Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software software requirements quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Level-3 Calorimetric Resolution available for the Level-1 and Level-2 CDF Triggers

As the Tevatron luminosity increases sophisticated selections are required to be efficient in selecting rare events among a very huge background. To cope with this problem, CDF has pushed the offline calorimeter algorithm reconstruction resolution up to Level 2 and, when possible, even up to Level 1, increasing efficiency and, at the same time, keeping under control the rates. The CDF Run II Level 2 calorimeter trigger is implemented in hardware and is based on a simple algorithm that was used in Run I. This system has worked well for Run II at low luminosity. As the Tevatron instantaneous luminosity increases, the limitation due to this simple algorithm starts to become clear: some of the most important jet and MET (Missing ET) related triggers have large growth terms in cross section at higher luminosity. In this paper, we present an upgrade of the Level 2 Calorimeter system which makes the calorimeter trigger tower information available directly to a CPU allowing more sophisticated algorithms to be implemented in software. Both Level 2 jets and MET can be made nearly equivalent to offline quality, thus significantly improving the performance and flexibility of the jet and MET related triggers. However in order to fully take advantage of the new L2 triggering capabilities having at Level 1 the same L2 MET resolution is necessary. The new Level-1 MET resolution is calculated by dedicated hardware. This paper describes the design, the hardware and software implementation and the performance of the upgraded calorimeter trigger system both at Level 2 and Level 1.

43 PARTICLE ACCELERATORS↗

A Statistical Method for Assessing Peptide Identification Confidence in Accurate Mass and Time Tag Proteomics

High-throughput proteomics is rapidly evolving to require high mass measurement accuracy for a variety of different applications. Increased mass measurement accuracy in bottom-up proteomics specifically allows for an improved ability to distinguish and characterize detected MS features, which may in turn be identified by, e.g., matching to entries in a database for both precursor and fragmentation mass identification methods. Many tools exist with which to score the identification of peptides from LC-MS/MS measurements or to assess matches to an accurate mass and time (AMT) tag database, but these two calculations remain distinctly unrelated. Here we present a statistical method, Statistical Tools for AMT tag Confidence (STAC), which extends our previous work incorporating prior probabilities of correct sequence identification from LC-MS/MS, as well as the quality with which LC-MS features match AMT tags, to evaluate peptide identification confidence. Compared to existing tools, we are able to obtain significantly more high-confidence peptide identifications at a given false discovery rate and additionally assign confidence estimates to individual peptide identifications. Freely available software implementations of STAC are available in both command line and as a Windows graphical application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Annular Flow Simulation Supported by Iterative In-Memory Mesh Adaptation

Various flow regimes exist in a boiling water reactor (BWR) as the steam quality increases in the uprising coolant flow, from bubbly flow, slug/churn flow, to annular flow. The annular flow is characterized by the presence of a fast-moving gas core and the surrounding liquid film flowing on the conduit wall. Additionally, entrained droplets can be observed in the gas core with ingested bubbles in the liquid film. The dynamics occurring on the wavy interface between the liquid film and gas core plays a crucial role in affecting the heat transfer rate and pressure drop within the BWR core. However, a fundamental understanding of annular flow is still lacking, partly due to the difficulty in obtaining detailed local data in annular flow experiments. In the current study, a novel simulation framework is developed for the annular flow by coupling a computational fluid dynamics flow solver with state-of-the-art meshing software. The gas-liquid interface is tracked with the level set method. Based on the computed flow solutions, the computational mesh is dynamically adapted in memory to meet the local mesh resolution requirement. This iterative simulation-adaptation framework can ensure the fine mesh resolution across the interface, which not only helps mitigate the mass conservation degradation known to level set methods but also improves the representation of dramatic interface topological changes such as wave breaking and droplet entrainment. The present investigation will shed light onto the complex interfacial processes involved in annular flow and generate much needed simulation data for annular flow modeling.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Contaminated Soil Volume Estimation at the Maywood Site - 12292

