Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tool size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Large-Scale Grid Models: Synthetic Data and Co-Simulation

Power grid modernization and wide-spread distributed energy resource (DER) integration are driving an explosion of interest in advanced algorithms and new optimization schemes. However, there has historically been a lack of open-access realistically sized and detailed datasets-particularly for the distribution system-and simulation tools able to model these systems. This talk will present recent advances with very large-scale (>>1M nodes) distribution data sets and the use of co-simulation to tractably model large integrated transmission-distribution grids and their interactions with new controls/optimization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Helium Ion Microscopy

Nanotechnology research led to the development of various instruments to be used for imaging or fabrication. The helium ion microscope (HIM) became available in 2006 but quickly gained popularity. Its unique gas field ion source enables high-resolution imaging, nanofabrication, direct write, and the recent combination with a secondary ion mass spectrometer offers chemical imaging with ~15 nm resolution. Particularly attractive are the small interaction volume of He and Ne (the two gases offered), small beam spot size, and a moderate sputtering rate. Additionally, the HIM is an excellent imaging tool for insulating samples in soft, polymeric, and biological materials. It can be expected that helium ion microscopy will continue to have a strong influence on broad range of scientific disciplines, including chemistry, materials science, and biology.This chapter aims at providing an overview of the current status of HIM for imaging, analysis, and nanofabrication. It introduces the reader to key components of the instrument, theoretical background, and latest results in the areas of imaging, material fabrication, and chemical analysis capabilities of helium ion microscopy.

Belianinov, Alex↗

Friction Stir Cutting for Decommissioning - 16130

Safe and cost effective decommissioning of redundant nuclear plant is a primary consideration to countries and companies with aging nuclear facilities. The wider media coverage of nuclear issues and strong public feeling is ensuring decommissioning options are also considered prior to development of new nuclear facilities. A project has been undertaken to demonstrate the feasibility of applying friction stir cutting, a non-fusion, non-machining, method of separating materials for size reduction of redundant metallic nuclear plant, specifically as a flexible low cost tool for plant dismantling. The research program was designed to provide a fast and effective approach to the assessment of process feasibility in stainless steels. Friction stir cutting may begin by traversing the rotating tool into the edge of the plate, or alternatively, by piercing the plate with a suitably profiled rotating friction stir cutting tool. Plate piercing trials were conducted to determine the down-force required to pierce the plate and to identify the appropriate tool tip profile for efficient piercing. The friction stir cutting process has been successfully demonstrated in 3 mm and 6 mm thick stainless steel plate. Provided sufficient torque is available, the friction stir cutting process is suitable for robotic application. The process is suitable for submerged applications such as the removal of pond furniture. Special attention was given towards any fume generation or particulate emissions during cutting. Friction stir cutting of bare steel plate does not generate fume, results in a relatively smooth edge profile and produces minimal loose debris. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A method to evaluate hydraulic fracture using proppant detection

Accurate determination of the proppant placement and propped fracture height are important for evaluating and optimizing stimulation strategies. A technology using non-radioactive proppant and a pulsed neutron gamma energy spectra logging tool to determine the placement and height of propped fractures is proposed in this paper. Gd 2 O 3 was incorporated into ceramic proppant and a Monte Carlo method was utilized to build the logging tools and formation models. Characteristic responses of the recorded information of different logging tools to fracture widths, proppant concentrations and influencing factors were studied. The results show that Gd capture gamma rays can be used to evaluate propped fractures and it has higher sensitivity to the change of fracture width and traceable proppant content compared with the exiting non-radioactive proppant evaluation techniques and only an after-fracture measurement is needed for the new method; The changes in gas saturation and borehole size have a great impact on determining propped fractures when compensated neutron and pulsed neutron capture tool are used. Finally, a field example is presented to validate the application of the new technique.

47 OTHER INSTRUMENTATION↗

Thermal Soak Analysis of Earth Entry Vehicles

The Multi-Mission Earth Entry Vehicle project is developing an integrated tool called Multi Mission System Analysis for Planetary Entry Descent and Landing that will provide key technology solutions including mass sizing, aerodynamics, aerothermodynamics, and thermal and structural analysis for any given sample return mission. Thermal soak analysis and temperature predictions of various components including the payload container of the entry vehicle are part of the solution that this tool will offer to mission designers. The present paper focuses on the thermal soak analysis of an entry vehicle design based on the Mars Sample Return entry vehicle geometry and discusses a technical approach to develop parametric models for thermal soak analysis that will be integrated into the tool.

