Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Balloons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Rectal Dose-Volume Differences Using Proton Radiotherapy and a Rectal Balloon or Water Alone for the Treatment of Prostate Cancer

Purpose: To describe dose-volume values with the use of water alone vs. a rectal balloon (RB) for the treatment of prostate cancer with proton therapy. Materials and Methods: We analyzed 30 proton plans for 15 patients who underwent CT and MRI scans with an RB or water alone. Simulation was performed with a modified MRI endorectal coil and an RB with 100 mL of water or water alone. Doses of 78-82 gray equivalents were prescribed to the planning target volume. The two groups were compared for three structures: rectum, rectal wall (RW), and rectal wall 7 cm (RW7) at the level of the planning target volume. Results: Rectum and RW volumes radiated to low, intermediate, and high doses were small: rectum V10, 33.7%; V50, 17.3%; and V70, 10.2%; RW V10, 32.4%; V50, 20.4%; and V70, 14.6%. The RB effectively increased the rectal volume for all cases (139.8 {+-} 44.9 mL vs. 217.7 {+-} 32.2 mL (p < 0.001). The RB also decreased the volume of the rectum radiated to doses V10-V65 (p {<=} 0.05); RW for V10-V50; and RW7 for V10-V35. An absolute rectum V50 improvement >5% was seen for the RB in 5 of 15 cases, for a benefit of 9.2% {+-} 2.3% compared with 2.4% {+-} 1.3% for the remaining 10 cases (p < 0.001). Similar benefit was seen for the rectal wall. No benefit was seen for doses {>=}70 gray equivalents for the rectum, RW, or RW7. No benefit of {<=}1% was seen with an RB in 46% for the rectum V70 and in 40% for the rectal wall V70. Conclusions: Rectum and rectal wall doses with proton radiation were low whether using water or an RB. Selected patients will have a small but significant advantage with an RB; however, water alone was well tolerated and will be an alternative for most patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Interfraction Variations of MammoSite Balloon Applicator in High-Dose-Rate Brachytherapy of Partial Breast Irradiation

Purpose: To measure the interfraction changes of the MammoSite applicator and evaluate their dosimetric effect on target coverage and sparing of organs at risk. Methods and Materials: A retrospective evaluation of the data from 19 patients who received 10 fractions (34 Gy) of high-dose-rate partial breast irradiation was performed. A computed tomography-based treatment plan was generated for Fraction 1, and a computed tomography scan was acquired just before the delivery of each fraction to ensure a consistent shape of the balloon. The eccentricity, asymmetry, and planning target volume (PTV) for plan evaluation purposes (PTV{sub E}VAL), as well as trapped air gaps, were measured for all patients. Furthermore, 169 computed tomography-based treatment plans were retrospectively generated for Fractions 2-10. Interfraction dosimetric variations were evaluated using the %PTV{sub E}VAL coverage, target dose homogeneity index, target dose conformal index, and maximum doses to the organs at risks. Results: The average variation of eccentricity and asymmetry from Fraction 1 values of 3.5% and 1.1 mm was -0.4% {+-} 1.6% and -0.1 {+-} 0.6 mm. The average trapped air gap volume was dramatically reduced from before treatment (3.7 cm{sup 3}) to Fraction 1 (0.8 cm{sup 3}). The PTV{sub E}VAL volume change was insignificant. The average variation for the %PTV{sub E}VAL, target dose homogeneity, and target dose conformal index from Fraction 1 values of 94.7%, 0.64, and 0.85 was 0.15% {+-} 2.4%, -0.35 {+-} 2.4%, and -0.34 {+-} 4.9%, respectively. The average Fraction 1 maximum skin and ipsilateral lung dose of 3.2 Gy and 2.0 Gy varied by 0.08 {+-} 0.47 and -0.16 {+-} 0.29 Gy, respectively. Conclusion: The interfraction variations were patient specific and fraction dependent. Although the average interfraction dose variations for the target and organs at risk were not clinically significant, the maximum variations could be clinically significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improvements in Critical Dosimetric Endpoints Using the Contura Multilumen Balloon Breast Brachytherapy Catheter to Deliver Accelerated Partial Breast Irradiation: Preliminary Dosimetric Findings of a Phase IV Trial

