Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Agreements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Detecting flash drought events to inform adaptive water management

Abstract: Flash droughts are characterized by a rapid onset of drought conditions, a common feature among various indicators of these events. The lack of a standardized definition and indicator makes flash droughts particularly challenging to predict and manage. We test six state-of-the-art flash drought indicators using 41 years of daily data across all Hydrological Unit Code 4 (HUC4) regions in the contiguous United States. Our results show substantial disagreements among indicators, suggesting that the detection of a flash drought event strongly depends on the choice of indicator. From the perspective of informing management and operations, an open challenge remains: which flash drought indicator should be used to trigger operational adaptations? To this end, we propose a methodological framework that informs adaptive actions by regionally assessing the level of agreement between different indicators. The regional differences in hydroclimatic conditions are expected to be reflected in the level of agreement between indicators. To better inform adaptive actions, the framework will also consider the impacted sectoral water uses and their varying response times. The insights gained from this study improve the understanding of how these different flash drought indicators capture the different aspects of regional differences and impacted sectors. Furthermore, this information can support more targeted adaptive actions to mitigate adverse impacts through improved preparedness and response strategies.

climate resilience↗

Flash Drought indicators at catchment scale for CONUS

Flash droughts are defined by the rapid onset and intensification of drought conditions - a feature common across various proposed indicators. However, the absence of a standardized definition and detection method makes them particularly difficult to anticipate and manage. This dataset includes flash drought classifications based on six different methods across 222 catchments (4-digit Hydrologic Units, HUC4) in the Contiguous United States (CONUS) from 1983 to 2023. It also includes the pairwise agreement between indicators and the event-level multi-indicator agreement. For a detailed description of each file, refer to README_MSDlive.pdf

Catchment scale↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

SITCOMTN-165: Surface brightness profiles around massive galaxies in LSSTComCam data

Low surface brightness photometry of massive galaxies can probe the extended stellar halos and intracluster light but is often limited by background subtraction and masking systematics. Here we present radial surface brightness profiles for the brightest cluster galaxy of Abell 360 and 2dFGRS TGS323Z113 using Rubin Observatory Commissioning Camera (LSSTComCam) Data Preview 1 in the g, r, and z bands. Our results show that the LSSTComCam data can go down to ~28 mag arcsec^-2 in the r band. Comparison to DECaLS measurements processed with Legacyhalos shows good agreement of surface brightness profiles at small radii while the LSSTComCam data extend deeper at larger radii.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of methods for SARS-CoV-2 variant detection and abundance estimation within mixed population samples

The accurate identification of SARS-CoV-2 (SC2) variants and estimation of their abundance in mixed population samples (e.g., air or wastewater) is imperative for successful surveillance of community level trends. Assessing the performance of SC2 variant composition estimators (VCEs) should improve our confidence in public health decision making. Here, we introduce a linear regression based VCE and compare its performance to four other VCEs: two re-purposed DNA sequence read classifiers (Kallisto and Kraken2), a maximum-likelihood based method (Lineage deComposition for Sars-Cov-2 pooled samples (LCS)), and a regression based method (Freyja). We simulated DNA sequence datasets of known variant composition from both Illumina and Oxford Nanopore Technologies (ONT) platforms and assessed the performance of each VCE. We also evaluated VCEs performance using publicly available empirical wastewater samples collected for SC2 surveillance efforts. Bioinformatic analyses were performed with a custom NextFlow workflow (C-WAP, CFSAN Wastewater Analysis Pipeline). Relative root mean squared error (RRMSE) was used as a measure of performance with respect to the known abundance and concordance correlation coefficient (CCC) was used to measure agreement between pairs of estimators. Based on our results from simulated data, Kallisto was the most accurate estimator as it had the lowest RRMSE, followed by Freyja. Kallisto and Freyja had the most similar predictions, reflected by the highest CCC metrics. We also found that accuracy was platform and amplicon panel dependent. For example, the accuracy of Freyja was significantly higher with Illumina data compared to ONT data; performance of Kallisto was best with ARTICv4. However, when analyzing empirical data there was poor agreement among methods and variations in the number of variants detected (e.g., Freyja ARTICv4 had a mean of 2.2 variants while Kallisto ARTICv4 had a mean of 10.1 variants). This work provides an understanding of the differences in performance of a number of VCEs and how accurate they are in capturing the relative abundance of SC2 variants within a mixed sample (e.g., wastewater). Such information should help officials gauge the confidence they can have in such data for informing public health decisions.

