Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines↗

Electromagnetic position sensor for a magnetically supported model in a wind tunnel

An investigation was undertaken to determine the feasibility of using superconducting force-producing coils for positioning a model in a wind tunnel. The cryostat containing the forcing coils surrounded the test section of the tunnel, thus favoring an electromagnetic position sensor. Another reason favoring this choice was the fact that the performance of an electromagnetic sensor is essentially unaffected by the shape of the model.

Towler, W. R.↗

An experimental and theoretical study of the flow phenomena within a vortex sink rate sensor

A description of the flow field within a vortex sink rate sensor was obtained, and the influence of viscous effects on its performance was observed. The sensor basically consisted of a vortex chamber and a sink tube. The vortex chamber consisted of two circular coaxial disks held apart, at their periphery, by a porous coupling. One circular disk had an opening to permit the mounting of the sink tube, in such a manner that the vortex chamber as well as the sink tube had a common axis of rotation. Air was supplied radially to the sensor through its porous coupling as the sensor was rotated at various speeds. Particular emphasis was directed toward an understanding of the flow field in the sink tube region. Thus velocity measurements at various stations along the length of the sink tube as well as along a given radius at any designated station were taken.

Patel, D. K.↗

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines↗

Design Optimization and Measurement Uncertainty of an Electromagnetic Level Sensor for Liquid Metal Reactors

Here, this article describes the design and operation of a prototype mutual inductance level sensor (MILS) and the development and validation of a finite-element analysis (FEA) model describing its behavior. The MILS was designed for use in liquid sodium up to temperatures of 650 °C in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). Preliminary testing was performed in a room temperature test stand with aluminum acting as an analog for the sodium to better understand sensor performance and provide accurate code validation data. This experimental data, along with material properties found in literature, were used to validate an FEA model in ANSYS Maxwell. The validated ANSYS Maxwell model was used to examine the performance of the MILS in various environments and under various operating conditions. Simulations suggest the following: The MILS will perform adequately in liquid sodium and liquid lead at temperatures up to 650 °C . The temperature dependence of electrical conductivity imposes a temperature dependence on the sensor that requires proper compensation. The MILS signal sensitivity is maximized when mutual inductance between sensor coils is maximized, and sensor geometry should be selected to account for this factor. The operating frequency of the MILS can be optimized and is dependent on process fluid material, operating temperature, and materials/geometry of sensor system. Finally, the use of a stainless-steel isolating thimble does not adversely affect the sensor signal. The primary sources of error for this MILS system are the accuracy of the calibration standard against which the sensor is calibrated, and the temperature dependence of the sensor. This work contains all the necessary details to recreate the FEA model and results. This model can be used to optimize the performance of a MILS in any operating environment to read any electrically conductive working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Active control of sound transmission/radiation from elastic plates by vibration inputs. II - Experiments

Actively controlled harmonic force inputs were applied experimentally to reduce the sound transmitted through an elastic circular plate. The control implementation used a time domain least mean square adaptive algorithm with two error sensors. The control forces were applied directly to the plate by point force vibration inputs, while the error information and performance were measured in the radiated acoustic field by microphones. Test cases were also performed in which the error sensors were accelerometers mounted on the plate. When accelerometers were used as error sensors, the controller performance was degraded; leading to the conclusion that minimizing plate motion does not necessarily lead to an associated decrease in radiated sound levels. In contrast, the results show excellent attenuation of the transmitted sound field when microphone error sensors were used. This result was consistent over a range of frequencies. In addition, the experimental results are compared to previously derived analytical results and the effect of using a point or global minimization scheme is discussed.

Metcalf, V. L.↗

Achievable Performance and Effective Interrogator Design for SAW RFID Sensor Tags

