Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Pancreatic Cancer Tumor Size on CT Scan Versus Pathologic Specimen: Implications for Radiation Treatment Planning

Purpose: Pancreatic cancer primary tumor size measurements are often discordant between computed tomography (CT) and pathologic specimen after resection. Dimensions of the primary tumor are increasingly relevant in an era of highly conformal radiotherapy. Methods and Materials: We retrospectively evaluated 97 consecutive patients with resected pancreatic cancer at two Boston hospitals. All patients had CT scans before surgical resection. Primary endpoints were maximum dimension (in millimeters) of the primary tumor in any direction as reported by the radiologist on CT and by the pathologist for the resected gross fresh specimen. Endoscopic ultrasound (EUS) findings were analyzed if available. Results: Of the patients, 87 (90%) had preoperative CT scans available for review and 46 (47%) had EUS. Among proximal tumors (n = 69), 40 (58%) had pathologic duodenal invasion, which was seen on CT in only 3 cases. The pathologic tumor size was a median of 7 mm larger compared with CT size for the same patient (range, -15 to 43 mm; p < 0.0001), with 73 patients (84%) having a primary tumor larger on pathology than CT. Endoscopic ultrasound was somewhat more accurate, with pathologic tumor size being a median of only 5 mm larger compared with EUS size (range, -15 to 35 mm; p = 0.0003). Conclusions: Computed tomography scans significantly under-represent pancreatic cancer tumor size compared with pathologic specimens in resectable cases. We propose a clinical target volume expansion formula for the primary tumor based on our data. The high rate of pathologic duodenal invasion suggests a risk of duodenal undercoverage with highly conformal radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simple correction for the sample shape and radial offset effects on SQUID magnetometers: Magnetic measurements on Ln{sub 2}O{sub 3} (Ln=Gd, Dy, Er) standards

An increased focus on magnetic measurements of oriented single crystals, thin films, and magnetically dilute systems has led to a demand for the measurement of weak magnetic moments. This level of sensitivity and precision can be achieved on SQUID magnetometers by decreasing the size of the detection coils. However, the smaller detection coils can amplify two errors in the magnitude of the measured moment, the sample shape and radial offset effects, which were small and typically unaccounted for on previous magnetometers. We report a simple method to determine the radial offset of a sample by taking advantage of the two basic scan modes, DC and lock-in, typically used on magnetometers. This technique allows for the correction of the sample shape and radial offset effects in order to obtain the true moment of a sample. To show the efficacy of this technique, we report the magnetic properties of Ln{sub 2}O{sub 3} (Ln=Gd, Dy, Er). - Graphical abstract: Correction for the sample shape and radial offset effects on SQUID magnetometers using a combination of DC and VSM scan data. - Highlights: • Sample shape and radial offset effects alter the moment measured by magnetometers. • We present a simple method to correct for these sample effects on magnetometers. • We measure magnetic susceptibilities of Ln{sub 2}O{sub 3} to show the efficacy of this method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-SPS-03: Direct Measurement of Organ Doses Resulting From Head and Cervical Spine Trauma CT Protocols

Purpose: This retrospective study analyzes the exposure history of emergency department (ED) patients undergoing head and cervical spine trauma computed tomography (CT) studies. This study investigated dose levels received by trauma patients and addressed any potential concerns regarding radiation dose issues. Methods: Under proper IRB approval, a cohort of 300 trauma cases of head and cervical spine trauma CT scans received in the ED was studied. The radiological image viewing software of the hospital was used to view patient images and image data. The following parameters were extracted: the imaging history of patients, the reported dose metrics from the scanner including the volumetric CT Dose Index (CTDIvol) and Dose Length Product (DLP). A postmortem subject was scanned using the same scan techniques utilized in a standard clinical head and cervical spine trauma CT protocol with 120 kVp and 280 mAs. The CTDIvol was recorded for the subject and the organ doses were measured using optically stimulated luminescent (OSL) dosimeters. Typical organ doses to the brain, thyroid, lens, salivary glands, and skin, based on the cadaver studies, were then calculated and reported for the cohort. Results: The CTDIvol reported by the CT scanner was 25.5 mGy for the postmortem subject. The average CTDIvol from the patient cohort was 34.1 mGy. From these metrics, typical average organ doses in mGy were found to be: Brain (44.57), Thyroid (33.40), Lens (82.45), Salivary Glands (61.29), Skin (47.50). The imaging history of the cohort showed that on average trauma patients received 26.1 scans over a lifetime. Conclusion: The average number of scans received on average by trauma ED patients shows that radiation doses in trauma patients may be a concern. Available dose tracking software would be helpful to track doses in trauma ED patients, highlighting the importance of minimizing unnecessary scans and keeping doses ALARA.

