, the Perseverance rover was brought to the surface of Mars by the Mars 2020 mission. A feature of the Mars 2020 capsule was instrumentation to measure its entry, descent and landing (EDL) with the so-called Mars EDL Instrumentation 2 (MEDLI2) [1]. The MEDLI2 introduced, among other things, backshell instrumentation, including a broadband radiometer. The radiometer was mounted on the leeside of the vehicle next to thermocouple plugs and a heat flux gauge. The data returned by the leeside MEDLI2 heat flux gauge is largely analogous to that measured by the COMARS gauge flown on the ExoMars Schiaparelli [2] entry in that it is measuring heat flux in an area that is entirely dominated by radiative heating. The COMARS measurement provided excellent validation of backshell radiative heating models for Mars entry, albeit at a limited number of points [3]. The MEDLI2 heat flux gauge measurement effectively confirmed the quality of the prediction, extended over the full trajectory, as will be presented in this paper. The MEDLI2 radiometer,however, was blocked by ablation products and suffered a loss of half of its signal. The second backshell heat flux gauge installed on the windside of the vehicle was also well predicted, although the heating had both radiative and convective contributions. It was desired to reproduce the conditions of the Mars 2020 entry via ground testing in the Electric Arc Shock Tube (EAST) at NASA Ames. Tests to verify stagnation line heating were previously reported in EAST, confirming the presence of shock layer radiation as the major discrepancy in heatshield temperature modelling [4]. Therefore, tests for stagnation line heating were not repeated. Instead, the shock tube informed bias method [5, 6] was used to identify test conditions that may produce similarity to streamlines that pass around the backside of the vehicle and are responsible for the radiation observed at the two heat flux gauge locations. This method was used to identify a range of velocities and densities in the shock tube that are relevant for confirming the radiative environment encountered. This paper reports the results obtained in the 10 cm diameter EAST shock tube, corresponding to later trajectory points at ambient pressures of 1.1-2.0 Torr and velocities from 1.2-3.5 km/s. The test series employed two primary diagnostics: emission spectroscopy and tunable diode laser absorption spectroscopy (TDLAS). The emission spectroscopy performed broadband measurements of the radiative emission of the 4.3 and 2.7 m bands of CO2 at flight similar conditions, obtaining both spectral and spatial data corresponding to the relaxation behind the shock front. The TDLAS measured the absorption of several lines of CO and CO2 and obtains species number densities and temperatures as a function of time behind the shock front. This paper will review highlights of this test series and analyses of the emission and absorption data. While the datasets generally show good agreement with predictions, a few discrepancies and items for additional investigation are identified and will be discussed

Brett A Cruden↗

Evaluation of Airborne Visible/Infrared Imaging Spectrometer Data of the Mountain Pass, California carbonatite complex

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data of the Mountain Pass, California carbonatite complex were examined to evaluate the AVIRIS instrument performance and to explore alternative methods of data calibration. Although signal-to-noise estimates derived from the data indicated that the A, B, and C spectrometers generally met the original instrument design objectives, the S/N performance of the D spectrometer was below expectations. Signal-to-noise values of 20 to 1 or lower were typical of the D spectrometer and several detectors in the D spectrometer array were shown to have poor electronic stability. The AVIRIS data also exhibited periodic noise, and were occasionally subject to abrupt dark current offsets. Despite these limitations, a number of mineral absorption bands, including CO3, Al-OH, and unusual rare earth element bands, were observed for mine areas near the main carbonatite body. To discern these bands, two different calibration procedures were applied to remove atmospheric and solar components from the remote sensing data. The two procedures, referred to as the single spectrum and the flat field calibration methods gave distinctly different results. In principle, the single spectrum method should be more accurate; however, additional fieldwork is needed to rigorously determine the degree of calibration success.

Crowley, James↗

Instrumentation for Sensitive Gas Measurements

An improved instrument for optical absorption spectroscopy utilizes off-axis paths in an optical cavity in order to increase detection sensitivity while suppressing resonance effects. The instrument is well suited for use in either cavity ring-down spectroscopy (CRDS) [in which one pulses an incident light beam and measures the rate of decay of light in the cavity] or integrated cavity output spectroscopy (ICOS) [in which one uses a continuous-wave incident light beam and measures the power of light in the cavity as a function of wavelength]. Typically, in optical absorption spectroscopy, one seeks to measure absorption of a beam of light in a substance (usually a gas or liquid) in a sample cell. In CRDS or ICOS, the sample cell is placed in (or consists of) an optical cavity, so that one can utilize multiple reflections of the beam to increase the effective optical path length through the absorbing substance and thereby increase the sensitivity for measuring absorption. If an absorbing substance is not present in the optical cavity, one can utilize the multiple passes of the light beam to increase the sensitivity for measuring absorption and scattering by components of the optical cavity itself. It is desirable to suppress the effects of resonances in the cavity in order to make the spectral response of the cavity itself as nearly constant as possible over the entire wavelength range of interest. In the present instrument, the desired flattening of the spectral response is accomplished by utilizing an off-axis beam geometry to effectively decrease the frequency interval between longitudinal electromagnetic modes of the cavity, such that the resulting transmission spectrum of the cavity is nearly continuous: in other words, the cavity becomes a broad-band optical device.

