Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

On optimizing the sensor spacing for pressure measurements on wind turbine airfoils

This research article presents a robust approach to optimizing the layout of pressure sensors around an airfoil. A genetic algorithm and a sequential quadratic programming algorithm are employed to derive a sensor layout best suited to represent the expected pressure distribution and, thus, the lift force. The fact that both optimization routines converge to almost identical sensor layouts suggests that an optimum exists and is reached. By comparing against a cosine-spaced sensor layout, it is demonstrated that the underlying pressure distribution can be captured more accurately with the presented layout optimization approach. Conversely, a 39 %–55 % reduction in the number of sensors compared to cosine spacing is achievable without loss in lift prediction accuracy. Given these benefits, an optimized sensor layout improves the data quality, reduces unnecessary equipment and saves cost in experimental setups. While the optimization routine is demonstrated based on the generic example of the IEA 15 MW reference wind turbine, it is suitable for a wide range of applications requiring pressure measurements around airfoils.

17 WIND ENERGY↗

Flux Sensor Measurement and Calibration Requirements for High-Intensity Heat Flux Applications: A Trade Study

Stakeholders of CSP and non-CSP high-intensity broadband flux measurements were surveyed and interviewed to obtain flux sensor design and calibration requirements. Existing sensor technologies and existing calibration facilities were then compared against this standard. Stakeholders require a flux sensor designed for >5,000 kW/m2 flux measurements, >1,000 life cycles, <500 ms response time, >60-minute exposure at maximum flux, and <5% measurement uncertainty. Stakeholders also require a sensor with minimal cost, short procurement lead time, and a high-intensity broadband flux calibration. Commercial CSP stakeholders primarily rely on infrared (IR) temperature measurements of receiver equipment to control CSP plant process operation, whereas CSP research and development (R&D) and non-CSP stakeholders rely on accurate flux gauge measurements for a variety of applications. It was determined that existing flux sensor technologies and calibration facilities do not comprehensively meet stakeholder needs. This study suggests a more robust circular foil gauge with a high-intensity solar flux calibration comprehensively meets stakeholder flux measurement needs. Improved circular foil gauge designs and an improved flux sensor calibration facility are discussed.

McLaughlin, Luke (ORCID:0000000303711310)↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Study of payload sensor contamination

Epoxy/glass test specimens representing Scout fourth and fifth stage motor casings were prepared and studied in a test program designed to determine the relative contamination contributed to payload sensors located near the motor casings. The relative contamination detected in the test program was dependent on several factors, including: (1) distance of test specimen to sensor, (2) sensor temperature, (3) geometric position of the sensor (relative to test specimen), (4)test specimen temperature, (5) chemical composition of the test specimen, (6) sensor function, and (7) additional materials (such as adhesive-backed aluminum tape) added to the test specimens. The thermal characteristics and the decomposition and outgassing products were determined. These data were used to better understand the relative contamination data from the remote sensor testing.

Smith, F. J.↗

Investigation of substrate-mounted thin-film meteoroid sensors for use in large area impact experiments

Two types of sensor designs were investigated: (1)a polysulfone dielectric film with vapor-deposited aluminum and gold sensor plates, bonded to a relatively thick aluminum substrate, and (2) an aluminum oxide (A1203) dielectric layer prepared on an aluminum substrate by anodization, with a layer of vapor-deposited aluminum providing one sensor plate and the substrate serving as the other plate. In the first design, specimens were prepared which indicate the state of the art for application of this type of sensor for elements of a meteoroid detection system having an area as large as 10 sq M. Techniques were investigated for casting large-area polysulfone films on the surface of water and for transferring the films from the water. Methods of preparing sensors by layering of films, the deposition of capacitor plates, and sensor film-to-substrate bonding, as well as techniques for making electrical connections to the capacitor plates, were studied.

Carollo, S. F.↗

Flight calibration tests of a nose-boom-mounted fixed hemispherical flow-direction sensor

Flight calibrations of a fixed hemispherical flow angle-of-attack and angle-of-sideslip sensor were made from Mach numbers of 0.5 to 1.8. Maneuvers were performed by an F-104 airplane at selected altitudes to compare the measurement of flow angle of attack from the fixed hemispherical sensor with that from a standard angle-of-attack vane. The hemispherical flow-direction sensor measured differential pressure at two angle-of-attack ports and two angle-of-sideslip ports in diametrically opposed positions. Stagnation pressure was measured at a center port. The results of these tests showed that the calibration curves for the hemispherical flow-direction sensor were linear for angles of attack up to 13 deg. The overall uncertainty in determining angle of attack from these curves was plus or minus 0.35 deg or less. A Mach number position error calibration curve was also obtained for the hemispherical flow-direction sensor. The hemispherical flow-direction sensor exhibited a much larger position error than a standard uncompensated pitot-static probe.

