Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Balloon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Impact of impurities on peeling–ballooning modes and turbulence in tokamak plasmas

This study investigates the impact of various impurity species on peeling–ballooning (PB) modes and microturbulence in tokamak plasmas through the extension of traditional two-fluid and gyro-landau-fluid (GLF) models. By incorporating finite Larmor radius (FLR) effects, the analysis provides a comprehensive understanding of impurity-driven impact and its interaction with plasma turbulence. Depending on charge state and local plasma conditions, heavy impurities may exhibit gyro-radii larger than those of main ions, which are captured in the extended GLF model presented. Following the presentation of modified two-fluid equations incorporating impurity effects, we systematically analyze the distinctions between impurity and main ion dynamics and their resultant feedback mechanisms on plasma behavior. Derivation of the linear dispersion relation enables quantification of impurity-mediated modifications to: plasma vorticity, diamagnetic drift and gyroviscous effects, electron Hall physics, and FLR effects. BOUT++ – based linear simulations corroborate this formalism, demonstrating systematic stabilization of PB modes upon impurity seeding. And then operational implications for practical impurity control strategies in tokamak devices are proposed. The results underscore the necessity of impurity management to maintain stability and optimize plasma confinement, with specific focus on how FLR effects contribute to transport dynamics. This work paves the way for enhanced modeling and simulation efforts, supporting the development of strategies to control impurity-induced turbulence and improve overall reactor performance.

BOUT++ simulation↗

Plasmoid-mediated reconnection during nonlinear peeling–ballooning edge-localized modes

Abstract Plasmoid-mediated reconnection is investigated for nonlinear peeling–ballooning edge-localized modes (P-B ELMs). The formation of current sheets and the transition to 3D current sheet instability is demonstrated through fully nonlinear resistive MHD simulations of P-B ELMs in DIII-D discharges. Large-scale axisymmetric current sheets, as well as small-scale poloidally extended current sheets, are formed as the coherent P-B ELM filaments nonlinearly evolve. It is observed that, at high Lundquist numbers, these current sheets break during a reconnection burst, i.e. a secondary exponential growth of intermediate modes followed by relaxation due to the suppression of P-B drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decoupling of peeling and ballooning thresholds for pedestal stability and reduction in ELM frequency via enhanced turbulence with edge electron cyclotron heating in DIII-D

Abstract The edge localized mode (ELM) frequency ( f ELM ) decreased by 63% when electron cyclotron heating (ECH) deposition location is shifted from ρ = 0.4 to ρ = 0.8 in DIII-D discharges where the power ratio between neutral beam injection (NBI) and ECH ( P NBI / P ECH ) is kept at ∼1. The performance of the pedestal in the ECH heated case is compared with a pure NBI reference discharge while keeping the total input power constant. All these discharges are performed at balanced input torque conditions. Furthermore, in the pure NBI discharge a strong decoupling of the peeling–ballooning (PB) thresholds is observed. The PB decoupling is preserved when the ECH is deposited at ρ = 0.8 and P NBI / P ECH ∼ 1, while the thresholds manifest a closed stability boundary when the ECH is deposited at ρ = 0.4. The inter-ELM pedestal recovery time is considerably larger for the ECH at ρ = 0.8 case. Increased pedestal turbulence is observed in beam emission spectroscopy (BES), Doppler backscattering and magnetic diagnostics for the ECH at the ρ = 0.8 case. Strong growth of a TEM-like mode is observed in BES and the mode growth is correlated with the decrease in f ELM . In view of these observations, the increased pedestal turbulence seems to be the plausible reason behind the delayed pedestal recovery following an ELM event in the ECH at ρ = 0.8 case, and the preservation of PB decoupling through temperature pedestal profile widening. TRANSP interpretative simulations show that the ECH at the ρ = 0.8 case is more susceptible to ITG/TEM turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

BRIGHT POINTS IN THE QUIET SUN AS OBSERVED IN THE VISIBLE AND NEAR-UV BY THE BALLOON-BORNE OBSERVATORY SUNRISE

Bright points (BPs) are manifestations of small magnetic elements in the solar photosphere. Their brightness contrast not only gives insight into the thermal state of the photosphere (and chromosphere) in magnetic elements, but also plays an important role in modulating the solar total and spectral irradiance. Here, we report on simultaneous high-resolution imaging and spectropolarimetric observations of BPs using SUNRISE balloon-borne observatory data of the quiet Sun at the disk center. BP contrasts have been measured between 214 nm and 525 nm, including the first measurements at wavelengths below 388 nm. The histograms of the BP peak brightness show a clear trend toward broader contrast distributions and higher mean contrasts at shorter wavelengths. At 214 nm, we observe a peak brightness of up to five times the mean quiet-Sun value, the highest BP contrast so far observed. All BPs are associated with a magnetic signal, although in a number of cases it is surprisingly weak. Most of the BPs show only weak downflows, the mean value being 240 m s{sup -1}, but some display strong down- or upflows reaching a few km s{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental Validation of a Kinetic Ballooning Mode in High-Performance High-Bootstrap Current Fraction Fusion Plasmas

