Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spatial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

WHY IS NON-THERMAL LINE BROADENING OF SPECTRAL LINES IN THE LOWER TRANSITION REGION OF THE SUN INDEPENDENT OF SPATIAL RESOLUTION?

Spectral observations of the solar transition region (TR) and corona show broadening of spectral lines beyond what is expected from thermal and instrumental broadening. The remaining non-thermal broadening is significant (5–30 km s{sup −1}) and correlated with intensity. Here we study spectra of the TR Si iv 1403 Å line obtained at high resolution with the Interface Region Imaging Spectrograph (IRIS). We find that the large improvement in spatial resolution (0.″33) of IRIS compared to previous spectrographs (2″) does not resolve the non-thermal line broadening which, in most regions, remains at pre-IRIS levels of about 20 km s{sup −1}. This invariance to spatial resolution indicates that the processes behind the broadening occur along the line-of-sight (LOS) and/or on spatial scales (perpendicular to the LOS) smaller than 250 km. Both effects appear to play a role. Comparison with IRIS chromospheric observations shows that, in regions where the LOS is more parallel to the field, magneto-acoustic shocks driven from below impact the TR and can lead to significant non-thermal line broadening. This scenario is supported by MHD simulations. While these do not show enough non-thermal line broadening, they do reproduce the long-known puzzling correlation between non-thermal line broadening and intensity. This correlation is caused by the shocks, but only if non-equilibrium ionization is taken into account. In regions where the LOS is more perpendicular to the field, the prevalence of small-scale twist is likely to play a significant role in explaining the invariance and correlation with intensity. (letters)

79 ASTRONOMY AND ASTROPHYSICS↗

Development of an Experimental Approach to Achieve Spatially Resolved Plant Root-Associated Metaproteomics Using an Agar-Plate System

Plant–microbe interactions in the rhizosphere play a vital role in plant health and productivity. The composition and function of root-associated microbiomes is strongly influenced by their surrounding environment, which is often customized by their host. How microbiomes change with respect to space and time across plant roots remains poorly understood, and methodologies that facilitate spatiotemporal metaproteomic studies of root-associated microbiomes are yet to be realized. Here, we developed a method that provides spatially resolved metaproteome measurements along plant roots embedded in agar-plate culture systems, which have long been used to study plants. Spatially defined agar “plugs” of interest were excised and subsequently processed using a novel peptide extraction method prior to metaproteomics, which was used to infer both microbial community composition and function. As a proof-of-principle, a previously studied 10-member community constructed from a Populus root system was grown in an agar plate with a 3-week-old Populus trichocarpa plant. Metaproteomics was performed across two time points (24 and 48 h) for three distinct locations (root base, root tip, and a region distant from the root). The spatial resolution of these measurements provides evidence that microbiome composition and expression changes across the plant root interface. Interrogation of the individual microbial proteomes revealed functional profiles related to their behavioral associations with the plant root, in which chemotaxis and augmented metabolism likely supported predominance of the most abundant member. This study demonstrated a novel peptide extraction method for studying plant agar-plate culture systems, which was previously unsuitable for (meta)proteomic measurements.

59 BASIC BIOLOGICAL SCIENCES↗

Spatial distribution of radiation damage to crystalline proteins at 25–300 K

Dose-dependent atomic B factors are used to determine the average spatial distribution of radiation damage to crystalline thaumatin and urease. The spatial distribution of radiation damage (assayed by increases in atomic B factors) to thaumatin and urease crystals at temperatures ranging from 25 to 300 K is reported. The nature of the damage changes dramatically at approximately 180 K. Above this temperature the role of solvent diffusion is apparent in thaumatin crystals, as solvent-exposed turns and loops are especially sensitive. In urease, a flap covering the active site is the most sensitive part of the molecule and nearby loops show enhanced sensitivity. Below 180 K sensitivity is correlated with poor local packing, especially in thaumatin. At all temperatures, the component of the damage that is spatially uniform within the unit cell accounts for more than half of the total increase in the atomic B factors and correlates with changes in mosaicity. This component may arise from lattice-level, rather than local, disorder. The effects of primary structure on radiation sensitivity are small compared with those of tertiary structure, local packing, solvent accessibility and crystal contacts.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determining the Spatial Profiles of Electron and Hole Concentration, Radiative and Non-Radiative Recombination Rate Near a Dislocation Defect by Combining Raman and Photoluminescence Imaging

