Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plug”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Modeling Heat Transfer and Reaction Kinetics of Biomass in Pyrolysis Feeding Systems

Biomass feedstocks can be used to produce low carbon-intensity chemicals and liquid fuels by displacing fossil-fuel sources. Pyrolysis is the thermal decomposition of biomass in the absence of oxygen and can be used to produce crude biofuels. A typical feeding mechanism for pyrolysis reactors is by lock hopper followed by a horizontal auger feeder. Particle agglomeration and plugging of the auger screw are regularly occurring phenomena that is detrimental to the process since it results in the need for periodic inspection and cleaning. The underlying mechanisms leading to agglomeration and plugging are unclear, but a working hypothesis is that heat from the reactor raises the temperature of the biomass in the feeder to the point at which preliminary decomposition reactions occur and produce "sticky" products. Using principles of heat and mass transfer, we derived one-dimensional differential equations for heat flow from the pyrolysis reactor through the auger feeder. Temperature profiles were solved from the system of one-dimensional differential equations using the shooting method. Subsequently, we used the temperature profiles as a one-way coupling to a reaction model for the biomass in the feeder. Kinetic models were adopted from the literature and used to predict the formation of intermediates, products, char, extractives, and metaplastics as well as phase changes along the auger feeder. Species were identified that correlated with softening of the biomass, causing it to become sticky and plug the feeder. We will discuss the details of this work, our findings, and the direction of future work that includes fully coupled transport and reaction-kinetics simulations.

BIOMASS FUELS↗

Extended Sleeve Products Allow Control and Monitoring of Process Fluid Flows Inside Shielding, Behind Walls and Beneath Floors - 13041

Throughout power generation, delivery and waste remediation, the ability to control process streams in difficult or impossible locations becomes increasingly necessary as the complexity of processes increases. Example applications include radioactive environments, inside concrete installations, buried in dirt, or inside a shielded or insulated pipe. In these situations, it is necessary to implement innovative solutions to tackle such issues as valve maintenance, valve control from remote locations, equipment cleaning in hazardous environments, and flow stream analysis. The Extended Sleeve family of products provides a scalable solution to tackle some of the most challenging applications in hazardous environments which require flow stream control and monitoring. The Extended Sleeve family of products is defined in three groups: Extended Sleeve (ESV), Extended Bonnet (EBV) and Instrument Enclosure (IE). Each of the products provides a variation on the same requirements: to provide access to the internals of a valve, or to monitor the fluid passing through the pipeline through shielding around the process pipe. The shielding can be as simple as a grout filled pipe covering a process pipe or as complex as a concrete deck protecting a room in which the valves and pipes pass through at varying elevations. Extended Sleeves are available between roughly 30 inches and 18 feet of distance between the pipeline centerline and the top of the surface to which it mounts. The Extended Sleeve provides features such as ± 1.5 inches of adjustment between the pipeline and deck location, internal flush capabilities, automatic alignment of the internal components during assembly and integrated actuator mounting pads. The Extended Bonnet is a shorter fixed height version of the Extended Sleeve which has a removable deck flange to facilitate installation through walls, and is delivered fully assembled. The Instrument Enclosure utilizes many of the same components as an Extended Sleeve, yet allows the installation of process monitoring instruments, such as a turbidity meter to be placed in the flow stream. The basis of the design is a valve body, which, rather than having a directly mounted bonnet has lengths of concentric pipe added, which move the bonnet away from the valve body. The pipe is conceptually similar to an oil field well, with the various strings of casing, and tubing installed. Each concentric pipe provides a required function, such as the outermost pipes, the valve sleeve and penetration sleeve, which provide structural support to the deck flange. For plug valve based designs, the next inner pipe provides compression on the environmental seals at the top of the body to bonnet joint, followed by the innermost pipe which provides rotation of the plug, in the same manner as an extended stem. Ball valve ESVs have an additional pipe to provide compressive loading on the stem packing. Due to the availability of standard pipe grades and weights, the product can be configured to fit a wide array of valve sizes, and application lengths, with current designs as short as seven inches and as tall as 18 feet. Central to the design is the requirement for no special tools or downhole tools to remove parts or configure the product. Off the shelf wrenches, sockets or other hand tools are all that is required. Compared to other products historically available, this design offers a lightweight option, which, while not as rigidly stiff, can deflect compliantly under extreme seismic loading, rather than break. Application conditions vary widely, as the base product is 316 and 304 stainless steel, but utilizes 17-4PH, and other allows as needed based on the temperature range and mechanical requirements. Existing designs are installed in applications as hot as 1400 deg. F, at low pressure, and separately in highly radioactive environments. The selection of plug versus ball valve, metal versus soft seats, and the material of the seals and seats is all dependent on the application requirements. The design of the Extended Sleeve family of products provides a platform which solves a variety of accessibility problems associated with controlling process flow streams in remote, hard to reach locations in harsh environments. Installation of the equipment described has shown to allow access to flow streams that otherwise would require exceptional means to access and control. The Extended Sleeve family of products provides a scalable solution to both control and monitor process fluid flow through shielding, walls or floors when direct connection is advantageous. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion test of LWR cladding tubes in high temperature seawater

