Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Evaluation of Nominal Energy Storage at Existing Hydropower Reservoirs in the US

Long-term planning and operation of hydropower reservoirs require an understanding of both water and energy storage. As energy storage needs of the evolving grid increase, we must account for the water and energy storage potential of these reservoirs. Given the limitations of current data on existing hydropower, we compile statistics related to storage volume and hydraulic head from publicly available data sets and examine differences in descriptions of US hydropower storage. Assembled characteristics are used to calculate nominal energy storage capacity, a simple measure of potential to generate power from a given volume of water, not factoring in detailed constraints. Inventory-based estimates of energy storage are calculated at 2,075 dams, which helps put the potential for US hydropower to support energy storage in context with similar evaluations in other regions and with other energy storage technologies. The national energy storage capacity ranges between 34.5 and 45.1 TWh depending on the information used, with 52% of energy storage located at the 10 largest reservoirs in the US. Energy storage capacities are also calculated at 236 dams with historical volume and elevation data. Finally, reservoir inflows provide context for the storage volumes and sensitivities to hydrologic variability. Larger reservoirs with greater storage volume to inflow ratios are concentrated in the Western US, but the majority of hydropower reservoirs store less than the annual inflow. We address several infrastructure and water resource informatics challenges and highlight remaining issues, including representing seasonal or shorter variability in water volumes and representing connected hydropower facilities.

13 HYDRO ENERGY↗

Compound flood simulations indicate rising public exposure to sewage-contaminated waters in Waikīkī, Hawai‘i

Waikīkī, Hawai‘i serves as a valuable case study for flood vulnerability due to its low elevation, present-day exposure to multiple flood sources, and role as the state’s economic engine. This study applies the high-resolution, open-source WRF-Hydro-CUFA (Coastal Urban Flood Application) model to simulate compound flood interactions among pluvial, fluvial, coastal, storm drain-driven, and subsurface processes, and to evaluate how flood characteristics in Waikīkī evolve under projected sea-level rise (SLR). Simulated water levels in an estuarine drainage canal, serving as the primary outlet for gravity-flow drainage from Waikīkī, show strong agreement with observations (r ≥ 0.935, R 2 ≥ 0.874), accurately reproducing flooding observed during recent 5-year and 50-year storm events. Simulations incorporating SLR demonstrate a shift in dominant flood drivers as sea levels rise. In addition, results identify critical thresholds at which elevated estuarine tailwater conditions cause widespread drainage backflow, eventually occurring in the absence of rainfall. These findings suggest that tidally driven flooding will progressively dominate over rainfall-driven events, increasing public exposure to highly contaminated canal and groundwater sources. The results underscore the urgent need to integrate water quality issues and drainage failure into coastal flood management strategies for low-lying urban environments, particularly those reliant on polluted estuarine waterways for stormwater management.

Compound flooding↗

Retrofit Energy Analysis and Central Thermal modeling (REACT) v1.0

REACT is a website designed to simplify the analysis and decision-making process for retrofitting existing central plant heating and cooling systems with advanced heat pump technologies. The tool evaluates the technical and economic viability of replacing traditional boilers with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. Retrofitting traditional boiler and chiller systems with water-to-water or air-to-water heat pumps can significantly reduce energy consumption and lower lifecycle costs. The REACT provides: User-Friendly Tools: A user friendly web interface for quick, intuitive analysis accessible to non-experts. Advanced Modeling: A Python-powered engine for detailed parametric studies, optimization, and research applications. Comprehensive Analysis: Lifecycle cost evaluation, energy consumption modeling, and environmental impact assessment. Visual Insights: A variety of plots to visualize system performance and design trade-offs. The engine for the website (REACT) bases on several Python libraries, and the website will be hosted on an ETA server.

