Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

A chemical kinetic mechanism for combustion and flame propagation of CH 2 F 2 /O 2 /N 2 mixtures

Here in this work, we compiled and evaluated rate expressions for reactions relevant to the decomposition and combustion of CH 2 F 2 (difluoromethane, refrigerant R-32) in CH 2 F 2 /O 2 /N 2 flames. The recommended values have been used in premixed flame calculations, reported elsewhere, to model experimentally derived burning velocities determined using a constant volume spherical flame method. In this work, we also provide a detailed description of the reaction pathways for decomposition and combustion of CH 2 F 2 . This work is part of a larger effort at NIST to characterize and predict the flammability of new refrigerant working fluids and their blends for consideration as replacements of current refrigerants with high global warming potentials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Near‐UV laser treatment of extrinsic dental enamel stains

Abstract Background and Objectives The selective ablation of extrinsic dental enamel stains using a 400‐nm laser is evaluated at several fluences for completely removing stains with minimal damage to the underlying enamel. Study Design/Materials and Methods A frequency‐doubled Ti:sapphire laser (400‐nm wavelength, 60‐nanosecond pulse duration, 10‐Hz repetition rate) was used to treat 10 extracted human teeth with extrinsic enamel staining. Each tooth was irradiated perpendicular to the surface in a back‐and‐forth motion over a 1‐mm length using an ∼300‐µm‐diam 10th‐order super‐Gaussian beam with fluences ranging from 0.8 to 6.4 J/cm 2 . Laser triangulation determined stain depth and volume removed by measuring 3D surface images before and after irradiation. Scanning electron microscopy evaluated the surface roughness of enamel following stain removal. Fluorescence spectroscopy measured spectra of unbleached and photobleached stains in the spectral range of 600–800 nm. Results Extrinsic enamel stains are removed with laser fluences between 0.8 and 6.4 J/cm 2 . Stains removed on sound enamel leave behind a smooth enamel surface. Stain removal in areas with signs of earlier cariogenic acid attacks resulted in isolated and randomly located laser‐induced, 50‐µm‐diam enamel pits. These pits contain 0.5‐µm diam, smooth craters indicative of heat transfer from the stain to the enamel and subsequent melting and water droplet ejection. Ablation stalling of enamel stains is typically observed at low fluences (<3 J/cm 2 ) and is accompanied by a drastic reduction in porphyrin fluorescence from the Soret band. Conclusion Laser ablation of extrinsic enamel stains at 400 nm is observed to be most efficient above 3 J/cm 2 with minimal damage to the underlying enamel. Unsound underlying enamel is also observed to be selectively removed after irradiation. Lasers Surg. Med. 44:339–345, 2012. © 2012 Wiley Periodicals, Inc.

enamel melting↗

Revisiting the Kinematics of the Cylinder Test

The cylinder expansion experiment is a well-established performance test for condensed explosives that is utilized routinely to determine pressure-energy-volume relationships for detonation products. The modern cylinder test employs optical interferometric techniques to measure velocity, as opposed to older realizations where streak cameras were commonplace. Despite their widespread use, questions sometimes remain as to what kind of data the velocity diagnostics in a cylinder test provide along with how to interpret such measurements and relate them to physical quantities of interest. Here in this study, equations are derived that fully describe the kinematics of the cylinder wall during expansion. These equations are then applied to experimental as well as synthetic data generated via a hydrodynamic simulation in order to verify the mathematical framework developed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Topological fermion condensates from anomalies

We show that a class of fermion theory formulated on a compact, curved manifold will generate a condensate whose magnitude is determined only by the volume and Euler characteristic of the space. The construction requires that the fermions be treated as Kahler-Dirac fields and the condensate arises from an anomaly associated with a U(1) global symmetry which is subsequently broken to a discrete subgroup. Remarkably the anomaly survives under discretization of the space which allows us to compute the condensate on an arbitrary triangulation. The results, being topological in character, should hold in a wide range of gravitationally coupled fermion theories both classical and quantum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hydro-mechanically coupled finite-element analysis of the stability of a fractured-rock slope using the equivalent continuum approach: a case study of planned reservoir banks in Blaubeuren, Germany

