Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “seals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Fabrication and Characterization of Plutonium Targets for Irradiation in the Flattop Critical Assembly

In FY16, Pu targets were fabricated in support of the Nuclear Physics: Cumulative Fission Product Yields (Fission R-values) task of the F2016 venture project; these targets are suitable for irradiation in the Flattop critical assembly at the Nevada National Security Site (NNSS). This report documents an overview of the target design, preparation of the Pu metal materials by removing the oxide layer and appropriate sizing for the target holders, target fabrication including filling an inner aluminum cup with the Pu material and the sealing of an outer stainless steel capsule, target assay using gamma spectroscopy, and the He leak testing of the final targets. Four targets were fabricated with two containing 99% 239 Pu metal and two containing 93% 239 Pu metal. Additional samples of each material were set aside for mass spectrometric analysis at PNNL and Los Alamos National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multifamily Air Leakage Evaluation: A Modular Case Study

The purpose of this case study is to compare the air leakage rates of modular and site-built multifamily dwelling units. The methods, materials, and equipment were observed to be very similar in the modular and site-constructed units in this case study. The installation quality of building envelope measures such as insulation and air barrier appeared to be better for modular construction, because they were installed in a controlled, factory setting. Through field observations, we identified cosmetic damage to the envelope of modular units following transport to the building site, but with no resulting significant air leakage pathways. However, we did see air leakage pathways resulting from field modifications to the envelope of modular units to accommodate structural and mechanical connections. We found that the extensive use of through-wall HVAC systems, combined with the transport, placement, and rework of modular units may compromise the high-quality envelope installation and airtightness observed in the factory without careful planning and/or design. Opportunities for improvement identified from the tested modular dwelling units include minimizing and optimally locating penetrations, pre-cutting and detailing penetrations at the factory where possible, properly sealing field modifications, and using split HVAC systems in place of through-wall packaged systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of radiolytic hydrogen generation from surrogate zr-based materials in a "mini-canister"

This report describes a test campaign to investigate radiolytic hydrogen generation from surrogate materials resembling the (Zr-based) cladding of commercial spent nuclear fuel (SNF) with an inventory of residual water post-dryout. The radiolytic hydrogen generation rates from residual waters in the SNF-in-canister system are important for predicting the in-canister environment for sealed SNF dry storage canisters over time and the impact to continued safe dry storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Homomorphic Encryption for Machine Learning and Artificial Intelligence Applications

Third-party and expert analysis is a cost-effective solution for solving specialized problems or processing large datasets related to reactor structural health monitoring and nondestructive evaluation. However, when handling proprietary information, third-party and expert analysts pose a privacy risk. To address this challenge, Homomorphic Encryption (HE) permits arithmetic operations on encrypted data without exposing the underlying data. Implementations of Machine Learning (ML) and Artificial Intelligence (AI) algorithms using HE greatly enhances the capabilities of third-party analysts while maintaining a low security risk. This paper details current success in applying Principal Component Analysis (PCA) and Fully Connected Neural Networks (NN) using the Microsoft SEAL implementation of the popular CKKS Fully Homomorphic Encryption (FHE) algorithm. The MNIST Handwritten Dataset is analyzed as a proof-of-concept demonstration of the implementations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mutual Inductance Level Sensor for Use in Liquid Metals

Electromagnetic instrumentation capable of measuring the level of liquid metal has been developed at Argonne National Laboratory’s (ANL) Mechanisms Engineering Test Loop (METL). The mutual inductance level sensor (MILS) utilizes the electromagnetic coupling between two coil conductors and a surrounding liquid metal to determine the level of the liquid metal. Mineral insulated cables wrapped on a stainless steel core provide a durable sensor construction. The use of a sealed stainless steel thimble isolates the sensor from the high-temperature liquid metal, allowing for easy sensor maintenance. Modern digital electronics allow for reliable and accurate operation of the sensor. Two sensor variations have been designed and fabricated, and the first variation has seen extensive testing in a non-sodium testing stand as well as in the high-temperature sodium environment of METL. Electromagnetic finite-element analysis studies have been performed using the COMSOL Magnetic Fields Solver. Regular operation of the MILS will commence following in-situ calibration of the sensors in the METL environment.