For commonly utilized photoluminescence (PL) imaging, the spatial resolution is dictated by the carrier diffusion length rather than by that dictated by the optical system, such as diffraction limit. Here, we show that Raman imaging of the LO phonon-plasmon (LOPP) coupled mode can be used to recover the intrinsic spatial resolution of the optical system, as demonstrated by Raman imaging of defects in GaAs, achieving a 10-fold improvement in resolution. Furthermore, by combining Raman and PL imaging, we can independently determine the spatial profiles of the electron and hole density, radiative and non-radiative recombination rate near a dislocation defect, which has not been possible using other techniques.

14 SOLAR ENERGY↗

Cumulative Spatial Impact Layers: A Novel Multivariate Spatio-Temporal Analytical Summarization Tool

Scientific inquiry often requires analysis of multiple spatio-temporal datasets, ranging in type and size, using complex multi-step processes demanding an understanding of GIS theory and software. Cumulative Spatial Impact Layers (CSIL) is a GIS-based tool that summarizes spatio-temporal datasets based on overlapping features and attributes. Leveraging a recursive quadtree method, and applying multiple additive frameworks, the CSIL tool allows users to analyze raster and vector datasets by calculating data, record, or attribute density. Providing an efficient and robust method for summarizing disparate, multi-format, multi-source geospatial data, CSIL addresses the need for a new integration approach and resulting geospatial product. The built-in flexibility of the CSIL tool allows users to answer a range of spatially-driven questions. Example applications are provided in this paper to illustrate the versatility and variety of uses for this CSIL tool and method. Use cases include addressing regulatory decision-making needs, economic modeling, and resource management. Performance reviews for each use case are also presented, demonstrating how CSILs provides a more efficient and robust approach to assess a range of multivariate spatial data for a variety of uses.

58 GEOSCIENCES↗

SU-E-T-415: An Ionization Chamber Array with High Spatial Resolution for External Beam Radiotherapy

Purpose: To characterize an ionization chamber array technology with high spatial resolution and high charge collection efficiency for external beam radiotherapy. Methods: The prototype under test is a linear array of air vented ionization chambers developed by IBA Dosimetry, consisting of 80 pixels with 3.5mm spatial resolution and 4mm{sup 3} sensitive volume. The detector was characterized in a plastic phantom with {sup 60} Co radiation and MV X-rays from an ELEKTA Agility LINAC (with flattened and unflattened beam qualities). Bias voltage was varied in order to evaluate charge collection efficiency. A commercial array of ionization chambers (MatriXX Evolution, IBA Dosimetry) and an amorphous silicon flat panel in direct conversion configuration were used as references. Results: Repeatability (0.4%) and stability under continuous gamma irradiation (0.3%) are very good, in spite of low active volume and sensitivity (∼200pC/Gy). Charge collection efficiency is higher than 99% already at 150V with ∼2mGy dose per pulse, leading to a ±1.1% sensitivity change with dose per pulse in the range 0.09-2mGy (covering all flattened and unflattened applications). Measured dose profiles are in agreement with MatriXX for fields larger than 2×2cm{sup 2}, in which case the linear array offers a much better characterization of the penumbra region. Down to 1×1cm{sup 2}, measured profiles are in very good agreement with the flat panel. Conclusion: The array represents a valuable tool for the characterization of treatment fields in which high spatial resolution is required, together with the dosimetric performance of air vented ionization chambers. Such a technology would be particularly valuable in association with advanced treatment modalities such as rotational radiotherapy, stereotactic treatments (even with unflattened beam qualities) and proton therapy, due to the insensitivity of the chambers on dose per pulse. In the future, a two dimensional prototype based on this technology will be developed and tested. This research project has been supported by a Marie Curie Early Initial Training Network Fellowship of the European Community's Seventh Framework Programme under contract number (PITN-GA-2011-289198-.