Agrawal, Parul↗

SU-F-BRB-07: A Plan Comparison Tool to Ensure Robustness and Deliverability in Online-Adaptive Radiotherapy

Purpose: To develop a plan comparison tool that will ensure robustness and deliverability through analysis of baseline and online-adaptive radiotherapy plans using similarity metrics. Methods: The ViewRay MRIdian treatment planning system allows export of a plan file that contains plan and delivery information. A software tool was developed to read and compare two plans, providing information and metrics to assess their similarity. In addition to performing direct comparisons (e.g. demographics, ROI volumes, number of segments, total beam-on time), the tool computes and presents histograms of derived metrics (e.g. step-and-shoot segment field sizes, segment average leaf gaps). Such metrics were investigated for their ability to predict that an online-adapted plan reasonably similar to a baseline plan where deliverability has already been established. Results: In the realm of online-adaptive planning, comparing ROI volumes offers a sanity check to verify observations found during contouring. Beyond ROI analysis, it has been found that simply editing contours and re-optimizing to adapt treatment can produce a delivery that is substantially different than the baseline plan (e.g. number of segments increased by 31%), with no changes in optimization parameters and only minor changes in anatomy. Currently the tool can quickly identify large omissions or deviations from baseline expectations. As our online-adaptive patient population increases, we will continue to develop and refine quantitative acceptance criteria for adapted plans and relate them historical delivery QA measurements. Conclusion: The plan comparison tool is in clinical use and reports a wide range of comparison metrics, illustrating key differences between two plans. This independent check is accomplished in seconds and can be performed in parallel to other tasks in the online-adaptive workflow. Current use prevents large planning or delivery errors from occurring, and ongoing refinements will lead to increased assurance of plan quality.

60 APPLIED LIFE SCIENCES↗

Deformed Materials: Towards a Theory of Materials Morphology Dynamics

This grant supported work on the response of crystals to external stress. Our primary work described how disordered structural materials break in two (statistical models of fracture in disordered materials), studied models of deformation bursts (avalanches) that mediate deformation on the microscale, and developed continuum dislocation dynamics models for plastic deformation (as when scooping ice cream bends a spoon, Fig. 9). Glass is brittle -- it breaks with almost atomically smooth fracture surfaces. Many metals are ductile -- when they break, the fracture surface is locally sheared and stretched, and it is this damage that makes them hard to break. Bone and seashells are made of brittle material, but they are strong because they are disordered -- lots of little cracks form as they are sheared and near the fracture surface, diluting the external force. We have studied materials like bone and seashells using simulations, mathematical tools, and statistical mechanics models from physics. In particular, we studied the extreme values of fracture strengths (how likely will a beam in a bridge break far below its design strength), and found that the traditional engineering tools could be improved greatly. We also studied fascinating crackling-noise precursors -- systems which formed microcracks of a broad range of sizes before they broke. Ductile metals under stress undergo irreversible plastic deformation -- the planes of atoms must slide across one another (through the motion of dislocations) to change the overall shape in response to the external force. Microscopically, the dislocations in crystals move in bursts of a broad range of sizes (termed 'avalanches' in the statistical mechanics community, whose motion is deemed 'crackling noise'). In this grant period, we resolved a longstanding mystery about the average shape of avalanches of fixed duration (using tools related to an emergent scale invariance), we developed the fundamental theory describing the shapes of avalanches and how they are affected by the edges of the microscope viewing window, we found that slow creep of dislocations can trigger an oscillating response explaining recent experiments, we explained avalanches under external voltage, and we have studied how avalanches in experiments on the microscale relate to deformation of large samples. Inside the crystals forming the metal, the dislocations arrange into mysterious cellular structures, usually ignored in theories of plasticity. Writing a natural continuum theory for dislocation dynamics, we found that it spontaneously formed walls -- much like models of traffic jams and sonic booms. These walls formed rather realistic cellular structures, which we examined in great detail -- our walls formed fractal structures with fascinating scaling properties, related to those found in turbulent fluids. We found, however, that the numerical and mathematical tools available to solve our equations were not flexible enough to incorporate materials-specific information, and our models did not show the dislocation avalanches seen experimentally. In the last year of this grant, we wrote an invited review article, explaining how plastic flow in metals shares features with other stressed materials, and how tools of statistical physics used in these other systems might be crucial for understanding plasticity.