In the case of cooling system failure in spent fuel pools (SFP) due to station black out and/or loss of coolant accidents, a pool water level must be kept high enough to avoid overheat of spent fuels. Seawater is one of the candidate coolant materials in such emergencies. In the present work, we have studied the corrosion behavior of zirconium alloys in seawater. Tube samples of Zircaloy-2 and -4 claddings were immersed in artificial seawater (3, 10 and 20 wt.%) at high temperature (80 - 85 Celsius degrees). Boric acid was added to the seawater at a corrosion test of Zircaloy-4. Two types of specimens were prepared according to the simulation of circumferential tensile stress. One was a plugged tube specimen, which was pressurized to around fuel rod pressure in a spent fuel pool by argon gas. Another specimen was of C-ring shape, where large circumferential tensile stress was partially induced at the surface. A notch was longitudinally grooved to increase the local tensile stress on some of the C-ring specimens. The specimen surface was observed by a scanning electron microscopy (SEM) after the corrosion test. After the 200 day long corrosion test for the plugged tube specimens without boric acid, Mg(OH){sub 2} deposits were observed on the surface of Zircaloy-2 and -4 specimens whereas Mg(OH){sub 2} was not observed with boric acid because of probably a lower pH. Neither pitting corrosion nor stress corrosion cracking (SCC) was observed on the surface of all plugged tube specimens. Only in the C-ring specimens in 20 wt.% seawater without boric acid and in 3 and 10 wt.% seawater with boric acid, small cracks were observed at the notch. The results of the present work show that Zircaloy-2 and -4 have a high tolerance towards corrosion and SCC in high temperature seawater.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design and testing of a combined neutron and gamma assay system for measuring fissile material in fuel and waste items - 15340

A combined neutron and gamma ray assay system for the measurement of fissile material in both fuel and waste items has been designed, modelled, developed and tested. The purpose of the system is to measure and characterize a wide range of fissile materials including uranium, plutonium, americium and mixed oxide fuel arising from a variety of processes and facilities across the United Kingdom. Dounreay Site Restoration Limited at Dounreay currently stores these items form the United Kingdom Nuclear Decommissioning Authority's un-irradiated fuel inventory. This inventory comprises historic materials from ex-United Kingdom Atomic Energy Authority nuclear fuel projects and experiments together with fast reactor fuel materials and some commercial fuel items as delivered to Dounreay for recovery. The combined assay system has been designed and constructed to support the operation of a fuel processing facility, which will be operated at Dounreay to treat these historic legacy fuel materials, making them suitable for long term storage. Appropriate characterization of the fissile material is required for safety, criticality control and nuclear materials safeguards purposes prior to final disposition. The system consists of both gamma ray and neutron measurement components. The results of a neutron measurement are combined with the gamma ray isotopic ratio measurement results to generate the assay result for the fissile material being characterized. The gamma ray component of the system employs a safeguards quality high purity Germanium detector with electro-mechanical cooling and the measurements of fissile material containers are made in a shielded chamber with a tin and copper graded lining. Containers of fissile material are rotated during the gamma ray measurement and a variable automatic steel collimator aperture mechanism is employed to adjust the measured count rate to control detector dead time. Gamma ray spectra are analysed using the plutonium and uranium isotopic ratio code PC/FRAM. The gamma ray system can also be configured to perform a direct assay of small quantities of uranium bearing material. For this assay measurement a series of cadmium filters can be positioned in front of the detector to reduce the contribution from 59 keV gamma rays from Am-241. In addition to gamma ray isotopic measurements, both active and passive neutron assay is performed by the system. The neutron-measuring component consists of a thick walled cylindrical polyethylene chamber, which provides neutron moderation for 30 one-inch diameter He-3 detector tubes located in re-entrant channels in the polyethylene moderator. Two removable polyethylene-inserts incorporating lower plug assemblies are provided, one with and one without a cadmium lining. Also two top plug units are provided, again one with cadmium and one without a cadmium liner. The Neutron Subsystem can be operated both as a passive and as an active neutron coincidence counter. In both fast and thermal active neutron mode, the neutron component employs two americium-beryllium (Am-Be) alpha-n neutron sources, one positioned in the top and the other in the bottom plug unit. The neutron sources are removed when the counter is operated in passive mode. Passive neutron detection efficiency and active neutron performance has been modelled using the MCNP Monte Carlo computer simulation code as part of the design process. In the absence of fissile samples, operation of the gamma ray component of the system has been tested initially using calibrated Eu-152 and Ba-133 gamma ray sources and the use of archived spectra from fissile material measurements. Initial testing of the neutron system has employed a calibrated Cf-252 spontaneous fission neutron source. Neutron testing has been confirmed using further MCNP simulations. The results of test measurements with the system are presented and compared with the results of MCNP measurement simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ITER Port Interspace Pressure Calculations