60 APPLIED LIFE SCIENCES↗

Enhanced Stability of Lithium Metal Anode by using a 3D Porous Nickel Substrate

Lithium (Li) metal is considered the “holy grail” anode for high energy density batteries, but its applications in rechargeable Li metal batteries are still hindered by the formation of Li dendrites and low Coulombic efficiency for Li plating/stripping. An effective strategy to stabilize Li metal is by embedding Li metal anode in a three-dimensional (3D) current collector. Here, a highly porous 3D Ni substrate is reported to effectively stabilize Li metal anode. Using galvanostatic intermittent titration technique combined with scanning electron microscopy, the underlying mechanism on the improved stability of Li metal anode is revealed. It is clearly demonstrated that the use of porous 3D Ni substrate can effectively suppress the formation of “dead” Li and forms a dense surface layer, whereas a porous “dead” Li layer is accumulated on the 2D Li metal which eventually leads to mass transport limitations. X-ray photoelectron spectroscopy results further revealed the compositional differences in the solid-electrolyte interphase layer formed on the Li metal embedded in porous 3D Ni substrate and the 2D copper substrate.

Yu, Lu↗

Exploiting regulatory heterogeneity to systematically identify enhancers with high accuracy

Identifying functional enhancer elements in metazoan systems is a major challenge. Large-scale validation of enhancers predicted by ENCODE reveal false-positive rates of at least 70%. We used the pregrastrula-patterning network of Drosophila melanogaster to demonstrate that loss in accuracy in held-out data results from heterogeneity of functional signatures in enhancer elements. We show that at least two classes of enhancers are active during early Drosophila embryogenesis and that by focusing on a single, relatively homogeneous class of elements, greater than 98% prediction accuracy can be achieved in a balanced, completely held-out test set. The class of well-predicted elements is composed predominantly of enhancers driving multistage segmentation patterns, which we designate segmentation driving enhancers (SDE). Prediction is driven by the DNA occupancy of early developmental transcription factors, with almost no additional power derived from histone modifications. We further show that improved accuracy is not a property of a particular prediction method: after conditioning on the SDE set, naïve Bayes and logistic regression perform as well as more sophisticated tools. Applying this method to a genome-wide scan, we predict 1,640 SDEs that cover 1.6% of the genome. An analysis of 32 SDEs using whole-mount embryonic imaging of stably integrated reporter constructs chosen throughout our prediction rank-list showed >90% drove expression patterns. We achieved 86.7% precision on a genome-wide scan, with an estimated recall of at least 98%, indicating high accuracy and completeness in annotating this class of functional elements.

54 ENVIRONMENTAL SCIENCES↗

Portland cement paste behaviour under gamma radiation field in geological repository - 15272