As part of the ongoing remediation process at the Maywood Formerly Utilized Sites Remedial Action Program properties, Argonne National Laboratory assisted the U.S. Army Corps of Engineers (USACE) New York District in revising contaminated soil volume estimates for the remaining areas of the Stepan/Sears properties that require soil remediation. As part of the volume estimation process, an initial conceptual site model (ICSM) was prepared for the entire site that captured existing information (with the exception of soil sampling results) pertinent to the possible location of surface and subsurface contamination above cleanup requirements. This ICSM was based on historical anecdotal information, aerial photographs, and the logs from several hundred soil cores that identified the depth of fill material and the depth to bedrock under the site. Specialized geostatistical software developed by Argonne was used to update the ICSM with historical sampling results and down-hole gamma survey information for hundreds of soil core locations; both sampling results and down-hole gamma data were coded to identify whether the results indicated the presence of contamination above site cleanup requirements. Significant effort was invested in developing complete electronic data sets for the site by incorporating data contained in various scanned documents, maps, etc. The updating process yielded both a best guess estimate of contamination volumes and upper and lower bounds on the volume estimate that reflected the estimate's uncertainty. The site-wide contaminated volume estimate (with associated uncertainty) was adjusted to reflect areas where remediation was complete; the result was a revised estimate of the remaining soil volumes requiring remediation that the USACE could use for planning. Other environmental projects may benefit from this process for estimating the volume of contaminated soil. A comparison of sample and DHG results for various stations with the site ICSM provides one measure of the quality of site understanding relative to the presence of contamination and its likely extent. A second measure of the quality of a contaminated soil volume estimate, in the case of BAASS, is a comparison of the best guess volume estimate with the conservative volume estimate. For Maywood, the conservative volume estimate is more than double the best guess. The data available for the site indicate that the preponderance of this difference is attributable to uncertainty about the exact depth of known contamination. The observed depth of contamination based on sample results and DHG data often varied significantly among adjacent soil cores. In the case of Maywood, where a significant amount of remediation has already taken place, a third measure of the quality of the volume estimates is the retrospective estimate of contaminated soil volumes for areas that have already been remediated [2]. The USACE is currently comparing the latest BAASS volume estimates for those areas with records indicating what was actually removed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Artificial Intelligence and Machine Learning for Bioenergy Research: Opportunities and Challenges

The integration of artificial intelligence and machine learning (AI/ML) with automated experimentation, genomics, biosystems design, and bioprocessing technologies is poised to revolutionize scientific investigation and, particularly, bioenergy research. To identify the opportunities and challenges in this emerging research area, the U.S. Department of Energy’s (DOE) Biological and Environmental Research program (BER) and Bioenergy Technologies Office (BETO) held a joint virtual workshop on AI/ML for Bioenergy Research (AMBER) on August 23–25, 2022. These interests have since been amplified in a September 2022 Executive Order, “Advancing Biotechnology and Biomanufacturing Innovation for a Sustainable, Safe, and Secure U.S. Bioeconomy,” to promote a whole-of government approach to biotechnology development (White House 2022). Approximately 50 scientists with various backgrounds and expertise from academia, industry, and DOE national laboratories met to discuss the opportunities and challenges of AI/ML for bioenergy research. Workshop participants were tasked with assessing the potential for AI/ML and laboratory automation to advance biological understanding and engineering in general. They particularly examined how integrating AI/ML tools with laboratory automation could accelerate biosystems design and optimize biomanufacturing. Discussions included the data and computational infrastructure needed to augment biosystems design applications and the expertise and workforce development efforts urgently required to shift integrated systems toward bioenergy research more broadly. Participants discussed many existing and future applications of AI/ML for biosystems design ranging from enzymes to plants and microbes, microbiomes, and bioprocess development. They also identified three key categories of scientific and technical opportunities and challenges: high-quality data, AI/ML algorithms, and laboratory automation. Several main takeaways emerged from the workshop: 1. Numerous AI/ML and automated experimentation applications exist for a variety of DOE mission needs in energy and the environment; 2. Exemplary research grand challenges for which AI/ML could provide solutions include: building microbes and microbial communities to specifications, developing closed-loop autonomous design and control for biosystems design, and advancing scale-up and automation; 3. Lack of sufficient high-quality, annotated data hinders the development of AI/ML applications; 4. New and improved AI/ML tools are needed, particularly those meeting the specific needs of the BER and BETO research communities; 5. Trade-offs in performance, cost, and reliability exist between deploying commercially available versus building custom-developed instrumentation and software for automated or autonomous experimentation; translation of manual to automated or autonomous methods is often a nontrivial endeavor; 6. Training a new generation of young scientists who can develop and apply AI/ML tools is needed to solve long-standing scientific challenges in bioenergy research. The integration of AI/ML tools and automated experimentation represents a new data-driven research paradigm complementary to the traditional hypothesis-driven research paradigm. This paradigm accelerates design and optimization of biological systems and processes for a variety of DOE mission needs in energy and the environment. The AMBER workshop broadly explored the potential of this new paradigm for bioenergy research, of particular interest to BER and BETO, and identified key challenges and opportunities that DOE can address in the coming years by leveraging its unique capabilities and resources.