We report the observation of a set of coherent high frequency electromagnetic fluctuations that leads to a turbulence induced self-regulating phenomenon in the DIII-D high bootstrap current fraction plasma. The fluctuations have frequency of 130~220kHz, the poloidal wave length and phase velocity are 16~30 m -1 and ~30 km/s, respectively in the outboard midplane with the estimated toroidal mode number n~5- 9. The fluctuations are located in the internal transport barrier (ITB) region at large radius and are experimentally validated to be kinetic ballooning modes (KBM). Furthermore, quasilinear estimation predicts the KBM to be able to drive experimental particle flux and non-negligible thermal flux, suggesting its significant role in regulating the ITB saturation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ASCENT: a balloon-borne hard x-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. Here, the isotope Ti44 is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard x-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called A SuperConducting ENergetic x-ray Telescope (ASCENT). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55-eV full-width half maximum energy resolution at 97 keV. This 8- to 16-fold improvement in energy resolution over NuSTAR will allow for high-resolution imaging and spectroscopy of the Ti44 emission. This will allow for a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as, What is the source of the neutron star kicks? What is the dominant production pathway for Ti44? Is the engine of Cas A unique?

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-280: Reconstructed Rectal Wall Dose Map-Based Verification of Rectal Dose Sparing Effect According to Rectum Definition Methods and Dose Perturbation by Air Cavity in Endo-Rectal Balloon

Purpose: Dosimetric effect and discrepancy according to the rectum definition methods and dose perturbation by air cavity in an endo-rectal balloon (ERB) were verified using rectal-wall (Rwall) dose maps considering systematic errors in dose optimization and calculation accuracy in intensity-modulated radiation treatment (IMRT) for prostate cancer patients. Methods: When the inflated ERB having average diameter of 4.5 cm and air volume of 100 cc is used for patient, Rwall doses were predicted by pencil-beam convolution (PBC), anisotropic analytic algorithm (AAA), and AcurosXB (AXB) with material assignment function. The errors of dose optimization and calculation by separating air cavity from the whole rectum (Rwhole) were verified with measured rectal doses. The Rwall doses affected by the dose perturbation of air cavity were evaluated using a featured rectal phantom allowing insert of rolled-up gafchromic films and glass rod detectors placed along the rectum perimeter. Inner and outer Rwall doses were verified with reconstructed predicted rectal wall dose maps. Dose errors and extent at dose levels were evaluated with estimated rectal toxicity. Results: While AXB showed insignificant difference of target dose coverage, Rwall doses underestimated by up to 20% in dose optimization for the Rwhole than Rwall at all dose range except for the maximum dose. As dose optimization for Rwall was applied, the Rwall doses presented dose error less than 3% between dose calculation algorithm except for overestimation of maximum rectal dose up to 5% in PBC. Dose optimization for Rwhole caused dose difference of Rwall especially at intermediate doses. Conclusion: Dose optimization for Rwall could be suggested for more accurate prediction of rectal wall dose prediction and dose perturbation effect by air cavity in IMRT for prostate cancer. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (MSIP) (Grant No. 200900420)

60 APPLIED LIFE SCIENCES↗

Topographic effects on reflected acoustic waves from the OSIRIS-REx reentry observed from stratospheric balloons

During long-distance sound propagation in planetary atmospheres, acoustic waves may reflect off the air/surface interface one or more times. For low sound frequencies and flat interfaces, the incident and reflected wave tend to be nearly identical. However, this may not be the case when the downgoing acoustic wave encounters topography. Here, we describe a set of direct and reflected acoustic signals recorded on free-flying balloons during the hypersonic entry of the OSIRIS-REx sample return capsule (SRC). In two of the three cases presented here, an impulsive reflected arrival similar in form to the direct sonic boom of the SRC is observed, followed by a diffuse coda. In contrast, one of the floating stations lacked an impulsive reflection entirely, with only the coda present. We use full waveform modeling to show how reflection in the presence of complex topography can explain coda seen in all three examples as well as the lack of impulsive arrival on the third. Our results indicate that the complex signals often observed in long range acoustic propagation could be due, in part, to interactions with topography during transmission.

