Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Thin-Entrance Window Process for Soft X-Ray Sensors

New free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250 eV to 1.5 KeV. Achieving adequately shallow entrance windows is challenging because the high temperature anneal needed to activate the dopant also drives the dopant profile deeper, growing the region that is insensitive to soft x-rays. A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. The microwave anneal technique can activate dopants at low substrate temperature, with minimal dopant diffusion, and can be used to fabricate both n-type and p-type entrance windows. SRP and SIMS measurements were used to verify dopant activation with negligible dopant diffusion. We then applied the microwave anneal process to a planar sensor wafer, using the new process to create the backside diode contact. Electrical test of the resulting sensors shows good reverse bias characteristics. The sensors have been bump-bonded to a read-out ASIC and used successfully to measure an Fe-55 x-ray spectrum. Process and device simulations were performed to characterize the quantum efficiency of the entrance window for soft x-rays. This technique is useful for other sensor applications requiring a shallow entrance window, including detectors for UV photons, low energy ions and low energy electrons.

47 OTHER INSTRUMENTATION↗

Sensor Incipient Fault Impacts on Building Energy Performance: A Case Study on a Multi-Zone Commercial Building

Existing studies show sensor faults/error could double building energy consumption and carbon emissions compared with the baseline. Those studies assume that the sensor error is fixed or constant. However, sensor faults are incipient in real conditions and there were extremely limited studies investigating the incipient sensor fault impacts systematically. This study filled in this research gap by studying time-developing sensor fault impacts to rule-based controls on a 10-zone office building. The control sequences for variable air volume boxes (VAV) with an air handling unit (AHU) system were selected based on ASHRAE Guideline 36-2018: High-Performance Sequences of Operation for HVAC Systems. Large-scale simulations on cloud were conducted (3600 cases) through stochastic approach. Results show (1) The site energy differences could go –3.3% lower or 18.1% higher, compared with baseline. (2) The heating energy differences could go –66.5% lower or 314.4% higher, compared with baseline. (3) The cooling energy differences could go –11.5% lower or 65.0% higher, compared with baseline. (4) The fan energy differences could go 0.15% lower or 6.9% higher, compared with baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wireless Passive Ceramic Sensor for Far-Field Temperature Measurement at High Temperatures

A passive wireless high-temperature sensor for far-field applications was developed for stable temperature sensing up to 1000 °C. The goal is to leverage the properties of electroceramic materials, including adequate electrical conductivity, high-temperature resilience, and chemical stability in harsh environments. Initial sensors were fabricated using Ag for operation to 600 °C to achieve a baseline understanding of temperature sensing principles using patch antenna designs. Fabrication then followed with higher temperature sensors made from (In, Sn) O2 (ITO) for evaluation up to 1000 °C. A patch antenna was modeled in ANSYS HFSS to operate in a high-frequency region (2.5–3.5 GHz) within a 50 × 50 mm2 confined geometric area using characteristic material properties. The sensor was fabricated on Al2O3 using screen printing methods and then sintered at 700 °C for Ag and 1200 °C for ITO in an ambient atmosphere. Sensors were evaluated at 600 °C for Ag and 1000 °C for ITO and analyzed at set interrogating distances up to 0.75 m using ultra-wideband slot antennas to collect scattering parameters. The sensitivity (average change in resonant frequency with respect to temperature) from 50 to 1000 °C was between 22 and 62 kHz/°C which decreased as interrogating distances reached 0.75 m.