Purpose: Dosimetric findings in patients treated with the Contura multilumen balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) on a multi-institutional Phase IV registry trial are presented. Methods and Materials: Computed tomography-based three-dimensional planning with dose optimization was performed. For the trial, new ideal dosimetric goals included (1) {>=}95% of the prescribed dose (PD) covering {>=}90% of the target volume, (2) a maximum skin dose {<=}125% of the PD, (3) maximum rib dose {<=}145% of the PD, and (4) the V150 {<=}50 cc and V200 {<=}10 cc. The ability to concurrently achieve these dosimetric goals using the Contura MLB was analyzed. Results: 144 cases were available for review. Using the MLB, all dosimetric criteria were met in 76% of cases. Evaluating dosimetric criteria individually, 92% and 89% of cases met skin and rib dose criteria, respectively. In 93% of cases, ideal target volume coverage goals were met, and in 99%, dose homogeneity criteria (V150 and V200) were satisfied. When skin thickness was {>=}5 mm to <7 mm, the median skin dose was limited to 120.1% of the PD, and when skin thickness was <5 mm, the median skin dose was 124.2%. When rib distance was <5 mm, median rib dose was reduced to 136.5% of the PD. When skin thickness was <7 mm and distance to rib was <5 mm, median skin and rib doses were jointly limited to 120.6% and 142.1% of the PD, respectively. Conclusion: The Contura MLB catheter provided the means of achieving the imposed higher standard of dosimetric goals in the majority of clinical scenarios encountered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate and Patient Intrafraction Motion: Impact on Treatment Time-Dependent Planning Margins for Patients With Endorectal Balloon

Purpose: To investigate intrafraction prostate and patient motion during different radiation therapy treatments as a function of treatment time; included were prostate patients with an endorectal balloon (ERB). Margins accounting for setup uncertainties and intrafraction motion were determined. Methods and Materials: The study included 17 patients undergoing prostate cancer radiation therapy. All patients received 3 fiducial gold markers implanted in the prostate and were then immobilized in the supine position with a knee support and treated with an ERB. Twelve patients with intermediate risk for pelvic lymph node metastases received intensity modulated radiation therapy (IMRT), and 5 patients at low risk received a 4-field box treatment. After setup based on skin marks, patients were imaged with a stereoscopic imaging system. If the marker displacement exceeded a 3-mm tolerance relative to planning computed tomography, patients were shifted and verification images were taken. All patients underwent additional imaging after treatment; IMRT patients also received additional imaging at halftime of treatment. Prostate and bone drifts were evaluated as a function of treatment time for more than 600 fractions, and margins were extracted. Results: Patient motion evaluated by bone match was strongly patient dependent but in general was smallest in the superior-inferior (SI) direction. Prostate drifts were less patient dependent, showing an increase with treatment time in the SI and anterior-posterior (AP) directions. In the lateral (LAT) direction, the prostate stayed rather stable. Mean treatment times were 5.5 minutes for 4-field box, 10 minutes for 5-field boost IMRT, and 15 minutes or more for 9-field boost and 9-field pelvic IMRT treatments. Margins resulted in 2.2 mm, 3.9 mm, and 4.3 mm for 4-field box; 3.7 mm, 2.6 mm, and 3.6 mm for 5-field boost IMRT; 2.3 mm, 3.9 mm, and 6.2 mm for 9-field boost IMRT; and 4.2 mm, 5.1 mm, and 6.6 mm for 9-field pelvic IMRT in the LAT, SI, and AP directions, respectively. Conclusion: Intrafraction prostate and patient displacement increased with treatment time, showing different behaviors for the single directions of movement. Repositioning of the patients during long treatments or shorter treatment times will be necessary to further reduce the treatment margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimal Benefit of an Endorectal Balloon for Prostate Immobilization as Verified by Daily Localization