Lees, Jonathan M. [University of North Carolina, C↗

Geophysical and Planetary Acoustics on Balloons

Natural events and human activity often generate acoustic waves capable of traveling tens to tens of thousands of kilometers across the globe. Ground-based acoustic sensors are limited to dry land and often suffer from wind noise. In contrast, balloon borne acoustic sensors can cross oceans, polar ice caps, and other inhospitable areas, greatly expanding sensor coverage. Since they move with the mean wind speed, their background noise levels are exceptionally low. In the last six years, such sensors have recorded sounds from colliding ocean waves, surface and buried chemical explosions, thunder, wind/mountain interactions, wind turbines, aircraft, and possibly meteors and the aurora. These results have led to new insights on acoustic heating of the upper atmosphere, the detectability of underground explosions, and directional sound fields generated by ocean waves.

47 OTHER INSTRUMENTATION↗

Development of a Balloon-Borne Barge-Mounted Wind Measurement Platform

Atmospheric measurements are collected from anemometer modules (cup-version pictured) that are attached to a tether line between a balloon and barge at user-specified intervals. Each module samples wind speed, wind direction, pressure, temperature, relative humidity, and GPS-derived latitude, longitude, and altitude in situ at 1 Hz or faster and transmits the data wirelessly to a base station on a barge. Fiber-optic based distributed temperature sensing (DTS) also provides an almost continuous atmospheric temperature profile with a vertical spatial resolution of 0.25 m.

47 OTHER INSTRUMENTATION↗

Cloud Droplet Measurement System for the ARM Tethered Balloon System (TBS) Field Campaign Report

The Mesa Photonics' cloud droplet measurement system (CDMS) performs in situ measurement of droplet size distribution and droplet number density in clouds. These characteristics are important cloud microphysical properties that are critical input parameters for atmospheric models and are also useful for proper calibration and validation of performance of other atmospheric measurement instrumentation. This small campaign was the first project (out of two) that involved integration of the CDMS into the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s tethered balloon system (TBS) and its initial testing at the ARM Southern Great Plains (SGP) atmospheric observatory. The follow-up campaign (AFC07016) involved testing of the CDMS under relevant conditions at the third ARM Mobile Facility (AMF3) at Oliktok Point, Alaska and making in situ measurements in clouds. The goal of this small field campaign was to deploy the CDMS on the ARM TBS, demonstrate its integrity and compatibility with the TBS, and test the wireless telecommunication system in preparation for subsequent in-cloud measurements at ARM’s North Slope of Alaska (NSA) observatory at Utqiagvik (formerly Barrow). The specific technical objectives included: (1) Integration of the Mesa Photonics' CDMS into the ARM TBS, (2) testing of the wireless telecommunication system of the CDMS, (3) evaluating the data acquisition software and image processing algorithms especially under high-background-illumination conditions, and (4) testing the ruggedness of the instrument's optical alignment and other performance characteristics. All objectives have been successfully met. The mounting hardware was designed and built mostly at Sandia National Laboratories (SNL), which allowed reliable mounting of the CDMS on the TBS and co-locating the CDMS with other instruments. The field tests were performed by the principal investigator (PI) in collaboration with the TBS operational crew led by D. Dexheimer. The field testing demonstrated good compatibility of the CDMS with the TBS. During the TBS flights, the crew did not experience any operational issues with the CDMS. The instrument demonstrated reliable operational characteristics, including sufficient battery life and good thermal management. The wireless telecommunication system has been successfully tested at TBS flight altitudes of up to 1000 m. During all flights, the CDMS raw data were wirelessly transmitted to the ground station and processed in real time. The ruggedness of the instrument's optical alignment was evaluated by performing calibration of the CDMS (using Mesa Photonics' fixed-size monodisperse droplet generator) before and after the campaign. The calibration was stable within the instrument's measurement precision. In summary, the campaign demonstrated good compatibility of the Mesa Photonics' CDMS with the ARM TBS. The flight tests confirmed the mechanical integrity of the CDMS and stability of its optical layout, as well as reliability of the wireless telecommunication system. Successful completion of this campaign provided a solid basis for the next campaign (AFC07016, November 2020), that involved testing of the CDMS during in-cloud TBS flights at AMF3 at Oliktok Point.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity Effects of Hollow Glass Micro-Balloon Doping on RDX-Based Explosives