07 ISOTOPE AND RADIATION SOURCES↗

CT imaging during microwave ablation: Analysis of spatial and temporal tissue contraction

Purpose: To analyze the spatial distribution and temporal development of liver tissue contraction during high-temperature ablation by using intraprocedural computed tomography (CT) imaging. Methods: A total of 46 aluminum fiducial markers were positioned in a 60 × 45 mm grid, in a single plane, around a microwave ablation antenna in each of six ex vivo bovine liver samples. Ablations were performed for 10 min at 100 W. CT data of the liver sample were acquired every 30 s during ablation. Fiducial motion between acquisitions was tracked in postprocessing and used to calculate measures of tissue contraction and contraction rates. The spatial distribution and temporal evolution of contraction were analyzed. Results: Fiducial displacement indicated that the zone measured postablation was 8.2 ± 1.8 mm (∼20%) smaller in the radial direction and 7.1 ± 1.0 mm (∼10%) shorter in the longitudinal direction than the preablation tissue dimension. Therefore, the total ablation volume was reduced from its preablation value by approximately 45%. Very little longitudinal contraction was noted in the distal portion of the ablation zone. Central tissues contracted more than 60%, which was near an estimated limit of ∼70% based on initial water content. More peripheral tissues contracted only 15% in any direction. Contraction rates peaked during the first 60 s of heating with a roughly exponential decay over time. Conclusions: Ablation zones measured posttreatment are significantly smaller than the pretreatment tissue dimensions. Tissue contraction is spatially dependent, with the greatest effect occurring in the central ablation zone. Contraction rate peaks early and decays over time.

60 APPLIED LIFE SCIENCES↗

Evolution of spatial resolution in breast CT at UC Davis

Purpose: Dedicated breast computed tomography (bCT) technology for the purpose of breast cancer screening has been a focus of research at UC Davis since the late 1990s. Previous studies have shown that improvement in spatial resolution characteristics of this modality correlates with greater microcalcification detection, a factor considered a potential limitation of bCT. The aim of this study is to improve spatial resolution as characterized by the modulation transfer function (MTF) via changes in the scanner hardware components and operational schema. Methods: Four prototypes of pendant-geometry, cone-beam breast CT scanners were designed and developed spanning three generations of design evolution. To improve the system MTF in each bCT generation, modifications were made to the imaging components (x-ray tube and flat-panel detector), system geometry (source-to-isocenter and detector distance), and image acquisition parameters (technique factors, number of projections, system synchronization scheme, and gantry rotational speed). Results: Characterization of different generations of bCT systems shows these modifications resulted in a 188% improvement of the limiting MTF properties from the first to second generation and an additional 110% from the second to third. The intrinsic resolution degradation in the azimuthal direction observed in the first generation was corrected by changing the acquisition from continuous to pulsed x-ray acquisition. Utilizing a high resolution detector in the third generation, along with modifications made in system geometry and scan protocol, resulted in a 125% improvement in limiting resolution. An additional 39% improvement was obtained by changing the detector binning mode from 2 × 2 to 1 × 1. Conclusions: These results underscore the advancement in spatial resolution characteristics of breast CT technology. The combined use of a pulsed x-ray system, higher resolution flat-panel detector and changing the scanner geometry and image acquisition logic resulted in a significant fourfold improvement in MTF.

60 APPLIED LIFE SCIENCES↗

WE-EF-303-04: An Advanced Image Processing Method to Improve the Spatial Resolution of Proton Radiographies

Purpose: We present an optimization method to improve the spatial resolution and the water equivalent thickness accuracy of proton radiographies. Methods: The method is designed for imaging systems measuring only the residual range of protons without relying on tracker detectors to determine the beam trajectory before and after the target. Specifically, the method was used for an imaging set-up consisting of a stack of 61 parallel-plate ionization chambers (PPIC) working as a range telescope. The method uses a decomposition approach of the residual range signal measured by the PPIC and constructs subimages with small size pixels geometrically rearranged and appropriately averaged to be merged into a final single radiography. The method was tested using Monte Carlo simulated and experimental proton radiographies of a PMMA step phantom and an anthropomorphic head phantom. Results: For the step phantom, the effective spatial resolution was found to be 4 and 3 times higher than the nominal resolution for the simulated and experimental radiographies, respectively. For the head phantom, a gamma index was calculated to quantify the conformity of the simulated proton radiographies with a digitally reconstructed X-ray radiography convolved with a Gaussian kernel equal to the proton beam spot-size. For DTA=2.5 mm and RD=2.5%, the passing ratio was 100%/85% for the optimized/non-optimized case, respectively. An extension of the method allows reducing the dose given to the patient during radiography acquisition. We show that despite a dose reduction of 25 times (leading to a dose of 0.016 mGy for the current imaging set-up), the image quality of the optimized radiographies remains fairly unaffected for both the simulated and experimental results. Conclusion: The optimization method leads to a significant increase of the spatial resolution allowing recovering image details that are unresolved in non-optimized radiographies. These results represent a major step towards clinical application of proton radiography.