The Radioactive Waste Management Laboratory at the Nuclear and Energy Research Institute in Sao Paulo, Brazil (IPEN-CNEN-SP), is developing the concept of a repository for disposition of disused sealed radioactive sources in a deep borehole in which cement paste is intended to be used as a backfill between the steel casing and the geological formation around the borehole. The cement paste is intended to function as structural material, a blockage against the transport of water between the different strata of the geological setting, and as an additional barrier against the migration of radionuclides. The assessment of the cement paste behaviour in long term is necessary to increase the confidence that the material will perform as required during the service life of the facility. Under radiation, pore water present in cement paste suffers radiolysis and some products can be highly reactive, as electrons and hydroxyl radicals and hydrogen peroxide. These radiolysis products will interact with cement paste and its hydration products, forming a wide range of compounds. Previous work focused on assessing the synergic effects of radiation and environmental conditions, like higher temperature and aggressive groundwater chemicals, on cement paste. Examination of samples detected small differences in mineralogy and microstructure. However, the radiation dose to which samples were exposed (400 kGy) was only a fraction of the expected accumulated dose in cement paste until complete decay of some sealed sources in the repository. Therefore, several thousand kilo-grays must be tested the possibility of radiation to alter cement mineralogy and, as a consequence, its durability The objective of this research is to evaluate the changes in mineralogy and microstructure of irradiated cement paste specimens, in an attempt to establish a relationship between irradiation and durability. Cubic Portland cement specimens were casted and exposed to the gamma radiation of a 60 Co multipurpose irradiator, at IPEN-CNEN/SP. The effects of doses between 1000 kGy and 4000 kGy are evaluated by X-Ray Diffraction, Scanning Electron Microscopy, X-ray micro tomography, neutrongraphy and neutron scattering. This report presents the changes in cement paste mineralogy when samples are examined by XRD. Results indicate that durability can be affected because of the observed changes. Results are expected to indicate the induced changes in cement paste under high radiation doses and to provide hints on its behaviour in the long-term and service-life. The results can be used in safety analysis for deep geological repositories that use cement based materials as engineered barriers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Polyvinyl Alcohol (PVA)–Azadirachta indica (Neem) Nanofibrous Mat for Biomedical Application: Formation and Characterization

The present study provides credence to the formation of polyvinyl alcohol (PVA)–Azadirachta indica (neem) nanofibrous mat (PNNM) under optimum processing conditions of electrospinning technique from a mixer of PVA and neem extract to utilize the inherent medicinal properties of this herb for biomedical application. The bonding behavior, orientation of fibers, thermal behavior, and moisture management properties were evaluated by Fourier transforms infrared spectroscopy (FTIR), scanning electron microscopy (SEM), thermo gravimetric analysis (TGA) and moisture management tester (MMT) reports respectively. The antibacterial activity of the developed sample at the maximum mixing ratio of neem extract (80%) was tested against Gram-positive (S. aureus) bacteria using agar disc diffusion method. The results reveal that the prepared nanofibrous mat exhibited better thermal and moisture management properties in comparison with PVA nanofiber alone. The formation of smooth fibers was confirmed by SEM images having average diameter of 185 nm under 5k, 10k and 15k magnifications. The characteristic peaks of PVA and neem constituents in FTIR spectra of the developed mat confirmed the presence of both components. Bacterial resistance was reached up to 20 mm due to the antibacterial constituents of neem extract. Thus the developed mat could be used as a biocompatible and bio based in biomedical applications. Graphic Abstract: .

36 MATERIALS SCIENCE↗

Measurement of the e^+e^-\to b\bar{b} cross section between \SqrtS=10.54 and 11.20 \gev

We report e{sup +}e{sup -} {yields} b{bar b} cross section measurements by the BABAR experiment performed during an energy scan in the range of 10.54 to 11.20 GeV at the PEP-II e{sup +}e{sup -} collider. A total relative error of about 5% is reached in more than three hundred center-of-mass energy steps, separated by about 5MeV. These measurements can be used to derive precise information on the parameters of the {Upsilon}(10860) and {Upsilon}(11020) resonances. In particular we show that their widths may be smaller than previously measured.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synthesis and Structural Stability of Ti2GeC

Mn+1AXn compounds have gathered huge momentum because of its exciting properties. In this paper we report the synthesis of ternary layered ceramic Cr2GeC, a 211 Mn+1AXn compound by hot-pressing. Scanning electron microscopy and X-ray diffraction have been employed to characterize the new synthesized phase. High-pressure compressibility of Cr2GeC were measured using diamond anvil cell and synchrotron radiation at room temperature up to 48 GPa. No phase transformation was observed in the experimental pressure range. The bulk modulus of Cr2GeC calculated using the Birch-Murnaghan equation of state is 169 {+-} 3 GPa, with K? = 3.05 {+-} 0.15.