Sensitivity to initiation is an important characteristic of high explosives. Many chemical and physical properties are fine-tuned to deliver an energetic material that behaves according to the user’s specifications exactly. In some cases, it is advantageous to study the effects that non energetic additives have on the performance of an explosive material. Following on the promising results obtained in other experiments, a study is conducted on the effects of hollow glass micro-balloons (bubbles, spheres), or HGMB, on a material’s sensitivity. Threshold test data is compared between several formulations of explosives. The control formulation is an RDX-based explosive with a non-energetic binder, and the test formulations are identical in composition, but with the addition of HGMB, up to 6% by volume. Safety testing of the new HGMB-doped explosive formulations is conducted to ensure they can be produced and handled safely prior to intentional detonation. This experiment utilizes an attenuation card of varying thicknesses between the initiator and the test article to attenuate the shock imparted, and a witness plate is analyzed for each test article to determine a GO or NO GO result. The data collected and the conclusions of this study affect how additives like HGMB are utilized in future explosive sensitivity threshold experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tethered Balloon System merged (TBSmerged) Value-Added Product Report

TBSmerged integrates data from instruments flown on ARM’s Tethered Balloon System missions that collect in situ measurements of temperature, humidity, wind speed, wind direction, and aerosol properties with estimates of cloud base and boundary layer height from a surface-based ceilometer to improve the ease of use of TBS datasets. TBSmergedincloud includes supercooled liquid water content (tbsslwc) measurements collected within the cloud.

54 ENVIRONMENTAL SCIENCES↗

North Slope Alaska and Tethered Balloon Systems: ARM Facilities Monthly Status Update

In support of the DOE Office of Science, Sandia National Labs is one of nine national laboratories which oversees the Atmospheric Radiation Measurement (ARM) Program. The Sandia ARM team has an obligation to fulfill its mission to provide the nation with data to improve the understanding of climate processes and the representation of those processes in climate models. Sandia’s ARM team’s ability to provide detailed and accurate descriptions of the Earth’s atmosphere in diverse climate regimes assists the DOE in development of sustainable solutions to the nation’s energy and environmental challenges. Sandia Labs manages ARM atmospheric facilities along the North Slope of Alaska (NSA) at Utqiagvik as well as the Tethered Balloon System (TBS). Activities conducted at NSA and with the TBS aide in data collection for the ARM data archive. An overview of these activities for the month of December follows.

54 ENVIRONMENTAL SCIENCES↗

Tethered Balloon System Ozone Profiles during CoURAGE Summer Intensive Operational Period Field Campaign Report

During the summer IOP, the small ARM field campaign CRGTBSO3 collected measurements to gain an improved understanding of differences between the atmospheric composition in and just above the marine layer at the CoURAGE TBS site near the eastern shore of Chesapeake Bay. CRGTBSO3 included guest instrumentation with ozone (O 3 ) profile measurements on the TBS and surface O3 and meteorological measurements at the TBS site. An En-Sci 2Z electrochemical cell (ECC) ozonesonde (Komhyr 1969, 1986, Witte et al. 2018) was included on the TBS. The ozonesonde was connected to an InterMet iMet-4RSB radiosonde, and the overall data collected included vertical profiles of ozone, relative humidity, temperature, pressure, and altitude. The CRGTBSO3 iMet-4 radiosonde data is identical to that of the iMet in the Tethered Balloon System Merged Data Product (TBSMERGED; Gaustad and Dexheimer 2025). The TBSMERGED data product also includes meteorological data from a different sensor, the iMet XQ2. In some cases, the iMet XQ2 relative humidity (RH) data may be more accurate than the iMet-4, such as for some instances when the iMet-4 RH data stays at 100% for an extended period throughout a profile.

54 ENVIRONMENTAL SCIENCES↗

MEASUREMENTS OF COSMIC-RAY PROTON AND HELIUM SPECTRA FROM THE BESS-POLAR LONG-DURATION BALLOON FLIGHTS OVER ANTARCTICA

The BESS-Polar Collaboration measured the energy spectra of cosmic-ray protons and helium during two long-duration balloon flights over Antarctica in 2004 December and 2007 December at substantially different levels of solar modulation. Proton and helium spectra probe the origin and propagation history of cosmic rays in the galaxy, and are essential to calculations of the expected spectra of cosmic-ray antiprotons, positrons, and electrons from interactions of primary cosmic-ray nuclei with the interstellar gas, and to calculations of atmospheric muons and neutrinos. We report absolute spectra at the top of the atmosphere for cosmic-ray protons in the kinetic energy range 0.2–160 GeV and helium nuclei in the range 0.15–80 GeV/nucleon. The corresponding magnetic-rigidity ranges are 0.6–160 GV for protons and 1.1–160 GV for helium. These spectra are compared to measurements from previous BESS flights and from ATIC-2, PAMELA, and AMS-02. We also report the ratio of the proton and helium fluxes from 1.1 to 160 GV and compare this to the ratios from PAMELA and AMS-02.

79 ASTRONOMY AND ASTROPHYSICS↗