Technique, Complication, and Long-Term Outcome for Endovascular Treatment of Iliac Artery Occlusion

The aim of this study was to report technical details, procedure-related complications, and results of endovascular treatment in chronic iliac artery occlusion. Between 2001 and 2008, endovascular treatments of 127 chronic iliac artery occlusions in 118 patients (8 women and 110 men; mean age, 59 years) were retrospectively reviewed. The study was based on Ad Hoc Committee on Reporting Standards (Society for Vascular Surgery/International Society for Cardiovascular Surgery Standards). All occlusions were treated with stent placement with or without preliminary balloon angioplasty. Kaplan-Meier estimators were used to determine patency rates. Univariate and multivariate analyses were performed to determine variables affecting successful recanalization, major complications, early stent thrombosis ({<=}30 days), and primary and secondary patency rates. Initial technical success was achieved in 117 (92%) procedures. Successful recanalization was obtained by antegrade approach in 69 of 77 (90%) procedures and by retrograde approach in 52 of 105 (50%) procedures (p < 0.001). Complications were encountered in 28 (24%) patients [minor in 7 patients (6%) and major in 22 patients (19%)]. One death occurred in the operative period secondary to iliac artery rupture. Early stent thrombosis was seen in eight (7%) patients. Presence of critical limb ischemia (p = 0.03), subintimal recanalization (p = 0.03), and major complication (p = 0.02) were the independent predictors of early stent thrombosis on multivariate analysis. Primary and secondary patency rates at 5 years were 63 and 93%, respectively. Presence of critical limb ischemia, TASC type C iliac lesions, combined occlusions of both common and external iliac arteries, and major complications were associated with decreased patency rates on univariate analysis, whereas these factors were not independent predictors of stent patency on multivariate analysis. In conclusion, endovascular treatment of iliac artery occlusion has a high technical success rate with favorable long-term patency rate. Success of recanalization increases with use of the antegrade approach and with the presence of a stump of artery before the occlusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Massive Pulmonary Embolism: Percutaneous Emergency Treatment Using an Aspirex Thrombectomy Catheter

Massive pulmonary embolism (PE) is a life-threatening condition with a high early mortality rate caused by acute right ventricular failure and cardiogenic shock. A 51-year-old woman with a massive PE and contraindication for thrombolytic therapy was treated with percutaneous mechanical thrombectomy using an Aspirex 11F catheter (Straub Medical AG, Wangs, Switzerland). The procedure was successfully performed and showed a good immediate angiographic result. The patient made a full recovery from the acute episode and was discharged on heparin treatment. Our case report indicates that in patients with contraindications to systemic thrombolysis, catheter thrombectomy may constitute a life-saving intervention for massive PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Short-Term Effects of Transjugular Intrahepatic Shunt on Cardiac Function Assessed by Cardiac MRI: Preliminary Results

The purpose of this study was to assess short-term effects of transjugular intrahepatic shunt (TIPS) on cardiac function with cardiac magnetic resonance imaging (MRI) in patients with liver cirrhosis. Eleven patients (six males and five females) with intractable esophageal varices or refractory ascites were imaged with MRI at 1.5 T prior to, within 24 h after, and 4-6 months after TIPS creation (n = 5). Invasive pressures were registered during TIPS creation. MRI consisted of a stack of contiguous slices as well as phase contrast images at all four valve planes and perpendicular to the portal vein. Imaging data were analyzed through time-volume curves and first derivatives. The portoatrial pressure gradient decreased from 19.8 {+-} 2.3 to 6.6 {+-} 2.3, accompanied by a nearly two fold increase in central pressures and pulmonary capillary wedge pressure immediately after TIPS creation. Left and right end diastolic volumes and stroke volumes increased by 11, 13, and 24%, respectively (p < 0.001), but dropped back to baseline at follow-up. End systolic volumes remained unchanged. E/A ratios remained within normal range. During follow-up the left ventricular mass was larger than baseline values in all patients, with an average increase of 7.9 g (p < 0.001). In conclusion, the increased volume load shunted to the heart after TIPS creation transiently exceeded the preload reserve of the right and left ventricle, leading to significantly increased pulmonary wedge pressures and persistent enlargement of the left and right atria. Normalization of cardiac dimensions was observed after months together with mild left ventricular hypertrophy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Resolution of Hepatic Encephalopathy Following Hepatic Artery Embolization in a Patient with Well-Differentiated Neuroendocrine Tumor Metastatic to the Liver

