Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BETA DECAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Self-Correction of Lanthanum-Cerium Halide Gamma Spectra (pre-print)

Lanthanum-cerium halide detectors generally exhibit superior energy resolutions for gamma radiation detection compared with conventional sodium iodide detectors. However, they are also subject to self-activities due to lanthanum-138 decay and contamination due to beta decay in the low-energy region and alpha decay in the high-energy region. The detector’s self-activity and crystal contamination jointly contribute a significant amount of uncertainties to the gamma spectral measurement and affect the precision of the nuclide identification process. This paper demonstrates a self-correction procedure for self-activity and contamination reduction from spectra collected by lanthanum-cerium halide detectors. It can be implemented as an automatic self-correction module for the future gamma radiation detector made of lanthanum-cerium halide crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low radioactivity CaF{sub 2} scintillator crystals for CANDLES

CANDLES is the project to search for neutrinoless double beta (0{nu}{beta}{beta}) decay of {sup 48}Ca by using CaF{sub 2} scintillators. The observation of 0{nu}{beta}{beta} decay will prove the existence of massive Majorana neutrinos. Expected performances and current status of the CANDLES system are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and reduction of low-level radon background in the KATRIN experiment

The KArlsruhe TRItium Neutrino (KATRIN) experiment is a next generation, model independent, large scale experiment to determine the mass of the electron anti-neutrino by investigating the kinematics of tritium beta decay with a sensitivity of 200 meV/c{sup 2}. The measurement setup consists of a high luminosity windowless gaseous molecular tritium source (WGTS), a differential and cryogenic pumped electron transport and tritium retention section, a tandem spectrometer section (pre-spectrometer and main spectrometer) for energy analysis, followed by a detector system for counting transmitted beta decay electrons. Measurements performed at the KATRIN pre-spectrometer test setup showed that the decay of radon (Rn) atoms in the volume of the KATRIN spectrometers is a major background source. Rn atoms from low-level radon emanation of materials inside the vacuum region of the KATRIN spectrometers are able to penetrate deep into the magnetic flux tube so that the alpha decay of Rn contributes to the background. Of particular importance are electrons emitted in processes accompanying the Rn alpha decay, such as shake-off, internal conversion of excited levels in the Rn daughter atoms and Auger electrons. Lowenergy electrons (< 100 eV) directly contribute to the background in the signal region. High-energy electrons can be stored magnetically inside the volume of the spectrometer and are able to create thousands of secondary electrons via subsequent ionization processes with residual gas molecules. In order to reduce the Rn induced background different active and passive counter measures were developed and tested. This proceeding will give an overview on Rn sources within the KATRIN spectrometer, describes how Rn decays inside the spectrometer produce background events at the detector and presents different counter measures to reduce the Rn induced background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data quality assurance for the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 7648 Ge-enriched germanium detectors totalling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Any Neutrinoless double-beta decay search requires a thorough understanding of the background and the signal energy spectra. This talk will discuss the various techniques employed to ensure the integrity of the measured spectra. Data collection is monitored with a thorough set of checks, and subsequent careful analysis is performed to qualify the data for higher level physics analysis. Instrumental background events are tagged for removal, and problematic channels are removed from consideration as necessary.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results from the Cuore Experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. The detector consists of an array of 988 TeO 2 crystals arranged in a cylindrical compact structure of 19 towers, each of them made of 52 crystals. Here, the construction of the experiment was completed in August 2016 and the data taking started in spring 2017 after a period of commissioning and tests. In this work we present the neutrinoless double beta decay results of CUORE from examining a total TeO 2 exposure of 86.3 kg yr , characterized by an effective energy resolution of 7.7 keV FWHM and a background in the region of interest of 0.014 counts/(keV kg yr) . In this physics run, CUORE placed a lower limit on the decay half-life of neutrinoless double beta decay of 130 Te > 1.3 • 10 25 yr (90% C.L.). Moreover, an analysis of the background of the experiment is presented as well as the measurement of the 130 Te 2 νββ decay with a resulting half-life of T 2ν 1/2 = [7.9 ± 0.1(stat.) ± 0.2(syst.)] × 10 20 yr which is the most precise measurement of the half-life and compatible with previous results.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Precision Half-Life Measurement for the Superallowed {beta}{sup +} Emitter {sup 26}Al{sup m}