47 OTHER INSTRUMENTATION↗

Near-Field Passive Wireless Sensor for High-Temperature Metal Corrosion Monitoring

This work focuses on the fabrication and evaluation of a passive wireless sensor for the monitoring of the temperature and corrosion of a metal material at high temperatures. An inductor–capacitor (LC) resonator sensor was fabricated through the screen printing of Ag-based inks on dense polycrystalline Al 2 O 3 substrates. The LC design was modeled using the ANSYS HFSS modeling package, with the LC passive wireless sensors operating at frequencies from 70 to 100 MHz. The wireless response of the LC was interrogated and received by a radio frequency signal generator and spectrum analyzer at temperatures from 50 to 800 °C in real time. The corrosion kinetics of the Cu 110 was characterized through thermogravimetric (TGA) analysis and microscopy images, and the oxide thickness growth was then correlated to the wireless sensor signal under isothermal conditions at 800 °C. The results showed that the wireless signal was consistent with the corrosion kinetics and temperature, indicating that these two characteristics can be further deconvoluted in the future. In addition, the sensor also showed a magnitude- and frequency-dependent response to crack/spallation events in the oxide corrosion layer, permitting the in situ wireless identification of these catastrophic events on the metal surface at high temperatures.

36 MATERIALS SCIENCE↗

Industrial Wireless Sensors: A User's Perspective on the Impact of Standards on Wide-spread Deployment

The role of wireless sensing technologies in industrial instrumentation will undoubtedly become more important in the years ahead. . Deployment of such instrumentation in an industrial setting with its heightened security and robustness criteria hinges on user acceptance of verified performance as well as meeting cost requirements. Today, industrial users face many choices when specifying a wireless sensor network, including radio performance, battery life, interoperability, security, and standards compliance. The potential market for industrial wireless sensors is literally millions of wireless instruments and it is imperative that accurate information for applying the technology to real-world applications be available to the end-user so that they can make informed deployment decisions. The majority of industrial wireless automation designs now being deployed or being considered for deployment are based on three different standards . The HART Communications Foundation s WirelessHART (IEC 62591), the International Society of Automation s ISA100.11a, and the offering from the Industrial Wireless Alliance of China known as WIA-PA (IEC 62601). Aside from these industrial automation standards, users must also be cognizant of the underlying wireless network standards IEEE 802.11, IEEE 802.15.4, and IEEE 802.15.3a and their interactions with the three principal industrial automation protocols mentioned previously. The crucial questions being asked by end users revolve around sensor network performance, interoperability, reliability, and security. This paper will discuss potential wireless sensor applications in power plants, barriers to the acceptance of wireless technology, concerns related to standards, and provide an end user prospective on the issues affecting wide-spread deployment of wireless sensors. Finally, the authors conclude with a discussion of a recommended path forward including how standards organizations can better facilitate end user decision making and how end users can locate and use objective information for decision making.

99 GENERAL AND MISCELLANEOUS↗

How do A-train Sensors Intercompare in the Retrieval of Above-Cloud Aerosol Optical Depth? A Case Study-based Assessment

We inter-compare the above-cloud aerosol optical depth (ACAOD) of biomass burning plumes retrieved from different A-train sensors, i.e., MODIS, CALIOP, POLDER, and OMI. These sensors have shown independent capabilities to detect and retrieve aerosol loading above marine boundary layer clouds--a kind of situation often found over the Southeast Atlantic Ocean during dry burning season. A systematic one-to-one comparison reveals that, in general, all passive sensors and CALIOP-based research methods derive comparable ACAOD with differences mostly within 0.2 over homogeneous cloud fields. The 532-nm ACAOD retrieved by CALIOP operational algorithm is largely underestimated; however, it’s 1064-nm AOD when converted to 500 nm shows closer agreement to the passive sensors. Given the different types of sensor measurements processed with different algorithms, the close agreement between them is encouraging. Due to lack of adequate direct measurements above cloud, the validation of satellite-based ACAOD retrievals remains an open challenge. The inter-satellite comparison, however, can be useful for the relative evaluation and consistency check.