Construction works associated with the building of reservoirs in mountain areas can damage the stability of adjacent valley slopes. Seepage processes caused by the filling and drawdown operations of reservoirs also affect the stability of the reservoir banks over time. The presented study investigates the stability of a fractured-rock slope subjected to seepage forces in the lower basin of a planned pumped-storage hydropower (PSH) plant in Blaubeuren, Germany. The investigation uses a hydro-mechanically coupled finite-element analyses. For this purpose, an equivalent continuum model is developed by using a representative elementary volume (REV) approach. To determine the minimum required REV size, a large number of discrete fracture networks are generated using Monte Carlo simulations. These analyses give a REV size of 28 × 28 m, which is sufficient to represent the equivalent hydraulic and mechanical properties of the investigated fractured-rock mass. The hydro-mechanically coupled analyses performed using this REV size show that the reservoir operations in the examined PSH plant have negligible effect on the adjacent valley slope.

58 GEOSCIENCES↗

Methane adsorption on various metal-organic frameworks and determination of the average adsorption heats at supercritical temperatures and pressures

Adsorption of methane on three samples of metal-organic framework structures (MOF), which contain copper, aluminum or zinc atoms, was measured at temperatures ranging from 303 to 333 K and pressures up to 40 MPa using a precise volumetric-gravimetric unit. The determined values of adsorption volumes and characteristic energies served to evaluate the average heats of adsorption, which were compared to the average isosteric heats of adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of autogenous shrinkage-induced microcracks in concrete from 3D images

A new image analysis procedure for quantifying microcracks from three-dimensional (3D) X-ray microCT images of concrete is presented. The method separates microcracks from air voids and aggregates by combining filtering and morphological operations. It was applied to study the effects of supplementary cementitious materials (SCMs) and curing age on autogenous shrinkage-induced microcracks in low w/b ratio concretes, and to determine the representative elementary volume (REV) for various properties of microcracks and air voids. Results showed that slag and silica fume significantly increased autogenous shrinkage and related microcracking. These SCMs increased volume fraction, width, length, dendritic density, anisotropy, and connectivity of microcracks, but decreased specific surface and tortuosity. Similar trends were observed with age. Comparison between 3D and 2D measurements was made. REV analysis showed that a sampling volume of ~20 × 20 × 25 mm{sup 3} is sufficient for characterising most parameters of autogenous shrinkage microcracks and air voids in concrete.

36 MATERIALS SCIENCE↗

Influence of O 2 / N 2 oxidizer blends on soot formation and radiative heat flux in PMMA-air 2D slab burner for understanding hybrid rocket combustion

The focus of this study is to establish a correlation between the flame to fuel incident radiative heat flux (RHF) in 1D steady-state diffusion flames to non-intrusively measured RHF in 2D slab burner experiments for a range of O 2 /N 2 oxidizer blends. Slab burner experiments are conducted for a range of increasing O 2 concentrations from 17% to 100% in the oxidizer stream. Non-intrusive two-color pyrometry is used to determine flame temperature, soot volume fraction, and flame to fuel surface RHF. Measurements and modeling confirm soot volume fraction attains a local maximum for an O 2 concentration of 45%. Low-strain diffusion flame modeling shows the reason for the local maximum is the relative location of the soot formation/nucleation fronts relative to oxidation which decreases with increasing O 2 concentration. Overall good agreement between modeling and measurements of radiative heat flux to the fuel is observed for the fuel and range of O 2 concentrations considered. Furthermore, these results demonstrate the viability of using flamelet modeling approaches for describing hybrid rocket motors.