Hepatic encephalopathy is considered a contraindication to hepatic artery embolization. We describe a patient with a well-differentiated neuroendocrine tumor metastatic to the liver with refractory hepatic encephalopathy and normal liver function tests. The encephalopathy was refractory to standard medical therapy with lactulose. The patient's mental status returned to baseline after three hepatic artery embolization procedures. Arteriography and ultrasound imaging before and after embolization suggest that the encephalopathy was due to arterioportal shunting causing hepatofugal portal venous flow and portosystemic shunting. In patients with a primary or metastatic well-differentiated neuroendocrine tumor whose refractory hepatic encephalopathy is due to portosystemic shunting (rather than global hepatic dysfunction secondary to tumor burden), hepatic artery embolization can be performed safely and effectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Intraluminal Recanalization of Long, Chronic Superficial Femoral and Popliteal Occlusions Using the Frontrunner XP CTO Device: A Single-Center Experience

The purpose of this study was to examine the safety and efficacy of the Frontrunner XP CTO (chronic total occlusion) Catheter (Cordis) for recanalization of long femoropopliteal artery occlusions. A Frontrunner catheter was used to treat 26 CTOs in SFA after guidewire failure (68.3 {+-} 8.8 years). Sixty-seven percent of patients had severe claudication. Critical lower limb ischemia with rest pain or minor tissue loss was present in three and eight patients, respectively. All the lesions were considered complex (TASC B, C, and D); 68% of the lesions were heavily calcified. The mean lesion length was 17.6 cm (range, 10-42 cm). The initial attempt to cross the occlusion with the CTO guidewire V18 was unsuccessful in 26 of 76 limbs (34.26%). A secondary attempt using the Frontrunner catheter (crossover approach, 27%; antegrade, 73%) performed in all 26 failed cases was successful in 17 limbs (65.38%), increasing the technical success rate to 88.12%. The main reasons for failure with the Frontrunner were inability to cross the lesion due to heavy calcification (six of nine) and inability to re-enter the true lumen after subintimal passage of the occluded segment (three of nine). The mean fluoroscopy time was 22.9 min. Minor complications included one distal extension of the dissection with involvement of the first popliteal segment and one perforation in the occluded segment. No major complications were seen. In conclusion, recanalization with the Frontrunner CTO catheter is a simple and safe method with a high technical success rate in the endovascular treatment of long superficial femoral artery occlusions and should be an alternative method after guidewire failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnosis of Popliteal Venous Entrapment Syndrome by Magnetic Resonance Imaging Using Blood-Pool Contrast Agents

Popliteal vascular entrapment syndrome is caused by aberrations or hypertrophy of the gastrocnemius muscles, which compress the neurovascular structures of the popliteal fossa, leading to symptoms of vascular and degeneration as well as aneurysm formation. Imaging of popliteal vascular entrapment may be performed with ultrasound, magnetic resonance imaging (MRI), computed tomography angiography, and conventional angiography. The use of blood-pool contrast agents in MRI when popliteal vascular entrapment is suspected offers the possibility to perform vascular imaging with first-pass magnetic resonance angiographic, high-resolution, steady-state imaging and allows functional tests all within one examination with a single dose of contrast agent. We present imaging findings in a case of symptomatic popliteal vein entrapment diagnosed by the use of blood pool contrast-enhanced MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Retrospective Comparative Study of Tunneled Haemodialysis Catheters Inserted Through Occluded or Collateral Veins Versus Conventional Methods

Tunneled hemodialysis catheters become essential in dialysis access when there is no possibility of using a functioning arteriovenous fistula. Collateral or occluded veins visible on ultrasound are used for puncture and passage of catheters into the central venous system. Chronically occluded veins are crossed with guidewires to allow dilatation and subsequent passage of hemodialysis catheters. We performed a retrospective analysis of patient demographics, comorbidities, procedural complications, functional survival, performance, and history of previous vascular access. The study group was compared with two control groups in which dialysis catheters were inserted either by radiologists in the interventional suite or by clinicians on the wards. Nineteen patients from the study group were compared with same number of patients in both control groups. The mean age of the study group was higher compared with the control groups. There was no significant difference in mean functional survival, infection rates, dialysis pump speeds in the first 2 weeks, and procedural complications between the study group and the controls. The study group had a significantly higher number of previous vascular access interventions, longer dialysis careers, and more comorbidities. Tunneled dialysis catheter placement by way of collateral or occluded veins appears safe and effective. These techniques give the operator further options when faced with patients possessing challenging vascular access. Indeed, there may be a case for preferential use of these veins to keep patent central veins in reserve.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vertebral Arteriovenous Fistula Presenting as Cervical Myelopathy: A Rapid Recovery with Balloon Embolization