54 ENVIRONMENTAL SCIENCES↗

Surface-Mediated Interconnections of Nanoparticles in Cellulosic Fibrous Materials toward 3D Sensors

Fibrous materials serve as an intriguing class of 3D materials to meet the growing demands for flexible, foldable, biocompatible, biodegradable, dis- posable, inexpensive, and wearable sensors and the rising desires for higher sensitivity, greater miniaturization, lower cost, and better wearability. The use of such materials for the creation of a fibrous sensor substrate that interfaces with a sensing film in 3D with the transducing electronics is however difficult by conventional photolithographic methods. Here, a highly effective pathway featuring surface-mediated interconnection (SMI) of metal nanoclusters (NCs) and nanoparticles (NPs) in fibrous materials at ambient conditions is demon- strated for fabricating fibrous sensor substrates or platforms. Bimodally distrib- uted gold–copper alloy NCs and NPs are used as a model system to demonstrate the semiconductive-to-metallic conductivity transition, quantized capacitive charging, and anisotropic conductivity characteristics. Upon coupling SMI of NCs/NPs as electrically conductive microelectrodes and surface-mediated assembly (SMA) of the NCs/NPs as chemically sensitive interfaces, the resulting fibrous chemiresistors function as sensitive and selective sensors for gaseous and vaporous analytes. Finally, this new SMI–SMA strategy has significant implications for manufacturing high-performance fibrous platforms to meet the growing demands of the advanced multifunctional sensors and biosensors.

36 MATERIALS SCIENCE↗

Sequential optimal positioning of mobile sensors using mutual information

Source localization, such as detecting a nuclear source in an urban area or ascertaining the origin of a chemical plume, is generally regarded as a well-documented inverse problem; however, optimally placing sensors to collect data for such problems is a more challenging task. In particular, optimal sensor placement—that is, measurement locations resulting in the least uncertainty in the estimated source parameters—depends on the location of the source, which is typically unknown a priori. Mobile sensors are advantageous because they have the flexibility to adapt to any given source position. While most mobile sensor strategies designate a trajectory for sensor movement, we instead employ mutual information, based on Shannon entropy, to choose the next measurement location from a discrete set of design conditions.

97 MATHEMATICS AND COMPUTING↗

Tuning SPT-3G Transition-Edge-Sensor Electrical Properties with a Four-Layer Ti–Au–Ti–Au Thin-Film Stack

We have developed superconducting Ti transition-edge sensors with Au protection layers on the top and bottom for the South Pole Telescope’s third-generation receiver (a cosmic microwave background polarimeter, due to be upgraded this austral summer of 2017/2018). The base Au layer (deposited on a thin Ti glue layer) isolates the Ti from any substrate effects; the top Au layer protects the Ti from oxidation during processing and subsequent use of the sensors. We control the transition temperature and normal resistance of the sensors by varying the sensor width and the relative thicknesses of the Ti and Au layers. The transition temperature is roughly six times more sensitive to the thickness of the base Au layer than to that of the top Au layer. The normal resistance is inversely proportional to sensor width for any given film configuration. For widths greater than five micrometers, the critical temperature is independent of width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Scalable Readout for Microwave SQUID Multiplexing of Transition-Edge Sensors

The readout requirements for instruments based on transition-edge sensors (TESs) have dramatically increased over the last decade as demand for systems with larger arrays and faster sensors has grown. Emerging systems are expected to contain many thousands of sensors and/or sensors with time constants as short as 100 ms. These requirements must be satisfied while maintaining low noise, high dynamic range, and low crosstalk. A promising readout candidate for future TES arrays is the microwave SQUID multiplexer, which offers several gigahertz of readout bandwidth per pair of coaxial cables. In microwave SQUID multiplexing, sensor signals are coupled to RF-SQUIDs embedded in superconducting microwave resonators, which are probed via a common microwave feedline and read out using gigahertz signals. This form of SQUID multiplexing moves complexity from the cryogenic stages to room temperature hardware and digital signal processing firmware which must synthesize the microwave tones and process the information contained within them. To demultiplex signals from the microwave SQUID multiplexer, we have implemented an FPGA-based firmware architecture that is flexible enough to read out a variety of differently optimized TESs. A gamma-ray spectrometer targeted at nuclear materials accounting applications, known as SLEDGEHAMMER, is an early adopter of microwave SQUID multiplexing and is driving our current firmware development effort. This instrument utilizes 300 kHz full-width half-maximum resonators with 256 channels in a one gigahertz wide band. We have recently demonstrated undegraded readout of 128 channels using two ROACH2s on a single pair of coaxial cables. This manuscript describes the firmware implementation for the readout electronics of these early array-scale demonstrations.