2D slab burner↗

Absorption of wireless radiation in the child versus adult brain and eye from cell phone conversation or virtual reality

Highlights: • More cell phone radiation is absorbed by children's inner brain tissues than adults’. • Children's radiofrequency radiation exposure should be reduced. • Further research to evaluate the risks to the eye from use of VR is urgently needed. • It is biologically relevant and feasible to reduce the standards’ averaging volume. • Current methods to determine wireless device compliance should be revised. Children's brains are more susceptible to hazardous exposures, and are thought to absorb higher doses of radiation from cell phones in some regions of the brain. Globally the numbers and applications of wireless devices are increasing rapidly, but since 1997 safety testing has relied on a large, homogenous, adult male head phantom to simulate exposures; the “Standard Anthropomorphic Mannequin” (SAM) is used to estimate only whether tissue temperature will be increased by more than 1 Celsius degree in the periphery. The present work employs anatomically based modeling currently used to set standards for surgical and medical devices, that incorporates heterogeneous characteristics of age and anatomy. Modeling of a cell phone held to the ear, or of virtual reality devices in front of the eyes, reveals that young eyes and brains absorb substantially higher local radiation doses than adults’. Age-specific simulations indicate the need to apply refined methods for regulatory compliance testing; and for public education regarding manufacturers' advice to keep phones off the body, and prudent use to limit exposures, particularly to protect the young.

54 ENVIRONMENTAL SCIENCES↗

Experimental study on thermophoretic deposition of soot particles in laminar diffusion flames along a solid wall in microgravity

Soot deposition process in diffusion flames along a solid wall has been investigated experimentally under a microgravity environment. An ethylene (C{sub 2}H{sub 4}) diffusion flame was formed around a cylindrical rod-burner with the surrounding air velocities of V{sub a} = 2.5, 5, and 10 cm/s, the oxygen concentration of 35%, and the burner wall temperature of 300 K. A laser extinction method was adopted to measure the distribution of soot volume fraction. The experiments determined the trace of maximum soot concentration together with the relative distance of the trace of flame. Results showed that the distance was about 2-5 mm. As the surrounding air velocity increased, the region of the soot particle distribution moved closer to the burner wall. The soot particles near the flame zone tended to move away from the flame zone because of the thermophoretic force and to concentrate at a certain narrow region inside the flame. Because of the simultaneous effects of convection and the thermophoresis, soot particles finally adhered to the burner wall. It has been found that there existed an optimal air velocity for the early deposition of soot on the furnace wall. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Technical assessment of compressed hydrogen storage tank systems for automotive applications.

The performance and cost of compressed hydrogen storage tank systems has been assessed and compared to the U.S. Department of Energy (DOE) 2010, 2015, and ultimate targets for automotive applications. The on-board performance and high-volume manufacturing cost were determined for compressed hydrogen tanks with design pressures of 350 bar ({approx}5000 psi) and 700 bar ({approx}10,000 psi) capable of storing 5.6 kg of usable hydrogen. The off-board performance and cost of delivering compressed hydrogen was determined for hydrogen produced by central steam methane reforming (SMR). The main conclusions of the assessment are that the 350-bar compressed storage system has the potential to meet the 2010 and 2015 targets for system gravimetric capacity but will not likely meet any of the system targets for volumetric capacity or cost, given our base case assumptions. The 700-bar compressed storage system has the potential to meet only the 2010 target for system gravimetric capacity and is not likely to meet any of the system targets for volumetric capacity or cost, despite the fact that its volumetric capacity is much higher than that of the 350-bar system. Both the 350-bar and 700-bar systems come close to meeting the Well-to-Tank (WTT) efficiency target, but fall short by about 5%.

03 NATURAL GAS↗

High Dose-Rate Intracavitary Brachytherapy for Cervical Carcinomas With Lower Vaginal Infiltration

Purpose: This report presents the clinical applications of an automated treatment-planning program of high-dose-rate intracavitary brachytherapy (HDR-ICBT) for advanced uterine cervical cancer infiltrating the parametrium and the lower vagina. Methods and Materials: We adopted HDR-ICBT under optimized dose distribution for 22 cervical cancer patients with tumor infiltration of the lower half of the vagina. All patients had squamous cell carcinoma with International Federation of Gynecology and Obstetrics clinical stages IIB-IVA. After whole pelvic external beam irradiation with a median dose of 30.6 Gy, a conventional ICBT was applied as 'pear-shaped' isodose curve. Then 3-4 more sessions per week of this new method of ICBT were performed. With a simple determination of the treatment volume, the cervix-parametrium, and the lower vagina were covered automatically and simultaneously by this program, that was designated as 'utero-vaginal brachytherapy'. The mean follow-up period was 87.4 months (range, 51.8-147.9 months). Results: Isodose curve for this program was 'galaxy-shaped'. Five-year local-progression-free survival and overall survival rates were 90.7% and 81.8%, respectively. Among those patients with late complications higher than Grade 2 Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer morbidity score, only one (4.5%) developed severe proctitis. Conclusions: Because of the favorable treatment outcomes, this treatment-planning program with a simplified target-volume based dosimetry was proposed for cervical cancer with lower vaginal infiltration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Normal Tissue Reactions in Head-and-Neck Cancer Patients Treated With IMRT: Influence of Dose and Association With Genetic Polymorphisms in DNA DSB Repair Genes