59 BASIC BIOLOGICAL SCIENCES↗

Source apportionment: findings from the US supersites program

Receptor models are used to identify and quantify source contributions to particulate matter and volatile organic compounds based on measurements of many chemical components at receptor sites. These components are selected based on their consistent appearance in some source types and their absence in others. UNMIX, positive matrix factorization (PMF), and effective variance are different solutions to the chemical mass balance (CMB) receptor model equations and are implemented on available software. In their more general form, the CMB equations allow spatial, temporal, transport, and particle size profiles to be combined with chemical source profiles for improved source resolution. Although UNMIX and PMF do not use source profiles explicitly as input data, they still require measured profiles to justify their derived source factors. The U.S. Supersites Program provided advanced datasets to apply these CMB solutions in different urban areas. Still lacking are better characterization of source emissions, new methods to estimate profile changes between source and receptor, and systematic sensitivity tests of deviations from receptor model assumptions. 154 refs.

02 PETROLEUM↗

Color Transformations of Photometric Measurements of Galaxies in Optical and Near-infrared Wide-field Imaging Surveys*

Abstract Over the past 2 decades, wide-field photometric surveys in optical and infrared domains reached a nearly all-sky coverage thanks to numerous observational facilities operating in both hemispheres. However, subtle differences among exact realizations of Johnson and SDSS photometric systems require one to convert photometric measurements into the same system prior to analysis of composite data sets originating from multiple surveys. It turns out that the published photometric transformations lead to substantial biases when applied to integrated photometry of galaxies from the corresponding catalogs. Here we present photometric transformations based on piece-wise linear approximations of integrated photometry of galaxies in the optical surveys SDSS, DECaLS, BASS, MzLS, DES, DELVE, KiDS, VST ATLAS, and the near-infrared surveys UKIDSS, UHS, VHS, and VIKING. We validate our transformations by constructing k -corrected color–magnitude diagrams of non-active galaxies and measuring the position and tightness of the “red sequence.” We also provide transformations for aperture magnitudes and show how they are affected by the image quality difference among the surveys. We present the implementation of the derived transformations in python and idl and also a web-based color transformation calculator for galaxies. By comparing DECaLS and DES, we identified systematic issues in DECaLS photometry for extended galaxies, which we attribute to the photometric software package used by DECaLS. As an application of our method, we compiled two multi-wavelength photometric catalogs for over 200,000 low- and intermediate-redshift galaxies originating from CfA FAST and Hectospec spectral archives.

Astronomy & Astrophysics↗

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

PDFDataExtractor: A Tool for Reading Scientific Text and Interpreting Metadata from the Typeset Literature in the Portable Document Format

The layout of portable document format (PDF) files is constant to any screen, and the metadata therein are latent, compared to mark-up languages such as HTML and XML. No semantic tags are usually provided, and a PDF file is not designed to be edited or its data interpreted by software. However, data held in PDF files need to be extracted in order to comply with opensource data requirements that are now government-regulated. In the chemical domain, related chemical and property data also need to be found, and their correlations need to be exploited to enable data science in areas such as data-driven materials discovery. Such relationships may be realized using text-mining software such as the “chemistry-aware” natural-language-processing tool, ChemDataExtractor; however, this tool has limited data-extraction capabilities from PDF files. This study presents the PDFDataExtractor tool, which can act as a plug-in to ChemDataExtractor. It outperforms other PDF-extraction tools for the chemical literature by coupling its functionalities to the chemical-named entityrecognition capabilities of ChemDataExtractor. The intrinsic PDF-reading abilities of ChemDataExtractor are much improved. The system features a template-based architecture. This enables semantic information to be extracted from the PDF files of scientific articles in order to reconstruct the logical structure of articles. While other existing PDF-extracting tools focus on quantity mining, this template-based system is more focused on quality mining on different layouts. PDFDataExtractor outputs information in JSON and plain text, including the metadata of a PDF file, such as paper title, authors, affiliation, email, abstract, keywords, journal, year, document object identifier (DOI), reference, and issue number. With a self-created evaluation article set, PDFDataExtractor achieved promising precision for all key assessed metadata areas of the document text.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of an on-board imaging system for extremely rapid radiation therapy

