Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Aging analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Development of an In-Situ Method for Cable Condition Monitoring in Nuclear Power Plants (SBIR Phase IIB Final Report)

This is the final report of a Small Business Innovation Research (SBIR) project that Analysis and Measurement Services Corporation (AMS) has conducted for the U.S. Department of Energy (DOE) over a seven-and-a-half year period (February 2013 through April 2020 with the awards of Phase I, Phase II and Phase IIB projects). The goal of the project was to design, develop, validate, and demonstrate a technique for in-situ testing of cable insulation polymers that will identify, locate, and provide the degree of aging for cables commonly used in nuclear power plants. During the Phase I project, AMS established that the frequency domain reflectometry (FDR) technique can successfully identify and measure cable insulation degradation that can be trended with aging. In Phase II, AMS performed extensive cable aging studies to correlate FDR measurements with other laboratory condition monitoring techniques and developed aging condition categories to quantify the severity of insulation degradation. In Phase IIB, the project expanded the research to include a wider variety of cable polymers that are used in the commercial nuclear power industry. This work also involved developing acceptance criteria to objectively assess age-related cable degradation while sharing the results of this research with industry, academia, and national laboratories to advance the state of the art in cable aging management technologies. The products developed under this research project provide the nuclear industry with an effective condition monitoring tool to support safe and long-term plant operation. Throughout the project, collaborations and support were received from a variety of industry organizations and individuals including DOE National Laboratories as well as nuclear plant utilities and several other industry experts and cable manufacturers. Contributions from these organizations included the donation of new cables, naturally aged cables, and research collaboration. The validation and commercialization of the products of this project were achieved through opportunities to test and demonstrate the technologies’ capabilities on-site at nuclear power generation and research facilities as well as in the laboratory alongside industry peers and cable testing service companies. The research resulted in a technology that can be used to identify, locate, and quantify age-related degradation in several types of cable polymers. This included developing software and hardware as well as the methodology for using the FDR technique to assess age-related degradation of installed cables. The technology developed under this project can provide nuclear plant management, engineers, and technicians with an in-situ electrical test method to determine if in-service cables need to be replaced, monitored on a periodic basis, or show no evidence of significant age-related degradation that may require action. Near the end of this Phase IIB project, the FDR product was sold to a nuclear power utility in South Korea. This sale of a dedicated aging assessment tool is the beginning of a comprehensive contract with the expectation of twelve (12) units sold to that country. Additionally, the FDR technology has been sold to several industry organizations including a nuclear research institute and the Diablo Canyon nuclear power plant. This technology is also being leased by other nuclear industry service companies for incorporation into aging management programs. The cable testing technology that was developed under this project was also integrated into a comprehensive cable aging assessment service that is being offered to the nuclear industry at the request of U.S. nuclear utilities and is currently part of onsite testing services provided by AMS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Network Models of Active Degradation Mechanisms and Pathways for Service Life Prediction of Indoor and Outdoor PV Modules

ct: PV service lifetime prediction (SLP) enables accurate calculation of levelized cost of energy (LCOE), which is crucial to rationalizing PV investment and installation. However, SLP is challeging since PV reliability in the field is affected by many combined factors, including various environmental stresses and module quality. In order to map out the active degradation mechanisms and pathways that best resemble real world conditions, we introduce the framework of a study protocol and use network models fitted to data, to enable analysis and SLP of complex PV systems with multiple active degradation mechanisms. The study protocol is the experimental design, including module variants and different exposure conditions, selection of evaluation methods, time-series data acquisition and training of network models to these data. We present SLP of minimodules in the lab and PV systems in the field. For lab SLP, minimodules with 8 variants based on manufacturer, architecture, and encapsulation were prepared and aged in modified damp heat with or without full spectrum light exposure. Stepwise I-V and Suns-Voc data acquisition tracks changes in electrical properties including Rs,IV, Isc,IV, Vmp,PIV providing insights into power loss of minimodules. Network structural equation modeling (netSEM) was utilized to construct degradation pathway models that identify active degradation mechanisms and predict power loss over time. For field SLP, datastreams of Pmp values and I-V curve datastreams of two types of modules installed in three distinctly different Köppen-Geiger climate zones for 9 years were acquired. With power loss modes corresponding to uniform current loss (ΔPIsc), recombination (ΔPVoc), series resistance (ΔPRs), and current mismatch (ΔPImis) determined, the performance loss rates (PLR) were determined using PVplr. We show how to establish a study protocol framework to ensure appropriate parametric variations and valid data collection from the variants of your complex systems. Then the data-driven netSEM model fitting provides a comprehensive mapping of multiple active degradation mechanisms, and accurate service life prediction.