Kim, Donghun [Lawrence Berkeley National Laborator↗

The Impact of Storms on Legionella pneumophila in Cooling Tower Water, Implications for Human Health

At the U.S. Department of Energy’s Savannah River Site (SRS) in Aiken, SC, cooling tower water is routinely monitored for Legionella pneumophila concentrations using a direct fluorescent antibody (DFA) technique. Historically, 25–30 operating SRS cooling towers have varying concentrations of Legionella in all seasons of the year, with patterns that are unpredictable. Legionellosis, or Legionnaires’ disease (LD), is a pneumonia caused by Legionella bacteria that thrive both in man-made water distribution systems and natural surface waters including lakes, streams, and wet soil. Legionnaires’ disease is typically contracted by inhaling L. pneumophila , most often in aerosolized mists that contain the bacteria. At the SRS, L. pneumophila is typically found in cooling towers ranging from non-detectable up to 10 8 cells/L in cooling tower water systems. Extreme weather conditions contributed to elevations in L. pneumophila to 10 7 –10 8 cells/L in SRS cooling tower water systems in July–August 2017. L. pneumophila concentrations in Cooling Tower 785-A/2A located in SRS A-Area, stayed in the 10 8 cells/L range despite biocide addition. During this time, other SRS cooling towers did not demonstrate this L. pneumophila increase. No significant difference was observed in the mean L. pneumophila mean concentrations for the towers ( p < 0.05). There was a significant variance observed in the 285-2A/A Tower L. pneumophila results ( p < 0.05). Looking to see if we could find “effects” led to model development by analyzing 13 months of water chemistry and microbial data for the main factors influencing the L. pneumophila concentrations in five cooling towers for this year. It indicated chlorine and dissolved oxygen had a significant impact ( p < 0.0002) on cooling tower 785A/2A. Thus, while the variation in the log count data for the A-area tower is statistically greater than that of the other four towers, the average of the log count data for the A-Area tower was in line with that of the other towers. It was also observed that the location of 785A/2A and basin resulted in more debris entering the system during storm events. Our results suggest that future analyses should evaluate the impact of environmental conditions and cooling tower design on L. pneumophila water concentrations and human health.

54 ENVIRONMENTAL SCIENCES↗

Convective Transition Statistics over Tropical Oceans for Climate Model Diagnostics: GCM Evaluation

To assess deep convective parameterizations in a variety of GCMs and examine the fast-time-scale convective transition, a set of statistics characterizing the pickup of precipitation as a function of column water vapor (CWV), PDFs and joint PDFs of CWV and precipitation, and the dependence of the moisture–precipitation relation on tropospheric temperature is evaluated using the hourly output of two versions of the GFDL Atmospheric Model, version 4 (AM4), NCAR CAM5 and superparameterized CAM (SPCAM). The 6-hourly output from the MJO Task Force (MJOTF)/GEWEX Atmospheric System Study (GASS) project is also analyzed. Contrasting statistics produced from individual models that primarily differ in representations of moist convection suggest that convective transition statistics can substantially distinguish differences in convective representation and its interaction with the large-scale flow, while models that differ only in spatial–temporal resolution, microphysics, or ocean–atmosphere coupling result in similar statistics. Most of the models simulate some version of the observed sharp increase in precipitation as CWV exceeds a critical value, as well as that convective onset occurs at higher CWV but at lower column RH as temperature increases. While some models quantitatively capture these observed features and associated probability distributions, considerable intermodel spread and departures from observations in various aspects of the precipitation–CWV relationship are noted. For instance, in many of the models, the transition from the low-CWV, nonprecipitating regime to the moist regime for CWV around and above critical is less abrupt than in observations. Additionally, some models overproduce drizzle at low CWV, and some require CWV higher than observed for strong precipitation. For many of the models, it is particularly challenging to simulate the probability distributions of CWV at high temperature.