Purpose: Next-generation extremely rapid radiation therapy systems could mitigate the need for motion management, improve patient comfort during the treatment, and increase patient throughput for cost effectiveness. Such systems require an on-board imaging system that is competitively priced, fast, and of sufficiently high quality to allow good registration between the image taken on the day of treatment and the image taken the day of treatment planning. In this study, three different detectors for a custom on-board CT system were investigated to select the best design for integration with an extremely rapid radiation therapy system. Methods: Three different CT detectors are proposed: low-resolution (all 4 × 4 mm pixels), medium-resolution (a combination of 4 × 4 mm pixels and 2 × 2 mm pixels), and high-resolution (all 1 × 1 mm pixels). An in-house program was used to generate projection images of a numerical anthropomorphic phantom and to reconstruct the projections into CT datasets, henceforth called “realistic” images. Scatter was calculated using a separate Monte Carlo simulation, and the model included an antiscatter grid and bowtie filter. Diagnostic-quality images of the phantom were generated to represent the patient scan at the time of treatment planning. Commercial deformable registration software was used to register the diagnostic-quality scan to images produced by the various on-board detector configurations. The deformation fields were compared against a “gold standard” deformation field generated by registering initial and deformed images of the numerical phantoms that were used to make the diagnostic and treatment-day images. Registrations of on-board imaging system data were judged by the amount their deformation fields differed from the corresponding gold standard deformation fields—the smaller the difference, the better the system. To evaluate the registrations, the pointwise distance between gold standard and realistic registration deformation fields was computed. Results: By most global metrics (e.g., mean, median, and maximum pointwise distance), the high-resolution detector had the best performance but the medium-resolution detector was comparable. For all medium- and high-resolution detector registrations, mean error between the realistic and gold standard deformation fields was less than 4 mm. By pointwise metrics (e.g., tracking a small lesion), the high- and medium-resolution detectors performed similarly. For these detectors, the smallest error between the realistic and gold standard registrations was 0.6 mm and the largest error was 3.6 mm. Conclusions: The medium-resolution CT detector was selected as the best for an extremely rapid radiation therapy system. In essentially all test cases, data from this detector produced a significantly better registration than data from the low-resolution detector and a comparable registration to data from the high-resolution detector. The medium-resolution detector provides an appropriate compromise between registration accuracy and system cost.

60 APPLIED LIFE SCIENCES↗

LLNL Response to the DOE ASCR RFI, "Stewardship of Software for Scientific and High-Performance Computing"

For decades, Lawrence Livermore National Laboratory (LLNL) has been engaged in significant research, development, and support for software to enable scientific computing and, particularly, the use of high performance computing (HPC) in the NNSA mission space. In particular, the move in the mid-1990’s to simulation as a leading component of stockpile stewardship through the ASCI and the successor ASC programs, as well as the need for reliable data acquisition and control software for the National Ignition Facility, have been important drivers in building expertise in production-quality software development at LLNL. LLNL has also been a leader in the DOE SciDAC FASTMath Institute and the DOE Exascale Computing Project (ECP), both of which have striven to make scientific computing software – in particular, the enabling technologies underpinning simulation capabilities – more widely adopted and sustainable. As such, we believe that our experience can inform the broader goal of software stewardship for scientific and high-performance computing. LLNL strongly supports the formation of a new DOE ASCR program element in software stewardship and sustainment. Historically, DOE ASCR has funded applied mathematics and computer science research that has led to the development of important new capabilities and algorithms that are expressed as artifacts in research software. Such frameworks, libraries, and tools have seldom been directly funded to address the important issues of code maintenance, documentation, robustness, and community building. Software engineering and support have typically been done on the side in support of the ASCR-driven research products. DOE funding priorities have been slow to recognize that good software engineering, the kind that ensures research investments have more adoption and longevity, requires significant resources. Based upon our experiences, we have prepared this response to highlight the concerns and issues we believe to be important as DOE ASCR considers its role in scientific software stewardship. We believe that role is important and will require a significant investment of new funding to legitimately support the technologies past and future DOE ASCR investments have and will produce to facilitate their uptake and adoption in the broader scientific computing community. Following a summary of our involvement in scientific software development, the remainder our response is organized around the nine topics specifically identified in the RFI.