60 APPLIED LIFE SCIENCES↗

Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications

Purpose: High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. Methods: A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixel pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. Results: At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Conclusions: Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-189: A Method to Improve the Spatial Resolution of Prompt Gamma Based Compton Imaging for Proton Range Verification

Purpose: To test two new techniques, the distance-of-closest approach (DCA) and Compton line (CL) filters, developed as a means of improving the spatial resolution of Compton camera (CC) imaging. Methods: Gammas emitted from {sup 22}Na, {sup 137}Cs, and {sup 60}Co point sources were measured with a prototype 3-stage CC. The energy deposited and position of each interaction in each stage were recorded and used to calculate a “cone-of-origin” for each gamma that scattered twice in the CC. A DCA filter was developed which finds the shortest distance from the gamma’s cone-of-origin surface to the location of the gamma source. The DCA filter was applied to the data to determine the initial energy of the gamma and to remove “bad” interactions that only contribute noise to the image. Additionally, a CL filter, which removes gamma events that do not follow the theoretical predictions of the Compton scatter equation, was used to further remove “bad” interactions from the measured data. Then images were reconstructed with raw, unfiltered data, DCA filtered data, and DCA+CL filtered data and the achievable image resolution of each dataset was compared. Results: Spatial resolutions of ∼2 mm, and better than 2 mm, were achievable with the DCA and DCA+CL filtered data, respectively, compared to > 5 mm for the raw, unfiltered data. Conclusion: In many special cases in medical imaging where information about the source position may be known, such as proton radiotherapy range verification, the application of the DCA and CL filters can result in considerable improvements in the achievable spatial resolutions of Compton imaging.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-10: New Generation of High Frame-Rate and High Spatial-Resolution EPID QA System for Full-Body MLC-Based Robotic Radiosurgery

Purpose: To systematically investigate an ultra-high spatial-resolution amorphous silicon flat-panel electronic portal imaging device (EPID) for MLC-based full-body robotic radiosurgery geometric and dosimetric quality assurance (QA). Methods: The high frame-rate and ultra-high spatial resolution EPID is an outstanding detector for measuring profiles, MLC-shaped radiosurgery field aperture verification, and small field dosimetry. A Monte Carlo based technique with a robotic linac specific response and calibration is developed to convert a raw EPID-measured image of a radiosurgery field into water-based dose distribution. The technique is applied to measure output factors and profiles for 6MV MLC-defined radiosurgery fields with various sizes ranging from 7.6mm×7.7mm to 100mm×100.1mm and the results are compared with the radiosurgery diode scan measurements in water tank. The EPID measured field sizes and the penumbra regions are analyzed to evaluate the MLC positioning accuracy. Results: For all MLC fields, the EPID measured output factors of MLC-shaped fields are in good agreement with the diode measurements. The mean output difference between the EPID and diode measurement is 0.05±0.87%. The max difference is −1.33% for 7.6mm×7.7mm field. The MLC field size derived from the EPID measurements are in good agreement comparing to the diode scan result. For crossline field sizes, the mean difference is −0.17mm±0.14mm with a maximum of −0.35mm for the 30.8mm×30.8mm field. For inline field sizes, the mean difference is +0.08mm±0.18mm with a maximum of +0.45mm for the 100mm×100.1mm field. The high resolution EPID is able to measure the whole radiation field, without the need to align the detector center perfectly at field center as diode or ion chamber measurement. The setup time is greatly reduced so that the whole process is possible for machine and patient-specific QA. Conclusion: The high spatial-resolution EPID is proved to be an accurate and efficient tool for QA of MLC-equipped robotic radiosurgery system.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-09: Experimental Assessment of Noise and Spatial Resolution in Virtual Non-Contrast Dual-Energy CT Images Across Multiple Patient Sizes and CT Systems