54 ENVIRONMENTAL SCIENCES↗

Mechanical Design of the PIP-II ORBUMP Pulsed Dipole Magnet

The Proton Improvement Plan II (PIP-II) project is a vital upgrade to the Fermilab accelerator complex. The magnet pulse rate of the PIP-II Injection system requires an increase from the current rate of 15 Hz to 20 Hz as well as a roughly 30% increase in the magnetic field of the new Orbital Bump (ORBUMP) pulsed dipole magnets in the Booster. Here, the ORBUMP magnet mechanical design is presented in this paper. The ORBUMP magnet is secured in a vacuum box and the core is made up of 0.127 mm thick, low carbon steel laminations with a C-5 inorganic magnesium phosphate coating. The core is clamped using external tie bars welded to the core end plates. ANSYS Finite Element Analysis (FEA) was used to evaluate the clamping design to minimize the deflection of the core post welding of the tie bars. The water-cooled, single turn coil, which shapes the magnetic field by acting as the pole tips, is critical for the integrated field homogeneity. The coil manufacturing tolerances and fabrication techniques were evaluated to ensure the magnetic properties of the magnet could be obtained. The coil is electrically isolated from the core using virgin Polyether ether ketone (PEEK) insulating material in the gap. An investigation into the high voltage performance of the virgin PEEK insulator was conducted via partial discharge testing using a 1:1 scale sample.

Karas, D. [Fermi National Accelerator Laboratory (↗

Droplet Entrainment in Steam Supply System of Water-Cooled Small Modular Reactors: Experiment and Modeling Approaches

Droplet entrainment in steam-flow is a prominent phenomenon that needs adequate safety and risk analysis of postulated transient and accident scenarios—including experimental investigation and representative modeling and simulation (M&S)—for small modular reactor (SMR) system design and demonstration. This study identifies knowledge gaps by evaluating experimental and computational fluid dynamics modeling approaches to support early-stage reactor system design, testing, and model evaluation. Previous studies reported in the literature for steam-flow entrainment primarily focused on gigawatt capacity pressurized water reactor (PWR) systems. However, entrainment phenomena are even more prominent for PWR-type SMRs due to their more compact integrated designs, which need further research and development. To fill the research gaps, this study provides insight by specifying the phenomena of interest by leveraging the lessons learned from past research, adopting advanced M&S techniques and advanced instrumentation and control. The findings and recommendations are applicable for evaluating steam-flow entrainment models and for designing integral effect test and separate effect test facilities for gaining reactor design approvals.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Energy and Water Resilience Indicator Library

Energy and water resilience indicators provide a way to assess a site’s current energy and water resilience status relative to higher-level organizational goals. Using a consistent approach for evaluating the resilience posture of a portfolio of sites provides a mechanism for an organization to track progress over time. It also provides a mechanism for identifying opportunity areas across sites so that organizations can prioritize funding of measures that would benefit multiple sites. The information presented in this document provides an approach to defining energy and water resilience indicators that align with organizational goals, and a reference library of indicators that can help organizations create their own process of tracking the resilience performance of their sites over time.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Numerical modeling of electromagnetic field spatiotemporal evolution to evaluate the effects on calcium carbonate crystallization

Calcium carbonate (CaCO 3 ) scaling is a significant impediment to water systems. Electromagnetic field (EMF) treatment is a promising approach to control scaling owing to its simplicity and low or no energy requirements. However, the underlying mechanisms by which EMF impacts CaCO 3 crystallization remain unclear due to the challenges in measuring the EMFs in feed solutions and the lack of a fundamental understanding of the applied EMFs and the observed physicochemical phenomena. To fill this knowledge gap, a high-fidelity COMSOL model was first developed to simulate EMFs in bulk solutions for three alternating current-induced EMF devices with different configurations and properties. These were then integrated with experimental data to unveil the underlying mechanism by which applied EMFs alter the physicochemical processes. The study revealed that even low-strength EMFs (e.g., electric fields <0.15 V/m and magnetic fields <0.03 mT) promoted CaCO 3 precipitation in bulk solutions. The electric fields created by these EMF devices resulted in higher Lorentz force compared to their induced magnetic fields. In conclusion, the methodology of this study offers the capability to predict the effectiveness of different EMF devices in facilitating crystallization processes, and these mechanistic insights lay the foundation for the smart design of EMF devices for diverse water treatment applications.