network model, degradation, photovoltaic, solar↗

Early Embolization After Carotid Artery Stenting with Mesh-Covered Stent: Role of Diffusion-Weighted Magnetic Resonance Imaging as Pre-procedural Predictor and Discriminant Between Intra- and Post-procedural Events

Objectives: To evaluate the incidence and the time of onset of early micro-embolism after CAS (carotid artery stenting) with two different mesh-covered stents and to assess the role of DW-MRI (Diffusion-weighted magnetic resonance imaging) in their prediction. Methods: Single-institution prospective study including 50 patients (33 male, median age 74 years) who underwent CAS with Roadsaver{sup ®} or CGuard™. All patients with primary stenosis (37/50, 74%) had carotid plaque DW-MRI pre-procedure, with both qualitative evaluation of the hyperintensity and ADC (apparent diffusion coefficient) measurement of the plaque. All patients had brain DW-MRI pre-procedure, at 1 h, 24 h and 30 days post-procedure to evaluate the appearance of hyperintense lesions over time. Imaging analysis was performed in a double-blinded fashion by two radiologists. Results: There were no statistically significant differences between the two stents both in the incidence at 1 h (P = 0.23) and 24 h (P = 0.36) and in the volume of new DWI hyperintense brain lesions at 24 h (P = 0.27). Thirty-four new asymptomatic lesions in 19 patients (38%) were reported: 4 (11.8%) at 1 h, 30 (88.2%) at 24 h. The 30-day DWI-MR showed complete resolution of all lesions and no evidence of new lesion. The incidence of new lesions at 24 h resulted significantly higher in patients with DWI hyperintense carotid plaques (12/16, 75% vs. 0/21, 0%, P < 0.0001). This result was paralleled by the difference in ADC value (0.83 ± 0.21 vs. 1.42 ± 0.52). Conclusion: The majority of early asymptomatic brain lesion occurred during the first 24 h after CAS. Pre-procedure high DWI signal of the plaque was associated with an increased incidence of post-procedure microembolizations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemical Diversity of Oligomers in Biomass Fast Pyrolysis Oils, Part 2: Heavy Lignin-Derived Molecules and Highly Dehydrated Sugars from Dichloromethane-Insoluble Pyrolytic Lignin

Here, this paper, the second in a series, investigates the water-insoluble, dichloromethane (DCM)-insoluble residue of BTG pyrolysis oil, also known in the literature as high-molecular-weight pyrolytic lignin (HMW-PL). HMW-PL accounts for 9.2 wt % of the original bio-oil, which is known to increase upon aging and contribute to coke formation during bio-oil upgrading. Understanding its composition is crucial for managing pyrolysis oil during the processing. The HMW-PL was fractionated using a silica gel column with solvents of increasing polarity: ethyl acetate (EA), acetone (AC), isopropanol (ISO), and methanol (MeOH), yielding 49.2, 19.9, 8.2, and 8.1 wt %, respectively. Each subfraction was characterized by UV-fluorescence, FTIR, HSQC NMR, and (−)APCI-FT-Orbitrap MS. Analysis revealed that the EA subfraction primarily contained aromatic dimers (C 19 –C 20 ) and trimers (C 17 –C 13 ), while the MeOH subfraction was rich in oxygenated aliphatic monomers (C 8 –C 16 ) likely derived from sugar dehydration products. The resulting fractions were further separated via preparatory HPLC. Fifty-five candidate molecular structures were proposed based on the Orbitrap MS data, supported by UV-fluorescence, FTIR, and NMR results. This fractionation strategy defined four distinct subfractions, enabling the proposal of surrogate molecular structures and advancing the molecular-level understanding of the HMW-PL fraction in the pyrolysis bio-oil.