For many NASA missions, remote sensing is a critical application that supports activities such as environmental monitoring, planetary science, structural shape and health monitoring, non-destructive evaluation, etc. The utility of the remote sensing devices themselves is greatly increased if they are passive V that is, they do not require any on-board power supply such as batteries V and if they can be identified uniquely during the sensor interrogation process. Additional passive sensor characteristics that enable greater utilization in space applications are small size and weight, long read ranges with low interrogator power, ruggedness, and operability in extreme environments (vacuum, extreme high/low temperature, high radiation, etc.) In this paper, we consider one very promising passive sensor technology, called surface acoustic wave (SAW) radio-frequency identification (RFID), that satisfies all of these criteria. In general, RFID is a method of identifying items using radio waves to interrogate tags encoded with a unique identifier that are affixed to the items of interest. In the case of passive tags, only the interrogator, which transmits power to the tags in the form of radio-frequency electromagnetic radiation, requires access to a power supply. Passive RFID technologies are used today in many applications, including asset tracking and management, security and access control, and remote sensing. To date, most of the development and application in RFID technology has focused on either asset/inventory tracking and control or security and access control because these are the largest commercial application areas. Recently however, there has been growing interest in using passive RFID technology for remote sensing applications, and SAW devices are at the forefront of RFID sensing technology development. Although SAW RFID tags have great potential for use in numerous space-based remote sensing applications, the limited collision resolution capability of current generation tags limits the performance in a cluttered sensing environment. That is, as more SAW-based sensors are added to the environment, numerous tag responses are superimposed at the receiver and decoding all or even a subset of the telemetry becomes increasingly difficult. Background clutter generated by reflectors other than the sensors themselves is also a problem, as is multipath interference and signal distortion, but the limiting factor in many remote sensing applications can be expected to be tag mutual interference. This problem may be greatly mitigated by proper design of the SAW tag waveform, but that remains an open research problem, and in the meantime, several other related questions remain to be answered including: (1) What are the fundamental relationships between tag parameters such as bit-rate, time-bandwidth-product, SNR, and achievable collision resolution? (2) What are the differences in optimal or near-optimal interrogator designs between noise-limited environments and interference-limited environments? (3) What are the performance characteristics of different interrogator designs in term of parameters such as transmitter power level, range, and number of interfering tags? In this paper, we will present the results of a research effort aimed at providing at least partial answers to all of these questions.

Barton Richard J.↗

Proposed evaluation framework for assessing operator performance with multisensor displays

Despite aggressive work on the development of sensor fusion algorithms and techniques, no formal evaluation procedures have been proposed. Based on existing integration models in the literature, an evaluation framework is developed to assess an operator's ability to use multisensor, or sensor fusion, displays. The proposed evaluation framework for evaluating the operator's ability to use such systems is a normative approach: The operator's performance with the sensor fusion display can be compared to the models' predictions based on the operator's performance when viewing the original sensor displays prior to fusion. This allows for the determination as to when a sensor fusion system leads to: 1) poorer performance than one of the original sensor displays (clearly an undesirable system in which the fused sensor system causes some distortion or interference); 2) better performance than with either single sensor system alone, but at a sub-optimal (compared to the model predictions) level; 3) optimal performance (compared to model predictions); or, 4) super-optimal performance, which may occur if the operator were able to use some highly diagnostic 'emergent features' in the sensor fusion display, which were unavailable in the original sensor displays. An experiment demonstrating the usefulness of the proposed evaluation framework is discussed.

Foyle, David C.↗

Development of ASTM International D8405—Standard Test Method for Evaluating PM 2.5 Sensors or Sensor Systems Used in Indoor Applications

Sensors and sensor systems for monitoring fine particles with aerodynamic diameters smaller than 2.5 µm can provide real-time feedback on indoor air quality and thus can help guide actions to manage indoor air pollutant concentrations. Standardized verification of the performance and accuracy of sensors and sensor systems is crucial for predicting the efficacy of such monitoring. A new ASTM International standard test method (ASTM D8405) was created for this need and is the most exacting laboratory protocol published to date for evaluating indoor air quality sensors and sensor systems measuring particles smaller than 2.5 µm in diameter. ASTM D8405 subjects sensors and sensor systems to five test phases: (1) an initial particle concentration ramp; (2) exposure to various temperature and humidity conditions; (3) exposure to interfering particles; (4) temperature cycling; and (5) a final particle concentration ramp to assess drift. This paper discusses the development of the standard test method, key aspects of the testing process, example evaluation results, and a comparison of this standard test method against peer evaluation protocols.

47 OTHER INSTRUMENTATION↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Acquisition, pointing and tracking performance of the Hubble Space Telescope fine guidance sensors

The three fine guidance sensors (FGSs) on board the HST have been operated extensively since the observatory was launched in April, 1990. The FGSs, each capable of measuring angles as small as 0.003 arcsec, provide required fine pointing information to the HST's pointing control system and are intended to serve as astrometry instruments. On-orbit data have shown that the acquisition, pointing and tracking performance of the FGSs in most cases meets, and of these sometimes exceeds, requirements. The versatility of the FGS digital control electronics to adapt to the unexpected conditions imposed on the sensors by the telescope spherical aberration and by solar panel jitter is discussed. There is encouragement from both on-orbit tests and analytical studies that the FGSs can accommodate the current telescope characteristics. Improvements to guide star acquisitions within the FGSs and to target acquisitions within science instruments have been accomplished with the internal distortion calibration of each FGS and with the alignment calibration between sensors. Techniques used in the calibration process and the resulting improvements in acquisitions are presented.