The ITER ('the way' in Latin) project in Cadarache, France, will operate the largest tokamak ever built to demonstrate the physical and technical feasibility of nuclear fusion as an energy source. The ITER vacuum vessel is equipped with 50 access ports. Each port has an opening in the bio-shield that communicates with a dedicated port cell. During tokamak operation, the bio-shield opening must be closed with a concrete plug to shield the radiation coming from the plasma. This port plug separates the port cell into a port interspace (between vacuum vessel closure lid and port plug) on the inner side and a port cell on the outer side. This paper presents calculations of pressures and temperatures in the ITER port interspace after a double-ended guillotine break (DEGB) of a pipe in the tokamak cooling water system (TCWS). It is assumed that the DEGB occurs during the worst possible conditions-during water baking operation, with water at 523 K (250 deg. C) and 4.4 MPa. These conditions are more severe than during normal tokamak operation with the water at 398 K (125 deg. C) and 2 MPa. Two computer codes are employed in these calculations: RELAP5-3D Version 4.2.1 to calculate blowdown releases from the pipe break, and MELCOR, Version 1.8.6 to calculate pressures and temperatures in the port interspace. A sensitivity study has been performed to optimize the maximum peak pressure in the port interspace volume of ITER. The optimum case was for a labyrinth area (FL131) of 0.5 m{sup 2} and a relief panel (FL135) kept open after the first cycle. This case keeps the pressure in the port interspace under 150 kPa and the temperatures under 385 K. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the Salt at Wall Thermal Exchanges (SWATH) Experiment

Molten Salt Reactors have attracted increased attention in recent years because of the design and safety possibilities offered by the use of a liquid fuel. The European project SAMOFAR1 (2015-2019) is currently coordinating the research efforts on the Molten Fast Salt Reactor (MSFR) concept in Europe. The MSFR is a fast-spectrum breeder reactor with a large negative power coefficient that can be operated in a Thorium fuel cycle. The fast spectrum allows the reduction of the reprocessing requirements and a better reactor breeding ratio. Other advantages of the MSFR design are the possibility for actinide burning and extending fuel resources, on-line fuel loading and reprocessing and the use of novel passive safety systems such as the fuel salt draining system. The reference MSFR concept is a 3000 MW(th) reactor with three different circuits: the fuel circuit, the intermediate circuit and the power conversion system. The main components of the fuel circuit are the fuel salt which serves as fuel and coolant, the core cavity, the inlet and outlet pipes, the gas injection system (not shown in the figure), the salt-bubble separators, the fuel heat exchangers and the pumps. A lithium fluoride salt has been selected as the fuel matrix. The initial composition (non-irradiated) of the MSFR fuel salt is a mixture of a lithium fluoride, thorium fluoride salts and actinides fluoride (LiF-ThF{sub 4}-{sup 233}UF{sub 4} or LiF-ThF{sub 4}- {sup enr}UF{sub 4}-(Pu-MA)F{sub 3}), with the proportion of LiF fixed at about Development of accurate numerical models for the MSFR can only be accomplished by the use of a multiphysics approach which allows taking into account the coupling between relevant neutronics, thermal hydraulics and thermomechanics phenomena. As it is discussed in the next section, such a reactor model requires further progress on the knowledge of molten salt thermal hydraulics, in particular regarding the accuracy of the fuel salt Computational Fluid Dynamics (CFD) models. The Salt at Wall: Thermal Exchanges (SWATH) experiment is being designed to contribute to this particular point. SWATH is one of the experimental activities of the European H2020 SAMOFAR project and includes both experimental and numerical developments. The main objectives of SWATH are to: (i) Improve molten salt numerical models used for design and safety studies and (ii) Demonstrate the working principles of the cold plug device. The cold plug device is a key safety component of the salt draining system of the MSFR. The cold plug is intended to passively melt during accidental conditions thus allowing the flow of the nuclear fuel from the core cavity to the fuel salt draining tanks by gravity forces. The fuel salt draining tanks are designed to ensure that adequate margins are obtained regarding the fuel cooling capabilities and the reactivity control. The next sections provide an overview of the current challenges in molten salt thermal hydraulics modeling and the SWATH experiment design. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of Radiation Cross-Talk Effects on Biological Dose Rates in Maintenance Areas Inside the ITER Tokamak - Paper 107

