Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Pulsed electron beam emission in space

During the Spacelab-2 mission of July 1985, electron beams (1 keV, 50-150 mA) pulsed at ELF and VLF frequencies were emitted from the Space Shuttle Orbiter. The wave fields generated by the beam were monitored by a Plasma Diagnostics Package which was released as a free-flying subsatellite during a six hour period. Measurements of the Orbiter potential and the return current during beam emissions were obtained from a Charge and Current Probe mounted in the payload bay.

Neubert, T.↗

DESIGN OF VISIBLE DIAGNOSTIC BEAMLINE FOR NSLS2 STORAGE RING

A visible synchrotron light monitor (SLM) beam line has been designed at the NSLS2 storage ring, using the bending magnet radiation. A retractable thin absorber will be placed in front of the first mirror to block the central x-rays. The first mirror will reflect the visible light through a vacuum window. The light is guided by three 6-inch diameter mirrors into the experiment hutch. In this paper, we will describe design work on various optical components in the beamline. The ultra high brightness NSLS-II storage ring is under construction at Brookhaven National Laboratory. It will have 3GeV, 500mA electron beam circulating in the 792m ring, with very low emittance (0.9nm.rad horizontal and 8pm.rad vertical). The ring is composed of 30 DBA cells with 15 fold symmetry. Three damping wigglers will be installed in long straight sections 8, 18 and 28 to lower the emittance. While electrons pass through the bending magnet, synchrotron radiation will be generated covering a wide spectrum. There are other insertion devices in the storage ring which will generate shorter wavelength radiation as well. Synchrotron radiation has been widely used as diagnostic tool to measure the transverse and longitudinal profile. Three synchrotron light beam lines dedicated for diagnostics are under design and construction for the NSLS-II storage ring: two x-ray beam lines (pinhole and CRL) with the source points from Cell 22 BM{_}A (first bending in the DBA cell) and Cell22 three-pole wiggler; the third beam line is using visible part of radiation from Cell 30 BM{_}B (second bending magnet from the cell). Our paper focuses on the design of the visible beam line - SLM.

43 PARTICLE ACCELERATORS↗

A modular optics design for the LBNE beamline

Protons extracted from the Main Injector (MI) in the MI-60 straight section are transported 84 m through quadrupole Q106 in the NuMI stub, at which point two 6-3-120 vertical switching magnets, followed by three EPB vertical dipoles, steer the beam into the main body of the LBNE beamline. From Q106 in NuMI the LBNE beamline transports these protons 722.0 m to the LBNE target, located 41.77 m (137.0 ft) below the MI beamline center (BLC) elevation, on a trajectory aimed towards DUSEL. Bending is provided (predominantly) by 34 long (6 m) MI-style IDA/IDB and 8 short (4 m) IDC/IDD dipoles [through 48.36{sup o} horizontally and -5.844{sup o} (net) vertically]. Optical properties are defined by 49 quadrupoles (grouped functionally into 44 focusing centers) of the proven MI beamline-style 3Q60/3Q120 series. All focusing centers are equipped with redesigned MI-style IDS orbit correctors and dual-plane beam position monitors (BPM's). Ample space is available in each arc cell to accommodate ion pumps and diagnostic instrumentation. Parameters of the main magnets are listed in a table.

43 PARTICLE ACCELERATORS↗

Near real-time ORM measurements and SVD matrix generation for 10 Hz global orbit feedback in RHIC

To reduce the effect of trajectory perturbations ({approx}10 Hz) due to vibrations of the final focusing quadrupoles at RHIC, global orbit feedback was successfully prototyped during run-10. After upgraded to a system with 36 BPMs and 12 correctors, 10 Hz feedback was tested successfully in Run-11 and is in operational status for physics program. The test and operation of the system has been performed using transfer functions between the beam position monitors and correctors obtained from the online optics model and a correction algorithm based on singular value decomposition (SVD). One of our goals is to self-calibrate the system using SVD matrices derived from orbit response matrix (ORM) measurements acquired real-time using the new FPGA-based signal processing. Comparisons between measurement matrix and model matrix and the generation of SVD matrix for the feedback operation are presented.

43 PARTICLE ACCELERATORS↗

Nonlinear dynamics studies in the Fermilab tevatron using an AC dipole

An AC dipole magnet produces a sinusoidally oscillating dipole field with frequency close to betatron frequency and excites large sustained oscillations of beam particles circulating in a synchrotron. Observation of such oscillations with beam position monitors allows direct measurements of a synchrotron's nonlinear parameters. This paper presents experimental studies to measure perturbative effects of sextupole and octupole fields, performed in the Fermilab Tevatron using an ACdipole.