Eaton, David J.↗

Sixteen Years of Terra MODIS On-Orbit Operation, Calibration, and Performance

Terra MODIS has successfully operated for more than 16 years since its launch in December 1999. From its observations, many science data products have been generated in support of a broad range of research activities and remote sensing applications. Terra MODIS has operated in a number of configurations and experienced a few anomalies, including spacecraft and instrument related events. MODIS collects data in 36 spectral bands that are calibrated regularly by a set of on-board calibrators for their radiometric, spectral, and spatial performance. Periodic lunar observations and long-term radiometric trending over well-characterized ground targets are also used to support sensor on-orbit calibration. Dedicated efforts made by the MODIS Characterization Support Team (MCST) and continuing support from the MODIS Science Team have contributed to the mission success, enabling well-calibrated data products to be continuously generated and routinely delivered to users worldwide. This paper presents an overview of Terra MODIS mission operations, calibration activities, and instrument performance of the past 16 years. It illustrates and describes the results of key sensor performance parameters derived from on-orbit calibration and characterization, such as signal-to-noise ratio (SNR), noise equivalent temperature difference (NEdT), solar diffuser (SD) degradation, changes in sensor responses, center wavelengths, and band-to-band registration (BBR). Also discussed in this paper are the calibration approaches and strategies developed and implemented in support of MODIS Level 1B data production and re-processing, major challenging issues, and lessons learned. (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Xiong, X.↗

Assessment of the Impact of Realistic Sensor Physics and the Integration of Ex-Core Sensors on Reactor Power Synthesis

In the work documented in this report, a weighting function–based core power synthesis method was applied to multiple Monte Carlo N-Particle (MCNP) reactor models, which are informed based on simulated self-powered neutron detector (SPND) responses. The weighting function method used has been coined the point-based iterative (PBI) method. The goal of this application is to assess the impact of considering realistic sensor physics in the generation of the simulated SPND outputs as well as to consider how the synthesis is impacted based on the inclusion of ex-core detectors in the model. The NuScale small modular reactor (SMR) and Westinghouse AP1000 pressurized water reactor (PWR) are the models that served as the testbeds for the assessment of realistic sensor physics; this was achieved by using Geant4 SPND models in comparison with analytical models, such that the effect of electron transport in realistic SPND geometries in the Geant4 model can be understood in terms of synthesis error and convergence time. The comparison was considered for fuel burnup–induced perturbations, for a range of sensor string densities and synthesized power distribution axial fidelities. The Texas A&M Testing, Research, Isotopes, General Atomics Reactor (TAMU TRIGA) reactor MCNP model was used to assess the impact of ex-core sensors; this was done by performing synthesis with and without the ex-core detectors and by quantifying the synthesis error and number of iterations associated with Gaussian-type perturbations in many locations in the core. The TAMU TRIGA model was particularly pertinent for this study because of the interest in future experimental tests with SPNDs in this reactor, as well as the ease of modifying the MCNP model to include ex-core detectors with heterogeneously described response functions. Results from the comparison between the Geant4 and analytical SPND models indicate that similar average and maximum synthesis errors were obtained for burnup-induced perturbations in both the NuScale SMR and the AP1000. This was true for a range of sensor string densities and axial fidelities. However, there were marked differences between both the Geant4 and analytically informed models in terms of the iterations required to converge on the synthesized power distribution. Namely, the Geant4-informed models tended to lead to fewer iterations, except for a few sensor–core configurations that had particularly numerous iterations. Results from the ex-core sensor assessment with the TAMU TRIGA model indicate that the inclusion of ex-core sensors drastically reduces the synthesis error of Gaussian-type perturbations close to the edge of the core, and it slightly reduces synthesis errors for perturbations closer to the center of the core. This was achieved with a minimal increase in computational cost—that is, the number of iterations required for convergence. The errors were identified to be in the same location as the perturbation in the core, indicating that the methodology remains robust for unperturbed regions of the core. A secondary result from this study with the TAMU TRIGA was yielded by analysis of the neutron flux levels in the in-core and ex-core sensor locations of the core; these flux levels indicate that SPNDs could be used as both in-core and ex-core sensors, so long as the emitter material is sensitive to thermal neutrons. The results from these studies provide a quantitative understanding of the importance of considering realistic sensor physics and including ex-core sensors to perform accurate and timely power distribution synthesis of a reactor core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Controllable oxygen vacancy defect engineering of BiVO 4 porous structures for room temperature NH 3 detection