The intense plasma neutron source of ITER requires careful consideration of radiation safety during the design of the machine, its operation plan and licensing process. One important issue is that of occupational radiation exposure (ORE) during in-situ maintenance activities inside the cryostat, and particularly in the port inter-space area (PI) where up keeping of port systems should take place (diagnostics, tritium breeding test modules, heating antennas). ITER ports and port plugs (PP) become activated by neutron irradiation during plasma operation; from the subsequent decay and gamma emission of irradiated materials, the so-called shutdown dose rate field (SDR) appears. A project requirement of 100 uSv/h after 12 days exists for the SDR in the PI in order to limit exposure during maintenance and meet ORE regulatory limits. This requirement is particularly challenging for equatorial ports (EP) due to, among others, background neutron radiation and activation from/by neighbouring components (a.k.a. 'cross-talk'), and particularly the lower ports (LP). For a particular port inter-space, the SDR field is a combination of: (i) the gamma dose due to the activation of components local to the PI, typically referring to the PI itself plus the port plug, port duct and bellows, vessel extension and blankets in its vicinity; (ii) the gamma dose due to activation of components far away from the PI, a.k.a. the cross-talk, which typically refers to other ports, cryostat and rest of the vacuum vessel and blankets. The situation is complicated to some extent by the fact that both these components can arise from a combination of irradiation by local neutrons, i.e. those permeating through the vicinity of the port itself, and by cross-talk neutrons, i.e. those permeating via other paths. In simple terms, the so-called 'neutron cross-talk' refers to neutron leakage through other ports and components producing activation, decay gammas and dose locally in the PI of interest, whereas the 'gamma cross-talk' refers to activation and decay gammas in other ports producing dose in the PI from far away. The study reported here focuses on the evaluation of the effect of radiation cross-talk from a torus cryopump (TCP) LP located directly underneath a generic diagnostics equatorial port plug (DEPP) in the equatorial port itself. This is considered the worst case scenario, as the TCP-LP has a large aperture and has to be mostly empty in order to meet TCP pumping requirements. For the reference case and R1, the neutron cross-talk from the LP activating the EP is responsible for 109 uSv/h. In addition, a gamma cross-talk of 51 uSv/h from LP activation has been found. The total cross-talk contribution is therefore responsible for 160 uSv/h of SDR at EP PI. The local SDR contribution, i.e. that from activation of the EP with 'local-only' neutrons, is 166 uSv/h. The total SDR at R1 is 360 uSv/h, including some minor contributions from the UP, lateral EPs, cryostat and bio-shield. The total SDR at R2 is 349 uSv/hr, with a cross-talk contribution of 203 uSv/h. In R2 the gamma cross-talk is more intense, as it is closer to the highly activated TCPH. These results illustrate how the SDR field produced by radiation cross-talk through a TCP-LP is comparable in magnitude with that produced by neutron leakage and activation local to the EP. Shielding options are currently under consideration. Local gamma shielding at the EP PI is found to be effective in reducing gamma cross-talk from the LP and TCPH, and also in reducing the local contribution from the port duct and bellows. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Pushing the Envelope-Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream: Preprint

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

anisotropic envelope↗

Pushing the Envelope—Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

Shrestha, Som↗

High-Level Application Framework for LCLS

A framework for high level accelerator application software is being developed for the Linac Coherent Light Source (LCLS). The framework is based on plug-in technology developed by an open source project, Eclipse. Many existing functionalities provided by Eclipse are available to high-level applications written within this framework. The framework also contains static data storage configuration and dynamic data connectivity. Because the framework is Eclipse-based, it is highly compatible with any other Eclipse plug-ins. The entire infrastructure of the software framework will be presented. Planned applications and plug-ins based on the framework are also presented.

