Pressure distribution along the AGS vacuum chambers with new types of pump out conduits

The AGS HEBT and ring vacuum system is monitored by the discharge current of the magnet ion pumps, which is proportional to the pressure at the inlet port of these ion pumps. The discharge current is measured and suitably calibrated to indicate the ion pump pressure. In order to calculate the vacuum chamber pressure from the ion pump pressure, a detailed analysis is essential to compute their difference in different scenarios. Such analysis has been carried out numerically in the past for the system with the older type of pump out conduits, and similar analysis using FEM in ANSYS is presented in this paper with the newer type of pump out conduit.

43 PARTICLE ACCELERATORS↗

Carbon Nanotube Vacuum Gauges Utilizing Long, Dissipative Tubes

CNT Vacuum Gauges: a) have a broad range of pressure response from 760 - 10(exp -6) Torr. b) have current changes approx. 100's nA in high vacuum regime (10(exp -6) Torr) and sensitivity increases with power and substrate removal. c) have a negative dR/dT (TCR negative) where a thermal hopping energy E(sub a) was determined to be approx. 40 meV. d) have compatible fabrication requirements for their integration with micromachined structures. e) can be operated at low power (nW - micro-W). f) have an active device region footprint of < 10 sq microns. g) are non-intrusive due to small size and passive operation.

nanotube sensors↗

DEVELOPMENT AND DEMONSTRATION OF A SUPERCRITICAL HELIUM-COOLED CRYOGENIC VISCOUS COMPRESSOR PROTOTYPE FOR THE ITER VACUUM SYSTEM

As part of the vacuum system for the ITER fusion project, a cryogenic viscouscompressor (CVC) is being developed to collect hydrogenic exhaust gases from the toruscryopumps and compress them to a high enough pressure by regeneration for pumping tothe tritium reprocessing facility. Helium impurities that are a byproduct of the fusionreactions pass through the CVC and are pumped by conventional vacuum pumps andexhausted to the atmosphere. Before the development of a full-scale CVC, a representative,small-scale test prototype was designed, fabricated, and tested. With cooling provided bycold helium gas, hydrogen gas was introduced into the central column of the test prototypepump at flow rates between 0.001 g/s and 0.008 g/s. Based on the temperatures and flowrates of the cold helium gas, different percentages of hydrogen gas were frozen to the column surface wall as the hydrogen gas flow rate increased. Results from the measured temperatures and pressures will form a benchmark that will be used to judge future heattransfer enhancements to the prototype CVC and to develop a computational fluid dynamicmodel that will help develop design parameters for the full-scale CVC.

08 HYDROGEN↗

Vacuum Chamber Design of NSLS-II Storage Ring

National Synchrotron Light Source II (NSLS II) will be a 3-GeV, 792-meter circumference, 3rd generation synchrotron radiation facility, with ultra low emittance and extremely high brightness. the storage ring has 30 Double-Bend-Achromatic (DBA) cells. in each cell, there are five magnets and chamber girders, and one straight section for insertion devices or Radio Frequency (RF) cavities or injection. Most vacuum chambers are made from extruded aluminum with two different cross sections: one fitted in the dipole magnets, and the other surrounded by multipole magnets. They discuss the layout of the DBA cells, the detailed design of the cell's vacuum chambers, the mounting of the Beam-Position-Monitor (BPM) buttons, discrete absorbers, lumped pumps and the distributed Non-Evaporable Getter (NEG) strips, and describe the fabrication and testing of these prototype cell chambers. The account also details the development of the chamber bakeout process, the NEG stri's supports, and the RF shielded bellows.

43 PARTICLE ACCELERATORS↗

On the modes of evaporation of Si and dopants in vacuum epitaxy procedures

Silicon layers are grown by sublimation molecular beam epitaxy at the rate 1 {mu}m h{sup -1} at temperatures 500-900 deg. C in vacuum at the pressure 10{sup -5} Pa. The possibility of varying the Sb concentration in the Si layers in the range from 10{sup 15} to 10{sup 20} cm{sup -3} by varying the temperature of epitaxy is shown. The potentialities of different modes of vacuum evaporation of Si and dopants are analyzed.