36 MATERIALS SCIENCE↗

Flight Mechanics Analysis Tools Interoperability and Component Sharing

As multiple flight mechanics (FM) analysis tools are developed to meet the unique scientific and operational requirements of NASA missions, sharing data, transferring models and trajectory information between tools can be complicated. The NESC recently explored ways that increase interoperability of three mission analysis tools: Copernicus, General Mission Analysis Tool (GMAT), and Mission-Analysis Operations Navigation Toolkit Environment (MONTE). These tools are used to generate a variety of products throughout all phases of a mission including: maneuver planning, trajectory optimization and design, orbit determination, performance and error analysis, trade studies and sizing. Establishing a framework to share models, component data and trajectory information is an efficient way to leverage the benefits of an analysis tool without expending development costs to duplicate functionality.

Flight Mechanics Simulation↗

Universal clustering of dark matter in phase space

We have recently introduced a novel statistical measure of dark matter clustering in phase space, the particle phase-space average density (P 2 SAD). In a two-paper series, we studied the structure of P 2 SAD in the Milky Way-size Aquarius haloes, constructed a physically motivated model to describe it, and illustrated its potential as a powerful tool to predict signals sensitive to the nanostructure of dark matter haloes. In this work, we report a remarkable universality of the clustering of dark matter in phase space as measured by P 2 SAD within the subhaloes of host haloes across different environments covering a range from dwarf-size to cluster-size haloes (10 10 –10 15 M ⊙ ). Simulations show that the universality of P 2 SAD holds for more than seven orders of magnitude, over a 2D phase space, covering over three orders of magnitude in distance/velocity, with a simple functional form that can be described by our model. Invoking the universality of P 2 SAD, we can accurately predict the non-linear power spectrum of dark matter at small scales all the way down to the decoupling mass limit of cold dark matter particles. As an application, we compute the subhalo boost to the annihilation of dark matter in a wide range of host halo masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and Analysis of the Automated Object Reentry Survival Analysis Tool Parametric Study Wrapper

The NASA Orbital Debris Program Office (ODPO) Safety Group at the Johnson Space Center analyzes reentering spacecraft at the end of life. The program primarily used by ODPO in this effort is the Object Reentry Survival Analysis Tool (ORSAT). ORSAT utilizes shape primitives as well as a variety of other parameters (material, size, thickness, aerodynamic mass, orbit inclination, etc.) to simulate the reentry process and ultimately, to determine if a spacecraft could be hazardous to the population on the ground. The NASA ODPO plans to automate the ORSAT process to run multiple ORSAT input files either concurrently or consecutively. This type of automation program will provide several benefits. First, there is a need to run large parametric studies for ORSAT analysts to gain a greater understanding of reentering object’s sensitivity to certain input variables. Secondly, a database of pre-run ORSAT cases will be used to develop a survivability model, which could be made available to spacecraft developers as a design for demise (D4D) tool. The recently completed Automated Object Reentry Survival Analysis Tool (AutoORSAT) Wrapper is currently being used to build a survivability database, the first step in developing a survivability model. Already, the data that AutoORSAT has produced provides a greater understanding of the sensitivity of variables such as the initial temperature of the spacecraft, spacecraft breakup altitude, and the aerodynamic mass of spacecraft.

Smith, Andrew N.↗

Simulation of Particulate Transport for Delivery of Solid Amendments into the Subsurface: FY24 Status Report