Purpose: To investigate the association between dose-related parameters and polymorphisms in DNA DSB repair genes XRCC3 (c.-1843A>G, c.562-14A>G, c.722C>T), Rad51 (c.-3429G>C, c.-3392G>T), Lig4 (c.26C>T, c.1704T>C), Ku70 (c.-1310C>G), and Ku80 (c.2110-2408G>A) and the occurrence of acute reactions after radiotherapy. Materials and Methods: The study population consisted of 88 intensity-modulated radiation therapy (IMRT)-treated head-and-neck cancer patients. Mucositis, dermatitis, and dysphagia were scored using the Common Terminology Criteria (CTC) for Adverse Events v.3.0 scale. The population was divided into a CTC0-2 and CTC3+ group for the analysis of each acute effect. The influence of the dose on critical structures was analyzed using dose-volume histograms. Genotypes were determined by polymerase chain reaction (PCR) combined with restriction fragment length polymorphism or PCR-single base extension assays. Results: The mean dose (D{sub mean}) to the oral cavity and constrictor pharyngeus (PC) muscles was significantly associated with the development of mucositis and dysphagia, respectively. These parameters were considered confounding factors in the radiogenomics analyses. The XRCC3c.722CT/TT and Ku70c.-1310CG/GG genotypes were significantly associated with the development of severe dysphagia (CTC3+). No association was found between the investigated polymorphisms and the development of mucositis or dermatitis. A risk analysis model for severe dysphagia, which was developed based on the XRCC3c.722CT/TT and Ku70c.-1310CG/GG genotypes and the PC dose, showed a sensitivity of 78.6% and a specificity of 77.6%. Conclusions: The XRCC3c.722C>T and Ku70c.-1310C>G polymorphisms as well as the D{sub mean} to the PC muscles were highly associated with the development of severe dysphagia after IMRT. The prediction model developed using these parameters showed a high sensitivity and specificity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Analysis of Extracapsular Extension of Metastatic Lymph Nodes and its Significance in Radiotherapy Planning in Head and Neck Squamous Cell Carcinoma

Purpose: We performed a histopathologic analysis to assess the extent of the extracapsular extension (ECE) beyond the capsule of metastatic lymph nodes (LN) in head and neck cancer to determine appropriate clinical target volume (CTV) expansions. Methods and Materials: All tumor-positive LN of 98 patients who underwent a neck dissection with evidence of ECE in at least one LN were analyzed by a single pathologist. The largest diameters of all LN, and in the case of ECE, the maximal linear distance, from the capsule to the farthest extent of tumor or tumoral reaction were recorded. Results: A total of 231 LN with ECE and 200 tumor-positive LN without ECE were analyzed. The incidence of ECE was associated with larger LN size (p < 0.001). Of all tumor-positive LN with a diameter of < 10 mm or < 5 mm, 105/220 (48%) nodes or 17/59 (29%) nodes, respectively, showed evidence of ECE. The mean and median extent values of ECE were 2 and 1 mm (range, 1-10 mm) and the ECE was <= 5 mm in 97% and <= 3 mm in 91% of the LN, respectively. Overall, the extent of ECE was significantly correlated with larger LN size (Spearman's correlation coefficient = 0.21; p = 0.001). Conclusions: The incidence of ECE is associated with larger LN size. However, ECE is found in a substantial number of LN with a diameter of < 10 mm. The use of 10-mm CTV margins around the gross tumor volume seems appropriate to account for ECE in radiotherapy planning of head and neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative Seroma Formation After Intraoperative Radiotherapy Using Low-Kilovoltage X-Rays Given During Breast-Conserving Surgery