43 PARTICLE ACCELERATORS↗

Theoretical and numerical analyses of a slit-masked chicane for modulated bunch generation

Density modulations on electron beams can improve machine performance of beam-driven accelerators and FELs with resonance beam-wave coupling. The beam modulation is studied with a masked chicane by the analytic model and simulations with the beam parameters of the Fermilab Accelerator Science and Technology (FAST) facility. With the chicane design parameters (bending angle of 18o, bending radius of 0.95 m and R 56 ~ –0.19 m) and a nominal beam of 3 ps bunch length, the analytic model showed that a slit-mask with slit period 900 μ m and aperture width 300 μ m induces a modulation of bunch-to-bunch spacing ~ 100 μ m to the bunch with 2.4% correlated energy spread. With the designed slit mask and a 3 ps bunch, particle-in-cell (PIC) simulations, including nonlinear energy distributions, space charge force, and coherent synchrotron radiation (CSR) effect, also result in beam modulation with bunch-to-bunch distance around 100 μ m and a corresponding modulation frequency of 3 THz. The beam modulation has been extensively examined with three different beam conditions, 2.25 ps (0.25 nC), 3.25 ps (1 nC), and 4.75 ps (3.2 nC), by tracking code Elegant. The simulation analysis indicates that the sliced beam by the slit-mask with 3 ~ 6% correlated energy spread has modulation lengths about 187 μ m (0.25 nC), 270 μ m (1 nC) and 325 μ m (3.2 nC). As a result, the theoretical and numerical data proved the capability of the designed masked chicane in producing modulated bunch train with micro-bunch length around 100 fs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pion contamination in the MICE muon beam

Here, the international Muon Ionization Cooling Experiment (MICE) will perform a systematic investigation of ionization cooling with muon beams of momentum between 140 and 240\,MeV/c at the Rutherford Appleton Laboratory ISIS facility. The measurement of ionization cooling in MICE relies on the selection of a pure sample of muons that traverse the experiment. To make this selection, the MICE Muon Beam is designed to deliver a beam of muons with less than $\sim$1% contamination. To make the final muon selection, MICE employs a particle-identification (PID) system upstream and downstream of the cooling cell. The PID system includes time-of-flight hodoscopes, threshold-Cherenkov counters and calorimetry. The upper limit for the pion contamination measured in this paper is $f_\pi < 1.4\%$ at 90% C.L., including systematic uncertainties. Therefore, the MICE Muon Beam is able to meet the stringent pion-contamination requirements of the study of ionization cooling.

43 PARTICLE ACCELERATORS↗

IOTA (Integrable Optics Test Accelerator): Facility and experimental beam physics program

The Integrable Optics Test Accelerator (IOTA) is a storage ring for advanced beam physics research currently being built and commissioned at Fermilab. It will operate with protons and electrons using injectors with momenta of 70 and 150 MeV/c, respectively. The research program includes the study of nonlinear focusing integrable optical beam lattices based on special magnets and electron lenses, beam dynamics of space-charge effects and their compensation, optical stochastic cooling, and several other experiments. In this article, we present the design and main parameters of the facility, outline progress to date and provide the timeline of the construction, commissioning and research. Finally, the physical principles, design, and hardware implementation plans for the major IOTA experiments are also discussed.

43 PARTICLE ACCELERATORS↗

A Project to Design and Build the Magnets for a New Test Beamline, the ATF2, at KEK

In order to achieve the high luminosity required at the proposed International Linear Collider (ILC), it is critical to focus the beams to nanometer size with the ILC Beam Delivery System, and to maintain the beams collisions with a nanometer-scale stability. To establish the technologies associated with this ultra-high precision beam handling, a special beamline has been designed and built as an extension of the existing extraction beamline of the Accelerator Test Facility at KEK, Japan. The ATF provides an adequate ultra-low emittance electron beam that is comparable to the ILC requirements; the ATF2 mimics the ILC final focus system to create a tightly focused, stable beam. There are 37 magnets in the ATF2, 29 quadrupoles, 5 sextupoles and 3 bends. These magnets had to be acquired in a short time and at minimum cost, which led to various acquisition strategies; but nevertheless they had to meet strict requirements on integrated strength, physical dimensions, compatibility with existing magnet movers and beam position monitors, mechanical stability and field stability and quality. This paper will describe how 2 styles of quadrupoles, 2 styles of sextupoles, one dipole style and their supports were designed, fabricated, refurbished or modified, measured and aligned by a small team of engineers from 3 continents.