A high-precision half-life measurement for the superallowed {beta}{sup +} emitter {sup 26}Al{sup m} was performed at the TRIUMF-ISAC radioactive ion beam facility yielding T{sub 1/2}=6346.54{+-}0.46{sub stat{+-}}0.60{sub syst} ms, consistent with, but 2.5 times more precise than, the previous world average. The {sup 26}Al{sup m} half-life and ft value, 3037.53(61) s, are now the most precisely determined for any superallowed {beta} decay. Combined with recent theoretical corrections for isospin-symmetry-breaking and radiative effects, the corrected Ft value for {sup 26}Al{sup m}, 3073.0(12) s, sets a new benchmark for the high-precision superallowed Fermi {beta}-decay studies used to test the conserved vector current hypothesis and determine the V{sub ud} element of the Cabibbo-Kobayashi-Maskawa quark mixing matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Giant Gamow-Teller resonance in neutron-rich nuclei

The giant Gamow-Teller resonance and other branches of collective nuclear excitations are described on the basis of the theory of finite Fermi systems. A connection between the Gamow-Teller resonance and Wigner SU(4) symmetry is proven. The beta-decay strength function and processes accompanying the {beta}{sup -} decay of neutron-rich nuclei are described. The effect of the satellites of the Gamow-Teller resonance on the decay properties of neutron-rich nuclei is analyzed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Production of Neutron-Rich Bi Isotopes by Electric Fields

The short time (approx10 minutes) high voltage electrolysis of nitrate bismuth solution was performed. After electrolysis about 30 mg of electrolyte have been dried up on a thin polyethylene film. The sample obtained was placed into the detecting system (Si detector and plastic detector). Alpha-radioactivity of the sample was measured. The results showed that alpha-radioactivity increased about 100 times to the base level. The radioactivity decreasing was about 2 times for 50 minutes. Some signals from the Si detector was accompanied by a signal from the electron detector (22 events). The signal from the plastic detector for all the events the electron recorded preceded the Si detector signal with delay less than 1.4 musec. The conclusion was made that beta-decay of nuclei {sup 212}Bi and the subsequent alpha-decay of nuclei {sup 212}Po were recorded. The effect was reproduced in 28 experiments. The possible explanation of the phenomenon was given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dynamical r-process studies within the neutrino-driven wind scenario and its sensitivity to the nuclear physics input

We use results from long-time core-collapse supernovae simulations to investigate the impact of the late time evolution of the ejecta and of the nuclear physics input on the calculated r-process abundances. Based on the latest hydrodynamical simulations, heavy r-process elements cannot be synthesized in the neutrino-driven winds that follow the supernova explosion. However, by artificially increasing the wind entropy, elements up to A=195 can be made. In this way one can reproduce the typical behavior of high-entropy ejecta where the r process is expected to occur. We identify which nuclear physics input is more important depending on the dynamical evolution of the ejecta. When the evolution proceeds at high temperatures (hot r process), an (n,{gamma})<-->({gamma},n) equilibrium is reached, while at low temperatures (cold r process) there is a competition between neutron captures and beta decays. In the first phase of the r process, while enough neutrons are available, the most relevant nuclear physics inputs are the nuclear masses for the hot r process and the neutron capture and beta-decay rates for the cold r process. At the end of this phase, the abundances follow a steady beta flow for the hot r process and a steady flow of neutron captures and beta decays for the cold r process. After neutrons are almost exhausted, matter decays to stability and our results show that in both cases neutron captures are key for determining the final abundances, the position of the r-process peaks, and the formation of the rare-earth peak. In all the cases studied, we find that the freeze-out occurs in a time scale of several seconds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of isomers in the neutron-rich odd-odd nucleus {sup 156}Pm