High-Molecular-Weight PL↗

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics↗

Evidence for ground-state electron capture of K 40

Potassium-40 is a widespread, naturally occurring isotope whose radioactivity impacts estimated geological ages spanning billions of years, nuclear structure theory, and subatomic rare-event searches—including those for dark matter and neutrinoless double-beta decay. The decays of this long-lived isotope must be precisely known for its use as a geochronometer, and to account for its presence in low-background experiments. There are several known decay modes for potassium-40, but a predicted electron-capture decay directly to the ground state of argon-40 has never been observed. The existence of this decay mode impacts several fields, while theoretical predictions span an order of magnitude. Here we report on the first, successful observation of this rare decay mode, obtained by the KDK (potassium decay) Collaboration using a novel combination of a low-threshold x-ray detector surrounded by a tonne-scale, high-efficiency γ -ray tagger at Oak Ridge National Laboratory. A blinded analysis reveals a distinctly nonzero ratio of intensities of ground-state electron-captures ( I EC 0 ) over excited-state ones ( I EC * ) of I EC 0 / I EC * = 0.0095 ± stat 0.0022 ± sys 0.0010 (68% CL), with the null hypothesis rejected at 4 σ [Stukel et al. , Phys. Rev. Lett. 131 , 052503 (2023) ]. In terms of branching ratio, this unambiguous signal yields I EC 0 = 0.098 % ± stat 0.023 % ± sys 0.010 % , roughly half of the commonly used prediction. This first observation of a third-forbidden unique electron capture improves our understanding of low-energy backgrounds in dark-matter searches and has implications for nuclear-structure calculations. For example, a shell-model based theoretical estimate for the neutrinoless double-beta decay half-life of calcium-48 is increased by a factor of 7 - 2 + 3 . Our nonzero measurement shifts geochronological ages by up to a percent; implications are illustrated for Earth and solar system chronologies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Surgical Management of the Axilla in Clinically Node-Positive Patients Receiving Neoadjuvant Chemotherapy: A National Cancer Database Analysis

Background: The feasibility of sentinel lymph node biopsy (SLNB) in patients with clinically node-positive (cN+) disease who convert to clinically node-negative (cN0) disease following neoadjuvant chemotherapy (NAC) has been evaluated in several large clinical trials, but it remains unclear whether the approach has been broadly adopted in the United States. Methods: The National Cancer Database was used to identify women diagnosed with cN+ breast cancer who received NAC followed by surgery between 2012 and 2015. Trends in axillary surgery were evaluated and multivariable logistic regression analyses performed to determine factors associated with receipt of SLNB. Results: Of 12,965 women cN+ at baseline, the use of SLNB increased from 31.8% in 2012 to 49% in 2015 (p < 0.001). Using axillary pCR as a surrogate for patients who convert to cN0 following NAC, among 5127 (39.5%) ypN0 patients, SLNB increased from 38.2 to 58.4% over the study period (p < 0.001), resulting in avoidance of axillary dissection in 42.2% of ypN0 patients by 2015. In adjusted analyses, factors significantly associated with SLNB attempt included cN1 disease, age < 45 years, treatment facility type, triple-negative and HER2-positive subtypes, and year of diagnosis. In women with residual isolated tumor cells (ITCs), micrometastases, and ypN1 disease, SLNB was the only axillary procedure performed in 36.9%, 23.6%, and 13.0% of cases. Conclusions: The use of SLNB in cN+ patients receiving NAC increased significantly between 2012 and 2015. SLNB alone was performed in more than 10% of patients with ypN1 disease, 20% with micrometastases, and 35% with ITCs; the oncologic safety of omitting axillary dissection in these patients requires further evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The K2 Galactic Archaeology Program Data Release 3: Age-abundance Patterns in C1–C8 and C10–C18

