Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Apparatus and method for assembling a pumping tube into an air maintenance tire sidewall groove

Apparatus and method of assembling an elongate air pumping tube into an elongate tire sidewall groove includes engaging the tire sidewall outward surface with an impact wheel at an impact location proximally adjacent and above the elongate groove as the tire is rotated. The groove is thereby spread segment-by-segment for segment-by-segment synchronous insertion of the tube into the groove. The groove is closed segment-by-segment as each spread segment is returned to its original narrower dimension utilizing elastomeric material composition properties of the tire sidewall.

42 ENGINEERING↗

SEASONAL PERFORMANCE SIMULATION OF A GAS-FIRED CHEMISORPTION HEAT PUMP FOR RESIDENTIAL HEATING IN COLD CLIMATE

The gas-fired chemisorption heat pump (CSHP) is a promising technology for high-efficiency cold-climate residential heating. The CSHP utilizes the heat of reversible chemical reactions between sorbent and refrigerant to extract heat from cold ambient and supply high-temperature heat to the indoors. The efficiency of CSHP depends on the ambient and heat rejection temperatures. This study evaluates the seasonal performance of a CSHP by first develop a dynamic system model to generate a performance map for various ambient and heat-supply temperatures; then the bin method is used to evaluate the CSHP seasonal performance in two cold-climate locations for space and water heating.

Yang, Zhiyao↗

Heat-pump driven desiccant regeneration

Disclosed herein are systems and processes to thermally regenerate and re-concentrate a liquid desiccant (absorbent) with an electrically driven heat pump. The regeneration and re-concentration may be performed in a cost and energy efficient manner.

Woods, Jason David↗

Use of Systems Engineering in Repurposing Coal-Fired Power Plants with Malta Pumped Thermal Energy Storage System

he electric sector across North America is facing a transition. Both economics and policy decisions have pointed towards a broad retirement of fossil assets across markets. Owners are facing the problem of how to evolve the base of the electric sector from fossil asset to greener alternative. Coal-fired power plants built the modern electricity grid. Their rotating machinery are the beating heart of the grid, providing essential resiliency and reliability services. Power plant retirements are disruptive to plant workforces and cause outsized impacts on surrounding communities. The transition from thermal power plants that use rotating machinery to generate electricity (e.g., coal- and gas-fired plants) to variable, inverter-based generation (e.g., solar and wind) is affecting the reliability of the electric grid. Grid operators and national regulators have issued warnings about known and anticipated risk. In 2021, Malta Inc. was awarded a Department of Energy (DOE) grant to study how to integrate a Malta 100MW Pumped Heat Energy Storage (PHES) system with a retiring coal-fired power plant to meet emissions requirements, retain plant workforces, preserve communities, and maintain grid reliability. This presentation provides a summary of this study, focusing on how systems engineering approach was used to arrive at a proposed design concept that met multiple objectives and requirements. There will be three main parts for this presentation. The first part of the presentation will focus on how different systems engineering was applied for this work. In particular, the following areas: stakeholder engagement, site selection process, developing requirements and use cases for the integrated system, defining the system and its boundary, coming up with different system architecture/option, performing a techno-economic analysis to compare the different options and down selection of the preferred option, will be discusses. For these areas, discussion on the decisions on how much breadth and depth to go into each area will be provided. These discussions provide good insights into how to apply systems engineering. The second part of the presentation will provide a deeper dive into the two recommended integration options that repurpose coal-fired power plants with Malta PHES system. The comparison of the two options and general guidance of how to choose an option will be provided. This is particularly useful for utilities who are facing coal-plant retirements. The two options will be compared based on its performance (such as power output, efficiency), complexity, and cost. The social impact on local communities of the two options will also be discussed. The final part of the presentation will discuss the impact that this work has had, including Malta Inc. being invited to the White House to discuss progress and outcomes of this work with the Interagency Working Group on Coal and Power Plant Communities and Economic Revitalization. In summary, this presentation aims to provide a showcase of how sy

25 ENERGY STORAGE↗

Large Scale Pumped Storage to Support Renewable Deployment; PSH Resource Assessment and Complementary Analysis for Alaska