42 ENGINEERING↗

Broadband Calibration of Acoustic Emission and Ultrasonic Sensors from Generalized Ray Theory and Finite Element Models

This paper describes a calibration method for acoustic emission and ultrasonic sensors that is effective from 1 kHz to 1 MHz. The method combines generalized ray theory and finite element analysis to model wave propagation at higher and lower frequencies, respectively. A ball impact is used as a calibration source, a thick aluminum plate is used as the test block, and hot glue is used as the couplant. We demonstrate this method on five commercial piezoelectric sensors: Physical Acoustics (PAC) R15a, PAC WSa, Panametrics V101, Panametrics V103, and Valpey-Fisher Pinducer. Our calibration results show that reflections and other wave phases can be more clearly identified with the less-resonant Panametrics sensors. The PAC sensors have the greatest sensitivity and are able to detect surface normal displacements at least down to 1 pm amplitude in the 100s of kHz frequency band. Aperture effect is minimized by the small size of the Pinducer. Our method focuses on the amplitude response of the sensors (phase is ignored) and extends the calibration to a frequency band that is lower than typical analyses. Low frequency information is useful for determining the seismic moment of a seismic source (analogous to the magnitude of an earthquake) and can increase the amount of information acquired in a single recording.

42 ENGINEERING↗

Design of Fluxgate Sensors for Different Applications from Geology to Medicine

In this study, we have shown that fluxgate sensors can be used for different application areas. Alternative sensor configurations have been developed for three different application areas. These are mainly rod- and ring-type fluxgate sensors. In the first study, a measurement system with the rod-type fluxgate sensor has been developed in order to monitor the local magnetic field distributions on a magnetic tape (e.g., credit card). With this system, the magnetic recording data on the credit card were measured and imaged successfully. The second and the third application areas, which are monitoring the influence of solar storms on the earth field and heartbeat analysis of mankind, were carried out by using a ring-core fluxgate sensor geometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bio-compatible and highly sensitive two-dimensional plasmonic sensor

We propose a novel bio-compatible two dimensional plasmonic sensor with array of ring and the hole structure on an optically thick gold film for biochemical sensing. We use finite-difference time-domain simulation for design and calculation of sensitivity in the near-infrared region. The bio-compatible and cheap plasmonic glycerol sensor with high sensitivity by interferometer style as a motif in the sensor’s structure. The proposed sensor can be applied as highly sensitivity sensor with a good linear response under different glycerol concentrations.

42 ENGINEERING↗

Graphene oxide coated side polished surface plasmon resonance optical fibre sensor with varying polishing losses

Four batches of side-polished SMF optical fibres with different polishing losses, − 0.5 dBm, − 5 dBm, − 10 dBm and − 15 dBm were coated with a graphene oxide layer of ~ 0.5 μm via drop casting. TE polarized light was propagated through the light during experiments and four different transformer oils with different water contents were dropped onto the sensor. The drop in the power of transmitted light was recorded. The responses of the sensors showed good linearity for all, but the least polished fibre showed the weakest response in terms of power drop towards change in concentration. The − 5 dBm fibre showed the best response per unit concentration change. Additional tests showed the increased response for a GO coated side polished sensor compared to an uncoated side polished sensor. Simulation using COMSOL was performed to show the effects on the electric field of a sensor with and without GO coating. Another set of simulations were performed to show the effects of reducing cladding thickness on the coupling of the electric field. Simulations show that the optimal cladding thickness is not the most polished fibre, coinciding with our results that − 15 dBm loss fibre did not show the most response per unit change in the analyte.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ethanol Monitoring Gas Sensor Based on Flower-Shaped Copper Sulfide by a Facile Hydrothermal Method for Marine Transportation