We present the third and final data release of the K2 Galactic Archaeology Program (K2 GAP) for Campaigns C1–C8 and C10–C18. We provide asteroseismic radius and mass coefficients, κ R and κ M , for ~19,000 red giant stars, which translate directly to radius and mass given a temperature. As such, K2 GAP DR3 represents the largest asteroseismic sample in the literature to date. K2 GAP DR3 stellar parameters are calibrated to be on an absolute parallactic scale based on Gaia DR2, with red giant branch and red clump evolutionary state classifications provided via a machine-learning approach. Combining these stellar parameters with GALAH DR3 spectroscopy, we determine asteroseismic ages with precisions of ~20%–30% and compare age-abundance relations to Galactic chemical evolution models among both low- and high-α populations for α, light, iron-peak, and neutron-capture elements. We confirm recent indications in the literature of both increased Ba production at late Galactic times as well as significant contributions to r-process enrichment from prompt sources associated with, e.g., core-collapse supernovae. With an eye toward other Galactic archeology applications, we characterize K2 GAP DR3 uncertainties and completeness using injection tests, suggesting that K2 GAP DR3 is largely unbiased in mass/age, with uncertainties of 2.9% (stat.) ± 0.1% (syst.) and 6.7% (stat.) ± 0.3% (syst.) in κ R and κ M for red giant branch stars and 4.7% (stat.) ± 0.3% (syst.) and 11% (stat.) ± 0.9% (syst.) for red clump stars. We also identify percent-level asteroseismic systematics, which are likely related to the time baseline of the underlying data, and which therefore should be considered in TESS asteroseismic analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

DAISY Complement Protein ML-Ready Data

A total of 172 children from the DAISY study with multiple plasma samples collected over time, with up to 23 years of follow-up, were characterized via proteomics analysis. Of the children there were 40 controls and 132 cases. All 132 cases had measurements across time relative to IA. Sampling was not consistent for all children. There were 47 of the children who had samples taken and evaluated prior to IA (Pre-IA), and 131 children had measurements at or after IA, but prior to diagnosis of clinical T1D (Post-IA). The control children were frequency matched on HLA genotypes and age and sex with an observed lower frequency of first degree relatives within the control group versus the cases For machine learning the children that will develop islet autoantibodies the 40 control and 47 Pre-IA children were down-selected to a single sample time point. For the 40 control children this was the earliest sample collected and for the 47 Pre-IA children it was a random selection of the first or second time point prior to the detection of autoantibodies to assure the age distributions were not significantly different.

machine learning, proteomics, Type 1 Diabetes, com↗

DAISY Complement Protein ML-Ready Data

A total of 172 children from the DAISY study with multiple plasma samples collected over time, with up to 23 years of follow-up, were characterized via proteomics analysis. Of the children there were 40 controls and 132 cases. All 132 cases had measurements across time relative to IA. Sampling was not consistent for all children. There were 47 of the children who had samples taken and evaluated prior to IA (Pre-IA), and 131 children had measurements at or after IA, but prior to diagnosis of clinical T1D (Post-IA). The control children were frequency matched on HLA genotypes and age and sex with an observed lower frequency of first degree relatives within the control group versus the cases For machine learning the children that will develop islet autoantibodies the 40 control and 47 Pre-IA children were down-selected to a single sample time point. For the 40 control children this was the earliest sample collected and for the 47 Pre-IA children it was a random selection of the first or second time point prior to the detection of autoantibodies to assure the age distributions were not significantly different.

Webb-Robertson, Bobbie-Jo M↗

Extreme Fast Charging of Lithium-Ion Battery: Understanding Bottlenecks and Safety Issues

