Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AMPLIFIER DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Monopulse receiver

A time division multiplexing and a quadraphase combining dual channel system were analyzed, designed, and tested. Analyses performed include the following: (1) boresight error as a function of the error channel bandwidth; (2) error channel interference with the sum channel functions; (3) threshold performance; and (4) error channel crosstalk, linearity, and drift as a function of signal level, Doppler, and environment. Test results indicate that the time division multiplexing system meets the design goals of the program. However, careful selection and alignment of all gain controlled amplifiers are required along with temperature compensation of the angle channel gain. The quadraphase system crosstalk performance is comparatively poor (-15 dB) with respect to the -30 dB requirements and this consequently affects gain tracking performance. Gain tracking was found to be + or - 20 percent rather than the + or - 5 percent specification. Data for the two systems is compared and recommendations are presented.

Source record↗

Semiconductor millimeter and centimeter wave radiometer for the study of the radiation of an underlying surface

A theoretical and experimental investigation of a superheterodyne radiometer system with input frequency converter and intermediate frequency modulation is presented. Conditions are found, at which the temperature sensitivity of the device does not deteriorate. A sensitivity function to external parameters (temperature, heterodyne power) of a radiometer system with intermediate frequency modulation and a Schottky diode frequency converter is presented and calculated. Use of a frequency converter at the second harmonic of the heterodyne permitted simplication of the radiometer design and the use of a semiconductor heterodyne. A 3 cm range intermediate frequency amplifier permitted the use of centimeter wave radiometer signals. Fluctuation sensitivity of radiometers with a 1 sec time constant is 0.3 K at 3.4 mm and 0.06 K at 3 cm.

Bordonskiy, G. S.↗

JPL's role in the SETI program

The goal of the JPL SETI Team is to develop the strategies and the instrumentation required to carry out an effective, yet affordable, SETI Microwave Observing Program. The primary responsibility for JPL is the development and implementation of the Sky Survey component of the bimodal search program recommended by the SETI Science Working Group (NASA Technical Paper 2244, 1983). JPL is also responsible for the design and implementation of microwave analog instrumentation (including antenna feed systems, low noise RF amplifiers, antenna monitor and control interfaces, etc.) to cover the microwave window for the Sky Survey and the Target Search observations. The primary site for the current SETI Field Test activity is the Venus Station of the Goldstone Deep Space Communication Complex. A SETI controller was constructed and installed so that pre-programmed and real time SETI monitor and control data can be sent to and from the station controller. This unit will be interfaced with the MCSA. A SETI Hardware Handbook was prepared to describe the various systems that will be used by the project at the Venus Station; the handbook is frequently being expanded and updated. The 65,000 channel FFT Spectrum analyzer in the RFI Surveillance System was modified to permit operation with variable resolutions (300 Hz to less than 1 Hz) and with real-time accumulation, which will enhance the capability of the system for testing Sky Survey search strategies and signal detection algorithms.

Klein, M. J.↗

Cryogenetically Cooled Field Effect Transistors for Low-Noise Systems

Recent tends in the design, fabrication and use of High-Electron-Mobility-Transistors (HEMT) in low noise amplifiers are reviewed. Systems employing these devices have achieved the lowest system noise for wavelengths greater than three millimeters with relatively modest cryogenic cooling requirements in a variety of ground and space based applications. System requirements which arise in employing such devices in imaging applications are contrasted with other leading coherent detector candidates at microwave wavelengths. Fundamental and practical limitations which arise in the context of microwave application of field effect devices at cryogenic temperatures will be discussed from a component and systems point of view.

Wollack, Edward J.↗

Cryogenically Cooled Field Effect Transistors for Low-Noise Systems

Recent tends in the design, fabrication and use of High-Electron-Mobility-Transistors (HEMT) in low noise amplifiers are reviewed. Systems employing these devices have achieved the lowest system noise for wavelengths greater than three millimeters with relatively modest cryogenic cooling requirements in a variety of ground and space based applications. System requirements which arise in employing such devices in imaging applications are contrasted with other leading coherent detector candidates at microwave wavelengths. Fundamental and practical limitations which arise in the context of microwave application of field effect devices at cryogenic temperatures will be discussed from a component and systems point of view.