97 MATHEMATICS AND COMPUTING↗

Ideas and perspectives: Enhancing research and monitoring of carbon pools and land-to-atmosphere greenhouse gases exchange in developing countries

Carbon (C) and greenhouse gas (GHG) research has traditionally required data collection and analysis using advanced and often expensive instruments, complex and proprietary software, and highly specialized research technicians. Partly as a result, relatively little C and GHG research has been conducted in resource-constrained developing countries. At the same time, these are often the same countries and regions in which climate change impacts will likely be strongest and in which major science uncertainties are centered, given the importance of dryland and tropical systems to the global C cycle. Increasingly, scientific communities have adopted appropriate technology and approach (AT&A) for C and GHG research, which focuses on low-cost and low-technology instruments, open-source software and data, and participatory and networking-based research approaches. Adopting AT&A can mean acquiring data with fewer technical constraints and lower economic burden and is thus a strategy for enhancing C and GHG research in developing countries. However, AT&A can have higher uncertainties; these can often be mitigated by carefully designing experiments, providing clear protocols for data collection, and monitoring and validating the quality of obtained data. For implementing this approach in developing countries, it is first necessary to recognize the scientific and moral importance of AT&A. At the same time, new AT&A techniques should be identified and further developed. All these processes should be promoted in collaboration with local researchers and through training local staff and encouraged for wide use and further innovation in developing countries.

Kim, Dong-Gill↗

Autonomous Navigation With Ground Station One-Way Forward-Link Doppler Data

The National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) has spent several years developing operational onboard navigation systems (ONS's) to provide real time autonomous, highly accurate navigation products for spacecraft using NASA's space and ground communication systems. The highly successful Tracking and Data Relay Satellite (TDRSS) ONS (TONS) experiment on the Explorer Platform/Extreme Ultraviolet (EP/EUV) spacecraft, launched on June 7, 1992, flight demonstrated the ONS for high accuracy navigation using TDRSS forward link communication services. In late 1994, a similar ONS experiment was performed using EP/EUV flight hardware (the ultrastable oscillator and Doppler extractor card in one of the TDRSS transponders) and ground system software to demonstrate the feasibility of using an ONS with ground station forward link communication services. This paper provides a detailed evaluation of ground station-based ONS performance of data collected over a 20 day period. The ground station ONS (GONS) experiment results are used to project the expected performance of an operational system. The GONS processes Doppler data derived from scheduled ground station forward link services using a sequential estimation algorithm enhanced by a sophisticated process noise model to provide onboard orbit and frequency determination. Analysis of the GONS experiment performance indicates that real time onboard position accuracies of better than 125 meters (1 sigma) are achievable with two or more 5-minute contacts per day for the EP/EUV 525 kilometer altitude, 28.5 degree inclination orbit. GONS accuracy is shown to be a function of the fidelity of the onboard propagation model, the frequency/geometry of the tracking contacts, and the quality of the tracking measurements. GONS provides a viable option for using autonomous navigation to reduce operational costs for upcoming spacecraft missions with moderate position accuracy requirements.