Armistead, K. H.↗

Measurement of the vibration of structures with a three-component vibration sensor

The effects of transverse waves and longitudinal displacements on transverse displacements in a plate are studied using a three component vibration sensor. Limitations of using the sensor in such measurements are: (1) sensor connection to the plate leads to changes in transverse displacement points on the plate surface, (2) the sensor has a finite magnitude of selectivity with respect to vibrations in the direction of the different channel axes, (3) longitudinal displacements of plate surface create restrictions on relative sensitivity of sensor to longitudinal-transverse waves, and (4) tranverse displacement of plate surface during longitudinal wave propagation also creates a restriction on sensor sensitivity to transverse waves.

Yeskov, V. V.↗

Manipulation based on sensor-directed control: An integrated end effector and touch sensing system

A hand/touch sensing system is described that, when mounted on a position-controlled manipulator, greatly expands the kinds of automated manipulation tasks that can be undertaken. Because of the variety of coordinate conversions, control equations, and completion criteria, control is necessarily dependent upon a small digital computer. The sensing system is designed both to be rugged and to sense the necessary touch and force information required to execute a wide range of manipulation tasks. The system consists of a six-axis wrist sensor, external touch sensors, and a pair of matrix jaw sensors. Details of the construction of the particular sensors, the integration of the end effector into the sensor system, and the control algorithms for using the sensor outputs to perform manipulation tasks automatically are discussed.

Hill, J. W.↗

Sensor development in the Shuttle era

The use of the Space Shuttle in the development of earth observation sensors is examined. Two sensor classes are selected for case histories: infrared temperature sounders and microwave radiometers. The most significant finding in each of the developmental studies of these two sensor classes is considered to be the feasibility and value of using the Shuttle/Spacelab as a test vehicle for the operation in space of a versatile multimode experimental sensor. The Shuttle Electrically Scanned Microwave Radiometer and the Shuttle Infrared Interferometer are found to be the most effective instruments in this context. The Shuttle/Spacelab Sortie mission characteristics provide opportunities for new approaches to the development of sensors, using the Shuttle as a test vehicle to improve the efficiency of the process with respect to time, cost, and/or quality of the final product. As for crew functions, the short-term Spacelab mission requires some near real-time evaluation of data quality and sensor function in order to insure efficient data collection.

Gerding, R. B.↗

A miniature 48-channel pressure sensor module capable of in situ calibration

A new high data rate pressure sensor module with in situ calibration capability has been developed by the Langley Research Center to help reduce energy consumption in wind-tunnel facilities without loss of measurement accuracy. The sensor module allows for nearly a two order of magnitude increase in data rates over conventional electromechanically scanned pressure sampling techniques. This module consists of 16 solid state pressure sensor chips and signal multiplexing electronics integrally mounted to a four position pressure selector switch. One of the four positions of the pressure selector switch allows the in situ calibration of the 16 pressure sensors; the three other positions allow 48 channels (three sets of 16) pressure inputs to be measured by sensors. The small size of the sensor module will allow mounting within many wind-tunnel models, thus eliminating long tube lengths and their corresponding slow pressure response.

Gross, C.↗

Electronically scanned pressure sensor module with in SITU calibration capability

This high data rate pressure sensor module helps reduce energy consumption in wind tunnel facilities without loss of measurement accuracy. The sensor module allows for nearly a two order of magnitude increase in data rates over conventional electromechanically scanned pressure sampling techniques. The module consists of 16 solid state pressure sensor chips and signal multiplexing electronics integrally mounted to a four position pressure selector switch. One of the four positions of the pressure selector switch allows the in situ calibration of the 16 pressure sensors; the three other positions allow 48 channels (three sets of 16) pressure inputs to be measured by the sensors. The small size of the sensor module will allow mounting within many wind tunnel models, thus eliminating long tube lengths and their corresponding slow pressure response.

Gross, C.↗

OAST Space Theme Workshop. Volume 3: Working group summary. 3: Sensors (E-3). A. Statement. B. Technology needs (form 1). C. Priority assessment (form 2). D. Additional assessment

Developments required to support the space power, SETI, solar system exploration and global services programs are identified. Instrumentation and calibration sensors (rather than scientific) are needed for the space power system. Highly sophisticated receivers for narrowband detection of microwave sensors and sensors for automated stellar cataloging to provide a mapping data base for SETI are needed. Various phases of solar system exploration require large area solid state imaging arrays from UV to IR; a long focal plane telescope; high energy particle detectors; advanced spectrometers; a gravitometer; and atmospheric distanalyzer; sensors for penetrometers; in-situ sensors for surface chemical analysis, life detection, spectroscopic and microscopic analyses of surface soils, and for meteorological measurements. Active and passive multiapplication sensors, advanced multispectral scanners with improved resolution in the UV and IR ranges, and laser techniques for advanced probing and oceanographic characterization will enhance for global services.