60 APPLIED LIFE SCIENCES↗

Measurement of internal dark current in a 17 GHz accelerator structure with an elliptical sidewall

A 17 GHz single cell, standing wave, copper accelerator structure with an axisymmetric elliptical central cell sidewall was tested for internal and downstream dark current as a function of gradient up to 93 MV/m. The elliptical sidewall was predicted to suppress the internal dark current and the lower order multipactor modes as compared with a previously tested structure having a straight sidewall. During the conditioning phase of the elliptical sidewall structure, strong internal dark current generated by an N = 1 multipactor mode was observed at gradients in the 10 to 20 MV/m range. After conditioning with 2.2x10^5 pulses to 93 MV/m, the N = 1 mode was completely suppressed and no multipactor resonances were observed. The internal dark current was reduced to a comparatively low level, much smaller than in the previously studied, straight sidewall structure, in good agreement with simulations. The energy spectrum of the electrons colliding with the sidewall was measured using an isolated side dark current monitor and a bias voltage. As the conditioning progressed, the electron energy spectrum showed an increase in the concentration of lower energy electrons, also in good agreement with simulations. Studies of internal dark current may help to understand the rf conditioning and ultimate performance of high gradient accelerator structures.

43 PARTICLE ACCELERATORS↗

One and Two Dimensional Quantum Lattice Algorithms for Maxwell Equations in Inhomogeneous Scalar Dielectric Media. II: Simulations

Long time quantum lattice algorithm (QLA) simulations are performed for the mul- tiple reflection-transmission of an initial electromagnetic pulse propagating normally to a boundary layer region joining two media of different refractive index. For these one dimensional (1D) sim- ulations, there is excellent agreement between x-, y- and z- representations, as well as very good agreement with nearly all the standard plane wave boundary condition results for reflection and transmission off a dielectric discontinuity. In the QLA simulation, no boundary conditions are im- posed at the continuous, but sharply increasing, dielectic boundary layers. Two dimensional (2D) QLA scattering simulations in the x-z plane are performed for an electromagnetic pulse interacting with a conical dielectric obstacle for the 8-16 qubit model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Idaho National Laboratory Advanced Reactor Technologies Quality Assurance Program Plan

This QAPP covers INL ART R&D, licensing, and program support activities. QA implementing procedures will be identified for all activities to ensure work is documented and the results are capable of successfully completing a technical review by DOE. For work performed by other organizations under contract or other agreements with INL, applicable requirements will be flowed down through the contract or other agreements, but the organizations will be responsible to implement the flowed down requirements through their own specific implementing procedures. This QAPP also covers implementation of software QA (SQA) requirements for software used exclusively by INL ART. Software that is used to support multiple INL programs/projects is not covered by this QAPP; the responsibility for implementing SQA requirements for that software resides with the owners and respective managers of the software. This QAPP does not cover activities for installing and operating experiments in the Advanced Test Reactor (ATR) at INL, nor does it cover ATR facility modifications designed to meet INL ART testing needs (such as temperature, pressure, gas flow, and control systems). Those activities are controlled by the INL QAP and specific ATR implementing procedures. ATR facility management and INL ART management jointly approve experiment designs and functional system requirements. This QAPP does apply to INL ART R&D experiments that will be inserted into ATR and any support activities associated with those R&D activities. This QAPP does not cover activities for installing and operating general post irradiation examination (PIE) test equipment in Materials and Fuels Complex (MFC) facilities. Those activities are controlled by the INL QAP and MFC implementing procedures. However, this QAPP does apply to MFC facility modifications designed to meet specific INL ART testing needs. It also applies to INL ART experiments that will have PIE performed on them and any support activities associated with the PIE activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

How Local Governments Can Buy Renewable Energy and Support Market Development

This webinar covers strategies local governments can consider to procure renewable energy and support renewable energy market development, including power purchase agreements (PPAs), virtual power purchase agreements (VPPAs), community solar, and more. This webinar also covers how the regulatory landscape impacts the RE purchasing options available to a particular community and highlight case studies from local governments across the U.S. that have successfully implemented these strategies, including Arlington, Virginia and Denver, Colorado. This webinar provides one AICP CM continuing education credit. Who: Chad Laurent, Esq., Principal, Cadmus Group; Jonathan Rogers, Renewable Energy Specialist, Office of Climate Action, Sustainability, Resiliency at the City and County of Denver; John Morrill, Energy Manager, Office of Sustainability & Environmental Management, Arlington County Department of Environmental Services