36 MATERIALS SCIENCE↗

MIS Shelf-Life Final Report for Plutonium Oxide Item CAN92 (SSR147) from Rocky Flats Analytical Laboratory Operations

A plutonium/uranium oxide material from the Material Identification and Surveillance (MIS) Program inventory has been studied to determine the gas generation and corrosion behavior in a storage environment. Sample CAN92 represents plutonium/uranium oxides stored in 3013 containers. The material originated in the analytical laboratory at Rocky Flats. This study followed over time the gas pressure and composition of a sample with nominally 0.5 wt% water in a sealed container with an internal volume scaled to 1/400th of the volume of a 3013 container. Gas compositions had been measured periodically over 5 ½ years. The maximum observed gas pressure from gas generation was 117 kPa. The increase over the initial pressure of 77.5 kPa was largely due to the generation of nitrogen and carbon dioxide with minor amounts of hydrogen and nitrous oxide. The internal components of SSR147 were inspected 6.5 years after it was removed from the array. The inside surfaces of the inner bucket exposed to the original sample for 1,937 days had an etched appearance and general corrosion. No pitting was observed on the inner bucket that held the sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of the Insoluble Solids of the 241-17F and 241-49H Pump house Water Sample

Six different water samples from 241-17F and 241-49H pump house were analyzed for chemical and physical characteristics as part of efforts to understand recent mechanical seal failures associated with four new cooling water pumps. A focus of this work was characterization of any “as found” insoluble solids. The insoluble material found in the FCRW (F-Area caustic water treated with sodium chromate at 241-17F) sample are mostly magnetite (Fe3O4 or possibly equipment rust) and silica. It was found that 26% of measured FCRW particles have at least one dimension larger than 15 microns. The insoluble particles found in the source water, domestic water (FDW), are mostly kaolin (aluminosilicate) and some iron oxide. All found FDW particles were larger than 15 microns. The insoluble particles of the other source water, FArea well water (FWW), were mostly iron oxide with some trapped cations like calcium. Only 8% of found FWW particles were bigger than 15 microns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

Perspectives on Response to an Abnormal Radiological Event [Slides]

On May 2, 2019, a sealed radioactive source containing cesium-137 was breached at the University of Washington Harborview Research and Training (HRT) Building in downtown Seattle while attempting to recover the source for the National Nuclear Security Administration’s (NNSA’s) Off-site Source Recovery Program (OSRP). The breach of the source resulted in the contamination of personnel, large sections of the building, and a release of material to the local environment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

International Workshop on Security of Radioactive Sources during Extraordinary Events

On May 2, 2019, a subcontractor to Los Alamos National Laboratory (LANL) inadvertently breached a sealed Cs-137 source while attempting to remove the source for disposition as part of a United States (US) government-sponsored program. The source breach resulted in contamination of personnel, the building, and a release of material to the local environment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Embedded acoustic sensing and monitoring techniques for small modular reactors

The goal of this project was to study the applicability of specific innovative instrumentation techniques for assessing parameters needed for safe small modular reactor operation and safeguarding of nuclear material. Small modular reactor core designs are currently being developed to provide energy more effectively and efficiently than in the past because they can be built as modules at fabrication sites and then transported to a power-producing facility. However, these modules and/or the final core will often be sealed and not accessible again until disposal. Instead of instruments that access the core directly, during and after operation, to monitor flux/dose and structural integrity, as current power plants use, new sensors need to be designed that can be built into the reactor initially to determine operating history, structural integrity through operation of the system, and nuclear material accountancy after shutdown and before disposition of the core. Embedded sensors already exist that can provide neutron flux, gamma dose, and temperatures, but techniques to expand upon these for assessing structural health and material inventory in the system over time need to be developed. Structural health assessments include the detection and imaging of cracks in the components that could eventually cause radioactive fission products to be released.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY2022 Filter Test for TRU Waste Drum Prototype Unit