Currently, graphite-based lithium-ion battery (LIB) packs in the electric vehicle (EV) domain can accommodate a charging rate up to 2C, which translates into a 0.5 to 1h recharge time [1-2]. Reducing the recharge time down to 10-15 min range would reduce the gap between the internal combustion engine’s refueling time and EV’s recharge time. Minimizing this gap is seen as attractive to consumers and would eventually enhance the adoption of EVs [1-3]. Significant research activity has been going on globally to understand the scientific limitations associated with high rate charging [4-6]. Extreme fast charging (XFC) of Li-ion batteries can create LIB life and safety issues [1, 7]. Among the issues are shortened battery life and enhanced safety concerns due to potential short creation by Li dendrites [1-2]. The detection and monitoring of Li plating onset and evolution over aging is a significant challenge. In-operando detection schemes to understand the dynamics of Li plating and the role that aging has on Li plating are vital to enable fast charging of specific energy cells. A key to the effort would be understanding the interplay between materials, electrode structure, and use conditions. This presentation will discuss the key bottlenecks of aggressive fast charging (~10 min). In particular, how extreme fast charging impacts individual battery components as well as the overall battery’s performance, life, and safety will be presented in light of experimental results and analysis. The effectiveness and challenges of in-operando electrochemical detection methods in aggressive charging conditions shall also be discussed. References [1] S. Ahmed, I. Bloom, A. N. Jansen, T. R. Tanim, E. J. Dufek, A. Pesaran, A. Burnham, R. B. Carlson, F. Dias, K. Hardy,M. Keyser, C. Kreuzer, A. Markel, A. Meintz, C. Michelbacher, M. Mohanpurkar, P. A. Nelson, D. C. Robertson, D. Scoffield,M. Shirk, T. Stephens, R. Vijayagopal, J. Zhang, Enabling fast charging–A battery technology gap assessment, J Power Sources,367 (2017), 250-262 [2] T.R. Tanim, M. G. Shirk, R. L. Bewley, E. J. Dufek, B. Y. Liaw, Fast charge implications: Pack and cell analysis and comparison,, J Power Sources, 381 (2018) 56-65 [3] N. Lutsey, S. Searle, S. Chambliss, and A. Bandivadekar, Assessment of leading electric vehicle promotion activities inUnited States cities, International Council on Clean Transportation, July 2015 [4] C. Michelbacher, S. Ahmed, I. Bloom, A. Burnham, B. Carlson, F. Dias, E. J. Dufek, A. N Jansen, M. Keyser, A. Markel,A. Meintz, M. Mohanpurkar, A. Pesaran, D. Scoffield, M. Shirk, T. Stephens, T. R. Tanim, R. Vijayagopal, J. Zhang, Enablingfast charging–Introduction and overview, J Power Sources, [5] E-Mobility: New Possibilities with 800-volt charging, Porsche newsroom, https://newsroom.porsche.com/en/technology/porsche-engineering-e-power-electromobility-800-volt-charging-12720.html(accessed Sep 2017) [6] Charging interface initiative e.V. - Industry statement on future charging infrastructure, available at: http://www.charinev.org/fileadmin/Downloads/Papers_and_Regulations/CharIN_industry_statement.pdf(accessed June 2017) [7] T. Waldmann, B. Hogg,M. Kasper, S. Grolleau, C. Couceiro, K. Trad, B. P. Matadi and M. Wohlfahrt-Mehrens, Interplay ofOperational Parameters on Lithium Deposition in Lithium-Ion Cells: Systematic Measurements with Reconstructed 3-ElectrodePouch Full Cells, J. Electrochem. Soc. 163 (7) (2016) A1232-A1238

25 ENERGY STORAGE↗

Normative Ranges for Oculomotor and Reaction Time Tests in U.S. Military Service Members and Veterans

AbstractBackground Oculomotor and reaction time tests are frequently used assessments of vestibular symptoms, traumatic brain injury (TBI), or other neurological disorders in both clinical and research contexts. When interpreting these tests it is important to have a reference interval (RI) as a comparison for what constitutes a typical/expected response; however, the current body of research has only limited information regarding normative ranges calculated according to established standards or for a military-specific sample.Purpose The purpose of the present study was to describe RIs for oculomotor and reaction time tests in a cohort of service members and veterans (SMVs) for use as comparators by clinicians and scientists.Research Design Descriptive.Study Sample Participants were prospectively enrolled in the Defense and Veterans Brain Injury Center-Traumatic Brain Injury Center of Excellence 15-year Longitudinal Traumatic Brain Injury Study. Only SMVs without a history of TBI or blast exposure were included in the RI calculations.Data Collection and Analysis The test paradigms included in this analysis were: smooth pursuit, prosaccades, antisaccades, saccades and reaction time, predictive saccades, optokinetic nystagmus, auditory reaction time, and visual reaction time. Nonparametric methods, based on the U.S. Food and Drug Administration's recognized consensus standards, were used to calculate 95% RIs. A comparison between the calculated RIs and those available from previously published research is provided.Results Summary statistics and RIs were calculated for 47 outcome parameters from 13 oculomotor and reaction time tests. Sample sizes and age ranges varied across outcome parameters depending on the availability of reference values for RI calculations. The sample sizes used to calculate RIs ranged from 51 to 69. The age of SMVs included in each RI ranged from 19 to 61 years with mean ages ranging from 37 to 39 years. Similarities/differences between the RIs in the present study and those in previously published research are highly dependent on the outcome parameter; however, in general, the RIs in the present study tended to be somewhat wider.Conclusion The RIs provided in this paper can serve as comparisons for clinicians and scientists who are utilizing these oculomotor and reaction time testing paradigms in similar cohorts of patients or research participants.