14 SOLAR ENERGY↗

Safeguards Technical Objectives for Thorium Molten Salt Reactor Fuel Cycles

China, Denmark, France, India, Indonesia, the United Kingdom, and the United States, among others, are exploring commercial thorium fuel cycles for domestic power production and/or international export. For any thorium fuel cycle facilities built and/or operated in a non-nuclear weapon State with a comprehensive safeguards agreement, those facilities and any associated nuclear material would be subject to international nuclear safeguards by the International Atomic Energy Agency (IAEA). Thorium fuel cycle facilities offered for the application of safeguards under a voluntary offer agreement by a nuclear weapon State would also be subject to safeguards, if selected by the IAEA. Compared to uranium/plutonium fuel cycle facilities, thorium fuel cycle facilities are comparatively diverse from an inspection and accounting perspective, differing greatly in material type, form, and design from uranium/plutonium fuel cycle facilities and also from each other. Of these, the most complex thorium fuel cycles – and therefore likely the most challenging to the implementation of international nuclear safeguards – are those that include thorium molten salt reactors. With thorium fuel cycles approaching near-term commercial deployment timelines, it is imperative that the international nuclear safeguards community begins to think about how to adapt existing international nuclear safeguards concepts and approaches to thorium fuel cycles, as well as mitigate any gaps that may exist. This paper focuses on the development of recommended safeguards technical objectives for efficient and effective application of international nuclear safeguards measures (e.g., containment / surveillance, non-destructive assay, destructive assay, environmental sampling) to thorium molten salt reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation Efforts of an Open-Source Aeroacoustics Model for Wind Turbines: Preprint

The open source aeroservoelastic wind turbine solver, OpenFAST, now includes an aeroacoustics model, which is described here and validated against experimental measurements recorded on a GE 1.5-MW wind turbine installed at the Flatirons Campus of the National Renewable Energy Laboratory in Boulder, Colorado. The validation demonstrates satisfactory agreement between numerical predictions and experimental recordings, with discrepancies up to 7 dB in the overall sound pressure levels at low wind speeds and a better agreement around the rated wind speed of the turbine.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Influence of NOx Chemistry on the Prediction of Natural Gas End-Gas Autoignition

Research on the influence of NOx (NO/NO2) chemistry on HC oxidation has shown that NOx plays an important role in the promotion/inhibition of HC autoignition [1-6]. Current data for n-heptane, iso-octane, ethanol, and toluene [3, 4] have shown that NO chemistry inhibits autoignition at low temperatures and concentrations. However, at medium and high temperatures and low concentrations, autoignition is promoted, decreasing the Negative Temperature Coefficient (NTC) effect. This autoignition promotion, however, becomes weaker as NO concentrations are increased. Additionally, fundamental kinetics studies have suggested that NOx chemistry also promotes the autoignition of smaller HC, such as CH4 [7-10], C2H6 [11-14], and C3H8 [15]. Additionally to the chemical kinetics studies, a growing body of evidence supports the importance of NOx chemistry on SI engine simulations [16, 17]. Foong et al. [18] suggested that the addition of NO in their models significantly improved the agreement between simulations and experiments where the onset of knock was advanced due to the presence of NO, and Morganti et al. [19] showed that NO addition in the residual-gas was necessary for their models to obtain good agreement with experimental data. Lastly, Mohr et al. [20, 21] investigated the effect of Natural Gas (NG) reactivity and EGR substitution rate and composition on homogeneous ignition delay, flame speeds, and EGAI for stoichiometric NG/oxidizer/EGR blends. They observed that the addition of EGR composed of only inert species (CO2 and Ar) suppressed homogeneous autoignition in all NG fuels tested under all conditions. However, for all NG fuels tested, increasing EGR rates with reactive species (Ar, CO2, CO, and NO) promoted homogeneous autoignition under all conditions, thus reproducing the same trends for various NG fuel compositions that were observed in other studies and fuels. For this reason, a study is being conducted to analyze the effects of NOx chemistry on the prediction of NG/air/EGR homogeneous autoignition. This study has been divided into two tasks. First, the addition of NOx chemistry to the ARIES82 mechanism [20] is being validated using homogeneous ignition delay data collected by Mohr [20, 21]. Second, once the new modified mechanism with NOx reactions has been validated, it will be employed on engine multi-dimensional modeling presented in [22, 23] to analyze the influence of NOx chemistry on NG EGAI. Results thus far have shown that homogeneous ignition delay calculations are sensitive to NOx chemistry, where the modified mechanisms captured well all trends and closely matched the homogeneous ignition delays observed by Mohr et al. Also, the results in this work suggest that NOx chemistry is necessary to correctly capture the trends in NG homogeneous autoignition when EGR with reactive species is used since the opposite behavior is observed when only inert species are considered for the EGR composition.