Wollack, Edward J.↗

Waveguide Transition for Submillimeter-Wave MMICs

An integrated waveguide-to-MMIC (monolithic microwave integrated circuit) chip operating in the 300-GHz range is designed to operate well on high-permittivity semiconductor substrates typical for an MMIC amplifier, and allows a wider MMIC substrate to be used, enabling integration with larger MMICs (power amplifiers). The waveguide-to- CBCPW (conductor-backed coplanar waveguide) transition topology is based on an integrated dipole placed in the E-plane of the waveguide module. It demonstrates low loss and good impedance matching. Measurement and simulation demonstrate that the loss of the transition and waveguide loss is less than 1-dB over a 340-to-380-GHz bandwidth. A transition is inserted along the propagation direction of the waveguide. This transition uses a planar dipole aligned with the maximum E-field of the TE10 waveguide mode as an inter face between the waveguide and the MMIC. Mode conversion between the coplanar striplines (CPS) that feed the dipole and the CBCPW transmission line is accomplished using a simple air-bridge structure. The bottom side ground plane is truncated at the same reference as the top-side ground plane, leaving the end of the MMIC suspended in air.

Leong, Kevin M.↗

A compact 10 kW, 476 MHz solid state radio frequency amplifier for pre-buncher cavity of free electron laser injector linear accelerator

A 10 kW, 476 MHz, 0.1% duty cycle solid state RF amplifier system for driving sub-harmonic, pre-buncher cavity of IR-FEL injector LINAC, has been developed at RRCAT. The 10 kW power is achieved by combining output of eight 1400 W amplifier modules using 8-way planar corporate combiner. The solid state amplifier modules have been developed using 50 V RF LDMOS transistors which although meant for push-pull operation are being used in single ended configuration with matching circuit developed on a thin (25 mils), high dielectric constant (9.7), low loss microwave laminate with an aim to have a compact structure. Ease of fabrication, modularity, small size, and low cost are the important features of this design which could be used as a template for low duty cycle medium to high pulsed power UHF amplifier system.

43 PARTICLE ACCELERATORS↗

An Efficient RF Source for Jlab

We propose the development of a highly reliable high efficiency RF source for JLAB with a lower lifetime cost operating at 80% efficiency with system operating costs of about 0.7M$/year for the 6 GeV machine. The design of the RF source will be based upon two injection locked magnetrons in a novel combining architecture for amplitude modulation and a cross field amplifier (CFA) as an output tube for the 12 GeV upgrade. A cost analysis including efficiency and reliability will be performed to determine the optimum system architecture. Several different system architectures will be designed and evaluated for a dual injection locked magnetron source using novel combining techniques and possibly a CFA as the output tube. A paper design for the 1497 MHz magnetron system will be completed. The optimum system architecture with all relevant specifications will be completed so that a prototype can be built.

43 PARTICLE ACCELERATORS↗

Demonstration and Optimization of a Drive Laser for an X-Band Photoinjector

Recently, a drive laser for an S-band (2.86 GHz) rf photoinjector, designed to provide a pulse that has a flat temporal and spatial profile, has been built, commissioned, and put into service as part of the LLNL Compton-scattering monoenergetic {gamma}-ray source program. This laser is based on an all-fiber oscillator and front-end amplification system, and provides both the laser light to generate the electrons as well as the rf signal that is amplified to accelerate them. Now, a new 11.424 GHz photoinjector is being developed, which has required a revised design for the laser system. The higher frequency has placed more stringent requirements on the synchronization stability, delivered pulse length, and pulse rise times to maintain the desired emittance. Presented here are the overall design and measured performance of the current system and a discussion of what changes are being made to address observed shortcomings and more demanding requirements to make the system ready for the next-generation Compton-scattering monoenergetic {gamma}-ray source.

