Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Distribution Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

The Effect of Transport and Circulation Differences on Stratospheric Ozone Recovery in Two 35-year Three-dimensional Simulations

The NASA Global Modeling Initiative (GMI) has completed two 35-year simulations with WMO future baseline boundary conditions that simulate increasing N2O and CH4 emissions and decreasing organic chlorine and bromine emissions. Simulations were done with the GMI offline chemistry and transport model using 1) 1 year of winds from the Finite-Volume General Circulation Model (FV-GCM), repeated for the 35 years, and 2) 1 year of winds from the Finite-Volume Data Assimilation System (FV-DAS), repeated for 35-years. The simulations have full stratospheric chemistry. To understand differences in simulated ozone recoveries, basic transport and circulation differences between these models are evaluated. The distribution of mean age of stratospheric air in the FV-GCM run agrees well with observations in the lower stratosphere but the FV-DAS ages are generally too low. This implies circulation and mixing differences that will affect the distributions of other trace species such as CH4, NO, and the organic halogens, all of which are responding to changing boundary conditions and are involved in ozone loss. Realism of model transport is evaluated, with particular attention given to regions and seasons where ozone recovery is expected. Preliminary results indicate increasing ozone trends in the lowermost stratosphere in summer and in the Antarctic and Arctic lower stratosphere in winter and spring.

Bhartia, P. K.↗

Potential Applications of Active Antenna Technologies for Emerging NASA Space Communications Scenarios

Abstract—The National Aeronautics and Space Administration (NASA) is presently embarking on the implementation of far-reaching changes within the framework of both space and aeronautics communications architectures. For example, near earth relays are looking to transition from the traditional few large geostationary satellites to satellite constellations consisting of thousands of small low earth orbiting satellites while lunar space communications will require the need to relay data from many assets distributed on the lunar surface back to earth. Furthermore, within the aeronautics realm, satellite communications for beyond line of sight (BLOS) links are being investigated in tandem with the proliferation of unmanned aerial systems (UAS) within the urban air mobility (UAM) environment. In all of these scenarios, future communications architectures will demand the need to connect and quickly transition between many nodes for large data volume transport. As such, NASA Glenn Research Center (GRC) has been heavily investigating the development of low cost phased array technologies that can readily address these various scenario conditions. In particular, GRC is presently exploring 5G-based beamformer technologies to leverage commercial timescale and volume production cycles which have heretofore not existed within the frequency allocations utilized for NASA applications. In this paper, an overview of the potential future applications of phased arrays being envisioned by NASA are discussed, along with technology feasibility demonstrations being conducted by GRC implementing low cost, 5G based beamformer technologies.

Nessel, James A.↗

Characterization of Large Drop Velocity in the NASA Icing Research Tunnel

This presentation presents experimental work conducted in the Icing Research Tunnel at NASA Glenn Research Center to characterize the velocity of large drops in the tunnel test section. Some icing spray clouds with large-sized drops were generated with Mod1 nozzles at low nozzle air pressure of 2 to 4 psig for various tunnel air speeds. Drop diameters and drop velocities were measured via high-resolution imaging with a Particle Imaging Particle Tracking Velocimetry probe developed by Artium Technologies. The probe was mounted at four different locations aligned with the centerline of the test section from near the end of the contraction to the constant height test section part of the tunnel. CFD analyses were performed. It showed that the probe head geometry affects the local air flow between the prongs and in front of the probe. Initial analysis of the air velocity data during the test also indicated that the probe mounting stand has blockage effect on the local tunnel air velocity measurement by a Pitot static probe affixed on the mounting plate. Those findings were later verified in the Icing Research Tunnel using a new Pitot probe design with a linear motion system to measure the local tunnel air velocity with and without the probe. As a result, additional drop trajectory simulations as airflow moving towards the probe head were run for a Langmuir-D 7-bin drop size distribution of a spray cloud with a nominally large value of medium volumetric diameter. The simulation results helped identify a critical drop-size threshold of 300 µm above which the velocities of larger drops are not affected by the adverse pressure gradient generated by the probe head due to their large drop inertia. From the dimensional analysis of the drop velocity measurement data obtained, it showed that at the tunnel test section reference location a generalized empirical correlation was developed for the non-dimensional drop velocity as a function of the non-dimensional corrected drop diameter independent of the actual spraybar pressure settings and the tunnel air speeds. The generalized curve-fit correlation showed that the drop velocity was universally asymptotic to about 86 percent of the corresponding tunnel air speed at the test section reference location for the largest drop diameter captured by the probe. Further evaluation of this correlation is recommended to assess its applicability for Supercooled Large Drop icing scaling applications in the Icing Research Tunnel.