Critical examination of the experimental data from {sup 156}Nd and {sup 156}Pm {beta} decays and the observed location of relevant neutron and proton orbitals in the neighboring odd-A isotones and isotopes, taken together with the low-lying two-quasiparticle (2qp) structures expected in {sup 156}Pm from the rotor-particle model, lead to the conclusion that a consistent description of all the available data is achieved with the I{sup {pi}}=4{sup +} spin-parity assignment to the 26.7s {sup 156}Pm ground state (g.s.) and assignment of I{sup {pi}}=1{sup +} to its 150.3-keV isomer with the 2qp configuration 4{sub g.s.}{sup +}{l_brace}p{sub o}:5/2[532{up_arrow}]{+-}n{sub o}:3/2[521{up_arrow}]{r_brace}1{sub 150}{sup +}. In the process, a two-neutron configuration is also suggested for the 1509-keV 4{sup +} level in the daughter nucleus {sup 156}Sm. The present analysis reiterates the important question of whether the {beta}-decay log ft value, by itself, can be employed to deduce the relative parity of the {beta}-connected states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the Majorana Demonstrator experiment

The Majorana Demonstrator neutrinoless double beta-decay experiment is currently under construction at the Sanford Underground Research Facility in South Dakota, USA. An overview and status of the experiment are given.

Martin, R.D.↗

Gamow-Teller Transitions in Proton Rich Exotic pf-shell Nuclei Deduced from Mirror Transitions

The rp-process nucleosynthesis proceeds through nuclei near the proton drip-line, in which Gamow-Teller (GT) transitions starting from unstable pf-shell nuclei play important roles. In the {beta}-decay study of these nuclei, half-lives can be measured rather accurately. On the other hand, in the high-resolution ({sup 3}He, t) charge-exchange reactions on mirror nuclei, individual GT transitions can be studied up to high excitations. For the accurate study of the GT transition strengths in the A = 52, T = 2, system, we compare and combine the {beta}-decay study of the proton-rich nucleus {sup 52}Ni and the {sup 52}Cr({sup 3}He, t) measurement assuming the isospin symmetry of the T{sub z} = {+-}2{yields}{+-}1 transitions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spatial and Time Coincidence Detection of the Decay Chain of Short-Lived Radioactive Nuclei

The quantum counting position sensitive pixel detector Timepix with per-pixel energy and time resolution enables to detect radioactive ions and register the consecutive decay chain by simultaneous position-and time-correlation. This spatial and timing coincidence technique in the same sensor is demonstrated by the registration of the decay chain {sup 8}He{yields}{sup {beta} 8}Li and {sup 8}Li{yields}{sup {beta}-} {sup 8}Be{yields}{alpha}+{alpha} and by the measurement of the {beta} decay half-lives. Radioactive ions, selectively obtained from the Lohengrin fission fragment spectrometer installed at the High Flux Reactor of the ILL Grenoble, are delivered to the Timepix silicon sensor where decays of the implanted ions and daughter nuclei are registered and visualized. We measure decay lifetimes in the range {>=}{mu}s with precision limited just by counting statistics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Enriched Xenon Observatory

The Enriched Xenon Observatory (EXO) experiment will search for neutrinoless double beta decay of {sup 136}Xe. The EXO Collaboration is actively pursuing both liquid-phase and gas-phase Xe detector technologies with scalability to the ton-scale. The search for neutrinoless double beta decay of {sup 136}Xe is especially attractive because of the possibility of tagging the resulting Ba daughter ion, eliminating all sources of background other than the two neutrino decay mode. EXO-200, the first phase of the project, is a liquid Xe time projection chamber with 200 kg of Xe enriched to 80% in {sup 136}Xe. EXO-200, which does not include Ba-tagging, will begin taking data in 2009, with two-year sensitivity to the half-life for neutrinoless double beta decay of 6.4x10{sup 25} years. This corresponds to an effective Majorana neutrino mass of 0.13 to 0.19 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Project 8 Phase II