Continuing last year’s (fiscal year 2021) work, a prototype instrument and an NPI-6 Integrated Work Document (IWD) were developed to assess the functionality of filters on transuranic waste containers (commonly called 55 Gallon ring-top drums) without requiring the removal of the drum lid. The purpose of this work is to determine the air flow and pressure characteristics associated with filter clogging, filter pressure drop at a fixed flow rate, and leakage around the lid seal. The FY22 objectives included: (A) Development of prototype device, (B) Drafting an IWD document, (C) Defining a filter clogging parameter, (D) Assessing filter damage due to over-pressure events, and (E) A path forward to obtain approval of the system safety filters in compliance with P101-16 Industrial Ventilation – non HVACR (LANL 2022).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Atomistic Materials Modeling of High-Pressure Hydrogen Interactions in Ethylene Propylene Diene Monomer (EPDM) Rubber

Elastomeric rubbers serve a vital role as sealing materials in the hydrogen storage and transport infrastructure. With applications including O-rings and hose-liners, these components are exposed to pressurized hydrogen at a range of temperatures, cycling rates, and pressure extremes. Cyclic (de)pressurization is known to degrade these materials through the process of cavitation. This readily visible failure mode occurs as a fracture or rupture of the material and is due to the oversaturated gas localizing to form gas bubbles. Computational modeling in the Hydrogen Materials Compatibility Program (H-Mat), co-led by Sandia National Laboratories and Pacific Northwest National Laboratory, employs multi-scale simulation efforts to build a predictive understanding of hydrogen-induced damage in materials. Modeling efforts within the project aim to provide insight into how to formulate materials that are less sensitive to high-pressure hydrogen-induced failure. In this document, we summarize results from atomistic molecular dynamics simulations, which make predictive assessments of the effects of compositional variations in the commonly used elastomer, ethylene propylene diene monomer (EPDM).

08 HYDROGEN↗

Testing and Qualification of Molybdenum Subcapsule Welds for MiniFuel Experiments

This report documents the testing and qualification efforts for welding molybdenum components to support MiniFuel irradiation campaigns. Other details such as general weld parameters, weld joint geometries, and performance limits are also provided in this report. The American Welding Society’s specifications were used to select the nondestructive and destructive tests, which include: gross and fine leak testing, internal pressure proof testing, and creating metallographic mounts of welds. Leak testing and metallographic mounts provide qualitative information about the weld integrity, while the proof testing indicated pressure/usage limits of the molybdenum subcapsule. Based on the testing results provided in the is report, the capsule can be exposed to an internal pressure of at least 20.7 MPa (3000 psi). A sealed capsules is also capable of withstanding the 3.2 MPa (468 psi) external hydrostatic operating pressure of the High Flux Isotope Reactor.

42 ENGINEERING↗

Chromium Tolerant, Highly Active and Stable Electrocatalytic Internal Surface Coating for Cathode of Commercial SOFCs (Final Report)