OKeefe, Anthony↗

Identification of Acoustic Wave Signatures in the Ionosphere From Conventional Surface Explosions Using MF/HF Doppler Sounding

Here, we present an experiment to detect one ton TNT-equivalent chemical explosions using pulsed Doppler radar observations of isodensity layers in the ionospheric E region during two campaigns. The first campaign, conducted on 15 October 2019, produced potential detections of all three shots. The detections closely resemble the temporal and spectral properties predicted using the InfraGA ray tracing and weakly nonlinear waveform propagation model. Here the model predicts that within 6.5–7.25 min of each shot a waveform peaking between 0.9 and 0.4 Hz will impact the ionosphere at 100 km. As the waves pass through this region, they will imprint their signal on an isodensity layer, which is detectable using a Doppler radar operating at the plasma frequency of the isodensity. Within the time windows of each of the three shots in the first campaign, we detect enhanced wave activity peaking near 0.5 Hz. These waves were imprinted on the Doppler signal probing an isodensity layer at 2.785 MHz near 100 km altitude. Despite these detections, the method appears to be unreliable as none of the six shots from the second campaign, conducted on 10 July 2020 were detected. The observations from this campaign were characterized by an increased acoustic noise environment in the microbarom band and persistent scintillation on the radar returns. These effects obscured any detectable signal from these shots and the baseline noise was well above the detection levels of the first campaign.

47 OTHER INSTRUMENTATION↗

Process Anomaly Detection for Sparsely Labeled Events in Nuclear Power Plants

An essential aspect of online monitoring, subtle anomaly detection increases the detection lead time for equipment failure and enables a nuclear power plant (NPP) to mitigate unexpected partial or full outages, resulting in significant cost saving to the plant. Once an anomaly is detected by plant staff, its cause and severity are investigated. Because the vast majority of anomalies require some level of investigation, including some that require time-consuming examination, before they are passed over to the engineering organization for further analysis, plants are often equipped with tools to assist the staff in performing anomaly detection. Those tools operate as a black box and are often based on statistical methods that establish sensor correlations using preconfigured mathematical models and flag correlation deviations as anomalies. Due to the number of anomalies detected at a given NPP on a daily basis, a significant number of flagged anomalies usually await examination for days or weeks. A primary cause of this backlog is that the methods used by the tools generate many false positives. Though this is usually attributed to oversensitive model settings due to very narrow normal operation bands, it can also be associated with the model development being inadequate for the process being monitored, or with missing model inputs that could have explained misclassified positives. The performance of anomaly detection tools impacts their plant acceptance and utilization, especially when the effort to address false positives generated by the tool depletes the value or cost saved by using that tool. Thus, means to advance anomaly detection performance have been investigated by the Department of Energy’s Light Water Reactor Sustainability program. Previous and ongoing efforts have targeted unsupervised machine-learning (ML) methods, which do not require the labeling of any data fed into the ML model. By contrast, in supervised anomaly detection methods, every data point is labeled as either a normal or abnormal process condition, and the model is trained to replicate the classification process. Supervised methods usually outperform unsupervised methods, due to the added value in differentiating normal from anomalous states of the monitored process. An NPP’s corrective action program requires it to track and document, via a dedicated report, the resolution of any issues that occur within the plant. Once created, each report is reviewed by a plant screening committee, and several classifications and decisions are made. Recently, a collaborating NPP developed an artificial intelligence and ML-based classifier to categorize a condition report (CR) into classes that can serve to label the data as normal or anomalous. Applying CRs as labels represents a semi-supervised use case. Semi-supervised ML assumes that labels exist for some data points (i.e., labeled anomalies, in this case) but not for the rest. In this effort, semi-supervised ML methods were used to fuse data from CRs with anomaly detection methods in order to test the hypothesis that partially labeled anomalies would improve the accuracy of the anomaly detection methods. Specifically, two methods were used. The first is the deep Semi-supervised Anomaly Detection (deep SAD) method, which can handle labels ranging from fully unsupervised to fully supervised cases. The second is a newly designed ML method developed specifically for this effort and referred to as the high-order feature (HOF)-based method. To evaluate these two methods in controlled environments, synthetic data generators were developed and used. The first datasets used a spring-mass-damper (SMD) system simulator commonly found in mechanical engineering references. This was used to create two use cases: a one- and a three-mass system. Anomalies were introduced by changing the spring and damper coefficients while the system was actuated by random forces. The second datasets used the commercial Dymola-Modelica software to build a simplified nuclear reactor model. Anomalies were added in the form of corrupted sensor readings and/or control commands. The deep SAD method was tested using the SMD system, while the HOF method was tested using both datasets. Application of the deep SAD semi-supervised ML method demonstrated that labels can generate increased confidence in detecting true anomalies. This helped increase the number of true positives and decrease the number of false negatives—something that would aid in addressing the backlog of possible anomalies. Application of the HOF method demonstrated that labels can aid in down selecting from a candidate set of features to a more optimal subset in order to better differentiate between normal and anomalous conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