43 PARTICLE ACCELERATORS↗

Sub-THz passive detector performance evaluation with RadiaBeam photoinjector

Wakefield accelerators, based on THz and mm-wave structures, promise to reach the highest energies in record small footprints. However, operation at such frequencies is associated with strong generation of dipole modes that can destroy the beams, which requires controlling the electron beam position at the micron scale. The existing conventional techniques for electron beam position monitoring are not applicable for sub-THz structures due to the space constraints. Here, on the other hand, if dipole modes amplitudes can be measured precisely at different planes, one can derive beam position relative to the central axis. For such a technique a reliable and cost-effective sensor capable of operating in high repletion rate regime is required. In this paper we review the experimental evaluation of a passive sensor candidate for such applications using RadiaBeam 4.5 MeV photoinjector.

Accelerator↗

HIGH POWER BEAM DUMP AND TARGET / ACCELERATOR INTERFACE PROCEDURES

Satisfying operational procedures and limits for the beam target interface is a critical concern for high power operation at spallation neutron sources. At the Oak Ridge Spallation Neutron Source (SNS) a number of protective measures are instituted to ensure that the beam position, beam size and peak intensity are within acceptable limits at the target and high power Ring Injection Dump (RID). The high power beam dump typically handles up to 50 100 kW of beam power and its setup is complicated by the fact that there are two separate beam components simultaneously directed to the dump. The beam on target is typically in the 800-1000 kW average power level, delivered in sub- s 60 Hz pulses. Setup techniques using beam measurements to quantify the beam parameters at the target and dump will be described. However, not all the instrumentation used for the setup and initial qualification is available during high power operation. Additional techniques are used to monitor the beam during high power operation to ensure the setup conditions are maintained, and these are also described.

Blokland, Willem↗

Simple Low-Frequency Beam Pickup

Detection of the field induced by a beam outside of the beam pipe can be used as a beam diagnostic. Wires placed in longitudinal slots in the outside wall of the beam pipe can be used as a beam pickup. This has a very small beam-coupling impedance and avoids complications of having a feedthrough. The signal can be reasonably high at low frequencies. We present a field waveform at the outer side of a beam pipe, obtained as a result of calculations and measurements. We calculate the beam-coupling impedance due to a long longitudinal slot in the resistive wall and the signal induced in a wire placed in such a slot and shielded by a thin screen from the beam. These results should be relevant for impedance calculations of the slot in an antechamber and for slots in the PEP-II distributed ion pump screens. The design of the low-frequency beam position monitor is very simple. It can be used in storage rings, synchrotron light sources, and free electron lasers, like LINAC coherent light source.

43 PARTICLE ACCELERATORS↗

Lattice Calibration with Turn-By-Turn BPM Data

Turn-by-turn beam position monitor (BPM) data from multiple BPMs are fitted with a tracking code to calibrate magnet strengths in a manner similar to the well known LOCO code. Simulation shows that this turn-by-turn method can be a quick and efficient way for optics calibration. The method is applicable to both linacs and ring accelerators. Experimental results for a section of the SPEAR3 ring is also shown.

43 PARTICLE ACCELERATORS↗

BPM Offset of NSLS-II Storage Ring Based on BBA Measurement

Beam based alignment (BBA) is the final calibration of the Beam position monitor (BPM) readings based on the quadrupole centers and it becomes essential process for the modern synchrotron light sources. For the convenient BBA implementation, usually BPMs are placed close to the quadrupoles and the beam is adjusted to pass the center of the quadrupoles. Therefore, measured BPM BBAs are, in fact, the BPM offsets relative to the quadrupole centers, and by observing their variations, we can estimate the relative movements of the BPMs. In NSLS-II, the BPM BBAs are measured whenever the beam-time allows and the variations are being observed. However, because changing BBAs in the BPM readings has direct and significant impact on the machine operation as well as the user experiments, they are not applied instantly. Instead, in NSLS-II, the official BBA values are managed by the snapshot archiving and retrieving system, called MASAR (MAchine Snapshot Archiving and Retrieve), so that they are well organized and can be easily set to any stored set of BBAs values. NSLS-II is implementing MASAR as a part of EPICS control system for the convenient and mistake-free machine operation. Each snapshot is a group of key-value pairs where keys are EPICS Process Variables (PVs). The snapshots are organized by configurations where each configuration has specific PV sets. And each configuration saves snapshots with titles corresponding their purposes such as normal user operations or specific beam studies. Anyone with control system account can save snapshots and they can be restored whenever needed. One of the configurations is “SR_BPM_BBAS" and the configuration includes the set of EPICS PVs for the storage ring BPM BBA values. This configuration also includes the BBAs of the in the straight sections, called ID (insertion device) BPMs playing important roles in user experiments. The ID BPM BBAs are also directly engaged in the active interlock (AI) machine protection system, which prevents the mechanical damage from the ID radiation. However, in estimating ID BPM BBAs, because there is no quadrupoles around them, interpolations from the surrounding sector BPM BBAs are used. This note focuses on the BPM offset variations based on the BBA measurement data and does not discuss about the ID BPM BBAs because they are not the direct measures of the offsets.