Source record↗

Analysis and preliminary design of optical sensors for propulsion control

A fiber-optic sensor concept screening study was performed. Twenty sensor subsystems were identified and evaluated. Two concepts selected for further study were the Fabry-Perot fiber-optic temperature sensor and the pulse-width-modulated phosphorescent temperature sensor. Various designs suitable for a Fabry-Perot temperature sensor to be used as a remote fiber-optic transducer were investigated. As a result, a particular design was selected and constructed. Tests on this device show that spectral peaks are produced from visible white light, and the change in wavelength of the spectral peaks produced by a change in temperature is consistent with theory and is 36 nm/C for the first order peak. A literature search to determine a suitable phosphor for implementing the pulse-width-modulated fiber optic temperature sensor was conducted. This search indicated that such a device could be made to function for temperatures up to approximately 200 C. Materials like ZnCdS and ZnSe activated with copper will be particularly applicable to temperature sensing in the cryogenic to room temperature region. While this sensing concept is probably not applicable to jet engines, the simplicity and potential reliability make the concept highly desirable for other applications.

James, K. A.↗

In situ ozone data for evaluation of the laser absorption spectrometer ozone remote sensor: 1979 southeastern Virginia urban plume study summer field program

Ozone data from the 1979 Southeastern Virginia Urban Study (SEV-UPS) field program are presented. The SEV-UPS was conducted for evaluation of an ozone remote sensor, the Laser Absorption Spectrometer. During the measurement program, remote-sensor evaluation was in two areas; (1) determination of the remote sensor's accuracy, repeatability, and operational characteristics, and (2) demonstration of the application of remotely sensed ozone data in air-quality studies. Data from six experiments designed to provide in situ ozone data for evaluation of the sensor in area 1, above, are presented. Experiments consisted of overflights of a test area with the remote sensor aircraft while in situ measurements with a second aircraft and selected surface stations provided correlative ozone data within the viewing area of the remote sensor.

Gregory, G. L.↗

Flight test results for the F-8 digital fly-by-wire aircraft control sensor analytic redundancy management technique

This paper reviews the formulation and flight test results of an algorithm to detect and isolate the first failure of any one of twelve duplex control sensor signals being monitored. The technique uses like-signal differences for fault detection while relying upon analytic redundancy relationships among unlike quantities to isolate the faulty sensor. The fault isolation logic utilizes the modified sequential probability ratio test, which explicitly accommodates the inevitable irreducible low frequency errors present in the analytic redundancy residuals. In addition, the algorithm uses sensor output selftest, which takes advantage of the duplex sensor structure by immediately removing a highly erratic sensor from control calculations and analytic redundancy relationships while awaiting a definitive fault isolation decision via analytic redundancy. This study represents a proof of concept demonstration of a methodology that can be applied to duplex or higher flight control sensor configurations and, in addition, can monitor the health of one simplex signal per analytic redundancy relationship.

Deckert, J. C.↗

A miniature electro-optical air flow sensor

Miniature sensors are needed for rapid and uncomplicated installation on light aircraft engaged in stability research programs. One particularly difficult sensor to miniaturize to the required degree has been a flow angle and velocity sensor for measuring the local flow ahead of a wing. However, by using an electrooptical technique it was possible to overcome the encountered difficulties and to design a sensor satisfying the requirements. The developed sensor for measuring angle-of-attack, yaw, and airspeed was shown to be suitable for rapid instrumentation of research aircraft because of its small size. The size reduction was accomplished by a design feature which eliminates the need for slip rings and wiring within the movable components of the sensor.

Kershner, D. D.↗

Development of advanced high-temperature heat flux sensors

Various configurations of high temperature, heat flux sensors were studied to determine their suitability for use in experimental combustor liners of advanced aircraft gas turbine engines. It was determined that embedded thermocouple sensors, laminated sensors, and Gardon gauge sensors, were the most viable candidates. Sensors of all three types were fabricated, calibrated, and endurance tested. All three types of sensors met the fabricability survivability, and accuracy requirements established for their application.

Atkinson, W. H.↗

Cloud cover sensor

An apparatus is described which provides a numerical indication of the cloudiness at a particular time of a day. The apparatus includes a frame holding several light sensors such as photovoltaic cells, with a direct sensor mounted to directly face the Sun and indirect sensors mounted to face different portions of the sky not containing the Sun. A light shield shields the direct sensor from most of the sky except a small portion containing the Sun, and also shields each of the indirect sensors from direct sunlight. The relative values of the outputs from the direct and indirect sensors, enables the generation of a numerical indication of the degree of cloudiness at a particular time of day.

Laue, E. G.↗