Purpose: To determine the frequency and volume of seroma after breast-conserving surgery (BCS) with or without intraoperative radiotherapy (IORT). Methods and Materials: Seventy-one patients with 73 breast cancers (IORT group) treated with IORT (20 Gy Intrabeam) as a boost during BCS were compared with 86 patients with 88 breast tumors (NO-IORT group) treated without IORT. Clinical examination and measurement of seroma volume on treatment-planning CT (CT-seroma) was done at median interval of 35 days after BCS. Results: Seroma were found on palpation in 37 patients (23%) and on CT in 105 patients (65%; median volume, 26.3 mL). Interval between BCS and CT was significantly shorter in patients with palpable seroma (median, 33 days) or CT-seroma (33 days) compared with those with no palpable seroma (36.5 days; p = 0.027) or CT-seroma (52 days, p < 0.001). The rate of palpable seroma was not different (IORT n = 17, 23%; NO-IORT n = 20, 23%; p = 0.933), whereas fewer patients required puncture in the IORT group [3 (4%) vs. 10 (11%)]. In contrast, more patients showed CT-seroma after IORT (IORT n = 59, 81%; NO-IORT n = 46, 52%; p < 0.001). The interval between BCS and CT was significantly shorter in patients with IORT as compared with the NO-IORT patients (median, 33 days vs. 41.5 days; p = 0.036). Conclusion: Intraoperative radiotherapy with low-kilovoltage X-rays during BCS is not associated with an increased rate of palpable seroma or seroma requiring treatment. The rate of seroma formation on CT was higher after IORT compared with the NO-IORT group, which might be because of the shorter interval between BCS and CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Standardized Uptake Value-Based Positron Emission Tomography and Computed Tomography Target Volumes in Esophageal Cancer Patients Undergoing Radiotherapy

Purpose: To study various standardized uptake value (SUV)-based approaches to ascertain the best strategy for delineating metabolic tumor volumes (MTV). Methods and Materials: Twenty-two consecutive previously treated esophageal cancer patients with positron emission tomography (PET) imaging and computed tomography (CT)-based radiotherapy plans were studied. At the level of the tumor epicenter, MTVs were delineated at 11 different thresholds: SUV {>=}2, {>=}2.5, {>=}3, {>=}3.5 (SUV{sub n}); {>=}40%, {>=}45%, and {>=}50% of the maximum (SUV{sub n%}); and mean liver SUV + 1, 2, 3, and 4 standard deviations (SUV{sub Ln{sigma}}). The volume ratio and conformality index were determined between MTVs, and the corresponding CT/endoscopic ultrasound-based gross tumor volume (GTV) at the epicenter. Means were analyzed by one-way analysis of variance for repeated measures and further compared using a paired t test for repeated measures. Results: The mean conformality indices ranged from 0.33 to 0.48, being significantly (p < 0.05) closest to 1 at SUV{sub 2.5} (0.47 {+-} 0.03) and SUV{sub L4{sigma}} (0.48 {+-} 0.03). The mean volume ratios ranged from 0.39 to 2.82, being significantly closest to 1 at SUV{sub 2.5} (1.18 {+-} 0.36) and SUV{sub L4{sigma}} (1.09 {+-} 0.15). The mean value of the SUVs calculated using the SUV{sub L4{sigma}} approach was 2.4. Conclusions: Regardless of the SUV thresholding method used (i.e., absolute or relative to liver mean), a threshold of approximately 2.5 yields the highest conformality index and best approximates the CT-based GTV at the epicenter. These findings may ultimately aid radiation oncologists in the delineation of the entire GTV in esophageal cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulated Arc-Based Hypofractionated Stereotactic Radiotherapy for the Treatment of Selected Intracranial Arteriovenous Malformations: Dosimetric Report and Early Clinical Experience