36 MATERIALS SCIENCE↗

Vacuum polarization in Coulomb field revisited

Simplified derivation of Wichmann–Kroll term is presented. The derivation uses two formulas for hypergeometric functions, but otherwise is elementary. It is found that Laplace transform of the vacuum charge density diverges at zero momentum transfer. This divergence has nothing to do with known ultraviolet divergence. The latter is related to the large momentum behavior of the pertinent integral, while the former to the small momentum behavior. When these divergences are removed, the energy shift caused by vacuum polarization for an ordinary hydrogen obtained here is in an exact agreement with the result obtained by Wichmann and Kroll. Also, for muonic hydrogen the result obtained here reasonably agrees with that given in literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vacuum-assisted carbon molecular sieve membrane reactor for non-oxidative ethane dehydrogenation

Non-oxidative ethane dehydrogenation (EDH) is equilibrium-limited and endothermic. Selective hydrogen removal using a gas-permeable membrane within the EDH reaction zone can overcome the thermodynamic equilibrium, enabling higher ethane conversions. Employing vacuum as the permeation driving force, rather than a sweep gas, enhances the industrial viability of membrane reactors by eliminating additional post-reaction separation units. This study presents a membrane reactor that integrates H 2 -permeable carbon molecular sieve (CMS) hollow fiber membranes embedded in a fixed bed of cobalt in a dealuminated beta zeolite (Co@DeAl-BEA) catalyst, utilizing a vacuum to remove hydrogen efficiently. The CMS membrane exhibits high hydrogen permeance and an excellent H 2 /C 2 H 6 separation factor. The membrane reactor significantly enhanced the ethane conversion under reaction conditions comparable to those reported in the literature. A Langmuir-Hinshelwood kinetic rate expression was developed and incorporated into a one-dimensional steady-state reactor model. The experimentally validated model indicates that increasing the number of hollow fibers improves ethane conversion, although ethane loss to the permeate limits the benefit. The contact area between the catalyst and the membrane limits the reactor performance more than the catalytic throughput. Furthermore, we find that the location of the catalyst packing relative to the hollow fiber membranes influences ethane loss and conversion. Higher reactor pressures and inlet ethane flow rates improve space-time yield at the expense of lower ethane conversion. Increasing reactor temperature or packing length promotes both performance metrics. The EDH membrane reactor demonstrated durability over 200 h of continuous operation, maintaining record-low deactivation rates and high ethylene selectivity. Protocols for catalyst regeneration were developed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Natural fibers as promising core materials of vacuum insulation panels

To reduce energy consumption in buildings, this paper investigates the feasibility of using natural fibers as cost-effective, environmentally sustainable core materials for vacuum insulation panels (VIPs). First, a comprehensive experimental study was conducted for 10 potential natural fiber candidates. The thermal conductivities of the 10 natural fiber mats at various vacuum pressures were measured; their compression and morphology properties were quantified. In addition, an analytical model was used to explore the major factors that influence the thermal conductivity of natural fibers as a function of internal air pressure. Results show that recycled cotton, kapok, and bamboo fibers are ideal candidates for VIP core materials; at <0.05 Pa, their thermal conductivities varied between 2 and 4 mW/(m∙K). Furthermore, for some fibers, thermal conductivity was inversely proportional to fiber density. For the selection of fiber materials for VIP cores, the ideal fiber candidate has a small fiber diameter and a low fiber mat density. Based on thermal measurements, even though the internal air pressure of 5 Pa was enough to attain the minimum thermal conductivity, obtaining internal air pressure below 5 Pa is recommended for prolonged service life, considering small leaks of VIP package barrier films and potential off-gassing from fibers. The simulation results predicting the effective thermal conductivities matched the experimental results well. These findings indicate that natural fiber–based VIPs have the potential to be a sustainable, inexpensive alternative to the current technologies in building insulation materials.

36 MATERIALS SCIENCE↗

Advances in understanding vacuum break dynamics in liquid helium-cooled tubes for accelerator beamline applications

Understanding air propagation and condensation following a catastrophic vacuum break in particle accelerator beamlines cooled by liquid helium is essential for ensuring operational safety. This review summarizes experimental and theoretical work conducted in our cryogenics lab to address this issue. Systematic measurements were performed to study nitrogen gas propagation in uniform copper tubes cooled by both normal liquid helium (He I) and superfluid helium (He II). These experiments revealed a nearly exponential deceleration of the gas front, with stronger deceleration observed in He II-cooled tubes. To interpret these results, a one-dimensional (1D) theoretical model was developed, incorporating gas dynamics, heat transfer, and condensation mechanisms. The model successfully reproduced key experimental observations in the uniform tube system. However, recent experiments involving a bulky copper cavity designed to mimic the geometry of a superconducting radiofrequency (SRF) cavity revealed strong anisotropic flow patterns of nitrogen gas within the cavity, highlighting limitations in extrapolating results from simplified tube geometries to real accelerator beamlines. To address these complexities, we outline plans for systematic studies using tubes with multiple bulky cavities and the development of a two-dimensional (2D) model to simulate gas dynamics in these more intricate configurations. As a result, these efforts aim to provide a comprehensive understanding of vacuum breaks in particle accelerators and improve predictive capabilities for their operational safety.