For particulate-based amendments to be viable for field-scale remediation at the Hanford Site (e.g., 200 DV-1 Operable Unit), particles need to be delivered a sufficient radial distance from an injection well and retained at concentrations high enough for effective treatment. An accurate description of the particle radius of influence (ROI) is critical for developing an overall remediation strategy. However, field-scale particle simulations are currently limited due to insufficient simulation capabilities and a lack of experimental data to validate and parameterize particle transport models. To help build toward field-scale deployment, this fiscal year (FY) we have (1) developed a pre screening tool to estimate particle transport, (2) implemented particle transport models within PFLOTRAN, and (3) conducted preliminary estimations of particle ROI. While field-scale numerical simulations will ultimately be necessary before remedy design and field implementation, we have developed a pre-screening tool that offers valuable estimations of expected particle injectability and ROI in a 1-D system. The advantage of the tool is that it does not require extensive laboratory experiments and instead makes predictions based solely on routine laboratory measurements. This tool can assist in down-selection and decision-making by identifying which particle amendment systems are worth pursuing in future laboratory experiments, such as 1-D column tests and beyond. With any system, scaling up from the lab to the field presents challenges. Currently, there is no field data available for model calibration or validation. However, the theoretical particle models being developed herein are the best tools available to guide progress toward field deployment. To help bridge this gap and verify model predictions, larger-scale lab experiments are being proposed. To advance simulation capabilities, six particle transport models are being integrated into the reactive transport simulator PFLOTRAN. These include colloid filtration theory (CFT) and five additional particle transport models (M1-M5). Each model, from M1 to M5, progressively incorporates additional particle transport and retention processes. Ultimately, the simplest model capable of accurately describing 1-D column data will be selected and parameterized. During FY24, the CFT and M1 model have been fully implemented within PFLOTRAN. Using an existing 1 D column experiment, the two currently implemented particle transport models (CFT and M1), and associated parameters, were fit to this experiment. While simpler model formulations are helpful for estimations, these formulations could not fully describe particle transport and retention behavior in the previous 1-D column experiment. Thus, additional complexities will need to be considered, which will be accounted for in the M2-M5 model formulations. Additionally, because a viscous, shear thinning fluid was required to keep particles in suspension, considerations for flow will also need to also be accounted for. Therefore, a new immiscible two-phase flow mode is currently being implemented in PFLOTRAN. With some modifications, this new flow module could also support simulation of non-Newtonian liquid amendments, foams, and emulsions. We also estimated the expected ROI of solid amendments using 1-D simulations. The average predicted ROI was approximately 15 ft for micron-sized zero valent iron (mZVI) suspended in xanthan gum (XG). Using the pre screening tool and ROI estimates, additional amendment-delivery laboratory characterization and experiments are proposed. The results from additional experiments can be used to validate and parametrize particulate transport model formulations, which will ultimately provide predictive capabilities for field amendment-delivery systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-253: Development of a GDPM Monte Carlo Based Quality Assurance Tool for Cyberknife

Purpose: To develop a 3D quality assurance (QA) tool for Cyberknife plans using a GPU-based Monte Carlo dose calculation package, gDPM. The developed QA tool will be used as a secondary check for Cyberknife treatment planning software (TPS) reported dose distributions. Methods: Phase space files of the 5, 7.5, 10, 15, and 60 mm iris cones were downloaded from IAEA phase-space database. From the 60mm iris cone phase space file, we were able to generate raw phase space files for all other cones using a particle rejection method. The particles in the raw phase space files were binned with respect to the radial position and energy for commissioning. During the commissioning process, gDPM calculated percent depth dose and off-center ratios which were compared to those measured in the Blue Phantom. The off-axis data was measured with an SAD setup at depths of 15, 50, 100, 200, and 300 mm. At the commissioning stage, an optimization problem was solved to adjust the binned particles weights to minimize the difference between the calculated and measured ones. Commissioning validations will be performed by measuring point dose data of patient specific plans delivered to water phantoms. With commissioned phase space files, 3D patient-specific dose distributions will be calculated and compared against TPS reported dose. Results: Beyond the initial buildup region, the root mean square difference between the calculated and measured percent depth dose differences was less than 0.5%. The full-width half-max data from the off-axis ratio calculations was found to be within 0.1 mm of the measured data. Conclusion: Our current work showed excellent agreement between the gDPM calculated dose and the measured data for all cone sizes and types for the Cyberknife system. Implementation of a fast and accurate QA tool for patient specific plans will be feasible with this tool.

60 APPLIED LIFE SCIENCES↗

Building a full-size glider

The building and flying of a glider is possible for anyone who can use a few basic tools. This report presents some plans and techniques for building your own glider.