SLD↗

Technology Candidates for Air-to-Air and Air-to-Ground Data Exchange

Technology Candidates for Air-to-Air and Air-to-Ground Data Exchange is a two-year research effort to visualize the U. S. aviation industry at a point 50 years in the future, and to define potential communication solutions to meet those future data exchange needs. The research team, led by XCELAR, was tasked with identifying future National Airspace System (NAS) scenarios, determining requirements and functions (including gaps), investigating technical and business issues for air, ground, & air-to-ground interactions, and reporting on the results. The project was conducted under technical direction from NASA and in collaboration with XCELAR's partner, National Institute of Aerospace, and NASA technical representatives. Parallel efforts were initiated to define the information exchange functional needs of the future NAS, and specific communication link technologies to potentially serve those needs. Those efforts converged with the mapping of each identified future NAS function to potential enabling communication solutions; those solutions were then compared with, and ranked relative to, each other on a technical basis in a structured analysis process. The technical solutions emerging from that process were then assessed from a business case perspective to determine their viability from a real-world adoption and deployment standpoint. The results of that analysis produced a proposed set of future solutions and most promising candidate technologies. Gap analyses were conducted at two points in the process, the first examining technical factors, and the second as part of the business case analysis. In each case, no gaps or unmet needs were identified in applying the solutions evaluated to the requirements identified. The future communication solutions identified in the research comprise both specific link technologies and two enabling technologies that apply to most or all specific links. As a result, the research resulted in a new analysis approach, viewing the underlying architecture of ground-air and air-air communications as a whole, rather than as simple "link to function" paired solutions. For the business case analysis, a number of "reference architectures" were developed for both the future technologies and the current systems, based on three typical configurations of current aircraft. Current and future costs were assigned, and various comparisons made between the current and future architectures. In general, it was assumed that if a future architecture offers lower cost than the current typical architecture, while delivering equivalent or better performance, it is likely that the future solution will gain industry acceptance. Conversely, future architectures presenting higher costs than their current counterparts must present a compelling benefit case in other areas or risk a lack of industry acceptance. The business case analysis consistently indicated lower costs for the proposed future architectures, and in most cases, significantly so. The proposed future solutions were found to offer significantly greater functionality, flexibility, and growth potential over time, at lower cost, than current systems. This was true for overall, fleet-wide equipage for domestic and oceanic air carriers, as well as for single, General Aviation (GA) aircraft. The overall research results indicate that all identified requirements can be met by the proposed solutions with significant capacity for future growth. Results also illustrate that the majority of the future communication needs can be met using currently allocated aviation RF spectrum, if used in more effective ways than it is today. A combination of such optimized aviation-specific links and commercial communication systems meets all identified needs for the 50-year future and beyond, with the caveat that a new, overall function will be needed to manage all information exchange, individual links, security, cost, and other factors. This function was labeled "Delivery Manager" (DM) within this research. DM employs a distributed client/server architecture, for both airborne and ground communications architectures. Final research results included identifying the most promising candidate technologies for the future system, conclusions and recommendations, and identifying areas where further research should be considered.

Communications↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources: Preprint

Integration of a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problem requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs) including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperformed other benchmark controllers regarding computation time without compromising operational performance.

DER↗

UTEMPRA - Unitary Thermal Energy Management for Propulsion Range Augmentation

Key hurdles to achieving wide consumer acceptance of battery electric vehicles (BEVs) are weather-dependent drive range, higher cost, and limited battery life. These translate into a strong need to reduce a significant energy drain and resulting drive range loss due to auxiliary electrical loads the predominant of which is the cabin thermal management load. Studies have shown that thermal subsystem loads can reduce the drive range by as much as 45% under ambient temperatures below -10 degrees C. Often, cabin heating relies purely on positive temperature coefficient (PTC) resistive heating, contributing to a significant range loss. Reducing this range loss may improve consumer acceptance of BEVs. The authors present a unified thermal management system (UTEMPRA) that satisfies diverse thermal and design needs of the auxiliary loads in BEVs. Demonstrated on a 2015 Fiat 500e BEV, this system integrates a semi-hermetic refrigeration loop with a coolant network and serves three functions: (1) heating and/or cooling vehicle traction components (battery, power electronics, and motor), (2) heating and cooling of the cabin, and (3) waste energy harvesting and re-use. The modes of operation allow a heat pump and air conditioning system to function without reversing the refrigeration cycle to improve thermal efficiency. The refrigeration loop consists of an electric compressor, a thermal expansion valve, a coolant-cooled condenser, and a chiller, the latter two exchanging heat with hot and cold coolant streams that may be directed to various components of the thermal system. The coolant-based heat distribution is adaptable and saves significant amounts of refrigerant per vehicle. Also, a coolant-based system reduces refrigerant emissions by requiring fewer refrigerant pipe joints. The authors present bench-level test data and simulation analysis and describe a preliminary control scheme for this system.

