Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

The use of a digital micromirror array as a temporal gate and spatial-filtering device for laser-induced breakdown spectroscopy and laser ablation molecular isotopic spectrometry

A digital micromirror array (DMMA) is used in a simple and inexpensive approach for spatially resolved temporal gating of atomic emission detection in laser-induced breakdown spectroscopy (LIBS). Selected mirrors in the array are actuated at a time delayed from the primary laser pulse, permitting optical gating with a response time of 160 ns while using a conventional CCD detector. Detector gating is shown to decrease noise from short-lived spectroscopic background (both continuum and N II from air), improving signal-to-background ratios by 22-times for selected samples and emission lines. The utility of rapid temporal gating is also demonstrated for the optical detection of isotopes using the laser-ablation molecular isotope spectrometry (LAMIS) experiment. Additionally, optical temporal gating and spatial filtering are used to isolate regions of the laser-induced plasma, enhancing signal from molecular emission. The potential of the simple technique for use in field-portable LIBS and LAMIS experiments is explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

Lysosomotropic cationic drugs induce cytostatic and cytotoxic effects: Role of liposolubility and autophagic flux and antagonism by cholesterol ablation

Cation trapping in acidic cell compartments determines an antiproliferative effect that has a potential interest in oncology, as shown by clinical data and trials involving chloroquine and hydroxychloroquine. To further characterize the mechanism of this effect, we studied a series of 6 substituted triethylamine (s-Et{sub 3}N) drugs that encompasses a wide range of liposolubility (amiodarone, quinacrine, chloroquine, hydroxychloroquine, lidocaine, and procainamide). Three tumor cell lines and primary human endothelial cells were exploited in proliferation assays (48 h, cell counts). Accumulation of the autophagic effector LC3 II and the apoptotic marker cleaved PARP1 (immunoblots), cytotoxicity, cell cycle analysis and endocytic function were further tested in the p53-null histiocytic lymphoma U937 line. A profound and desynchronized antiproliferative effect was observed in response to all s-Et{sub 3}Ns with essentially no cell type specificity. Predictors of s-Et{sub 3}N potency were liposolubility and the acute accumulation of the autophagic effector LC3 II (6 h-treatments). For each s-Et{sub 3}N, there was an antiproliferative concentration range where cytotoxicity and apoptosis were not triggered in U937 cells (24–48 h-treatments). Quinacrine was the most potent cytostatic drug (1–5 μM). Co-treatment of cells with inhibitors of cholesterol, β-cyclodextrin or lovastatin, partially reversed the antiproliferative effect of each s-Et{sub 3}N. The cytopathology induced by cationic drug accumulation includes a cytostatic effect. Its intensity is cell type- and p53-independent, but predicted by the inhibition of autophagic flux and by the liposolubility of individual drugs and alleviated by cholesterol ablation. The superiority of quinacrine, biomarker value of LC3 II and antagonism by a statin may be clinically relevant. - Highlights: • Cation trapping in acidic cell compartments induces a cytostatic effect. • A series of substituted triethylamines has been studied in 4 cell types. • Cytostatic potency is predicted by lipophilicity and autophagic flux inhibition. • β-Cyclodextrin or lovastatin co-treatment reverses the antiproliferative effect.

60 APPLIED LIFE SCIENCES↗

Surface Nanostructure Control and Thermodynamic Stability Analysis of Femtosecond Laser-Ablated CuCoMn 1.75 NiFe 0.25 Nanoparticles

Surface nanostructure control is the key to functionalizing nanomaterials. This paper presents a characterization with thermodynamic stability analysis of CuCoMn 1.75 NiFe 0.25 high-entropy alloy (HEA) nanoparticles synthesized by femtosecond laser ablation in ethanol and liquid nitrogen (LN2). Using multimodal electron microscopy and spectroscopy, we examine phase, particle size, defect structure, chemical distribution, and surface composition and relate them to HEA stability. Elemental distributions are uniform in both media, but LN2 produces smaller particles with a narrower size distribution and mainly single- or few-domain interiors, whereas ethanol yields larger particles built from 2–4 nm crystallites with domain aggregation. Edge defects appear in both but energy-dispersive X-ray spectroscopy (EDS) is broadly uniform with local fluctuations in ethanol. X-ray photoelectron spectroscopy (XPS), supported by an attenuation model, indicates an ∼1 nm oxide overlayer that suppresses Mn 2p intensity; correcting for it returns Mn toward the bulk value. UV–NIR and photoluminescent spectra independently support a thin oxide shell. Composition-based thermodynamic descriptors place LN2 closer to bulk mixing parameters, while ethanol raises ΔH_mix and lowers Ω. Cooling simulations are consistent (LN2 ∼ 0.1 μs quench, ethanol ∼1 μs). In conclusion, these results connect solvent-controlled kinetics and thermodynamics to crystalline state and surface chemistry, informing surface control of HEA nanoparticles.