Horstkamp, G. M.↗

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗

Electron Microscopy and Image Analysis for Selected Materials

This particular project was completed in collaboration with the metallurgical diagnostics facility. The objective of this research had four major components. First, we required training in the operation of the environmental scanning electron microscope (ESEM) for imaging of selected materials including biological specimens. The types of materials range from cyanobacteria and diatoms to cloth, metals, sand, composites and other materials. Second, to obtain training in surface elemental analysis technology using energy dispersive x-ray (EDX) analysis, and in the preparation of x-ray maps of these same materials. Third, to provide training for the staff of the metallurgical diagnostics and failure analysis team in the area of image processing and image analysis technology using NIH Image software. Finally, we were to assist in the sample preparation, observing, imaging, and elemental analysis for Mr. Richard Hoover, one of NASA MSFC's solar physicists and Marshall's principal scientist for the agency-wide virtual Astrobiology Institute. These materials have been collected from various places around the world including the Fox Tunnel in Alaska, Siberia, Antarctica, ice core samples from near Lake Vostoc, thermal vents in the ocean floor, hot springs and many others. We were successful in our efforts to obtain high quality, high resolution images of various materials including selected biological ones. Surface analyses (EDX) and x-ray maps were easily prepared with this technology. We also discovered and used some applications for NIH Image software in the metallurgical diagnostics facility.

Williams, George↗

A Structured, Model-Based Systems Engineering Methodology for Operations System Design

Two widely accepted techniques for lowering the cost and risk of developing systems are (1) the use of a defined systems engineering (SE) process or methodology and (2) the reuse of existing (previously built) system components. The first technique is represented, for example, in materials published by NASA (e.g., NASA Systems Engineering Handbook) or by professional societies such as INCOSE (International Council on Systems Engineering). Well-formed SE techniques provide value by establishing the proper scope of the system (e.g., requirements), and by identifying and resolving problems relatively early in project lifecycles, when fixes are less expensive. The second technique (reuse) is applied most commonly to hardware and software; it seeks to avoid replicating design and implementation costs while also reducing risk by placing proven capabilities into operational use. In this paper, we outline a methodology combining these two techniques and extending reuse beyond hardware and software to foundational aspects of a Mission Operation System’s (MOS) design. We describe the system design artifacts that result (e.g., requirements, design documentation), as well as the reusable patterns and elements of the design, and their interrelationships. This approach is enabled by model-based systems engineering (MBSE) techniques and tools and is currently available in SysML form as a plug-in to MagicDraw. Additionally, usage of a rigorous MBSE approach allows for training materials and tutorials to be packaged within the overall model itself. The results of such an approach include decreased cost and risk during the design phase, improved ability of the MOS development team to investigate trade spaces and identify impacts to important flight-ground trade studies. Such results extend into decreased costs and risk in later phases due to improved design, decreased need for late fixes or development of "glue-ware" or scripts to fill unanticipated gaps in functionality, and improved ability to identify and plan testing and other validation activities. Finally, lower operational costs can be expected, both due to improved quality of the MOS, increased ease of maintaining updated knowledge of system configuration, and the fact that training and procedural materials are also updated at the same time as accepted system changes.

Bindschadler, Duane L.↗

GPM Ground Validation at NASA Wallops Precipitation Research Facility

The Wallops Precipitation Research Facility (WPRF) at NASA Goddard Space Flight Center, Wallops Island, VA has been established as a semi-permanent super-site for the Global Precipitation Measurement (GPM) Ground Validation (GV) program. WPRF is home to research quality precipitation instruments, including NASA’s S-band dual-polarimetric radar (NPOL), and a network of profiling radars, disdrometers, and rain gauges. This study investigates the statistical agreement of the GPM Core Observatory Dual Frequency Precipitation Radar (DPR), combined DPR-GPM Microwave Imager (GMI) and GMI Level II precipitation retrievals compared to WPRF ground observations from a six-year collection of satellite overpasses. Multi-sensor observations are integrated using the System for Integrating Multiplatform Data to Build the Atmospheric Column (SIMBA) software package. SIMBA ensures measurements recorded in a variety of formats are synthesized into a common reference frame for ease in comparison and analysis. Given that instantaneous satellite measurements are observed above ground level, this study investigates the possibility of a time lag between satellite and surface mass-weighted mean diameter (D(sub m)), reflectivity (Z), and precipitation rate (R) observations. Results indicate that time lags vary up to 30 minutes after overpass time but are not consistent between cases. In addition, GPM Core D(sub m) retrievals are within Level I mission science requirements as compared to WPRF ground observations. Results also indicate GPM algorithms overestimate light rain (< 1.0 mm hr(exp -1)). Two very different stratiform rain vertical profiles show differing results when compared to ground reference data. A key finding of this study indicates multi-sensor DPR/GMI combined algorithms outperform single sensor DPR algorithm.