Purpose: To evaluate, with a dosimetric and clinical feasibility study, RapidArc (a volumetric modulated arc technique) for hypofractionated stereotactic radiotherapy treatment of large arteriovenous malformations (AVMs). Methods and Materials: Nine patients were subject to multimodality imaging (magnetic resonance, computed tomography, and digital subtraction angiography) to determine nidus and target volumes, as well as involved organs at risk (optical structures, inner ear, brain stem). Plans for multiple intensity-modulated arcs with a single isocenter were optimized for a fractionation of 25 Gy in 5 fractions. All plans were optimized for 6-MV photon beams. Dose-volume histograms were analyzed to assess plan quality. Delivery parameters were reported to appraise technical features of RapidArc, and pretreatment quality assurance measurements were carried out to report on quality of delivery. Results: Average size of AVM nidus was 26.2 cm{sup 3}, and RapidArc plans provided complete target coverage with minimal overdosage (V{sub 100%} = 100% and V{sub 110%} < 1%) and excellent homogeneity (<6%). Organs at risk were highly spared. The D{sub 1%} to chiasm, eyes, lenses, optic nerves, and brainstem (mean {+-} SD) was 6.4 {+-} 8.3, 1.9 {+-} 3.8, 2.3 {+-} 2.2, 0.7 {+-} 0.9, 4.4 {+-} 7.2, 12.2 {+-} 9.6 Gy, respectively. Conformity index (CI{sub 95%}) was 2.2 {+-} 0.1. The number of monitor units per gray was 277 {+-} 45, total beam-on time was 2.5 {+-} 0.3 min. Planning vs. delivery {gamma} pass rate was 98.3% {+-} 0.9%. None of the patients developed acute toxicity. With a median follow-up of 9 months, 3 patients presented with deterioration of symptoms and were found to have postradiation changes but responded symptomatically to steroids. These patients continue to do well on follow-up. One patient developed headache and seizures, which was attributed to intracranial bleed, confirmed on imaging. Conclusion: Hypofractionated stereotactic radiotherapy can be successfully delivered using the RapidArc form of volumetric arc technology for intracranial AVMs. The quality of delivery and calculated parameters are in agreement with each other and are in line with published reports for other sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-based Preplanning Using CT and MRI Data Fusion in Patients With Cervical Cancer Treated With 3D-based Brachytherapy: Feasibility and Accuracy Study

Purpose: Magnetic resonance imaging (MRI)-assisted radiation treatment planning enables enhanced target contouring. The purpose of this study is to analyze the feasibility and accuracy of computed tomography (CT) and MRI data fusion for MRI-based treatment planning in an institution where an MRI scanner is not available in the radiotherapy department. Methods and Materials: The registration inaccuracy of applicators and soft tissue was assessed in 42 applications with CT/MRI data fusion. The absolute positional difference of the center of the applicators was measured in four different planes from the top of the tandem to the cervix. Any inaccuracy of registration of soft tissue in relation to the position of applicators was determined and dose-volume parameters for MRI preplans and for CT/MRI fusion plans with or without target and organs at risk (OAR) adaptation were evaluated. Results: We performed 6,132 measurements in 42 CT/MRI image fusions. Median absolute difference of the center of tandem on CT and MRI was 1.1 mm. Median distance between the center of the right ovoid on CT and MRI was 1.7 and 1.9 mm in the laterolateral and anteroposterior direction, respectively. Corresponding values for the left ovoid were 1.6 and 1.8 mm. Rotation of applicators was 3.1 Degree-Sign . Median absolute difference in position of applicators in relation to soft tissue was 1.93, 1.50, 1.05, and 0.84 mm in the respective transverse planes, and 1.17, 1.28, 1.27, and 1.17 mm in selected angular directions. The dosimetric parameters for organs at risk on CT/MRI fusion plans without OAR adaptation were significantly impaired whereas the target coverage was not influenced. Planning without target adaptation led to overdosing of the target volume, especially high-risk clinical target volume - D{sub 90} 88.2 vs. 83.1 (p < 0.05). Conclusions: MRI-based preplanning with consecutive CT/MRI data fusion can be safe and feasible, with an acceptable inaccuracy of soft tissue registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