The State of Alaska has a rather unique electric power system, as it has two larger transmission grids (Railbelt and Southeast Alaska) and over 150 islanded stand-alone power systems that are serving remote rural communities. In 2010, the Alaska legislature enacted a non-binding goal for 50% of renewable electricity generation by 2025. With the expected increase in wind and solar generation in the future, the role of energy storage becomes increasingly important. Considering the specific power system characteristics in Alaska, energy storage technologies that can supply electricity over an extended period of time, such as pumped storage hydropower (PSH), may play a key role in enabling the reliability and resiliency of both integrated and rural power systems. The overarching objective of the subject study of this presentation is to investigate the prospects and opportunities for PSH in Alaska.

Alaska↗

Modeling and Analysing the Impact of Heat Pump Water Heaters on Distribution Systems Using GridLAB-D

With the constant increase in energy demand, finding ways to reduce peak load and the energy-costs factors has become more imperative. Domestic water heating showcases a significant opportunity for such applications. Water heating is the second-highest energy consumer in the residential sector across the United States. Electric Water Heaters (EWHs), in particular, constitute nearly 43% of American household water heating energy consumption. Heat Pump Water Heater (HPWH), on the other hand, are an advanced water heating technology that has recently emerged in the United States residential market. The objectives of this work are to develop a HPWH model and build a case study that evaluates various penetration levels of HPWH in providing reduced peak load and cost-effective energy savings for both utilities and customers. The HPWH model was developed and integrated within the GridLAB-D simulation environment. The model behavior was then validated against a real HPWH unit at Portland State University (PSU). The case studies incorporated five HPWH penetration levels, ranging from 20% to 100%. In each case, EWHs were replaced with HPWHs. The results showed that a high penetration level of HPWHs can reduce the energy consumption on a distribution system to 38%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Modeling of a Thermoelectric Heat Pump Clothes Dryer with Very High Air Flow

Previous research has shown that a clothes dryer heated by thermoelectric (Peltier) heat pumps can be up to 85% more efficient than a conventional electric-resistance dryer. A previous thermoelectric prototype used a conventional dryer’s air flow of 120 ft3/min (0.06 m3/s) and provided about 1,300 W of thermoelectric heating capacity at a heating coefficient of performance (COP) of approximately 1.2. In this work, the performance of a clothes dryer with a very high air flow rate, up to 300 ft3/min (1.14 m3/s), and only 400 W of thermoelectric heating capacity was investigated using a thermohydraulic model. Key aspects of the model were validated experimentally. Results for dry time and efficiency are presented for various air flow and heating rates.

Boudreaux, Philip↗

Reversible pump-turbine installation

The present invention is a reversible pump-turbine installation positioned in a vertical borehole instead of in a conventional underground powerhouse or deep concrete powerhouse. The required plant cavitation coefficient may be achieved by simply boring a vertical borehole to the required depth rather than routing the water flow to and from a deeply buried powerhouse. A pneumatically controlled pressure relief valve may be incorporated into this invention.

Obermeyer, Henry K.↗

Electron subband degeneracy heat pump for cryogenic cooling

An unconventional method of solid-state cryogenic cooling utilizing the electron subband degeneracy of semiconductor heterostructures is discussed in this Letter. The working principle of using the electrons as the working medium to perform cyclic heat pumping under electrostatic subband "expansion" and "compression" is discussed. The calculated base temperature can reach below dilution refrigeration temperatures with the fundamental limit set by electron-phonon interaction. Using an ultra-wide GaAs quantum well as an example, the cooling power per unit volume is estimated to reach $0.85\ \rm \mu W/cm^3$ at $25\ \rm mK$ with a hot-side temperature of $42.5\ \rm mK$, suitable for applications such as quantum computing.