We wanted to investigate whether using an endorectal balloon (ERB) in lieu of image guidance is reasonable. We compared daily prostate motion in 2 cohorts of patients with fiducial markers implanted in the prostate, one group with the ERB and the other without. Twenty-nine patients were treated using intensity-modulated radiation therapy: 14 with an ERB, and 15 without. All had fiducial markers placed in the prostate. We reviewed the daily displacements necessary to place the isocenter on the prostate as determined by portal imaging. In addition, we used the data to determine whether there is a change in prostate motion over the treatment course. The average prostate displacement for patients treated without an ERB was slightly greater than the average displacement for patients treated with the ERB. However, the difference observed with the ERB was not statistically significant (p > 0.05). The margins necessary to encompass the prostate 95% of the time for the patients treated without an ERB in the lateral, cranio/caudal, and anterior/posterior dimensions would be 4.8, 12.1, and 15.2 mm, respectively. When using the ERB, the margins necessary would be 4.1, 10.4, and 11 mm, respectively. Prostate motion in the anterior-posterior direction actually increased over the course of treatment in patients without an ERB. This increase was prevented by use of the ERB. Day-to-day variability of the position of the prostate is reduced in all dimensions with the water-filled ERB, but not significantly statistically. Use of the water-filled ERB did not obviate performing some form of image guidance daily.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tethered balloon system and High-Resolution Mass Spectrometry Reveal Increased Organonitrates Aloft Compared to the Ground Level

Atmospheric particles play critical roles in climate. However, significant knowledge gaps remain regarding the vertically resolved organic molecular-level composition of atmospheric particles due to aloft sampling challenges. To address this, we use a tethered balloon system at the Southern Great Plains Observatory and high-resolution mass spectrometry to, respectively, collect and characterize organic molecular formulas (MF) in the ground level and aloft (up to 750 m) samples. We show that organic MF uniquely detected aloft were dominated by organonitrates (139 MF; 54% of all uniquely detected aloft MF). Organonitrates that were uniquely detected aloft featured elevated O/C ratios (0.73 ± 0.23) compared to aloft organonitrates that were commonly observed at the ground level (0.63 ± 0.22). Unique aloft organic molecular composition was positively associated with increased cloud coverage, increased aloft relative humidity (~40% increase compared to ground level), and decreased vertical wind variance. Furthermore, 29% of extremely low volatility organic compounds in the aloft sample were truly unique to the aloft sample compared to the ground level, emphasizing potential oligomer formation at higher altitudes. Overall, this study highlights the importance of considering vertically resolved organic molecular composition (particularly for organonitrates) and hypothesizes that aqueous phase transformations and vertical wind variance may be key variables affecting the molecular composition of aloft organic aerosol.

54 ENVIRONMENTAL SCIENCES↗

Interplay between fluctuation driven toroidal axisymmetric flows and resistive ballooning mode turbulence

An interplay between fluctuation driven toroidal axisymmetric flows (convective cell modes) and resistive ballooning mode turbulence after the pedestal collapse is numerically studied by a four-field reduced MHD model in the BOUT++ framework. The strong flow shear suppresses the radial transport of pressure filaments, and the pressure profile in the pedestal region is partially recovered. As a result, a secondary instability is quasilinearly excited, which yields a secondary collapse. Here, the subsequent damped oscillation is also analyzed by phase diagram analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Close coupling of the peeling ballooning and external kink modes in high poloidal-beta discharges with strong shape and large pedestal width