33 ADVANCED PROPULSION SYSTEMS↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (control-lable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Superconducting air core inductor systems and methods

Provided is a low-weight, high-efficiency inductor design for use with or in electrical power equipment, such as inverters. A toroidal power inductor includes a support structure comprising an outer shell, an inner shell, and one or more coolant channels formed therebetween, a plurality of conductors wrapped around and supported by an exterior surface of the outer shell, and an interior cavity substantially enclosed by the inner shell of the toroidal support structure. The plurality of conductors are configured to provide an inductance for the toroidal power inductor, and the one or more coolant channels are distributed beneath the exterior surface of the outer shell to cool the plurality of conductors. An air-core power inductor may implement the conductors using high-temperature superconducting (HTS) tapes cooled by cryogenic fluid flowing within the coolant channels.

42 ENGINEERING↗

Energetic Potential for Demand Response in Detached Single Family Homes in Austin, TX

This study builds a generalized tool to quantify the maximum peak load reduction achievable with residential demand response and distributed energy resources (DERs). The tool is demonstrated by using empirical energy usage data from detached single family households within the service territory of Austin Energy - the local municipal utility in Austin, TX. The demand response optimization algorithm shifts energy usage of four controllable, high-consumption residential devices to off-peak hours: HVAC (heating, ventilation, and air conditioning) systems, electric water heaters, electric vehicles, and pool pumps. In addition, rooftop solar generation on individual residences is considered to reduce net load to the utility, and an energy storage system optimization model performing energy arbitrage further reduces peak demand. Results from the aggregate demand response and battery optimization study indicate that peak demand for the 2017 summer peak in Austin Energy could have been reduced by 26 MW or 2.9%. Here, by considering the combined effect of controllable consumer loads, solar generation, and energy storage systems, this study highlights the potential of strategic demand response and energy arbitrage to reduce peak demand at the distribution level.

14 SOLAR ENERGY↗

Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts (Fact Sheet)

The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent). The original ventilation design for the project was provided by a local engineer and consisted of a single large heat recovery ventilator (HRV) located in a mechanical room in the basement with a centralized duct system providing supply air to the main living space and exhausting stale air from the single bathroom in each apartment. This design was deemed to be far too costly to install and operate for several reasons: the large central HRV was oversized and the specified flows to each apartment were much higher than the ASHRAE 62.2 rate; an extensive system of ductwork, smoke and fire dampers, and duct chases were specified; ductwork required a significant area of dropped ceilings; and the system lacked individual ventilation control in the apartments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Time-varying value of electric energy efficiency