Wang, Chulin↗

Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters

The demand profile management of electric end uses is vital research for utilities and policymakers planning greenhouse gas emission reductions. In this study, detailed laboratory research was conducted on the load shifting potential of 4 grid-connected HPWHs and one electric resistance water heaters (ERWH). The testing applied different CTA-2045 shed and critical peak command designs under three water draw profiles. Highly-controlled laboratory experiments were conducted in Florida. One of the four HPWHs was a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load-up above tank setpoint. A three-hour morning (6 – 9 AM) and four-hour evening curtailment (4 – 8 PM) were defined as the shed or critical peak periods reflecting high-value control periods for utility coincident load for system-wide electric demand reductions. Tests were performed under baseline conditions (no load shift) and under varied load-shifting schemes, including load up and advanced load up, ahead of shed and critical peak commands. Data were collected from December 2020 – February 2022 in the laboratory and compared with field experiments in Florida and the Pacific Northwest. Grid-connected HPWHs were found to reduce peak demand by up to 0.47 kW compared to uncontrolled HPWH units, depending on time of day, control scheme, draw profile, and temperature cluster. The load up strategy demonstrated the ability of all units to utilize heat pump mode for extended periods ahead of peak events. Demand reductions for the HPWHs were much larger when compared with the ERWH— up to 1.64 kW with large hot water draws in winter.

Fenaughty, Karen↗

A proposed methodology to reduce heat pump size with integrated thermal energy storage

Thermal energy storage (TES) offers a unique storage solution wherein heat is stored for later use to thermally condition an application. Heat pumps (HPs) move heat from relatively cold to a relatively hot with an input of work. Integrating TES into a HP system adds a third temperature body, and the HP can be selectively coupled to operate between any two: a constant temperature application, a temporally fluctuating ambient temperature, or a constant temperature TES. Since the HP-TES system enables operation under different conditions depending on the pair of temperature bodies, changes in efficiency and capacity can be expected. Thus, TES can shift HP operation to more favorable conditions to deliver heat to the application. Consequently, TES increases the apparent capacity of the HP which might enable a nominally smaller HP to be used effectively. This paper outlines a method by which TES can reduce the size of a HP without sacrificing heat delivered to the application. The method is demonstrated for a building cooling application which realized a reduction in nominal HP size from 3 tons to 2.4 tons.

Hirschey, Jason↗

Searching for eco-friendly working fluids for an ejector-driven heat pump for domestic water heating

This study searches for refrigerants with low global warming potential (GWP) and zero ozone depletion potential (ODP) for an ejector heat pump water heater (EHPWH). Several criteria are set, and R1336mzz(Z), R601a, R1233zd(E), R1224yd(Z), R1234ze(Z), and R600a are shortlisted. A theoretical model is built to study the performance of EHPWH and the corresponding ejector design at different operating conditions. For the same ejector design, a refrigerant with a high specific heat ratio produces a high entrainment ratio and heating COP. This is because the expansion wave angle in the ejector is small for refrigerants with a high specific heat ratio, allowing more mass flow rate to be entrained. A higher entrainment ratio does not necessarily correlate to a high COP because the saturation curve of the tested refrigerants is not the same. Results show that the heating COP of R601a is the highest, but it is extremely flammable. R1224yd(Z) and R1234ze(Z) are the most candidates for EHPWH when the trade-off between the COP and safety criteria is considered. The results presented in this work could help building an EHPWH using eco-friendly refrigerants.

Mohammed, Ramy H.↗

Performance Analysis of High-Temperature Heat Pumps with Two-Phase Ejectors

A two-phase ejector recovers the energy in the refrigerant cycles’ throttling process, improving the coefficient of performance (COP) of high-temperature heat pumps (HTHPs). This study investigated the effects of the mixing pressure on the performance of two-phase ejectors and ejector-assisted HTHPs. A 1D theoretical model of a two-phase ejector was built to predict the internal fluid dynamics and evaluate ejector performance. A thermodynamic model of an ejector-assisted HTHP was built to evaluate the COP of HTHPs and the volumetric heating capacity of low-global warming potential refrigerants. The results demonstrate that an optimum mixing pressure in a two-phase ejector provides the best performance of a two-phase ejector and ejector-assisted HTHP. The optimum mixing pressure was slightly lower than the evaporation pressure. At this pressure, the two-phase flow in the ejector was subsonic. For ejector-assisted HTHPs using low–global warming potential refrigerants at a sink temperature of 120°C, temperature lift of 40°C, and subcooling of 10°C, a two-phase ejector has an average ejector efficiency of 0.334, and the COP and volumetric heating capacity were improved by 7.2% and 7.3%, respectively.

