Thermographic detection of disbonds
The presence of disbonds significantly decreases the integrity of many laminated structures used in aerospace applications. A thermographic technique is presented which is able to detect subsurface delamination. The technique uses one of several heat sources (such as hot water, hot air, IR lamps, etc.) to increase the surface temperature of the structure. The subsequent temperature profiles of the surface are detected with an IR camera. A novel spatial filter developed at NASA-Langley eliminates the effects of uneven heating to give clear images of the subsurface delaminations. Defects are detectable in samples as diverse as solid rocket motor samples and laminated wood for wind tunnel blades. Numerical simulations are presented for comparison with experiment results.