The Project 8 collaboration aims to measure the absolute neutrino mass scale using cyclotron radiation emission spectroscopy on the beta decay of tritium. The second phase of the project will measure a continuous spectrum of molecular tritium beta decays and extract the tritium endpoint value with an eV or sub-eV scale precision. Monoenergetic electrons emitted by gaseous $^{83\mathrm{m}}$Kr atoms are used to determine the relationship between cyclotron frequency and electron energy. This study allows us to optimize both the event reconstruction algorithm and the hardware configuration, in preparation for measuring the tritium beta decay spectrum. Phase II will benefit from a gas system of krypton and tritium that will allow measurement and offline correction for magnetic field fluctuations. We present the recent progress in understanding the electron kinematics and implementing the magnetic field calibration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cosmogenic 137 Xe Analysis of Alternatives for nEXO

Neutrinoless double-beta decay is a hypothetical nuclear decay in which two matter particles are produced without corresponding antimatter particles. Observation of neutrinoless double-beta decay would shed light on a potential explanation of matter-antimatter observed in the universe and also indicate the Majorana nature of neutrinos, meaning that the neutrino can act as its own antiparticle. The nEXO experiment is a proposed 5-ton liquid xenon time projection chamber detector with a projected 1.35 × 10 28 yr half-life sensitivity to neutrinoless double-beta decay in 136 Xe [J. Phys. G 49, 015104 (2022)]. While nEXO has a baseline location of SNOLAB, there are several other underground facilities in the world capable of hosting the experiment. The primary change at each site will be cosmogenic 137 Xe backgrounds, caused by varied cosmogenic muon activity at each site. This study finds that while there is a negligible increase in nEXO’s half-life sensitivity at 90% C.L. from improving the cosmogenic 137 Xe veto rejection procedure for SNOLAB, much higher daily muon rates at three other sites will have an adversely negative effect on nEXO’s sensitivity and would likely require further modifications to nEXO’s baseline design to reach nEXO’s scientific goals. Monte Carlo simulations of muons inducing 137 Xe backgrounds were conducted at four underground sites, SNOLAB, SURF, LNGS, and WIPP, each with roughly a factor of 10 times higher daily muon activity than the previous site. There were two primary inputs to these simulations. The first was sample data of cosmogenic muon flight through nEXO’s outer detector, a 12.8m tall and 12.3m wide cylindrical water tank lined with photomultiplier tubes to detect Cerenkov radiation, and all of the secondary interactions produced in the detector. The second input was a parametrization of 137 Xe* production tagging when 137 Xe de-excites and release prompt gammas, as well as accidental tagging caused by neutron capture on 63 Cu, 65 Cu, 19 F, and 1 H throughout the detector. Together, the number of backgrounds relative to the previous 2021 Sensitivity Paper [J. Phys. G 49, 015104 (2022)] was found at each of these four sites across three energy windows, from 400, 1400, and 2600 keV all up to 4600 keV, just above the end point of the prompt gamma spectrum for 137 Xe*. Using level curves for the sensitivity as 137 Xe backgrounds scale relative to baseline calculations, the half-life sensitivity at 90% C.L. for each of trial was found. Even with reduced 137 Xe backgrounds, the results for SNOLAB yielded neglible improvements in nEXO’s predicted sensitivity. On the contrary, the increased backgrounds for the three other considered sites yielded sensitivity estimates below nEXO’s previous projections. This study demonstrates that the shielding from cosmogenic muons at SNOLAB makes it highly preferred even amongst other world leading underground laboratories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extracting information from 0νββ decay and LHC pp-cross sections: Limits on the left-right mixing angle and right-handed boson mass

The existence of massive neutrinos forces the extension of the Standard Model of electroweak interactions, to accommodate them and/or right-handed currents. This is one of the fundamental questions in todays’s physics. The consequences of it would reflect upon several decay processes, like the very exotic nuclear double-beta-decay. By the other hand, high-energy proton-proton reactions of the type performed at the LHC accelerator can provide information about the existence of a right-handed generation of the W and Z-bosons. Here we shall address the possibility of performing a joint analysis of the results reported by the ATLAS and CMS collaborations (σ(pp− > 2l + jets)) and the latest measurements of nuclear-double-beta decays reported by the GERDA and EXO collaborations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