36 MATERIALS SCIENCE↗

Direct Measurement of Backstreaming Ions from the Axis 2 Septum Dump and RF Generation

The DARHT-II accelerator produces a 2-kA, 17-MeV beam in a 1600-ns pulse. After exiting the accelerator, the pulse is sliced into four short pulses by a kicker and quadrupole septum and then transported for several meters to a high Z material target for conversion to x-rays for radiography. The un-kicked beam is diverted to a graphite dump. The interaction of this beam with the dump produces ions that propagate back to the target beamline and affect the beam properties. Coupling of the electron beam and ions to the beam dump vacuum chamber can also produce significant amounts of radiofrequency fields (RF) that disrupt the beam transport to the target. This requires a change in the nominal tune in order to minimize the heating of the carbon beam dump and suppress desorption of ions. Initially, ions are generated through stimulated desorption and ionization of the monolayers of water vapor stuck to the beam dump surface. These ions propagate upstream at high speeds and act as an electrostatic focusing lens by reducing the beam space charge. As the beam size on the dump decreases, the dump is sufficiently heated so that a surface plasma is formed and much greater quantities of ions are generated through temperature limited thermionic emission. The interaction of these ions with the beam creates RF which causes significant disruption of the beam. The results of a 3D PIC simulation show that ions can propagate back to the target beam line in about 500 ns. A beam position monitor (BPM) located just upstream of the septum was modified to include four capacitive pickups in addition to four of the usual inductive pickups. The inductive and capacitive pickups provide a measure of the beam current. The capacitive pickups are very sensitive to low velocity ions. As ions from the beam dump pass through the BPM the inductive and capacitive pickup will record two different measures of the beam current. Initial results from this BPM will be discussed along with other measurements which indicate the presence of backstreaming ions.

43 PARTICLE ACCELERATORS↗

Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

Beam diagnostics is an essential constituent of any accelerator, so that it is named as "organs of sense" or "eyes of the accelerator." Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the difficulty of diagnostics. For most cases, intercepting measurements are no longer acceptable, and nonintercepting method like synchrotron radiation monitor can not be applied to linear accelerators. The development of accelerator technology asks for simutanous diagnostics innovations, to expand the performance of diagnostic tools to meet the requirements of the next generation accelerators. Diffraction radiation and inverse Compton scattering are two of the most promising techniques, their nonintercepting nature avoids perturbance to the beam and damage to the instrumentation. This thesis is divided into two parts, beam size measurement by optical diffraction radiation and Laser system for Compton polarimeter. Diffraction radiation, produced by the interaction between the electric field of charged particles and the target, is related to transition radiation. Even though the theory of diffraction radiation has been discussed since 1960s, there are only a few experimental studies in recent years. The successful beam size measurement by optical diffraction radiation at CEBAF machine is a milestone: First of all, we have successfully demonstrated diffraction radiation as an effective nonintercepting diagnostics; Secondly, the simple linear relationship between the diffraction radiation image size and the actual beam size improves the reliability of ODR measurements; And, we measured the polarized components of diffraction radiation for the first time and I analyzed the contribution from edge radiation to diffraction radiation.

43 PARTICLE ACCELERATORS↗

MODEL BASED ORBIT CORRECTION IN A DIAGNOSTICS DEFICIENT REGION

An orbit correction method is presented for a region where the number of beam position monitors is much less than the number of possible trajectory distortions points (quads). The method was developed for the Coupled Cavities Linac (CCL) part of the Spallation Neutron Source (SNS) linac. The orbit correction is very important in this region to minimize losses and activation, but a traditional orbit correction did not work here. The new method based on a realistic online model was developed. The procedure of a model parameters finding and results are discussed

43 PARTICLE ACCELERATORS↗