Audiology & Speech-Language Pathology↗

Evaluating the Effectiveness of Soil Profile Rehabilitation for Pluvial Flood Mitigation Through Two-Dimensional Hydrodynamic Modeling

Pluvial flooding, driven by increasingly impervious surfaces and intense storm events, presents a growing challenge for urban areas worldwide. In Baltimore City, MD, USA, climate change, rapid urbanization, and aging stormwater infrastructure are exacerbating flooding impacts, resulting in significant socio-economic consequences. This study evaluated the effectiveness of a soil profile rehabilitation scenario using a 2D hydrodynamic modeling approach for the Tiffany Run watershed, Baltimore City. This study utilized different extreme storm events, a high-resolution (1 m) LiDAR Digital Terrain Model (DTM), building footprints, and hydrological soil data. These datasets were integrated into a fully coupled 2D hydrodynamic model, the City Catchment Analysis Tool (CityCAT), to simulate urban flood dynamics. The pre-soil rehabilitation simulation revealed a maximum water depth of 3.00 m in most areas, with hydrologic soil groups C and D, especially downstream of the study area. The post-soil rehabilitation simulation was targeted at vacant lots and public parcels, accounting for 33.20% of the total area of the watershed. This resulted in a reduced water depth of 2.50 m. Additionally, the baseline runoff coefficient of 0.49 decreased to 0.47 following the rehabilitation, and the model consistently recorded a peak runoff reduction rate of 4.10 across varying rainfall intensities. The validation using a contingency matrix demonstrated true-positive rates of 0.75, 0.50, 0.64, and 0 for the selected events, confirming the model’s capability at capturing real-world flood occurrences.

Baltimore City↗

Stent-Retriever Thrombectomy and Rescue Treatment of M1 Occlusions Due to Underlying Intracranial Atherosclerotic Stenosis: Cohort Analysis and Review of the Literature

Background and Purpose: Data on the management of large vessel occlusion in patients with anterior circulation acute ischemic stroke (AIS) due to underlying intracranial stenosis are scarce. The aim of this retrospective study was to compare endovascular treatment and outcome in AIS patients with and without underlying stenosis of the M1 segment. Materials and Methods: A total of 533 acute stroke patients with an isolated M1 occlusion who underwent mechanical thrombectomy between 02/2010 and 08/2017 were included. Underlying intracranial atherosclerotic stenosis (ICAS) was present in 10 patients (1.9%), whereas 523 patients (98.1%) had an embolic occlusion without stenosis. Results: There was no difference in age, admission National Institutes of Health Stroke Scale, risk factors, Alberta stroke program early CT score or collaterals between the groups. Procedure time (155 vs 40 min, P = 0.001) was significantly longer in the ICAS group where rescue stent-angioplasty was performed in all patients. There was no statistical difference in final modified thrombolysis in cerebral infarction score between both groups (70 vs 88%, P = 0.115). Favorable outcome (modified Rankin Scale ≤ 2) at 90 days was less frequent in patients with ICAS than in the embolic group (0 vs 49.4%, P = 0.004). The mortality rate tended to be higher in the ICAS group (44.4 vs 19.4%, P = 0.082). Conclusion: In patients with AIS, rescue therapy with stent placement to treat underlying ICAS of the M1 segment is technically feasible; however, in our study, a significantly lower rate of favorable outcome was observed in these patients compared to those with thromboembolic M1 occlusions. Level of Evidence: Level 3, non-randomized controlled study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An uncertainty-focused database approach to extract spatiotemporal trends from qualitative and discontinuous lake-status histories