GLIDERS - DESIGN & CONSTRUCTION↗

Adjustable virtual pore-size filter for automated sample preparation using acoustic radiation force

We present a rapid and robust size-based separation method for high throughput microfluidic devices using acoustic radiation force. We developed a finite element modeling tool to predict the two-dimensional acoustic radiation force field perpendicular to the flow direction in microfluidic devices. Here we compare the results from this model with experimental parametric studies including variations of the PZT driving frequencies and voltages as well as various particle sizes and compressidensities. These experimental parametric studies also provide insight into the development of an adjustable 'virtual' pore-size filter as well as optimal operating conditions for various microparticle sizes. We demonstrated the separation of Saccharomyces cerevisiae and MS2 bacteriophage using acoustic focusing. The acoustic radiation force did not affect the MS2 viruses, and their concentration profile remained unchanged. With optimized design of our microfluidic flow system we were able to achieve yields of > 90% for the MS2 with > 80% of the S. cerevisiae being removed in this continuous-flow sample preparation device.

59 BASIC BIOLOGICAL SCIENCES↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗

CONSTRAINTS FROM ASYMMETRIC HEATING: INVESTIGATING THE EPSILON AURIGAE DISK

Epsilon Aurigae is a long-period eclipsing binary that likely contains an F0Ia star and a circumstellar disk enshrouding a hidden companion, assumed to be a main-sequence B star. High uncertainty in its parallax has kept the evolutionary status of the system in question and, hence, the true nature of each component. This unknown, as well as the absence of solid state spectral features in the infrared, requires an investigation of a wide parameter space by means of both analytic and Monte Carlo radiative transfer (MCRT) methods. The first MCRT models of epsilon Aurigae that include all three system components are presented here. We seek additional system parameter constraints by melding analytic approximations with MCRT outputs (e.g., dust temperatures) on a first-order level. The MCRT models investigate the effects of various parameters on the disk-edge temperatures; these include two distances, three particle size distributions, three compositions, and two disk masses, resulting in 36 independent models. Specifically, the MCRT temperatures permit analytic calculations of effective heating and cooling curves along the disk edge. These are used to calculate representative observed fluxes and corresponding temperatures. This novel application of thermal properties provides the basis for utilization of other binary systems containing disks. We find degeneracies in the model fits for the various parameter sets. However, the results show a preference for a carbon disk with particle size distributions ≥10 μm. Additionally, a linear correlation between the MCRT noon and basal temperatures serves as a tool for effectively eliminating portions of the parameter space.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation Mapping at JET and ITER using advanced computational acceleration techniques and tools - Paper 63

The Applied Radiation Physics group at the Culham Centre for Fusion Energy (CCFE) have developed and applied state-of-the-art radiation mapping methods and tools to enable complex shielding calculations in fusion devices during plasma operations, and associated maintenance in the device and surrounding areas. Here, we present the description and application of those tools to produce radiation maps both to support the JET safety case (the EU experimental tokamak device based at Culham) and the planned DT campaign in the next few years; and the ITER device. Radiation mapping of fusion facilities are essential for assessing radiation hardness of electronics during operations, and to define safe working dose limits to staff during routine maintenance. At CCFE the Monte Carlo radiation transport code MCNP6 is one of the codes used to perform radiation transport calculations. Due to the size and complexity of the JET and ITER devices, and their surrounding buildings, a suite of tools have been created at CCFE to reduce the computational requirements of the calculations. This paper describes three of these tools, which have been developed and applied to nuclear and radiological field mapping in fusion devices. The results presented in this paper highlight the application of three methods that have been used to improve the computational efficiency and capabilities for radiation mapping in fusion devices such as JET and ITER. These methods are Global Variance Reduction, the Surface Source Mesh routine and the Smeared Source routine. This paper demonstrates the three techniques used in combination, enabling a very computationally challenging fusion problem to become tractable (with acceptable computing effort), also enabling improved capability to allow the mapping of radiations fields during transport operations for activated materials. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Adjustable Headband for Earphones

New handband designed for comfort and convenience. New band consists of pair of steel head-clamping spring strips joined by tensioning screw. Cushioned side support mounted on end of one strip, and cushioned earphone and microphone mounted on end of second strip. Band reversible. Easily adjusted for head size and readily readjusted for greater comfort without removing.

Toole, P. C.↗