43 PARTICLE ACCELERATORS↗

Exposure Evaluation for Benzene, Lead and Noise in Vehicle and Equipment Repair Shops

An exposure assessment was performed at the equipment and vehicle maintenance repair shops operating at the U. S. Department of Energy Hanford site, in Richland, Washington. The maintenance shops repair and maintain vehicles and equipment used in support of the Hanford cleanup mission. There are three general mechanic shops and one auto body repair shop. The mechanics work on heavy equipment used in construction, cranes, commercial motor vehicles, passenger-type vehicles in addition to air compressors, generators, and farm equipment. Services include part fabrication, installation of equipment, repair and maintenance work in the engine compartment, and tire and brake services. Work performed at the auto body shop includes painting and surface preparation which involves applying body filler and sanding. 8-hour time-weighted-average samples were collected for benzene and noise exposure and task-based samples were collected for lead dust work activities involving painted metal surfaces. Benzene samples were obtained using 3M™ 3520 sampling badges and were analyzed for additional volatile organic compounds. These compounds were selected based on material safety data sheet information for the aerosol products used by the mechanics for each day of sampling. The compounds included acetone, ethyl ether, toluene, xylene, VM&P naphtha, methyl ethyl ketone, and trichloroethylene. Laboratory data for benzene, VM&P naphtha, methyl ethyl ketone and trichloroethylene were all below the reporting detection limit. Airborne concentrations for acetone, ethyl ether, toluene and xylene were all less than 10% of their occupational exposure limit. The task-based samples obtained for lead dusts were submitted for a metal scan analysis to identify other metals that might be present. Laboratory results for lead dusts were all below the reporting detection limit and airborne concentration for the other metals observed in the samples were less than 10% of the occupational exposure limit. Noise dosimetry sampling was performed on a random basis and was representative of the different work activities within the four shops. Twenty three percent of the noise samples exceeded the occupational exposure limit of 85 decibels for an 8-hour time-weightedaverage. Work activities where noise levels were higher included use of impact wrenches and grinding wheels.

54 ENVIRONMENTAL SCIENCES↗

High-throughput, combinatorial synthesis of multimetallic nanoclusters

Significance Multielement nanomaterials hold great promise for various applications due to their widely tunable surface chemistry, yet it remains challenging to efficiently study this multidimensional space. Conventional approaches are typically slow and depend on serendipity, while a robust and general synthesis is still lacking among increasingly complex compositions. We report a high-throughput technique for combinatorial compositional design (formulation in solution phases) and rapid synthesis (within seconds) of ultrafine multimetallic nanoclusters with a homogeneous alloy structure. We synthesized and screened the PtPdRhRuIrFeCoNi compositional space using scanning droplet cell electrochemistry, with two promising catalysts quickly identified and further verified in a rotating disk setup. The reported high-throughput approach establishes a facile and reliable pipeline to significantly accelerate material discovery in multimetallic nanomaterials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Absolute intensity measurements of the CO2 bands 401-III /backward arrow/ 000 and 411-III /backward arrow/ 010

The absolute intensities of the studied transitions of CO2 have been measured from spectra obtained under high resolution. Vibration-rotation line intensities and integrated band intensities are reported. The studied bands are characterized by origins at 7593.5 and 7584 cm to the minus 1. Spectra were obtained by an Ames' 25-m base path White-type absorption cell equipped with silver-coated mirrors together with a 5-m focal length Czerny-Turner scanning spectrometer. The procedures for calculating the widths and intensities are explained, and uncertainty limits of the reported values are considered.