This project is aimed to develop a chromium (Cr) tolerant, highly active, and stable coating layer on the internal surfaces of the porous composite cathode from commercially available SOFCs. Such coating layer was developed using the additive manufacturing process of Atomic Layer Deposition (ALD) and has been applied on the cathode consisting of either an electronic conductor of LaxSr 1-x MnyO 3-δ (LSM) or mixed ionic and electronic conducting La x Sr 1-x Co y Fe 1-y O 3-δ (LSCF). PI's work has demonstrated that the internal surface of cathode from the commercial cells, can be further tailored using ALD coating to dramatically enhance the cell performance. For instance, ALD layer consisting heterostructured nano composite of nano-Pt and nano-(Mn 0.8 Co 0.2 ) 3 O 4 oxide on the internal surface of porous LSM/YSZ cathode from SOFCs, has resulted in the large reduction of the cell polarizations resistance by up to 53%, and enormous increase of power density over 370%. For the cells with LSCF/Sm 2 O 3 doped CeO 2 (SDC) cathode, the conformal layer of nano-composite consisting of superjacent CoOx and subjacent minimum amount of Pt nano-grains has resulted in the power density enhancement by 126% for the large scale industry tubular cells at 750°C, and both the performance enhancement and nanostructure of the ALD layer are stable over ~ 2000 h continuous operation performed at industry test station. In the meanwhile, those ALD coating layer developed by PI's work is also inherently Cr-tolerant, and could act as physical barrier for preventing Cr diffusion into the cathode backbone, so as to mitigate the Cr poisoning effect on the cathode. In this project, the impact of Cr on the performance of those ALD coated commercial cells has been evaluated. Based on evolution of the cell performance, the ALD coating layer chemistry and ALD coating layer thickness has been optimized to maximize the overall Cr tolerance, cell power density and cell longevity. Different ALD coating has been applied onto the internal surface of LSM/YSZ and LSCF/SDC backbone respectively. The architecture/scaffold structures on the internal surface of different cathode, designed by this project, was catalogued and analyzed using High Resolution Transmission Electron Microscopy (HRTEM), and cell power/durability performance are assured via comprehensive electrochemical performance testing in the industry operation relevant conditions. The impact of the electrochemical operation current density, the water humidity, the cell operation temperature, and cell operation duration on the Cr tolerance of ALD coated cells has been systematically investigated. There is completely different nanostructure degradation mechanisms between LSM and LSCF cells induced by Cr contamination. For the LSCF/SDC baseline cell, With the Cr source, there is no apparent Sr surface segregation phase even for the baseline cell operated for 3000 h at 750 °C. With the Cr source, there is significant amorphous (SrCr)Ox phase accumulated in the original pore region. For the commercial baseline cells, Cr contaminants on the LSM electrode severely impacted the entire cell's electrochemical performance and nanostructure degradation. Those degradations include (1). Peak power density loss of 64 % after 109 h of operation. The dramatic increase in Rp (2). They are cracking at LSM/SSZ interface, LSM grains. SSZ remains intact but with (CrMn)Ox. By contrast, ALD coating (MnCo)Ox/Pt dramatically improves the Cr resistance, as follows (1). ALD-coated cell with a power density is 280-380 % of the baseline cell, depending on the ALD layer thickness. (2). For a cell with a 20 nm thick ALD layer, there is a large performance enhancement (> 200 % power density) induced by ALD coating of Cr-tolerant Mn 0.8 Co 0.2 Ox. (3). For a cell with a 20 nm thick ALD layer, after 168 h at 750 °C power density of the ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination for 109 h. The ALD coating on the internal surface of cathode developed by this project integrated multi-functions. Those multi-functions include (1). Dramatically improving the cell power density for the commercial cells; (2). Dramatically improving contamination resistance of the cathode, for being an excellent protection coating layer sealing off Cr contamination. (3). Dramatically increasing the cell longevity by potentially preventing the microstructure evolution and grain coarsening of the cathode. Overall, this project will provide a simple solution to simultaneously enhance power density and increase the reliability, robustness, and endurance of commercial SOFCs, over the entire operating temperature range of 650-800 °C. For the inherently functional SOFC, the ALD coating of LSM based cathode mitigate the Cr-contamination. Power density of ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination. In addition to SOFCs, the novel on-demand design approach and creation of multifunctional heterogeneous architecture on the electrode surface presented in this work opens further research for their application in other types of fuel cells, batteries, and sensors for which electrochemical reactions on the surface are similarly critical.

36 MATERIALS SCIENCE↗

Automated, Unmanned Detection and Quantification of Fugitive Methane Emissions

Compressor stations used to move natural gas are one of the largest sources of fugitive methane emissions in the midstream sector, accounting for approximately 50% of all fugitive emissions (Zimmerle et al., 2015). This problem is most widespread at reciprocating compressors (Subramanian et al., 2015) where faulty seals are a key contributor to methane emissions (Johnson et al., 2015). As such, there is a significant need for a robust technology that could provide an early indication of an unexpected emission. Equally important, the technology needs to be able to account for biogenic versus anthropogenic sources of methane. One means of indirectly making this determination, is to leverage optical technologies that can autonomously pinpoint the source of such leaks. This presentation discusses recent work funded by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), focused on the development of an innovative remote sensing technology that can reliably and autonomously detect fugitive methane emissions in near real-time, using computer vision and deep learning. The technology called the Smart Methane Leak Detection (SLED/M) system was initially developed to monitor facilities such as compressor stations in a stationary, pan-tilt-zoom configuration. The system has recently been adapted to monitor facilities from an unmanned aerial system (UAS). The speed and maneuverability of UAS platforms are attractive to leak detection and repair program operators, but introduce several challenges. Many existing methane detection algorithms rely on mostly static backgrounds becoming unusable with motion. In addition, top-down views of fugitive methane emissions present differently in Optical Gas Imagers (OGI) compared to looking across the plume. Our work has focused on overcoming these challenges, enhancing the operators ability to detect methane emissions, and pinpoint their sources. Another recent adaptation to SLED/M is the ability to quantify methane emissions using passive sensors (OGI, thermal camera), environmental conditions, plume modeling, and deep learning. SLED/M advances the state-of-the-art for methane emission detection and quantification by focusing on three key critical criteria for effective methane emission mitigation: (1) autonomy (no need for a human to be in the loop), (2) high reliability (low false alarm rates), and (3) real-time performance. Results from this work will be presented.