Purpose: To investigate the noise and spatial resolution properties of virtual non-contrast (VNC) dual-energy CT images compared to true non-contrast (TNC) images across multiple patient sizes and CT systems. Methods: Torso-shaped water phantoms with lateral widths of 25, 30, 35, 40 and 45 cm and a high resolution bar pattern phantom (Catphan CTP528) were scanned using 2nd and 3rd generation dual-source CT systems (Scanner A: Somatom Definition Flash, Scanner B: Somatom Force, Siemens Healthcare) in dual-energy scan mode with the same radiation dose for a given phantom size. Tube potentials of 80/Sn140 and 100/Sn140 on Scanner A and 80/Sn150, 90/Sn150 and 100/Sn150 on Scanner B were evaluated to examine the impact of spectral separation. Images were reconstructed using a medium sharp quantitative kernel (Qr40), 1.0-mm thickness, 1.0-mm interval and 20 cm field of view. Mixed images served as TNC images. VNC images were created using commercial software (Virtual Unenhanced, Syngo VIA Version VA30, Siemens Healthcare). The noise power spectrum (NPS), area under the NPS, peak frequency of the NPS and image noise were measured for every phantom size and tube potential combination in TNC and VNC images. Results were compared within and between CT systems. Results: Minimal shift in NPS peak frequencies was observed in VNC images compared to TNC for NPS having pronounced peaks. Image noise and area under the NPS were higher in VNC images compared to TNC images across all tube potentials and for scanner A compared to scanner B. Limiting spatial resolution was deemed to be identical between VNC and TNC images. Conclusion: Quantitative assessment of image quality in VNC images demonstrated higher noise but equivalent spatial resolution compared to TNC images. Decreased noise was observed in the 3rd generation dual-source CT system for tube potential pairs having greater spectral separation. Dr. McCollough receives research support from Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Experimental study of the spatial distributions of relativistic electron beams reflected and refracted by a thin foil

Photographs of cross sections of an electron beam scattered from thin foils have been obtained on a dosimetric film. The procession of images makes it possible to obtain the spatial distribution of particles both reflected from a foil and passed through it. The spatial distribution of electrons incident on aluminum, copper, and lead foils, as well as on bimetallic foils composed of aluminum and lead layers and of aluminum and copper layers, has been measured. The effect of the material and thickness of the foil, as well as of the angle between the initial beam trajectory and the target plane, on the spatial distribution of electrons has been studied. The effect of the sequence of the metal layers in bimetallic foils on the distribution of beams has been analyzed. A 7.4-MeV microtron has been used as a source of electrons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MOLNs: A Cloud Platform for Interactive, Reproducible, and Scalable Spatial Stochastic Computational Experiments in Systems Biology Using PyURDME

Computational experiments using spatial stochastic simulations have led to important new biological insights, but they require specialized tools and a complex software stack, as well as large and scalable compute and data analysis resources due to the large computational cost associated with Monte Carlo computational workflows. The complexity of setting up and managing a large-scale distributed computation environment to support productive and reproducible modeling can be prohibitive for practitioners in systems biology. This results in a barrier to the adoption of spatial stochastic simulation tools, effectively limiting the type of biological questions addressed by quantitative modeling. In this paper, we present PyURDME, a new, user-friendly spatial modeling and simulation package, and MOLNs, a cloud computing appliance for distributed simulation of stochastic reaction-diffusion models. In conclusion, MOLNs is based on IPython and provides an interactive programming platform for development of sharable and reproducible distributed parallel computational experiments.

97 MATHEMATICS AND COMPUTING↗

Impact of Porous Transport Layer In-Plane Conduction on Spatially Resolved Current and EIS Measurements in a Proton Exchange Membrane Water Electrolyzer

An XY segmented cell was developed for low temperature PEM water electrolysis (PEMWE). The system can assess the local performance by enabling in situ measurements of spatial currents and impedances. In this work, we show through experiments, as well as through modelling work, that the porous transport layer (PTL) must be segmented to eliminate crosstalk. Accurate measurements are only possible when crosstalk is fully eliminated. The XY segmented cell is applied to a case study characterizing the impact of a PTL platinum coating void on spatial performance. The localized performance impact of the coating void is found to be orientation specific: coating voids facing the catalyst layer reduce performance significantly more than coating voids facing the flow field. The results suggest that the tolerances for PTL coating uniformity can be lower at the side facing the flow field. The work showcases the feasibility of the XY segmented cell for impact assessment studies. The presented XY segmented cell enables the characterization of spatial phenomena in PEMWE devices and is envisioned to support modeling efforts and the investigation of manufacturing related tolerances for mass produced PEMWE devices.