Electric energy efficiency resources save energy and may reduce peak demand. Historically, quantification of energy efficiency benefits has largely focused on the economic value of energy savings during the first year and lifetime of the installed measures. Due in part to the lack of publicly available research on end-use load shapes (i.e., the hourly or seasonal timing of electricity savings) and energy savings shapes, consideration of the impact of energy efficiency on peak demand reduction (i.e., capacity savings) has been more limited. End-use load research and the hourly valuation of efficiency savings are used for a variety of electricity planning functions, including load forecasting, demand-side management and evaluation, capacity and demand response planning, long-term resource planning, renewable energy integration, assessing potential grid modernization investments, establishing rates and pricing, and customer service. This study reviews existing literature on the time-varying value of energy efficiency savings, provides examples in four geographically diverse locations of how consideration of the time-varying value of efficiency savings impacts the calculation of power system benefits, and identifies future research needs to enhance the consideration of the time-varying value of energy efficiency in cost-effectiveness screening analysis. Findings from this study include: -The time-varying value of individual energy efficiency measures varies across the locations studied because of the physical and operational characteristics of the individual utility system (e.g., summer or winter peaking, load factor, reserve margin) as well as the time periods during which savings from measures occur. -Across the four locations studied, some of the largest capacity benefits from energy efficiency are derived from the deferral of transmission and distribution system infrastructure upgrades. However, the deferred cost of such upgrades also exhibited the greatest range in value of all the components of avoided costs across the locations studied. -Of the five energy efficiency measures studied, those targeting residential air conditioning in summer-peaking electric systems have the most significant added value when the total time-varying value is considered. -The increased use of rooftop solar systems, storage, and demand response, and the addition of electric vehicles and other major new electricity-consuming end uses are anticipated to significantly alter the load shape of many utility systems in the future. Data used to estimate the impact of energy efficiency measures on electric system peak demands will need to be updated periodically to accurately reflect the value of savings as system load shapes change. -Publicly available components of electric system costs avoided through energy efficiency are not uniform across states and utilities. Inclusion or exclusion of these components and differences in their value affect estimates of the time-varying value of energy efficiency. -Publicly available data on end-use load and energy savings shapes are limited, are concentrated regionally, and should be expanded.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of nozzle lateral spacing on afterbody drag and performance of twin-jet afterbody models with cone plug nozzles at Mach numbers up to 2.20

Twin-jet afterbody models were investigated by using two balances to measure separately the thrust minus total drag and the afterbody drag at Mach numbers of 0.0 and 0.50 to 2.20 for a constant angle of attack of 0. Translating shroud cone plug nozzles were tested at dry and maximum afterburning power settings with a high-pressure air system used to provide jet total-pressure ratios up to 20.0. Two nozzle lateral spacings were studied by using afterbodies with several interfairing shapes. The close- and wide-spaced afterbodies had identical cross-sectional area distributions when similar interfairings were installed on each. Nozzle cant angles of -5, 0, and 5 degrees were investigated. The results show that the highest overall performance was generally obtained with the close-spaced afterbody, basic interfairings (no base), and uncanted nozzles.

Berrier, B. L.↗

Effect of nozzle lateral spacing, engine interfairing shape, and angle of attack on the performance of a twin-jet afterbody model with cone plug nozzles

Twin-jet afterbody models were investigated by using two balances to measure separately the thrust minus total axial force and the afterbody drag at Mach numbers from 0 to 1.3. Angle of attack was varied from minus 2 deg to 8.5 deg. Translating shroud cone plug nozzles were tested at dry-power and maximum-afterburning-power settings with a high-pressure air system used to provide jet total-pressure ratios up to 9.0. Two nozzle lateral spacings were studied by using afterbodies with several interfairing shapes. The close- and wide-spaced afterbodies had identical cross-sectional area distributions when similar interfairings were installed on each. The results show that the highest overall performance was obtained with the close-spaced afterbody and basic interfairings. Increasing angle of attack decreased performance for all configurations and conditions investigated.

Berrier, B. L.↗

Measurements in liquid fuel sprays

A ground test facility is being established at NASA Lewis Research Center to simulate the environmental and flight conditions needed to study adverse weather effects. One of the most important components is the water spray system which consists of many nozzles fitted on spray bars. Water is injected through air-assisted atomizers to generate uniform size drops to simulate icing in clouds. The primary objective is to provide experimental data on drop size distribution over a wide range of operating conditions. Correlation equations for mean drop size and initial injection parameters are being determined to assist in the design and modification of the Altitude Wind Tunnel. Special emphasis is being placed on the study of the aerodynamic structure of the air-assisted atomizer sprays. Detailed measurements of the variation of drop size distribution and velocity as a function of time and space are being made. Accurate initial and boundary conditions are being provided for computer model evaluation.

Chigier, N.↗

The structure of particle cloud premixed flames

The structure of premixed flames propagating in combustible systems containing uniformly distributed volatile fuel particles in an oxidizing gas mixture is analyzed. This analysis is motivated by experiments conducted at NASA Lewis Research Center on the structure of flames propagating in combustible mixtures of lycopodium particles and air. Several interesting modes of flame propagation were observed in these experiments depending on the number density and the initial size of the fuel particle. The experimental results show that steady flame propagation occurs even if the initial equivalence ratio of the combustible mixture based on the gaseous fuel available in the particles, phi sub u, is substantially larger than unity. A model is developed to explain these experimental observations. In the model, it is presumed that the fuel particles vaporize first to yield a gaseous fuel of known chemical composition which then reacts with oxygen in a one-step overall process. The activation energy of the chemical reaction is presumed to be large. The activation energy characterizing the kinetics of vaporization is also presumed to be large. The equations governing the structure of the flame were integrated numerically. It is shown that the interplay of vaporization kinetics and oxidation process can result in steady flame propagation in combustible mixtures where the value of phi sub u is substantially larger than unity. This prediction is in agreement with experimental observations.