Changes in lake status are often interpreted as palaeoclimate indicators due to their dependence on precipitation and evaporation. The Global Lake Status Database (GLSDB) has since long provided a standardised synopsis of qualitative lake status over the last 30,000 14C years. Potential sources of uncertainty however are not recorded in the GLSDB. Here we present an updated and improved relational-database framework that incorporates uncertainty in both chronology and the interpretation of palaeoenvironmental data. The database uses peer-reviewed palaeolimnological studies to produce a consensus on qualitative lake-status histories, whose chronologies are revised and standardized through the recalibration of radiocarbon dates and the application of Bayesian age-depth modelling for stratigraphic archives. Quantitative information on absolute water-level elevation is preserved if available from geomorphological sources. We also propose a new probabilistic analytical framework that accounts for these uncertainties to reconstruct synoptic, integrated environmental signals. The process is based on a Monte Carlo algorithm that iteratively samples individual lake-status histories within the limits of their uncertainties to produce many possible scenarios. We then use Recursively-Subtracted Empirical Orthogonal Function analysis to extract dominant patterns of lake-status variability from these scenarios. As a proof of concept, we apply this framework to 67 sites in eastern and southern Africa whose lake-status histories cover part of the late Pleistocene and/or Holocene. We show that, despite the sometimes large temporal and interpretation uncertainties, and the inclusion of highly discontinuous lake-status time series, identifying the major known millennial-scale climatic phases during the last 20,000 years is possible. Our framework was also able to identify an antiphased response between the lake basins in eastern and interior southern Africa to these changes. Here, we propose that our new database and methodology framework serves as a template for efficient lake-status data synthesis, encourages the incorporation of lake-status data in palaeoclimate syntheses, and expands the possibilities for the use of such data in the evaluation of climate models.

58 GEOSCIENCES↗

In Situ Investigation of Upper Airway Occlusion in Sleep Disordered Breathing Using Ultrasonic Transducer Arrays

This work presents a novel application of ultrasound for the real-time, non-invasive investigation of occlusion of the upper airway during events of obstructive sleep apnea/hypopnea syndrome. It is hypothesized that ultrasonic pulses applied to the neck during apneic events produce spectral and temporal features that can detect apnea occurrence. Theoretical models of ultrasound propagation and an in vitro test were conducted to test this hypothesis in both transmission and reflection modes. Complete specifications and technical details of the system design and fabrication, which is mounted on each subject’s neck, are presented, including the methodology. Nine patients (seven male and two female, mean age of 42 years, with a range of 25 to 56 years, and body mass index 37.6 ± 6.6 kg/m2) were recruited for a full night study, which included simultaneous nocturnal polysomnography for the validation of the results. Nine temporal features and four spectral features were extracted from the envelope of the received pulse waveform. These were used to compute 26 metrics to quantify the changes in the ultrasonic waveforms between normal breathing and apneic events. The statistical analysis of the collected ultrasonic data showed that at least two or more of the proposed features could detect apneic events in all subjects. The findings establish the feasibility of the proposed method as a cost-effective and non-invasive OSAHS screening tool.

60 APPLIED LIFE SCIENCES↗

Effects of charging rates on LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622)/graphite Li-ion cells

Enabling fast charging capability of lithium-ion battery is of great importance to widespread adoption of electric vehicles. Increasing the charging rates from state-of-the-art 2C (30 min) to 6C (10 min) requires deep understanding on the cell aging mechanism. Here, 400 mAh pouch cells are cycled at 1C, 4C and 6C charging rates with 1C discharging rate. Capacity fading, cathode structural changes, Li inventory loss, electrolyte composition changes and Li plating on graphite electrodes are thoroughly studied by various characterization techniques. The rapid capacity fading in cells at 6C charging rate is mainly due to Li inventory loss from cathode structure and metallic Li plating on graphite electrode at higher charging rate. Post-mortem analysis also revealed changes in electrolyte such as increased salt molarity and transesterification during fast charging.

25 ENERGY STORAGE↗