Valero, F. P. J.↗

North Slope of Alaska XSAPR b1 Data Processing Report: May 2025-April 2026

The U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) User Facility operates an X-band Scanning ARM Precipitation Radar (XSAPR) at the North Slope of Alaska (NSA) atmospheric observatory in Utqiaġvik. This radar provides year-round dual-polarization measurements of snow and ice in an arctic environment. Over the past few years, there has been greater focus on the NSA XSAPR, and recent efforts by ARM staff have resulted in quality-controlled, b-level data (Rocque et al. 2026b). This report outlines the processing of the second set of b-level data released for this radar from May 2025 through April 2026 following similar methods from Rocque et al. (2026b).

54 ENVIRONMENTAL SCIENCES↗

Thematic Mapper. Volume 1: Calibration report flight model, LANDSAT 5

The calibration of the Flight 1 Model Thematic Mapper is discussed. Spectral response, scan profile, coherent noise, line spread profiles and white light leaks, square wave response, radiometric calibration, and commands and telemetry are specifically addressed.

Cooley, R. C.↗

Terrestrial laser scanning data (Levels 0 and 1) for Pasoh, Malaysia, Sep 2024

This data package contains data from terrestrial laser scanning (TLS) at the Pasoh Forest Reserve, Malaysia. The Pasoh Forest Reserve is a facility of the Forest Research Institute Malaysia, and contains evergreen lowland dipterocarp forest. The Next-Generation Ecosystem Experiments Tropics (NGEE-Tropics) study areas at Pasoh were established to study how different species respond to climatic variation and soil water availability. Two study areas were chosen representing different topography and species. The TLS data archived here were collected to provide detailed, three-dimensional information about forest structure. Specifically, data were collected to allow tree-level characterization of woody structure and leaf area for 12 focal trees with FloraPulse and sap flux sensors, facilitating estimation of woody biomass and leaf area to allow upscaling of water content and transpiration data to the tree-level. Scan positions were not selected to provide consistent data for non-focal trees with the study areas. This data package contains the following data: - High-level files document further details of the campaign and data package: 1_CampaignSummary.csv provides details about the campaign and study site, 2_ScanAreasDetail.csv provides details about each separate scan area (groups of scans post-processed into a single point cloud), 3_TerrestrialLidarSensor.csv provides further technical details about the Riegl VZ-400i TLS sensor, TLS_CSV_dd.csv is a CSV Data Dictionary providing information about the fields in CSV files following the ESS-DIVE CSV File Formatting Guidelines Reporting Format, TLS_flmd.csv is a File Level Metadata file providing information about each file in the data package following the ESS-DIVE File Level Metadata Reporting Format, and README.txt is a text file describing the overall project and file structure. - Level 0 data are the raw data (.PROJ folders) as recorded by the Riegl VZ-400i TLS instrument before scan co-registration and post-processing with the Riegl's proprietary RiSCAN PRO software, which requires a license. - Level 1 data contain post-processed, co-registered data from each scan area. The "PointClouds" folder for each scan area contains a .las file with 1 cm resolution point cloud data exported from RiSCAN PRO. These are the main files likely to be of interest to most users and can be further processed with any software capable of manipulating .las files (e.g. Python, R CloudCompare). The "Project Information" folder contains log files from post-processing in RiSCAN PRO that may be of interest to users who want to see detailed records of post-processing, including all PDF reports generated by RiSCAN PRO. The "ScanPositions" folder contains information about the final position of all TLS scans, after post-processing, in multiple formats. The file ScanPositions_*.csv provides final geo-referenced scan positions, and the file SOP_backup_*.csv can be used in RiSCAN PRO to restore the co-registered scan positions if users wish to re-process raw data (Level 0 .PROJ folders) with RiSCAN PRO software (e.g., subsample to a different resolution, exclude a certain scan position, or apply different filters on reflectance or deviation values) without redoing time-consuming co-registration steps.