COMSOL simulation↗

Evaluating the Case for Reduced Precious Metal Catalysts in Proton Exchange Membrane Electrolyzers

Proton exchange membrane (PEM) water electrolyzers are a key technology in decarbonizing hydrogen production. Though the market for PEM electrolyzer systems is growing, there are concerns that the cost and availability of precious metal catalysts utilized in today’s commercial systems can limit deployment. Herein, we show that while the availability of Ir should not impede deployment in the near term, the inelasticity of the Ir commodity price is cause for immediate concern. Here we emphasize that diversifying catalyst materials, even with other precious metals, can reduce system costs and mitigate supply chain risk. Furthermore, we analyze the trade-offs between catalyst capital cost and catalyst activity for a range of operating conditions (i.e., capacity factor, electricity price). The framework presented herein is a first step toward establishing performance targets (i.e., activity, stability, material cost) for reduced precious metal and non-precious metal catalysts as a function of PEM electrolyzer operating conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Watershed response of the Feather River Basin, California, United States of America to future climate changes

Increasing mean annual temperatures under climate change are expected to reduce seasonal snowpack, increase evapotranspiration (ET), and alter summer baseflow in headwater watersheds worldwide. Strong regional variability in hydrologic responses highlights the need for catchment-scale, physically based models to assess future flood risk and water availability. This study examines climate-driven changes in the hydrologic response of the Upper Feather River watershed in the Sierra Nevada Mountains, California. Four priority climate models and two representative concentration pathways (RCP4.5 and RCP8.5) are used to evaluate future hydrologic responses of the watershed. Hydrologic processes are simulated using an objectively calibrated Soil and Water Assessment Tool Plus model for a historical baseline (1986–2005) and a future period 2070–2099), driven by observed and projected precipitation and temperature. Results indicate a declining contribution of snowfall to annual precipitation, with peak snowfall and water yield shifting 1–3 months earlier. Long-term annual maximum flows are projected to increase considerably, whereas low-flow responses are mixed, with both increases and decreases projected by the end of the century. These findings highlight the need for adaptive watershed management to enhance flood protection, water storage, and drought resilience. Future water resource planning should also account for one-to-three-month shifts in peak water yield and surface runoff due to changes in snowmelt timing and a lower snowfall-to-rainfall ratio under climate change. The modeling framework and insights are transferable to other snow-dominated headwater watersheds experiencing climate-driven change.

Tigabu, T [UC Davis]↗

Reactivity-initiated accidents in two pressurized water reactor high burnup core designs

Here, this paper presents a safety analysis of two proposed core loadings for 24-month Pressurized Water Reactor (PWR) fuel cycles. This analysis focuses on reactivity-initiated accidents (RIAs) and evaluates core safety performance impacts of rod-averaged burnup limits up to 75 GWD/MTU and less than 7 % enriched UO 2 . The capabilities of Polaris, PARCS, and RELAP5-3D are leveraged to evaluate the core neutronic and thermal–hydraulic behavior for normal-operation, uncontrolled control rod withdrawal (CRW) transients, and control rod ejection (CRE) accidents. The two core designs are compared to identify features of realistic high burnup/extended enrichment core design approaches which have significant safety impact, identify experimental data needs for high-fidelity predictive modeling, and provide recommendations for future high burnup core designs. The first core design evaluated in this study was developed by Southern Nuclear Company and used an ZrB 2 Integral Fuel Burnable Absorber (IFBA) and B 4 C Wet-Annular Burnable Absorber (WABA)-based burnable poison strategy. The second core design assessed in this work used a Gd 2 O 3 -doped UO 2 burnable poison, similar to that used in boiling water reactors or French PWRs. Results indicate that fuel thermal limits are maintained for limiting CRW and hot full power (HFP) CRE transients. Cladding failure is predicted for the highest energy deposition rods in each core during limiting hot zero power (HZP) CRE accidents (where maximum radially averaged enthalpy exceeds 120 cal/g), though licensing may be permissible with a limited number of failed rods. While concerns exist regarding high critical boron concentration during steady state for the IFBA core and large plenum pressures for the gadolinia core design, the analysis demonstrates adequate safety performance during limiting RIA accident scenarios for two representative high burnup core designs. Design changes limiting plenum pressures and implementation of accident tolerant fuel (ATF) cladding features which minimize hydriding and susceptibility to pellet-cladding mechanical interaction (PCMI) are recommended for future high burnup fuel concepts. To support the technical basis for burnup limit increases, high-fidelity fuel performance models are needed to address physical effects not considered in this analysis, and high burnup irradiated fuel tests are required to extend applicability of the fuel failure limits and validate existing and future models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electrolyzer and Fuel Cell Recycling for a Circular Hydrogen Economy