A 24-year-old male presented with progressive cervical myelopathy of 2 months' duration. Magnetic resonance imaging of the cervical spine and angiography revealed a large arteriovenous fistula arising from the left vertebral artery. The present case highlights the clinical features and dramatic recovery following endovascular balloon occlusion of a giant cervical arteriovenous fistula.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Endovascular Repair of a Celiac Trunk Aneurysm Using Celiac-Splenic Stent Graft and Hepatic Artery Embolization

Celiac trunk aneurysms are rare and usually asymptomatic lesions. However, treatment is generally warranted to avoid catastrophic rupture. We report a case of a 70-year-old man who sought care for a celiac trunk aneurysm close to the hepatosplenic bifurcation managed endovascularly by using a combined treatment of celiac-splenic stent-graft implantation and hepatic artery embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adrenal Venous Sampling: Where Is the Aldosterone Disappearing to?

Adrenal venous sampling (AVS) is generally considered to be the gold standard in distinguishing unilateral and bilateral aldosterone hypersecretion in primary hyperaldosteronism. However, during AVS, we noticed a considerable variability in aldosterone concentrations among samples thought to have come from the right adrenal glands. Some aldosterone concentrations in these samples were even lower than in samples from the inferior vena cava. We hypothesized that the samples with low aldosterone levels were unintentionally taken not from the right adrenal gland, but from hepatic veins. Therefore, we sought to analyze the impact of unintentional cannulation of hepatic veins on AVS. Thirty consecutive patients referred for AVS were enrolled. Hepatic vein sampling was implemented in our standardized AVS protocol. The data were collected and analyzed prospectively. AVS was successful in 27 patients (90%), and hepatic vein cannulation was successful in all procedures performed. Cortisol concentrations were not significantly different between the hepatic vein and inferior vena cava samples, but aldosterone concentrations from hepatic venous blood (median, 17 pmol/l; range, 40-860 pmol/l) were markedly lower than in samples from the inferior vena cava (median, 860 pmol/l; range, 460-4510 pmol/l). The observed difference was statistically significant (P < 0.001). Aldosterone concentrations in the hepatic veins are significantly lower than in venous blood taken from the inferior vena cava. This finding is important for AVS because hepatic veins can easily be mistaken for adrenal veins as a result of their close anatomic proximity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of a Peripherally Inserted Central Catheter as a Conduit for Central Venous Access Across Thrombosed Great Veins

This report describes a technique of inserting an implantable venous access port (portacath) through a thrombosed and occluded vein employing a pre-existing peripherally inserted central catheter (PICC) as the route of access. The PICC was used as a conduit for venous access in a way that has not been described previously in the literature. This procedure was performed in a young patient with cystic fibrosis in an effort to prevent the use of his virgin contralateral veins, which might be used in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Endovascular Treatment of Sac Rupture for Type IIIa Endoleak in Thoracic Aortic Aneurysm Previously Excluded with Endovascular Repair

Elective endovascular treatment of thoracic aortic pathology has been applied in a variety of conditions. The complications of thoracic aortic stenting are also well recognized. Endoleak after endovascular repair of thoracic aortic aneurysms is the most frequent complication; among them, type III is the least frequent. Endovascular treatment of type III endoleak is generally performed under elective conditions; less frequently, in emergency. We report a successful emergency endovascular management of post-thoracic endovascular repair for thoracic aortic aneurysm rupture due to type IIIa endoleak.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Cone-Shaped Aortic Valve Prosthesis for Orthotopic Position: An Experimental Study in Swine