42 ENGINEERING↗

THE JLAMP VUV/SOFT X-RAY USER FACILITY AT JEFFERSON LABORATORY

Jefferson Lab (JLab) is proposing JLAMP (JLab Amplifier), a 4th generation light source covering the 10-100 eV range in the fundamental mode with harmonics stretching towards the oxygen k-edge. The new photon science user facility will feature a two-pass superconducting LINAC to accelerate the electron beam to 600MeV at repetition rates of 4.68MHz continuous wave. The average brightness from a seeded amplifier free electron laser (FEL) will substantially exceed existing light sources in this device's wavelength range, extended by harmonics towards 2 nm. Multiple photon sources will be made available for pump-probe dynamical studies. The status of the machine design and technical challenges associated with the development of the JLAMP are presented here.

43 PARTICLE ACCELERATORS↗

SU-E-T-66: A Prototype for Couch Based Real-Time Dosimetry in External Beam Radiotherapy

Purpose: The main purpose of this study is to design a prototype for couch-based based real time dosimetry system in external beam radiotherapy Methods: A prototype of 100 ionization chambers was designed on a printed circuit board by etching the copper layer and each ionization chamber was wired to a 50 pin connector. The signals from the two 50 pin connectors collected from the ionization chambers were then transferred to a PXI module from National Instruments. The PXI module houses a current amplifier that amplifies the charge collected from the ionization chamber. The amplified signal is then sent to a digital multimeter module for converting the analog signal to digital signal. A software was designed in labview to read and display the signals obtained from the PXI module. A couch attachment frame was designed to house the 100 ionization chamber module. The frame was fixed underneath the treatment couch for measuring the dose during treatment. Resutls: The ionization chamber based prototype dosimetry was tested for simple radiotherapy treatment fields and found to be a useful device for measuring real time dosimetry at the treatment couch plane. This information could be used to assess the delivered dose to a patient during radiotherapy. It could be used as an invivo dosimeter during radiotherapy. Conclusion: In this study, a prototype for couch based real time dosimetry system was designed and tested. The prototype forms a basis for the development of large scale couch based real time dosimetry system that could be used to perform morning QA prior to treatment, assess real time doses delivered to patient and as a device to monitor the output of the treatment beam. Peter MacCallum Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Nondeterministic amplifier for two-photon superpositions

We examine heralded nondeterministic noiseless amplification based on the quantum scissors device, which has been shown to increase the one-photon amplitude of a state at the expense of the vacuum-state amplitude. Here we propose using the same basic design to perform perfect amplification in a basis set of up to two photons. The device is much more efficient than several one-photon amplifiers working in tandem. When used to amplify coherent states this advantage is shown either using fidelity or in terms of probability of successful action, or more strikingly in a combination of the two.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lossless Quantum Hard-Drive Memory Using Parity-Time Symmetry

We theoretically studied the feasibility of building a long-term read-write quantum memory using the principle of parity-time (PT) symmetry, which has already been demonstrated for classical systems. The design consisted of a two-resonator system. Although both resonators would feature intrinsic loss, the goal was to apply a driving signal to one of the resonators such that it would become an amplifying subsystem, with a gain rate equal and opposite to the loss rate of the lossy resonator. Consequently, the loss and gain probabilities in the overall system would cancel out, yielding a closed quantum system. Upon performing detailed calculations on the impact of a driving signal on a lossy resonator, our results demonstrated that an amplifying resonator is physically unfeasible, thus forestalling the possibility of PT-symmetric quantum storage. Our finding serves to significantly narrow down future research into designing a viable quantum hard drive.

97 MATHEMATICS AND COMPUTING↗

Frequency division multiplexer code 04236, serial no. 001, phase 2

Design principles and test results of modifications to two wideband channels, 8 kHz DS located at 44kHz and 16 kHz SSB located at 104 kHz, are given. Data cover power supply modifications, wideband operational amplifiers, trade-off to determine requirements for precision components, printed circuit board layout, applicability of original equipment specification No. 110438, and optimum wideband channel design.