Femtosecond Laser Ablation↗

Design Calculations For NIF Convergent Ablator Experiments

The NIF convergent ablation tuning effort is underway. In the early experiments, we have discovered that the design code simulations over-predict the capsule implosion velocity and shock flash rhor, but under-predict the hohlraum x-ray flux measurements. The apparent inconsistency between the x-ray flux and radiography data implies that there are important unexplained aspects of the hohlraum and/or capsule behavior.

42 ENGINEERING↗

Observation of near total polarization in the ultrafast laser ablation of Si

We report nearly completely polarized emission from the plasma produced in the femtosecond ablation of Si(111). Pairs of ultrashort laser pulses were focused onto the target in air, and the polarization spectrum was measured as a function of energy, pulse delay, and polarization state of the laser. When the laser was focused on the surface, the fluorescence continuum was strongly polarized, whereas discrete lines appeared as minima in the polarization spectrum. Under this focusing condition, the continuum polarization increased with pulse delay and decreased with pulse energy and fluorescence wavelength, with >95% polarization in the ultraviolet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectroscopic characterization of laser ablation brass plasma

We present optical emission studies of the laser ablation brass plasma generated by the fundamental, second, and third harmonics of a neodymium doped yttrium aluminum garnet laser. The spectra predominantly reveal the spectral lines of the neutral and singly ionized copper and zinc. The excitation temperatures are determined by the Boltzmann plot method, whereas the electron number densities have been extracted from the Stark broadened line profiles. The spatial variations in the spectral line intensities and the plasma parameters at 1000, 500, and 100 mbar air pressures have been evaluated. Besides, the effect of the ambient gases (He, Ne, and Ar), the laser irradiance, and the laser wavelengths on the plasma parameters have been investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reducing nanoparticles in metal ablation plumes produced by two delayed short laser pulses

Using fast imaging and atomic force microscopy, we demonstrate that the fraction of nanoparticles in ablation plumes produced by short pulse laser irradiation of metals is strongly altered when a second laser pulse of sufficiently large delay is applied. Comparing the results obtained for gold and copper, it is shown that a significant nanoparticle reduction is only observed if the delay between both laser pulses exceeds the characteristic time of electron-lattice thermalization. We propose the reduced electronic heat transport at large lattice temperature as the dominant mechanisms for the observed nanoparticle reduction.

36 MATERIALS SCIENCE↗

Charge Exchange and Ablation Rates of a Titanium Wire Plasma Corona

Wire ablation rates are important features in any examination of precursors or transparent mode implosions of wire arrays. When ion temperatures in a Ti wire plasma corona exceed a few eV, the process of resonant charge exchange competes with elastic scattering. Ions pushed into the corona from an anode bias wire array can be expected to drive a fast neutral wind into the surrounding volume, while a cathode bias wire array would not show the strong neutral wind.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser ablation of metallic targets with high fluences: Self-consistent approach

Ablation of metallic target using Gaussian profile laser pulse with duration of 30 ns and fluence extending up to 100 J/cm{sup 2} is studied. A self-consistent model that involves numerical simulation to obtain the thickness of a hydrodynamic layer is proposed. The influence of the hydrodynamic layer thickness on Knudsen layer properties, and hence the rate of evaporation, is demonstrated. Self-consistent model is compared with model based on assumption about sonic speed at the Knudsen layer outer edge and validated with experimental results for Al alloy and Cu. Finally, sample calculations are performed using the proposed model to obtain depth of evaporation of Al alloy for single pulse duration.