Beamline tube↗

Laser strengthening of additive manufactured edge seal for vacuum insulated glazing with micro-size glass frit

Sealing of glass edge is a key step in developing cost-effective and durable vacuum insulated glazing for the drive towards net-zero energy buildings. In this study, to achieve a high-strength sealing with scalable and low-cost processing, we investigated a novel sealing method based on additive manufacturing and laser process and reported quantitative analysis of the laser assisted method sealing strength and the requirement of vacuum insulation glazing. Micro-size glass frits in printing ink and a continuous-wave laser curing were employed to allow the formation of a hermetic bonding layer with low thermal budget. Controlling various sealing parameters including laser traveling speed, spot diameter, and laser power, the water seepage and mechanical strength of the resulting glass-to-glass bonding were examined. Through the response surface methodology, we identified the optimized sealing condition where the bonding strength reached 5.68 MPa. A comparation of the bonding strength between thermal sealing method and laser-assisted method has been analyzed as well.

42 ENGINEERING↗

Vacuum-free laminated top electrode with conductive tapes for scalable manufacturing of efficient perovskite solar cells

The efficiency of organometal trihalide perovskites (OTP) solar cells have reached that parity of single crystal silicon, and its nature abundant raw material and solution-process capability promise a bright future for commercialization. However, the vacuum based techniques for metal electrode deposition and additional encapsulation layer increase the cost of the perovskite solar cells dramatically and impede their commercialization process. Here, we report a vacuum-free low temperature lamination technique to fabricate the top electrode by commercial conductive tapes (C-tape). The simple fabrication method yields good quality contact and high efficiency device of 12.7%. The C-tapes also encapsulated the devices effectively, resulting in greatly improved device stability. As a result, the combination of lamination of electrodes and encapsulation layers into a single step significantly reduce the cost of device fabrication.

14 SOLAR ENERGY↗

A target vacuum interlock system for Gammasphere.

An interlock system is described that allows volatile targets to be prepared in an evaporator, sealed under vacuum, transported to the {gamma}-array Gammasphere, and inserted into the reaction chamber for experiments, while maintaining a vacuum better than 10{sup -5} torr. The performance of the system is demonstrated for lithium metal targets. A comparison is made between lithium targets covered by a gold evaporation to reduce oxidation and open metal targets transferred in the interlock.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Desorption Postionization Mass Spectrometry of Antibiotic-Treated Bacterial Biofilms using Tunable Vacuum Ultraviolet Radiation

Laser desorption postionization mass spectrometry (LDPI-MS) with 8.0 ? 12.5 eV vacuum ultraviolet synchrotron radiation is used to single photon ionize antibiotics andextracellular neutrals that are laser desorbed both neat and from intact bacterial biofilms. Neat antibiotics are optimally detected using 10.5 eV LDPI-MS, but can be ionized using 8.0 eV radiation, in agreement with prior work using 7.87 eV LDPI-MS. Tunable vacuum ultraviolet radiation also postionizes laser desorbed neutrals of antibiotics and extracellular material from within intact bacterial biofilms. Different extracellular material is observed by LDPI-MS in response to rifampicin or trimethoprim antibiotic treatment. Once again, 10.5 eV LDPI-MS displays the optimum trade-off between improved sensitivity and minimum fragmentation. Higher energy photons at 12.5 eV produce significant parent ion signal, but fragment intensity and other low mass ions are also enhanced. No matrix is added to enhance desorption, which is performed at peak power densities insufficient to directly produce ions, thus allowing observation of true VUV postionization mass spectra of antibiotic treated biofilms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vacuum-Ultraviolet (VUV) Photoionization of Small Methanol and Methanol-Water Clusters

In this work, we report on the vacuum-ultraviolet (VUV) photoionization of small methanol and methanol-water clusters. Clusters of methanol with water are generated via co-expansion of the gas phase constituents in a continuous supersonic jet expansion of methanol and water seeded in Ar. The resulting clusters are investigated by single photon ionization with tunable vacuum-ultraviolet synchrotron radiation and mass analyzed using reflectron mass spectrometry. Protonated methanol clusters of the form (CH3OH)nH+(n = 1-12) dominate the mass spectrum below the ionization energy of the methanol monomer. With an increase in water concentration, small amounts of mixed clusters of the form (CH3OH n(H2O)H+ (n = 2-11) are detected. The only unprotonated species observed in this work are the methanol monomer and dimer. Appearance energies are obtained from the photoionization efficiency (PIE) curves for CH3OH+, (CH3OH)2+, (CH3OH)nH+ (n = 1-9), and (CH3OH)n(H2O)H+ (n = 2-9) as a function of photon energy. With an increasein the water content in the molecular beam, there is an enhancement of photoionization intensity for the methanol dimer and protonated methanol monomer at threshold. These results are compared and contrasted to previous experimental observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chloride modification of vacuum-assisted blade-coated perovskite solar cells and mini-modules in ambient environment