Abstract Electrolyzers and fuel cells will be crucial for achieving global clean hydrogen and industrial decarbonization goals. However, the nascent clean hydrogen sector faces uncertainties around material supply chains and technology end‐of‐life management. This work aims to guide the transition to a circular hydrogen economy by using process modeling, techno‐economic analysis, and life cycle assessment to evaluate the material cost, energy use, greenhouse gas (GHG) emissions, toxicity, and water use of five potential recycling strategies for proton exchange membrane electrolyzers (PEMWE) and fuel cells (PEMFC). Hydrometallurgy, acid dissolution, and electrochemical dissolution are shown to offer 2–7 times improvement across all assessed metrics relative to the manufacturing of PEMWE and PEMFC from raw materials. Recycling can also lower the raw material demand, material cost, energy use, and GHG emissions associated with PEMWE and PEMFC deployment in the United States in 2050 by 23%, 19%, 21%, and 16%, respectively. This study provides key insights into the costs, benefits, and complexities of recycling strategies for PEMWE and PEMFC, aiding the development of a circular economy that is synergistic with clean hydrogen deployment.

08 HYDROGEN↗

Chemostatic concentration–discharge behaviour observed in a headwater catchment underlain with discontinuous permafrost

Concentration–discharge dynamics were evaluated in a small (~ 2.25 km2) headwater catchment underlain with discontinuous permafrost on the Seward Peninsula of western Alaska. A large storm, during which 48 mm of rain fell over a 24-h period, enabled the evaluation of solute concentration–discharge response to a sizeable hydrological event, while water stable isotopes enabled an appraisal of the contributions of event water. Under normal catchment conditions, chemostatic behaviour was observed for solutes typically derived from mineral weathering (e.g. calcium, magnesium, sodium and silica). The chemostatic behaviour observed for most solutes under normal catchment conditions indicated that catchment storage and residence times are sufficiently long for many solute generating reactions to approach equilibrium. Following the storm however, most solutes exhibited dilutive and highly variable behaviour. This likely indicated the exceedance of a discharge threshold where chemostatic behaviour could no longer be maintained for most solutes. Dissolved organic carbon and silica were the only solutes monitored to exhibit chemostatic behaviour during all time periods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of the BEAVRS benchmark using VERA

The Virtual Environment for Reactor Applications (VERA) is being developed by the Consortium for the Advanced Simulation of Light Water Reactors (CASL). Here, VERA is used to perform the Benchmark for Evaluation and Validation of Reactor Simulations (BEAVRS), which provides two cycles’ worth of operating power history, along with a full, detailed description of the geometry, and measured data. Cycle 1 and 2 are simulated with VERA and the results are compared to the measured zero power physics tests, critical boron concentration, and flux maps.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Water vapor oxidation behaviors of nuclear graphite IG-110 for a postulated accident scenario in high temperature gas-cooled reactors

Water leakage in accidental conditions of high temperature gas-cooled reactors is one of the most critical problems that can compromise the integrity of different nuclear components. In this study, oxidation behaviors of nuclear graphite IG-110 in water ingress accidental conditions were investigated. Mass loss and oxidation rates were evaluated after oxidation tests at temperatures up to 1400 °C in an Ar-20 vol% H 2 O mixed atmosphere. The activation energy decreased from 318.6 to 148.9 kJ/mol with temperature, indicating two different oxidation regimes. The cross-sections of the oxidized samples were systematically characterized. The corresponding logarithmic porosity profiles showed a temperature dependency. Pore formation moved toward near-surface regions with increasing temperature and preferential binder oxidation, with filler particle degradation. Furthermore, oxidant concentration profiles and oxidation depths were estimated using a theoretical model and compared with the experimental results. This work provides important benchmark data and safety analysis guidance for the accident scenario in high temperature gas-cooled reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Techno-economic feasibility of geothermal energy production using inactive oil and gas wells for district heating and cooling systems in Tuttle, Oklahoma