03 NATURAL GAS↗

CLOSURE REPORT FOR CORRECTIVE ACTION UNIT 577 AREA 5 CHROMIUM CONTAINING WASTE DISPOSAL CELLS

Report will be submitted to the state of Nevada Corrective Action Unit (CAU) 577, “Area 5 Chromium Containing Waste Disposal Cells,” includes five low-level waste cells at the Nevada National Security Site (NNSS) Area 5 Radioactive Waste Management Site (RWMS) where buried waste received from Nuclear Fuel Services, Inc. (NFS), was subsequently determined to contain chromium that exceeded the Toxicity Characteristic Leaching Procedure regulatory limit, which would require the waste to carry hazardous waste code D007. CAU 577 was created to satisfy the requirements of the Settlement Agreement (SA) executed between the Nevada Division of Environmental Protection (NDEP) and the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office on April 25, 2019. The SA required that the chromium-containing waste received from NFS would be addressed following the closure process laid out in the Federal Facility Agreement and Consent Order (FFACO). The FFACO process ensures proper closure of the chromium-containing waste cells and documentation of that closure through FFACO-type documents (NDEP 2019). As stipulated in Paragraph 5C of the SA, a Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) was prepared that identified and evaluated risks and corrective action alternatives (CAAs) for CAU 577, provided the plan for implementing the recommended CAA, and presented the post-closure plan (U.S. Department of Energy [DOE] Environmental Management [EM] Nevada Program 2021).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Photoproduction of the b 1 (1235) Meson off the proton at E gamma = 6-12 GeV

The GlueX Experiment at Jefferson Lab directs a linearly polarized photon beam on a liquid hydrogen target surrounded by an almost hermetic detector. The experiment aims to study the meson spectrum in the light-quark sector and search for exotic spin-parity states predicted by lattice QCD calculations. The lightest exotic candidate is the π 1 meson, which is predicted to decay dominantly to b 1 π. In this thesis, we present efforts to characterize the ωπ 0 decay channel of the b 1 meson as precursor to an analysis of the sought-after π 1 exotic state. We present an introduction to the physics involved and an overview of the detector subsystems with a focus on the Barrel Calorimeter gain monitoring system, as part of the service work expected by the GlueX Collaboration. We discuss the data analysis method used and present two frameworks, for angular moments and partial waves analyses. Details of the simulation used to calculate the detector acceptance. A proof of concept partial wave analysis is presented along with experimental angular moments as first step to a full analysis of the angular distribution Our partial wave analysis indicates that both S- and D-waves are needed, in qualitative agreement with theoretical expectations. The cross-section of the omega π 0 channel is extracted to be of the scale of 1 μb in agreement with previous measurements. The differential cross-section indicates the presence of two production processes with p 1 = -5:24 ± 0:04 for 0:25 < -t < 0:95 GeV 2 ~c 2 and p 2 = -1:24 ± 0:05 for 0:95 < -t < 2:0 GeV 2 ~c 2 , which does not agree with results from previous experiments. The s-channel helicity conservation and helicity amplitudes of the b 1 meson are presented as additional experimental observables. Our results confirm that the b1 photoproduction process does not conserve s-channel helicity though they do not align with previous measurements. The helicity amplitude of the omega are extracted to be |F 1 | 2 = 0:3037 ± 0:0003 which does not agree with the expected value of a b 1 decay or results from a previous experiment. Future steps in all these analyses will be continued by a new graduate student in the group, culminating in a publication.