Controlling structural features of sensing material while judiciously introducing vacancy defect states for revamping the electronic properties of the sample to obtain its superior gas sensing performance, is quite rare. Herein, we report for the first time, the room temperature (RT) ammonia (NH 3 ) detection of peanut-like porous bismuth vanadate (BiVO 4 ) with a stable monoclinic phase. The developed BiVO 4 possess abundant oxygen vacancies and porosity by virtue of calcinations (400–800 ℃). BiVO 4 calcined at 400 ℃ exhibits high selectivity towards NH 3 with a maximum response of 1421 @ 270 ppm at RT, which is 2.5 fold enhanced compared to without calcined BiVO 4 (response of 547 @ 270 ppm NH 3 ). The oxygen defective BiVO 4 appeared highly durable and stable even under high humid conditions (∼60 %). Besides, the porosity of BiVO 4 not only enhances the specific surface area (19.8 m 2 /g) but also results in fast diffusion of NH 3 molecules, leading to a reduction in the decay time (34 s for 90 ppm NH 3 ). The density functional theory (DFT) uncovers that the oxygen vacancy formation in BiVO 4 augments the NH 3 sensing capabilities by enhancing the adsorption energy of NH 3 . This work provides insight into the sensing mechanism of increased response caused by defect engineering and porosity, which will be favourable for fabricating high-performance NH 3 sensors at RT.

DFT analysis↗

Heliostat optical error inspection with polarimetric imaging drone

On a Concentrated Solar Power (CSP) field, optical errors have significant impacts on the collection efficiency of heliostats. Fast, cost-effective, labor-efficient, and non-intrusive autonomous field inspection remains a challenge. Approaches using imaging drone, i.e., Unmanned Aerial Vehicle (UAV) system integrated with high resolution visible imaging sensors, have been developed to address these challenges; however, these approaches are often limited by insufficient imaging contrast. Here, in this study, we report a polarimetry-based method with a polarization imaging system integrated on UAV to enhance imaging contrast for in-situ detection of heliostat mirrors without interrupting field operation. We developed an optical model for skylight polarization pattern to simulate the polarization images of heliostat mirrors and obtained optimized waypoints for polarimetric imaging drone flight path to capture images with enhanced contrast. The polarimetric imaging-based method improved the success rate of edge detections in scenarios which were challenging for mirror edge detection with conventional imaging sensors. We have performed field tests to achieve significantly enhanced heliostat edge detection success rate and investigate the feasibility of integrating polarimetric imaging method with existing imaging-based heliostat inspection methods, i.e., Polarimetric Imaging Heliostat Inspection Method (PIHIM). Our preliminary field test results suggest that the PIHIM hold the promise to enable sufficient imaging contrast for real-time autonomous imaging and detection of heliostat field, thus suitable for non-interruptive fast CSP field inspection during its operation.

CSP Field↗

Emergent topological polarization textures in relaxor ferroelectrics

Relaxor ferroelectrics underpin high-performance actuators and sensors, yet the nature of polar heterogeneities driving their broadband dielectric response remains debated. Using a unified, multimodal structural refinement framework— simultaneously fitting complementary X-ray and neutron total scattering, X-ray absorption spectra, and diffuse scattering—we reconstruct 3D mesoscale polarization maps in the classic relaxor system PbMg 1/3 Nb 2/3 O 3 –PbTiO 3 . We uncover self-organized swirling polarization textures with half-skyrmion (meron) vortices, challenging models of independent polar nanoregions. These textures, characterized by smooth changes in the polarization direction, originate from overlapping volumes in which the projections of locally correlated polarization vectors onto each volume’s long axis share the same sign. Vortex cores correlate strongly with local charge and strain gradients imposed by compositional heterogeneities. In this work, our results suggest that chemical disorder, acting via depolarizing and strain fields, stabilizes topological vortex textures of the polarization field, offering a route for engineering new dielectric and ferroelectric functionalities.

Eremenko, Maksim [National Institute of Standards ↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