Scalable deposition of perovskite thin films under ambient conditions remains a key challenge for the commercialization of perovskite photovoltaics, primarily due to the difficulty of controlling crystallization kinetics and suppressing non-radiative recombination during film formation. In this work, we present an effective strategy to modulate crystallization kinetics and non-radiative recombination in vacuum-quenched blade-coated perovskite films processed in air using chloride-based additives. By systematically comparing PbCl 2 and 3-chloropropylamine hydrochloride (Cl-PACl), we elucidate how different chloride incorporation pathways influence crystallization behavior and optoelectronic properties. In situ transmission and in situ photoluminescence measurements reveal that PbCl 2 acts as a transient additive that slows intermediate/perovskite phase formation while suppressing non-radiative recombination, leading to improved film quality. In contrast, Cl-PACl introduces additional trap states that deteriorate optoelectronic performance. As a result, PbCl 2 -modified perovskite solar cells achieve a champion power conversion efficiency (PCE) of 24.2% and remarkable operational stability, retaining over 90% of their initial performance after 800 hours of continuous illumination. Furthermore, we successfully scaled the process, fabricating a perovskite mini-module that delivered a champion efficiency of 18.0%. This study underscores the critical importance of coupling vacuum-assisted blade coating with transient additive engineering for achieving high-performance, stable, and scalable perovskite photovoltaics processed in ambient air.

14 SOLAR ENERGY↗

Diamagnetic measurements in the STOR-M tokamak by a flux loop system exterior to the vacuum vessel

Diamagnetic measurements of poloidal beta have been performed in the STOR-M tokamak by a flux loop placed exterior to the vacuum chamber with compensation for the vacuum toroidal field using a nonenclosing coplanar coil, and vibrational compensation from auxiliary coils. It was found that in STOR-M conditions (20% toroidal magnetic field decay over discharge) there is significant influence on the diamagnetic flux measurements from strong residual signals, presumably from image currents being induced by the toroidal field coils, requiring further compensation. A blank (nonplasma) shot is used specifically to eliminate the residual component which is not proportional to the toroidal magnetic field. Data from normal Ohmic discharge operation is presented and calculations of poloidal beta from coil data ({beta}{sub {theta}}{approx}0.5) is found to be in reasonable agreement with the values of poloidal beta obtained from measurements of electron density and Spitzer temperature with neoclassical corrections for trapped electrons. Contributions present in the blank shot (residual) signal and the limitations of this method are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a multipurpose vacuum chamber for serial optical and diffraction experiments with free electron laser radiation

In this paper we present a development of a multipurpose vacuum chamber which primal function is to be used in pump/probe experiments with free electron laser (FEL) radiation. The chamber is constructed for serial diffraction and serial spectroscopy allowing a fast exchange of samples during the measurement process. For the fast exchange of samples, liquid jet systems are used. Both applications, utilizing soft x-ray FEL pulses as pump and optical laser pulses as probe and vice versa are documented. Experiments with solid samples as well as the liquid jet samples are presented. When working with liquid jets, a system of automatically refilled liquid traps for capturing liquids has been developed in order to ensure stable vacuum conditions. Differential pumping stages are placed in between the FEL beamline and the experimental chamber so that working pressure in the chamber can be up to four orders of magnitude higher than the pressure in the FEL beamline.

43 PARTICLE ACCELERATORS↗

Note: Fixture for characterizing electrochemical devices in-operando in traditional vacuum systems

We describe a fixture that allows electrochemical devices to be studied under electrical bias in the type of vacuum systems commonly used in surface science. Three spring-loaded probes provide independent contacts for device operation and the characterization in vacuum or under in situ conditions with reactive gases. We document the robustness of the electrical contacts over large temperature changes and their reliability for conventional electrochemical measurements such as impedance spectroscopy. The optical access provided to the device enables the analysis by many techniques, as we demonstrate using x-ray photoelectron spectroscopy to measure local electrical potentials on a solid-oxide electrolyte device operating at high temperature in near-ambient pressure.