In plasmas with strong shape and large pedestal width, like DIII-D high poloidal-beta discharges, the eigenvalue spectrum of the peeling ballooning mode (PBM) is shown to shift to the very low-n regime near one, where n is the toroidal mode number. This peeling-type eigenvalue spectrum has a further shift to n = 1, thus being smoothly connected to the n = 1 external kink mode (EKM), as the normalized beta (β N ) increases. Once this connection occurs, the mode takes a mixture form of the PBM and EKM with its mode structure varying from the PBM-like to the EKM-like one as β N increases. The mode stability also becomes sensitive to both the local pedestal gradient and global β N , thus allowing an anti-correlation between the two driving forces. Further, these results appear to provide a qualitative explanation of the two unexpected features observed in the DIII-D high poloidal-beta discharges, that is, the dominance of the n = 1 mode in the edge-localized-modes and the negative correlation between the pedestal height and the internal transport barrier strength.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-stage crash process in resistive drift ballooning mode driven ELM crash

We report a two-stage crash process in edge localized mode (ELM) driven by resistive drift-ballooning modes (RDBMs) numerically simulated in a full annular torus domain with a scale-separated four-field reduced MHD (RMHD) model using the BOUT++ framework. In the early nonlinear phase, the small first crash is triggered by linearly unstable RDBMs, and m/n=2/1 magnetic islands are nonlinearly excited by nonlinear coupling of RDBMs as well as their higher harmonics. Here, m is the poloidal mode number, n is the toroidal mode number, the q = 2 rational surface exists near the pressure gradient peak, and q is the safety factor. Simultaneously, middle-n RDBM turbulence develops but is poloidally localized around X-points of the magnetic islands, leading to the small energy loss. The second large crash occurs in the late nonlinear phase. Higher harmonics of m/n=2/1 magnetic islands well develop around the q = 2 surface via nonlinear coupling and make the magnetic field stochastic by magnetic island overlapping. Turbulence heat transport develops at X-points of higher harmonics of m/n=2/1 magnetic islands, resulting in the turbulence spreading in the poloidal direction. The large second crash is triggered when the turbulence covers the whole poloidal region so that the magnetic island generation and magnetic field stochastization before the large crash can be interpreted as ELM precursors. It is concluded that the ELM trigger is attributed to the turbulent spreading in the poloidal direction in synchronization with the magnetic field stochastization and the crash is driven by E × B convection rather than the conventional Rechester–Rosenbluth anomalous electron heat transport.

Seto, H. (ORCID:0000000259278643)↗

Kinetic-ballooning-bifurcation in tokamak pedestals across shaping and aspect-ratio

We use a new gyrokinetic threshold model to predict a bifurcation in tokamak pedestal width-height scalings that depends strongly on plasma shaping and aspect-ratio. The bifurcation arises from the first and second stability properties of kinetic-ballooning-modes that yields wide and narrow pedestal branches, expanding the space of accessible pedestal widths and heights. The wide branch offers potential for edge-localized-mode-free pedestals with high core pressure. For negative triangularity, low-aspect-ratio configurations are predicted to give steeper pedestals than conventional-aspect-ratio. Both wide and narrow branches have been attained in tokamak experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Global gyrokinetic simulations of kinetic-ballooning-mode turbulence in Wendelstein 7-X

We apply the global gyrokinetic code GENE-3D to perform kinetic-ballooning-mode (KBM) turbulence simulations in the Wendelstein 7-X (W7-X) stellarator using experimentally relevant parameters. In contrast to the flux-tube approach, we observe saturation of the turbulent fluctuations at finite amplitude. Analyzing the turbulent characteristics, we identify the presence of weakly driven KBM turbulence hybridizing with ion-temperature-gradient and trapped-electron-mode turbulence in the scenario under consideration, showing that it is possible that KBM activity can be driven in W7-X, opening up the path for studying this type of turbulence, which is highly relevant for future fusion power plants.

Electrostatics↗

Saturation of the kinetic ballooning instability due to the electron parallel nonlinearity

The electron parallel nonlinearity (EPN) is implemented in the gyrokinetic particle-in-cell turbulence code GEM [Y. Chen and S. E. Parker, J. Comp. Phys. 220, 839 (2007)]. Application to the Cyclone Base Case reveals a strong effect of EPN on the saturated heat transport above the kinetic ballooning mode (KBM) threshold. Evidence is provided to show that the strong effect is associated with the electron radial motion due to magnetic fluttering, which turns fine structures of the KBM eigenmode in radius into fine structures in velocity and increases the magnitude of the EPN term in the kinetic equation.