The aim of this experimental study was to evaluate a newly designed cone-shaped aortic valve prosthesis (CAVP) for one-step transcatheter placement in an orthotopic position. The study was conducted in 15 swine using either the transcarotid (11 animals) or the transfemoral (4 animals) artery approach. A 12- or 13-Fr sheath was inserted via arterial cutdown. The CAVP was deployed under fluoroscopic control and its struts, by design, induced significant native valve insufficiency. CAVP function was evaluated by aortography and aortic pressure curve tracing. In 11 of 15 swine the CAVP was properly deployed and functioned well throughout the scheduled period of 2-3 h. In three swine the CAVPs were placed lower than intended, however, they were functional even in the left ventricular outflow tract position. One swine expired due to inadvertent low CAVP placement that caused both aortic regurgitation and immobilization of the anterior mitral valve leaflet by the valve struts. We conclude that this design of CAVP is relatively easy to deploy, works well throughout a short time period (2-3 h), and, moreover, seems to be reliable even in a lower-than-orthotopic position (e.g., infra-annulary space). Longer-term studies are needed for its further evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostatic Artery Embolization as a Primary Treatment for Benign Prostatic Hyperplasia: Preliminary Results in Two Patients

Symptomatic benign prostatic hyperplasia (BPH) typically occurs in the sixth and seventh decades, and the most frequent obstructive urinary symptoms are hesitancy, decreased urinary stream, sensation of incomplete emptying, nocturia, frequency, and urgency. Various medications, specifically 5-{alpha}-reductase inhibitors and selective {alpha}-blockers, can decrease the severity of the symptoms secondary to BPH, but prostatectomy is still considered to be the traditional method of management. We report the preliminary results for two patients with acute urinary retention due to BPH, successfully treated by prostate artery embolization (PAE). The patients were investigated using the International Prostate Symptom Score, by digital rectal examination, urodynamic testing, prostate biopsy, transrectal ultrasound (US), and magnetic resonance imaging (MRI). Uroflowmetry and postvoid residual urine volume complemented the investigation at 30, 90, and 180 days after PAE. The procedure was performed under local anesthesia; embolization of the prostate arteries was performed with a microcatheter and 300- to 500-{mu}m microspheres using complete stasis as the end point. One patient was subjected to bilateral PAE and the other to unilateral PAE; they urinated spontaneously after removal of the urethral catheter, 15 and 10 days after the procedure, respectively. At 6-month follow-up, US and MRI revealed a prostate reduction of 39.7% and 47.8%, respectively, for the bilateral PAE and 25.5 and 27.8%, respectively, for the patient submitted to unilateral PAE. The early results, at 6-month follow-up, for the two patients with BPH show a promising potential alternative for treatment with PAE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

One Year Clinical Outcomes of Renal Artery Stenting: The Results of ODORI Registry

The safety, efficacy and long term clinical benefits of renal artery revascularization by stenting are still a matter of debate. The aim of our study was to define the safety and efficacy of renal artery stenting with the Tsunami peripheral stent (Terumo Corporation, Tokyo, Japan). The ODORI was a prospective, multicentre registry which enrolled 251 consecutive patients, (276 renal arteries) in 36 centres across Europe. The primary endpoint was acute procedural success defined as <30% residual stenosis after stent placement. Secondary endpoints included major adverse events, blood pressure control, serum creatinine level, and target lesion revascularization (TLR) at 6 and 12 months. Patients were 70 {+-} 10 years old, 59% were male, 33% had diabetes, and 96% hypertension. The main indications for renal stent implantation were hypertension in 83% and renal salvage in 39%. Direct stent implantation was performed in 76% of the cases. Acute success rate was 100% with residual stenosis of 2.5 {+-} 5.4%. Systolic/diastolic blood pressure decreased from a mean of 171/89 at baseline to 142/78 mmHg at 6 months (p < 0.0001 vs. baseline), and 141/80 mmHg at 12 months (p < 0.0001 vs. baseline). Mean serum creatinine concentration did not change significantly in the total population. However, there was significant improvement in the highest tercile (from 283 {mu}mol/l at baseline to 205 and 209 {mu}mol/l at 6 and 12 months respectively). At 12-months, rates of restenosis and TLR were 6.6 and 0.8% respectively. The 12 month cumulative rate of all major clinical adverse events was 6.4% while the rate of device or procedure related events was 2.4%. In hypertensive patients with atherosclerotic renal artery stenosis Tsunami peripheral balloon-expandable stent provides a safe revascularization strategy, with a potential beneficial impact on hypertension control and renal function in the highest risk patients.