36 MATERIALS SCIENCE↗

Comment on ''Generation of cold low divergent atomic beam of indium by laser ablation'' [Rev. Sci. Instrum. 76, 113302 (2005)]

We present measurements of the velocity distribution of calcium atoms in an atomic beam generated using a dual-stage laser back-ablation apparatus. Distributions are measured using a velocity selective Doppler time-of-flight technique. They are Boltzmann-like with rms velocities corresponding to temperatures above the melting point for calcium. Contrary to a recent report in the literature, this method does not generate a subthermal atomic beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision in Strontium Isotope Measurements by Laser Ablation Assisted Resonance Ionization Mass Spectrometry

We have investigated the precision of strontium isotope analysis by Laser Ablation-assisted Resonance Ionization Mass Spectrometry(LA-RIMS). We have confirmed that the mass discrimination effect on the {sup 87}Sr/{sup 86}Sr measurement was reduced by the internal correction method. For the present system, the precision of the isotope ratio of {sup 87}Sr/{sup 86}Sr has been estimated to be 0.6%(1{sigma}). The precision has been limited by the fluctuations with a time scale of less than 10 s.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Angular distribution of atoms ejected by laser ablation of different metals

Angular distributions of 13 different metals ejected by laser ablation using fourth harmonics (wavelength=266 nm) of neodymium doped yttrium aluminum garnet laser and a fluence close to near-threshold value (2.3 J/cm{sup 2}) have been investigated with a high angular resolution. The angular distribution which is characterized by the exponent n of cos{sup n} theta distribution showed very broad range of values between 3 and 24 for different metals. A simple relation that the exponent n is proportional to the square root of particle atomic weight as reported previously has not been observed. Instead, a general trend has been found that the metals with higher sublimation energy such as Ta and Zr show narrower angular distribution than those with lower sublimation energy such as Sn and In. While the sublimation energy of metals has a great influence on the angular distribution of ejected atoms, a simple consideration suggests that their thermal conductivity and specific heat have little effect on it.

36 MATERIALS SCIENCE↗

Synthesis of Nickel Nanomaterial by Pulsed Laser Ablation in Liquid Medium and its Characterization

Laser ablation of nickel nanoparticles suspended in double deionized water has been studied using Nd:YAG laser (355 nm) with energy 30 mJ/pulse. Produced nanoparticles are analyzed by UV-visible absorption spectroscopy at certain interval (0, 20, 40, 60 minute). The particles are characterized by Transmission Electron Microscopy (TEM), and X-ray Diffraction (XRD). TEM image shows that particles have crystal like structure and these particles are in the range of 20 nm to 50 nm.

36 MATERIALS SCIENCE↗

Fractal Character of Titania Nanoparticles Formed by Laser Ablation

Titania nanoparticles were fabricated by laser ablation of polycrystalline rutile in water at room temperature. The resulting nanoparticles were analyzed with x-ray diffraction, Raman spectroscopy, and transmission electron microscopy. The electron micrograph image of deposited nanoparticles demonstrates fractal properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Optical Thomson scatter from a laser-ablated magnesium plume

We have carried out an optical Thomson scatter study of a KrF laser-ablated Mg plume. The evolution of the electron temperature and density at distances 2-5 mm from the target surface has been studied. We have observed that the electron density falls more rapidly than the atomic density and believe that this is a result of rapid dielectronic recombination. A comparison of the electron density profile and evolution with simple hydrodynamic modeling indicates that there is a strong absorption of the laser in the plasma vapor above the target, probably due to photoionization. We also conclude that an isothermal model of expansion better fits the data than an isentropic expansion model. Finally, we compared data obtained from Thomson scatter with those obtained by emission spectroscopy under similar conditions. The two sets of data have differences but are broadly consistent.

36 MATERIALS SCIENCE↗

Near-field imaging of femtosecond laser ablated sub-{lambda}/4 holes in lithium niobate

We report on the direct femtosecond laser ablation of sub-{lambda}/4 (80-250 nm) holes in LiNbO{sub 3} crystals and on its local near-field imaging. We show that the near-field transmission of holes can feature an attenuation of {approx}75% at hole central position, and a {approx}20% transmission enhancement at its sides. This high-contrast ring-shaped near-field distribution is found to be in agreement with simulations, suggesting the surface relief as the main contrast mechanism00.

36 MATERIALS SCIENCE↗