Hauge, G.↗

Universal tritium transmitter

At the Savannah River Site and throughout the National Nuclear Security Agency (NNSA) tritium is measured using Ion or Kanne Chambers. Tritium flowing through an Ion Chamber emits beta particles generating current flow proportional to tritium radioactivity. Currents in the 1 x 10{sup -15} A to 1 x 10{sup -6} A are measured. The distance between the Ion Chamber and the electrometer in NNSA facilities can be over 100 feet. Currents greater than a few micro-amperes can be measured with a simple modification. Typical operating voltages of 500 to 1000 Volts and piping designs require that the Ion Chamber be connected to earth ground. This grounding combined with long cable lengths and low currents requires a very specialized preamplifier circuit. In addition, the electrometer must be able to supply 'fail safe' alarm signals which are used to alert personnel of a tritium leak, trigger divert systems preventing tritium releases to the environment and monitor stack emissions as required by the United States federal Government and state governments. Ideally the electrometer would be 'self monitoring'. Self monitoring would reduce the need for constant checks by maintenance personnel. For example at some DOE facilities monthly calibration and alarm checks must be performed to ensure operation. NNSA presently uses commercially available electrometers designed specifically for this critical application. The problems with these commercial units include: ground loops, high background currents, inflexibility and susceptibility to Electromagnetic Interference (EMI) which includes RF and Magnetic fields. Existing commercial electrometers lack the flexibility to accommodate different Ion Chamber designs required by the gas pressure, type of gas and range. Ideally the electrometer could be programmed for any expected gas, range and high voltage output. Commercially available units do not have 'fail safe' self monitoring capability. Electronics used to measure extremely low current must have sufficient time to thermally equilibrate. Amplifiers, transistors, resistors all need time to stabilize before the electrometer circuit will measure accurately in the 10{sup -15} and 10{sup -14} ampere range. Existing electrometers give the user no indication when the unit has stabilized and is acceptable for low level measurements. Savannah River National Laboratory (SRNL) funded through the NNSA Plant Directed Research and Development (PDRD) program, has developed a truly Universal Tritium Transmitter (UTT) capable of solving many known problems with existing commercial electrometers. This UTT pushes the state-of-the-art in electrometer design and incorporates solutions to deficiencies found in commercial electrometers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Engineering synchronization of chaotic oscillators

We propose a controller based coupling design for engineering synchronization in chaotic oscillators for unidirectional as well as bi-directional mode. In the synchronization regimes, it is possible to amplify/ attenuate a chaotic attractor with respect to other chaotic attractors. Numerical examples are presented for a Lorenz system, a Roessler oscillator, and a Sprott system. Physical implementation of the scheme is done in electronic circuit to design the controller for verification of the theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Novel Front-End ASIC With Post Digital Filtering and Calibration for CZT-Based PET Detector

This paper presents a novel front-end electronics based on a front-end ASIC with post digital filtering and calibration dedicated to CZT detectors for PET imaging. A cascade amplifier based on split-leg topology is selected to realize the charge-sensitive amplifier (CSA) for the sake of low noise performances and the simple scheme of the power supplies. The output of the CSA is connected to a variable-gain amplifier to generate the compatible signals for the A/D conversion. A multi-channel single-slope ADC is designed to sample multiple points for the digital filtering and shaping. The digital signal processing algorithms are implemented by a FPGA. To verify the proposed scheme, a front-end readout prototype ASIC is designed and implemented in 0.35 μm CMOS process. In a single readout channel, a CSA, a VGA, a 10-bit ADC and registers are integrated. Two dummy channels, bias circuits, and time controller are also integrated. The die size is 2.0 mm x 2.1 mm. The input range of the ASIC is from 2000 e{sup -} to 100000 e{sup -}, which is suitable for the detection of the X-and gamma ray from 11.2 keV to 550 keV. The linearity of the output voltage is less than 1 %. The gain of the readout channel is 40.2 V/pC. The static power dissipation is about 10 mW/channel. The above tested results show that the electrical performances of the ASIC can well satisfy PET imaging applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