Gyrokinetic simulations↗

Peeling-ballooning modes in spherical tokamaks: Multi-branch instabilities and effects beyond ideal MHD

A number of important physics effects on the stability of relatively high-n (n is the toroidal mode number) peeling-ballooning modes (PBMs) are investigated based on an equilibrium reconstructed from a NSTX discharge, utilizing extended magnetohydrodynamic (MHD) eigenvalue solvers. For a given toroidal mode number n, multiple branches of instabilities are computed, with the total number of unstable branches roughly linearly scaling with n. Most of the unstable branches are located in the plasma core region, but edge-localized branches, i.e., PBMs, are also identified at higher n-numbers. For the single-fluid-wise most unstable PBM with n = 19⁠, stabilizing/destabilizing effects due to various physics beyond ideal MHD are systematically investigated. Plasma toroidal flow is found to be weakly stabilizing. Local flow shear is generally stabilizing as well, with the degree of stabilization depending on the initial growth rate (without flow shear) of the mode. The plasma resistivity can strongly destabilize the PBM within the single-fluid framework. Anisotropic thermal transport, strong parallel sound wave damping, as well as two-fluid effects are all stabilizing to the mode. In particular, diamagnetic stabilization (within the two-fluid model) is found to be very strong for this mode.

Linear stability analysis↗

Nonlinear magnetohydrodynamic modeling of ideal ballooning modes in high- β Wendelstein 7-X plasmas

We present nonlinear magnetohydrodynamic (MHD) simulations of high- β Wendelstein 7-X plasmas using the stellarator extension of the M3D- C 1 code, building on the recent work that shows benign saturation of ideal ballooning modes above the designed β limit in the standard configuration [Zhou et al., Phys. Rev. Lett. 133, 135102 (2024)]. First, we examine the results' sensitivity to the parallel thermal conductivity. It is found that while an increased parallel conductivity reduces the linear growth rate, the saturated pressure profile is barely affected. Second, we consider the dependence on the profile shape. It is shown that an equilibrium with a peaked pressure profile and lower β is subject to more significant change than a broad profile with higher β and a larger growth rate, suggesting that benign saturation, or nonlinear stability, is not guaranteed and not dictated by linear growth. Third, we study the influence of the magnetic configuration, with the equilibrium rotational transform varied by adjusting the planar coil current. With similar growth rates, similar magnitudes of profile change are found regardless of the presence of a low-order resonance, which implies that the saturation mechanism is not specific to a resonant or non-resonant mode. These results indicate that MHD stability should still be treated seriously in stellarator operation and design, for which nonlinear modeling using tools like M3D- C 1 can play an instrumental role.

Zhou, Yao [Shanghai Jiao Tong University (China)] ↗

Impact of impurities on peeling–ballooning modes and turbulence in tokamak plasmas

This study investigates the impact of various impurity species on peeling–ballooning (PB) modes and microturbulence in tokamak plasmas through the extension of traditional two-fluid and gyro-landau-fluid (GLF) models. By incorporating finite Larmor radius (FLR) effects, the analysis provides a comprehensive understanding of impurity-driven impact and its interaction with plasma turbulence. Depending on charge state and local plasma conditions, heavy impurities may exhibit gyro-radii larger than those of main ions, which are captured in the extended GLF model presented. Following the presentation of modified two-fluid equations incorporating impurity effects, we systematically analyze the distinctions between impurity and main ion dynamics and their resultant feedback mechanisms on plasma behavior. Derivation of the linear dispersion relation enables quantification of impurity-mediated modifications to: plasma vorticity, diamagnetic drift and gyroviscous effects, electron Hall physics, and FLR effects. BOUT++ – based linear simulations corroborate this formalism, demonstrating systematic stabilization of PB modes upon impurity seeding. And then operational implications for practical impurity control strategies in tokamak devices are proposed. The results underscore the necessity of impurity management to maintain stability and optimize plasma confinement, with specific focus on how FLR effects contribute to transport dynamics. This work paves the way for enhanced modeling and simulation efforts, supporting the development of strategies to control impurity-induced turbulence and improve overall reactor performance.