08 HYDROGEN↗

Tracing the impacts of Mount Pinatubo eruption on regional climate using spatially-varying changepoint detection

Significant events, such as volcanic eruptions, can have global and long-lasting impacts on climate. These global impacts, however, are not uniform across space and time. Understanding how the Mt. Pinatubo eruption affects global and regional climate is of great interest for predicting the impact on climate due to similar events as well as understanding the possible effect of the stratospheric aerosol injections proposed to combat climate change. While many studies illustrated the impact of the Pinatubo eruption on a global scale, studies at a fine regional scale are scarce. Here, we propose a Bayesian spatially-varying changepoint detection and estimation method to trace the impact of Mt. Pinatubo eruption on regional climate. Our approach takes into account the diffusing nature and spatial correlation of the climate changes attributed to the volcanic eruption. We illustrate our method and demonstrate its advantages over an existing changepoint detection method through simulations. Finally, we apply our method to monthly stratospheric aerosol optical depth and surface temperature data from 1985 to 1995 to detect and estimate changepoints following the 1991 Mt. Pinatubo eruption. Our results quantitatively characterize the spatial pattern of the eruption’s impact on regional climate, complementing the previous studies on the global impact of the Pinatubo eruption.

Aerosol optical depth↗

Data for: Spatial access and resource limitations control carbon mineralization in soils

This dataset contains data and code used for the paper "Spatial access and resource limitations control carbon mineralization in soils", https://doi.org/10.1016/j.soilbio.2021.108427. Core-scale soil carbon fluxes are ultimately regulated by pore-scale dynamics of substrate availability and microbial access. These are constrained by physicochemical and biochemical phenomena (e.g. spatial access and hydrologic connectivity, physical occlusion, adsorption-desorption with mineral surfaces, nutrient and resource limitations). We conducted an experiment to determine how spatial access and resource limitations influence core-scale water-soluble soil organic matter (SOM) mineralization, and how these are regulated by antecedent moisture conditions. Intact soil cores were incubated at field-moist vs. drought conditions, after which they were saturated from above (to simulate precipitation) or below (to simulate groundwater recharge). Soluble carbon (acetate) and nitrogen (nitrate) forms were added to some cores during the rewetting process to alleviate potential nutrient limitations. Soil respiration was measured during the incubation, after which pore water was extracted from the saturated soils and analyzed for water soluble organic carbon concentrations and characterization. Our results showed that carbon (C) amendments increased the cumulative carbon dioxide (CO2) evolved from the soil cores, suggesting that the soils were C-limited. Drought and rewetting increased soil respiration, and there was a greater abundance of complex aromatic molecules in pore waters sampled from these soils. This newly available substrate appeared to alleviate nutrient limitations on respiration, because there were no further respiration increases with subsequent C and N amendments. We had hypothesized that respiration would be influenced by wetting direction, as simulated precipitation would mobilize C from the surface. However, as a main effect, this response was seen only in the C-amended soils, indicating that surface-C may not have been bioavailable. At the pore scale (pore water samples), drought and the C, N amendments caused a net loss of identified molecules when the soils were rewet from below, whereas wetting from above caused a net increase in identified molecules, suggesting that fresh inputs stimulated the C-and N-limited microbial populations present deeper in the soil profile. Our experiment highlights the complex and interactive role of antecedent moisture conditions, wetting direction, and resource limitations in driving core-scale C fluxes.This dataset contains a compressed (.zip) archive of the data and R scripts used for this manuscript. The dataset includes files in .csv format, which can be accessed and processed using MS Excel or R. This archive can also be accessed on GitHub at https://github.com/kaizadp/TES_spatial_access_2021 (DOI: 10.5281/zenodo.5522938).

54 ENVIRONMENTAL SCIENCES↗