Wang, Pengtao↗

Electrically pumped vertical cavity laser

Disclosed is an electrically pumped vertical cavity laser structure operating in the mid-infrared region, which has demonstrated room-temperature continuous wave operation. This structure uses an interband cascade gain region, two distributed mirrors, and a low-loss refractive index waveguide. A preferred embodiment includes at least one wafer bonded GaAs-based mirror.

Jayaraman, Vijaysekhar↗

Optically pumped, radio-frequency atomic magnetometry with feedback stabilization

An optically pumped, atomic magnetometer incorporates a feedback system for stabilizing the magnetic bias field and suppressing unwanted background fields. The magnetic bias field is applied to a vapor cell containing host atoms of two different species, each of which resonates at a different Larmor frequency when both are subjected to the same magnetic bias field. One species provides the feedback for stabilizing the bias field, thereby creating a stabilizing magnetometer portion that nulls out the unwanted background fields. The other species provides magnetic field detection or signal reception on a radio communication frequency of interest, thereby creating a signal magnetometer portion that permits detection of the signal at the radio communication frequency.

Schwindt, Peter D. D.↗

Vector measurements using a pulsed, optically pumped atomic magnetometer

An atomic magnetometer, and a method for using same is disclosed. The method for measuring an ambient magnetic field uses an atomic magnetometer that has a probe light beam with a probe axis that probes a polarization vector of an atomic population confined within a vapor cell. The method employs one or more measurement cycles. In each measurement cycle, the polarization vector is prepared in an initial state via an optical pumping pulse. The vapor cell is then subjected to the ambient magnetic field, which results in rotation of the polarization vector by Larmor precession. Within the measurement cycle, at a point in time after the polarization vector has been prepared in the initial state, the ambient magnetic field rotates the direction of the polarization vector, and at least one measurement is made of a projection of the Larmor-rotated polarization vector onto the probe axis during or after application of a magnetic waveform.

Schwindt, Peter↗

Pump-and-Treat Impacts on Aquifer Conditions and the Development of System-Wide Performance Strategies - 20377

The pump-and-treat (P and T) system on the Hanford Site's Central Plateau currently treats multiple contaminants within the 200-ZP-1 operable unit, including nitrate through its biological treatment processes. Although it was initially designed to support the 200-ZP-1 Remedial Action Objectives, the P and T system has evolved in use to address contaminants from other regions of the aquifer as well. The P and T influents are biogeochemically distinct, treating groundwaters with elevated concentrations of cyanide, uranium, technetium-99, and nitrate. Given the varying geochemical signatures from current and potential future sources, operational conditions, and amendments considered for treatment processes, there is a need to identify the impacts that the P and T effluent has on the aquifer, and how the aquifer affects P and T performance. To this end, laboratory efforts have focused on characterizing P and T effluent and its biogeochemical effects on the sediments through a series repacked column experiments. The P and T effluent is rich in particulate matter. A systematic inspection of this particulate matter in the P and T effluent showed significant levels of manganese/iron oxides, calcite crystals, relatively large organic matter molecules, and biomass. Therefore, the column experiments were designed and conducted for four different treatment systems: artificial groundwater, filtered P and T effluent, non-filtered P and T effluent, and chlorinated P and T effluent. Different levels of microbiologically- and geochemically-induced changes in the columns occurred and modified the flow systems. For example, physical filtration occurred in the sediments where the particulate material had accumulated in the top portion of the column. Reactive transport modeling of the laboratory experiments is being carried out so that the reaction network can be extrapolated to the field scale. These simulations will provide predictive evaluations of system performance based on P and T operational changes and aquifer mass loading and capacity estimates. This information can be used to address combined subsurface and operational challenges, such as the need for frequent well redevelopment to maintain injection capacity. This information also provides the technical basis for decisions related to the P and T system operations that support remedy optimization efforts and short- and long-term remedy decisions related to multiple operable units on the Hanford Site Central Plateau. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