Seshadri, K.↗

Development of a Free-Flight Simulation Infrastructure

In anticipation of a projected rise in demand for air transportation, NASA and the FAA are researching new air-traffic-management (ATM) concepts that fall under the paradigm known broadly as ":free flight". This paper documents the software development and engineering efforts in progress by Seagull Technology, to develop a free-flight simulation (FFSIM) that is intended to help NASA researchers test mature-state concepts for free flight, otherwise referred to in this paper as distributed air / ground traffic management (DAG TM). Under development is a distributed, human-in-the-loop simulation tool that is comprehensive in its consideration of current and envisioned communication, navigation and surveillance (CNS) components, and will allow evaluation of critical air and ground traffic management technologies from an overall systems perspective. The FFSIM infrastructure is designed to incorporate all three major components of the ATM triad: aircraft flight decks, air traffic control (ATC), and (eventually) airline operational control (AOC) centers.

Miles, Eric S.↗

Existing Whole-House Solutions Case Study: Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts

The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. In this project, Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent).

air barrier↗

Decommissioning of the Remediation Systems at Waverly, Nebraska, in 2011-2012

The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility in Waverly, Nebraska, from 1952 to 1974. During this time, the grain fumigant '80/20' (carbon tetrachloride/carbon disulfide) was used to preserve stored grain. In 1982, sampling by the U.S. Environmental Protection Agency (EPA) found carbon tetrachloride contamination in the town's groundwater. After an investigation of the contaminant distribution, the site was placed on the National Priority List (NPL) in 1986, and the CCC/USDA accepted responsibility for the contamination. An Interagency Compliance Agreement between the EPA and the CCC/USDA was finalized in May 1988 (EPA 1990). The EPA (Woodward-Clyde Consultants, contractor) started immediate cleanup efforts in 1987 with the installation of an air stripper, a soil vapor extraction system, a groundwater extraction well, and groundwater and soil gas monitoring wells (Woodward-Clyde 1986, 1988a,b). After the EPA issued its Record of Decision (ROD; EPA 1990), the CCC/USDA (Argonne National Laboratory, contractor) took over operation of the treatment systems. The CCC/USDA conducted a site investigation (Argonne 1991, 1992a,b), during which a carbon tetrachloride plume in groundwater was discovered northeast of the former facility. This plume was not being captured by the existing groundwater extraction system. The remediation system was modified in 1994 (Argonne 1993) with the installation of a second groundwater extraction well to contain the contamination further. Subsequently, a detailed evaluation of the system resulted in a recommendation to pump only the second well to conserve water in the aquifer (Argonne 1995). Sampling and analysis after implementation of this recommendation showed continued decreases in the extent and concentrations of the contamination with only one well pumping (Argonne 1999). The CCC/USDA issued quarterly monitoring reports from 1988 to 2009. Complete documentation of the CCC/USDA characterization and remediation efforts, including the quarterly monitoring reports, is on the compact disc inside the back cover of this report. The EPA reported on the progress of the remediation systems in a series of five-year reviews (EPA 1993, 1999, 2004, 2009). These reports and other EPA documentation are also on the compact disc inside the back cover of this report, along with the Woodward-Clyde (1986, 1988a,b) documentation cited. Starting in 2006, the analytical results for groundwater (the only medium still being monitored) showed no carbon tetrachloride concentrations above the maximum contaminant level (MCL) of 5.0 g/L. Because the cleanup goals specified in the ROD (EPA 1990) had been met, the EPA removed the site from the NPL in November 2006 (Appendix A). In 2008 the National Pollutant Discharge Elimination System (NPDES) permit for the remediation system was deactivated, and a year later the EPA released its fourth and final five-year report (EPA 2009), indicating that no further action was required for the site and that the site was ready for unlimited use. In 2011-2012, the CCC/USDA decommissioned the remediation systems at Waverly. This report documents the decommission process and closure of the site.

54 ENVIRONMENTAL SCIENCES↗