Flower-shaped CuS as a p-type gas-sensing material was synthesized by a facile hydrothermal method in this study. Morphology, structure, and chemical composition of the synthesized CuS gas-sensing material were analyzed by SEM, XRD, XPS, and N{sub 2} adsorption adsorption–desorption technique. Gas-sensing properties of the as-prepared CuS sensors were also investigated toward ethanol monitoring. The results showed that the flower-like CuS nanostructures consisted of interconnected nanosheets and exhibited good crystallinity. With the increase in ethanol concentration, the sensitivity of the CuS sensor significantly increased and indicated a roughly linear relationship at the optimal operating temperature of 260 °C. The ethanol-selective characteristics of the CuS sensor against other interfering gases including methanol, benzene, dichloromethane, and hexane were studied, and the gas response of the CuS sensor synthesized at 170 °C toward 100 ppm ethanol was 5.22, which was significantly higher than all the other gases. Moreover, 14-day continuous measurement further confirmed the excellent stability of the CuS sensor.

36 MATERIALS SCIENCE↗

A multi-objective optimization approach to optimal sensor location problem in $\mathrm{IGCC}$ power plants

Integrated Gasification Combined Cycle (IGCC) power plants provide a cleaner and more efficient way to obtain energy from coal. In order to operate an IGCC power plant in a safe and stable manner, several input and output process parameters need to be monitored. However, due to economic and operational constraints, it is infeasible to place sensors at every input and output process parameter location. Hence, it becomes important to select the most effective sensor locations which lead to maximum information gain about the plant conditions. Practical issues present in an IGCC power plant, such as harsh physical conditions and variability in process parameters, make the optimal sensor location problem an especially complicated one. Further, sensors can have multiple objectives and they can produce uncertainties due to measurement errors. Here this work considers hybrid hardware and virtual sensing for advanced power systems with multiple objectives. In order to solve this real world large scale problem, we use a novel algorithm called Better Optimization of Nonlinear Uncertain Systems (BONUS). BONUS works in probability distribution space and avoids sampling for each optimization and derivative calculations iterations. A new algorithm for multi-objective optimization is also developed specifically for problem. The result of this nonlinear stochastic multi-objective problem is the non-dominated, or Pareto set, which provides trade-offs between various objectives like observability, cost, and thermal efficiency. This is the first attempt at solving the problem of optimal sensor deployment in advanced power plants, with consideration of hybrid hardware and virtual sensing and incorporation of uncertainty with multiple objectives.

01 COAL, LIGNITE, AND PEAT↗

Dynamic model-based sensor network design algorithm for system efficiency maximization

Here, a dynamic model-based sensor network design (DMSND) algorithm has been developed for maximizing system efficiency for an estimator-based control system. The algorithm synthesizes the optimal sensor network in the face of disturbances or set point changes. Computational expense of the large-scale combinatorial optimization problem is significantly reduced by parallel computing and by using combination of three novel strategies: multi-rate sampling frequency, model order reduction, and use of an incumbent solution that enables early termination of evaluation of infeasible sensor sets. The developed algorithm is applied to an acid gas removal unit as part of an integrated gasification combined cycle power plant with carbon capture. Even though there are more than thousand process states and more than hundred candidate sensor locations, the optimal sensor network design problem for maximizing process efficiency could be solved within couple of hours for a given budget.

47 OTHER INSTRUMENTATION↗

Thermal effects of an ICL-based mid-infrared CH 4 sensor within a wide atmospheric temperature range

Here, thermal effects of an interband cascade laser (ICL) based mid-infrared methane (CH 4 ) sensor that uses long-path absorption spectroscopy were studied. The sensor performance in the laboratory at a constant temperature of ~ 25°C was measured for 5 hours and its Allan deviation was ~ 2 ppbv with a 1 s averaging time. A LabVIEW-based simulation program was developed to study thermal effects on infrared absorption and a temperature compensation technique was developed to control such effects. An environmental test chamber was employed to investigate thermal effects that occur in the sensor system with variation of the test chamber temperature between 10 and 30°C. The thermal response of the sensor in a laboratory setting was observed using a 2.1 ppm CH 4 standard gas sample. indoor/outdoor CH 4 measurements were conducted to evaluate the sensor performance within a wide atmospheric temperature range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