BOUT++ simulation↗

Plasmoid-mediated reconnection during nonlinear peeling–ballooning edge-localized modes

Abstract Plasmoid-mediated reconnection is investigated for nonlinear peeling–ballooning edge-localized modes (P-B ELMs). The formation of current sheets and the transition to 3D current sheet instability is demonstrated through fully nonlinear resistive MHD simulations of P-B ELMs in DIII-D discharges. Large-scale axisymmetric current sheets, as well as small-scale poloidally extended current sheets, are formed as the coherent P-B ELM filaments nonlinearly evolve. It is observed that, at high Lundquist numbers, these current sheets break during a reconnection burst, i.e. a secondary exponential growth of intermediate modes followed by relaxation due to the suppression of P-B drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decoupling of peeling and ballooning thresholds for pedestal stability and reduction in ELM frequency via enhanced turbulence with edge electron cyclotron heating in DIII-D

Abstract The edge localized mode (ELM) frequency ( f ELM ) decreased by 63% when electron cyclotron heating (ECH) deposition location is shifted from ρ = 0.4 to ρ = 0.8 in DIII-D discharges where the power ratio between neutral beam injection (NBI) and ECH ( P NBI / P ECH ) is kept at ∼1. The performance of the pedestal in the ECH heated case is compared with a pure NBI reference discharge while keeping the total input power constant. All these discharges are performed at balanced input torque conditions. Furthermore, in the pure NBI discharge a strong decoupling of the peeling–ballooning (PB) thresholds is observed. The PB decoupling is preserved when the ECH is deposited at ρ = 0.8 and P NBI / P ECH ∼ 1, while the thresholds manifest a closed stability boundary when the ECH is deposited at ρ = 0.4. The inter-ELM pedestal recovery time is considerably larger for the ECH at ρ = 0.8 case. Increased pedestal turbulence is observed in beam emission spectroscopy (BES), Doppler backscattering and magnetic diagnostics for the ECH at the ρ = 0.8 case. Strong growth of a TEM-like mode is observed in BES and the mode growth is correlated with the decrease in f ELM . In view of these observations, the increased pedestal turbulence seems to be the plausible reason behind the delayed pedestal recovery following an ELM event in the ECH at ρ = 0.8 case, and the preservation of PB decoupling through temperature pedestal profile widening. TRANSP interpretative simulations show that the ECH at the ρ = 0.8 case is more susceptible to ITG/TEM turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

BRIGHT POINTS IN THE QUIET SUN AS OBSERVED IN THE VISIBLE AND NEAR-UV BY THE BALLOON-BORNE OBSERVATORY SUNRISE

Bright points (BPs) are manifestations of small magnetic elements in the solar photosphere. Their brightness contrast not only gives insight into the thermal state of the photosphere (and chromosphere) in magnetic elements, but also plays an important role in modulating the solar total and spectral irradiance. Here, we report on simultaneous high-resolution imaging and spectropolarimetric observations of BPs using SUNRISE balloon-borne observatory data of the quiet Sun at the disk center. BP contrasts have been measured between 214 nm and 525 nm, including the first measurements at wavelengths below 388 nm. The histograms of the BP peak brightness show a clear trend toward broader contrast distributions and higher mean contrasts at shorter wavelengths. At 214 nm, we observe a peak brightness of up to five times the mean quiet-Sun value, the highest BP contrast so far observed. All BPs are associated with a magnetic signal, although in a number of cases it is surprisingly weak. Most of the BPs show only weak downflows, the mean value being 240 m s{sup -1}, but some display strong down- or upflows reaching a few km s{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