Oil and gas wells have been drilled in the United States and often encounter hot co-produced water possibly suitable for geothermal direct-use applications. Here this study evaluated geothermal resources, heating and cooling demand, and techno-economic potential of four oil and gas wells repurposed for geothermal energy production to serve two public schools and 250 nearby houses in Tuttle, Oklahoma, USA. Subsurface geology in the study area primarily consists of Permian to Mississippian sandstone and limestone formations approximately from 2 km to 3.5 km depth. With a geothermal gradient of 25.3 °C/km, the temperature of geothermal energy production was estimated as 68.2 °C at 2.1 km. The potential of calcite scaling within boreholes and pipes was minimal. Using the characterized reservoir properties, techno-economic analyses were conducted for evaluating levelized costs of geothermal energy production for direct-use heating and cooling and district heating systems with five different production scenarios. Heating and cooling demand in two schools and 250 houses and additional 0.3 MW and 0.6 MW base heating loads for potential geothermal direct-use applications in the study area were also incorporated in the modeling. Results indicated that the levelized cost of heating of geothermal district heating systems utilizing existing wells were significantly lower than those of conventional geothermal energy systems that include well drillings. The geothermal energy production with doublet and quartet configurations was generally sufficient to supply total annual heating demand in the district, while a peaking boiler was used to supply peak loads. Doublet configurations showed higher production temperature with a lower thermal drawdown than the quartet configurations. The doublet system at 2.1 km production depth with 9.3 kg/s flow rate represented the optimal levelized cost of $71/MWh and 91.2% utilization factor. These results imply that the Tuttle geothermal district heating system is techno-economically feasible and comparable to geothermal district heating systems in the United States and the regional natural gas rate for residentials by recycling inactive oil and gas wells with no drillings.

15 GEOTHERMAL ENERGY↗

Climate-extreme modeling framework for sustainable flood management in the Arabian Peninsula

Evaluating extreme precipitation events (EPEs) is essential for building climate-resilient water management strategies, but it remains a major challenge in ungauged basins. Using the 26,070 km 2 Wadi al-Rummah basin in central Saudi Arabia as a case study, we developed an alternative, reliable, cost-effective satellite-based framework that combines empirically derived EPE thresholds, imagery-calibrated 2D hydrodynamic modeling, GRACE water-storage diagnostics, and bias-corrected CMIP6 projections to assess flood hazards and recharge potential under current and future climate scenarios in ungauged basins. The integrated approach and the resulting findings followed four key steps: (1) Identified a 22.5 mm EPE threshold, the 80th percentile of 3-day GPM/IMERG rainfall (2000–2024), aligned with flood-triggering events (Nov 2018: 23–28 mm; Apr, 2023: 42 mm); (2) Developed and calibrated a RiverFlow2D model using Sentinel-2 and PlanetScope imagery for the November 2018 flood, accurately reproducing flood depth and extent (RMSE ≤0.31 m; fuzzy-Dice ≥0.91), and estimating runoff (41 %), infiltration (25 %), and evaporation (34 %); (3) Independently validated the model with the April 2023 event (RMSE ≤0.35 m; fuzzy-Dice ≥0.86); (4) Conducted climate projections (2025–2100) from five bias-corrected NEX-GDDP CMIP6 models that revealed a 34 % increase in EPE intensity under SSP2-4.5 and 48 % under SSP5-8.5 scenarios, relative to 20th-century baselines. Our findings indicate that while intensifying extremes in the 21st century increase flood risk, the results highlight the potential for episodic recharge if effective retention strategies are employed, and offer a transferable model for climate-informed planning in data-scarce arid regions.

CMIP6↗