Foda, Ahmed↗

First Observation of Large Missing-Momentum (e,e&#x27;p) Cross-Section Scaling and the onset of Correlated-Pair Dominance in Nuclei

We report the first measurement of $x_B$-scaling in $(e,e'p)$ cross-section ratios off nuclei relative to deuterium at large missing-momentum of $350 \leq p_{miss} \leq 600$ MeV/c. The observed scaling extends over a kinematic range of $0.7 \leq x_B \leq 1.8$, which is significantly wider than $1.4 \leq x_B \leq 1.8$ previously observed for inclusive $(e,e')$ cross-section ratios. The $x_B$-integrated cross-section ratios become constant (i.e., scale) beginning at $p_{miss}\approx k_F$, the nuclear Fermi momentum. Comparing with theoretical calculations we find good agreement with Generalized Contact Formalism calculations for high missing-momentum ($> 375$ MeV/c), suggesting the observed scaling results from interacting with nucleons in short-range correlated (SRC) pairs. For low missing-momenta, mean-field calculations show good agreement with the data for $p_{miss}\le k_F$, and suggest that contributions to the measured cross-section ratios from scattering off single, un-correlated, nucleons are non-negligible up to $p_{miss}\approx 350$ MeV/c. Therefore, SRCs become dominant in nuclei at $p_{miss}\approx 350$ MeV/c, well above the nuclear Fermi Surface of $k_F \approx 250$ MeV/c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MODELING AND PARAMETRIC STUDY OF END-GAS AUTOIGNITION TO ALLOW THE REALIZATION OF ULTRA-LOW EMISSIONS, HIGH-EFFICIENCY HEAVY-DUTY SPARK-IGNITED NATURAL GAS ENGINES

Engine knock and misfire are barriers to pathways leading to high-efficiency Spark-Ignited (SI) Natural Gas (NG) engines. The general tendency to knock is highly dependent on engine operating conditions and the fuel reactivity. The problem is further complicated by the low emission limits and the wide range of chemical reactivity in pipeline-quality natural gas. Depending on the region and the source of the natural gas, its reactivity, described by its Methane Number (MN), which is analogous to the Octane Number for liquid SI fuels, can span from 65 to 95. In order to realize diesel-like efficiencies, SI NG engines must be designed to operate at high Brake Mean Effective Pressures (BMEP), near or beyond knock limits, over a wide range of fuel reactivity. This requires a deep understanding of the combustion-engine interactions pertaining to flame propagation and End-Gas Autoignition (EGAI), i.e., the autoignition of the unburned gas (end gas) ahead of the flame front. However, EGAI, if controlled, provides an opportunity to increase SI NG engine efficiency by increasing the combustion rate and the total fraction of burned fuel, mitigating the effects of the slow flame speeds characteristic of natural gas fuels, which generally reduce BMEP and increase unburned hydrocarbon emissions. For this reason, to realize diesel-like efficiencies and ultra-low emissions on SI NG engines, this work proposes the study of the main parameters influencing the modeling and prediction of NG EGAI to allow for its control. In this work, a novel EGAI detection and onset determination method was developed to reliably quantify EGAI for data analysis and engine control. The new method allowed the prediction of EGAI on SI NG engines without the need to use engine- and operating-condition-dependent thresholds and reduced the error in quantifying the fraction of the total energy released by the EGAI event by up to 40%pts. One- and three-dimensional engine models were then developed to study the engine/fuel interactions that lead to NG EGAI and its performance benefits. These models, although having decent agreement with experimental data, showed the need to account for NOx chemistry when predicting NG EGAI due to a consistently later prediction of the EGAI onset (~1.65 crank-angle degrees) and thus, a new reduced chemical mechanism for real NG fuels was developed containing NOx chemistry. The new reduced mechanism improved the EGAI onset prediction agreement to within ±0.5 crank-angle degrees and decreased simulation time during combustion by nearly 50% when using the further reduced AREIS50NOx chemical mechanism. These models were then used to study the role of NG composition on EGAI, evaluate the engine/fuel interactions leading to NG EGAI, and perform engine optimization while leveraging EGAI to increase thermal efficiency. Piston design optimization combined with a Controlled EGAI (C-EGAI) combustion mode allowed a Heavy-Duty (HD) SI NG engine to operate at diesel-like efficiencies, i.e., Brake Thermal Efficiency (BTE) ≥44%. Experimental and modeling data analysis revealed that earlier and faster heat release increases combustion efficiency by an average of 1%pts, increases work transferred to the piston resulting in a decrease in exhaust losses by 50% depending on the engine operating condition while slightly increasing heat losses. Finally, the simulation results revealed an opportunity to further enhance the BTE (up to 50%) by enabling C-EGAI combustion at leaner conditions, λ=1.4-1.6.

Bestel, Diego Bernardi↗