03 NATURAL GAS↗

Innovative, Versatile and Cost-Effective Solid Oxide Fuel Cell Stack Concept

This report summarizes the work performed for the U. S. Department of Energy/National Energy Technology Laboratory (DOE/NETL) under Cooperative Agreement DE-FE0026211 entitled “Innovative, Versatile and Cost-Effective Solid Oxide Fuel Cell Stack Concept”. The overall objective of this project was to develop and evaluate a solid oxide fuel cell (SOFC) stack configuration based on a novel prime-surface interconnect design for a broad range of power generation applications. The prime-surface is a one-piece metallic interconnect that incorporates both fuel and oxidant flow fields with peaks on one side of the interconnect serving as flow channels (valleys) on the other side. (One example is the egg-carton shaped interconnect design.) This stack technology has several attractive features including reduced stack weight and volume, decreased performance losses in stacking, improved sealing, versatility in incorporation of different types of cell construction (thin-film cells or sintered cells) and flexibility in gas flow configuration (cross-flow, co-flow or counter-flow). These features lead to lower cost, better performance, and enhanced reliability for the stack. The R&D work of this project focused on demonstrating fabrication, operability and cost effectiveness of the stack design and was conducted by University of California, San Diego (UCSD) in conjunction with OxEon Energy (OxEon). The key technical activities of this project involved prime-surface interconnect design and fabrication development; supported thin-film cell structure development; stack development; stack operation demonstration; and stack cost assessment. The results of these activities are summarized in this report.

30 DIRECT ENERGY CONVERSION↗

Review and Summary of Oxide Thickness Data for Aluminum-Clad Spent Nuclear Fuel

The U.S. Department of Energy (DOE) owns a large inventory of aluminum-clad spent nuclear fuel (ASNF) in interim storage pending ultimate disposition, with more being generated by currently operating research reactors. Dry storage in sealed DOE Standard Canisters is being investigated as an approach for long-term interim storage and/or disposition in a repository for ASNF. A primary challenge for ASNF storage is the presence of aluminum (oxy)hydroxide layers formed on the cladding surfaces during water exposure in the reactor and in wet storage, which forms a reservoir of chemisorbed water not readily removed at low (<100°C) drying temperatures. Free, physisorbed, and chemisorbed water are all susceptible to radiolytic breakdown under irradiation and can release hydrogen gas. Identifying the likely range of (oxy)hydroxide loadings on ASNF that may be placed in dry storage will help to ensure that the impact of the (oxy)hydroxide is adequately accounted for while avoiding over conservatism and enable mitigation strategies to be implemented where needed. The current report summarizes information on (oxy)hydroxide thicknesses and characteristics from the literature and from recent measurements taken in the present research campaign. In general, corrosion studies have indicated that the corrosion and oxide buildup on aluminum are affected by numerous conditions, including pH, temperature and heat flux, coolant flowrates, irradiation (in-reactor vs. unirradiated tests), duration of water exposure, and the amount of oxide already on the surface. Some of these factors are interrelated (e.g., the local temperature, heat flux, and coolant flowrate). Observations of the impact of irradiation (in-reactor versus ex-reactor measurements) on corrosion and oxide thickness are mixed, but multiple studies indicate that there is a significant difference between in-reactor and ex-reactor corrosion kinetics, even when other operating conditions such as pH, flowrate, heat flux, etc., simulate those in a reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