Charanjit S Pabla↗

Dose-shaping using targeted sparse optimization

Purpose: Dose volume histograms (DVHs) are common tools in radiation therapy treatment planning to characterize plan quality. As statistical metrics, DVHs provide a compact summary of the underlying plan at the cost of losing spatial information: the same or similar dose-volume histograms can arise from substantially different spatial dose maps. This is exactly the reason why physicians and physicists scrutinize dose maps even after they satisfy all DVH endpoints numerically. However, up to this point, little has been done to control spatial phenomena, such as the spatial distribution of hot spots, which has significant clinical implications. To this end, the authors propose a novel objective function that enables a more direct tradeoff between target coverage, organ-sparing, and planning target volume (PTV) homogeneity, and presents our findings from four prostate cases, a pancreas case, and a head-and-neck case to illustrate the advantages and general applicability of our method.Methods: In designing the energy minimization objective (E{sub tot}{sup sparse}), the authors utilized the following robust cost functions: (1) an asymmetric linear well function to allow differential penalties for underdose, relaxation of prescription dose, and overdose in the PTV; (2) a two-piece linear function to heavily penalize high dose and mildly penalize low and intermediate dose in organs-at risk (OARs); and (3) a total variation energy, i.e., the L{sub 1} norm applied to the first-order approximation of the dose gradient in the PTV. By minimizing a weighted sum of these robust costs, general conformity to dose prescription and dose-gradient prescription is achieved while encouraging prescription violations to follow a Laplace distribution. In contrast, conventional quadratic objectives are associated with a Gaussian distribution of violations, which is less forgiving to large violations of prescription than the Laplace distribution. As a result, the proposed objective E{sub tot}{sup sparse} improves tradeoff between planning goals by 'sacrificing' voxels that have already been violated to improve PTV coverage, PTV homogeneity, and/or OAR-sparing. In doing so, overall plan quality is increased since these large violations only arise if a net reduction in E{sub tot}{sup sparse} occurs as a result. For example, large violations to dose prescription in the PTV in E{sub tot}{sup sparse}-optimized plans will naturally localize to voxels in and around PTV-OAR overlaps where OAR-sparing may be increased without compromising target coverage. The authors compared the results of our method and the corresponding clinical plans using analyses of DVH plots, dose maps, and two quantitative metrics that quantify PTV homogeneity and overdose. These metrics do not penalize underdose since E{sub tot}{sup sparse}-optimized plans were planned such that their target coverage was similar or better than that of the clinical plans. Finally, plan deliverability was assessed with the 2D modulation index.Results: The proposed method was implemented using IBM's CPLEX optimization package (ILOG CPLEX, Sunnyvale, CA) and required 1-4 min to solve with a 12-core Intel i7 processor. In the testing procedure, the authors optimized for several points on the Pareto surface of four 7-field 6MV prostate cases that were optimized for different levels of PTV homogeneity and OAR-sparing. The generated results were compared against each other and the clinical plan by analyzing their DVH plots and dose maps. After developing intuition by planning the four prostate cases, which had relatively few tradeoffs, the authors applied our method to a 7-field 6 MV pancreas case and a 9-field 6MV head-and-neck case to test the potential impact of our method on more challenging cases. The authors found that our formulation: (1) provided excellent flexibility for balancing OAR-sparing with PTV homogeneity; and (2) permitted the dose planner more control over the evolution of the PTV's spatial dose distribution than conventional objective functions. In particular, E{sub tot}{sup sparse}-optimized plans for the pancreas case and head-and-neck case exhibited substantially improved sparing of the spinal cord and parotid glands, respectively, while maintaining or improving sparing for other OARs and markedly improving PTV homogeneity. Plan deliverability for E{sub tot}{sup sparse}-optimized plans was shown to be better than their associated clinical plans, according to the two-dimensional modulation index.Conclusions: These results suggest that our formulation may be used to improve dose-shaping and OAR-sparing for complicated disease sites, such as the pancreas or head and neck. Furthermore, our objective function and constraints are linear and constitute a linear program, which converges to the global minimum quickly, and can be easily implemented in treatment planning software. Thus, the authors expect fast translation of our method to the clinic where it may have a positive impact on plan quality for challenging disease sites.

61 RADIATION PROTECTION AND DOSIMETRY↗