54 ENVIRONMENTAL SCIENCES↗

Terrestrial laser scanning data (Levels 0 and 1) from Urban Biogeochemistry Pilot Project sites, Knoxville, Tennessee, Jul 2024 - Jul 2025

This data package contains data from terrestrial laser scanning (TLS) at five urban park sites in Knoxville, Tennessee, USA. All parks include open-grown and/or closed-canopy trees and mixed nearby land use. These study sites were established as part of the Urban Biogeochemistry Pilot Project, which has an overall goal of better understanding how hydrobiogeochemical cycling is altered within the human environment. These five sites represent a gradient of urbanization, and were instrumented to understand hydrological and biogeochemical cycling (e.g., soil moisture, soil physical properties and biogeochemistry, tree transpiration, species type). The TLS data archived here were collected to provide detailed, three-dimensional information about forest structure. Specifically, data were collected to allow tree- and stand-level characterization of woody structure and leaf area. TLS scans were placed to capture the area around trees with sap flow sensors, and as much of a 50 m radius area around the meteorological station as possible given site property limits. Derived products will allow upscaling of water content and transpiration data. This data package contains the following data: - High-level files document further details of the campaign and data package: 1_CampaignSummary.csv provides details about the campaign and study site, 2_ScanAreasDetail.csv provides details about each separate scan area (groups of scans post-processed into a single point cloud), 3_TerrestrialLidarSensor.csv provides further technical details about the Riegl VZ-400i TLS sensor, TLS_CSV_dd.csv is a CSV Data Dictionary providing information about the fields in CSV files following the ESS-DIVE CSV File Formatting Guidelines Reporting Format, TLS_flmd.csv is a File Level Metadata file providing information about each file in the data package following the ESS-DIVE File Level Metadata Reporting Format, and README.txt is a text file describing the overall project and file structure. - Level 0 data are the raw data (.PROJ folders) as recorded by the Riegl VZ-400i TLS instrument before scan co-registration and post-processing with the Riegl's proprietary RiSCAN PRO software, which requires a license. - Level 1 data contain post-processed, co-registered data from each scan area. The "PointClouds" folder for each scan area contains a .las file with 1 cm resolution point cloud data exported from RiSCAN PRO. These are the main files likely to be of interest to most users and can be further processed with any software capable of manipulating .las files (e.g. Python, R CloudCompare). The "Project Information" folder contains log files from post-processing in RiSCAN PRO that may be of interest to users who want to see detailed records of post-processing, including all PDF reports generated by RiSCAN PRO. The "ScanPositions" folder contains information about the final position of all TLS scans, after post-processing, in multiple formats. The file ScanPositions_*.csv provides final geo-referenced scan positions, and the file SOP_backup_*.csv can be used in RiSCAN PRO to restore the co-registered scan positions if users wish to re-process raw data (Level 0 .PROJ folders) with RiSCAN PRO software (e.g., subsample to a different resolution, exclude a certain scan position, or apply different filters on reflectance or deviation values) without redoing time-consuming co-registration steps.

54 ENVIRONMENTAL SCIENCES↗

Channel Scaling Dependent Photoresponse of Copper-Based Flexible Photodetectors Fabricated Using Laser-Induced Oxidation

Copper (Cu) oxide compounds (Cu x O), which include cupric (CuO) and cuprous (Cu 2 O) oxide, have been recognized as a promising p-channel material with useful photovoltaic properties and superior thermal conductivity. Typically, deposition methods or thermal oxidation can be used to obtain Cu x O. However, these processes are difficult to apply to flexible substrates because plastics have a comparatively low glass transition temperature. Also, additional patterning steps are needed to fabricate applications. In this work, we fabricated a metal–semiconductor–metal photodetector using laser-induced oxidation of thin Cu films under ambient conditions. Raman spectroscopy, scanning electron microscopy–energy-dispersive X-ray spectroscopy, and atomic force microscopy were used to study the composition and morphology of our devices. Moreover, the photoresponse of this device is reported herein. We performed an in-depth analysis of the relationship between the channel size and number of carriers using scanning photocurrent microscopy. The carrier transport behaviors were identified; the photocurrent decreased as the length and width of the channel increased. Furthermore, we verified the suitability of the device as a flexible photodetector using a variety of bending tests. Our in-depth analysis of this Cu-based flexible photodetector could play an important role in understanding the mechanisms of other flexible photovoltaic applications.

36 MATERIALS SCIENCE↗