43 PARTICLE ACCELERATORS↗

NREL Reveals Links Among Climate Control, Battery Life, and Electric Vehicle Range (Fact Sheet)

Researchers at the National Renewable Energy Laboratory (NREL) are providing new insights into the relationships between the climate-control systems of plug-in electric vehicles and the distances these vehicles can travel on a single charge. In particular, NREL research has determined that 'preconditioning' a vehicle-achieving a comfortable cabin temperature and preheating or precooling thebattery while the vehicle is still plugged in-can extend its driving range and improve battery life over the long term.

25 ENERGY STORAGE↗

Proposal for a Vehicle Level Test Procedure to Measure Air Conditioning Fuel Use

The air-conditioning (A/C) compressor load significantly impacts the fuel economy of conventional vehicles and the fuel use/range of plug-in hybrid electric vehicles (PHEV). A National Renewable Energy Laboratory (NREL) vehicle performance analysis shows the operation of the air conditioner reduces the charge depletion range of a 40-mile range PHEV from 18% to 30% in a worst case hot environment. Designing for air conditioning electrical loads impacts PHEV and electric vehicle (EV) energy storage system size and cost. While automobile manufacturers have climate control procedures to assess A/C performance, and the U.S. EPA has the SCO3 drive cycle to measure indirect A/C emissions, there is no automotive industry consensus on a vehicle level A/C fuel use test procedure. With increasing attention on A/C fuel use due to increased regulatory activities and the development of PHEVs and EVs, a test procedure is needed to accurately assess the impact of climate control loads. A vehicle thermal soak period is recommended, with solar lamps that meet the SCO3 requirements or an alternative heating method such as portable electric heaters. After soaking, the vehicle is operated over repeated drive cycles or at a constant speed until steady-state cabin air temperature is attained. With this method, the cooldown and steady-state A/C fuel use are measured. This method can be run at either different ambient temperatures to provide data for the GREEN-MAC-LCCP model temperature bins or at a single representative ambient temperature. Vehicles with automatic climate systems are allowed to control as designed, while vehicles with manual climate systems are adjusted to approximate expected climate control settings. An A/C off test is also run for all drive profiles. This procedure measures approximate real-world A/C fuel use and assess the impact of thermal load reduction strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accounting for the Variation of Driver Aggression in the Simulation of Conventional and Advanced Vehicles: Preprint

Hybrid electric vehicles, plug-in hybrid electric vehicles, and battery electric vehicles offer the potential to reduce both oil imports and greenhouse gases, as well as to offer a financial benefit to the driver. However, assessing these potential benefits is complicated by several factors, including the driving habits of the operator. We focus on driver aggression, i.e., the level of acceleration and velocity characteristic of travel, to (1) assess its variation within large, real-world drive datasets, (2) quantify its effect on both vehicle efficiency and economics for multiple vehicle types, (3) compare these results to those of standard drive cycles commonly used in the industry, and (4) create a representative drive cycle for future analyses where standard drive cycles are lacking.

25 ENERGY STORAGE↗

Modeling Framework and Results to Inform Charging Infrastructure Investments

The plug-in electric vehicle (PEV) market is experiencing rapid growth with dozens of battery electric (BEV) and plug-in hybrid electric (PHEV) models already available and billions of dollars being invested by automotive manufacturers in the PEV space. Electric range is increasing thanks to larger and more advanced batteries and significant infrastructure investments are being made to enable higher power fast charging. Costs are falling and PEVs are becoming more competitive with conventional vehicles. Moreover, new technologies such as connectivity and automation hold the promise of enhancing the value proposition of PEVs. This presentation outlines a suite of projects funded by the U.S. Department of Energy's Vehicle Technology Office to conduct assessments of the economic value and charging infrastructure requirements of the evolving PEV market. Individual assessments include national evaluations of PEV economic value (assuming 73M PEVs on the road in 2035), national analysis of charging infrastructure requirements (with community and corridor level resolution), and case studies of PEV ownership in Columbus, OH and Massachusetts.

33 ADVANCED PROPULSION SYSTEMS↗

Electric-Drive Vehicles

Electric-drive vehicles use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. These vehicles can be divided into three categories: Hybrid electric vehicles (HEVs), Plug-in hybrid electric vehicles (PHEVs), All-electric vehicles (EVs). Together, PHEVs and EVs can also be referred to as plug-in electric vehicles (PEVs).

33 ADVANCED PROPULSION SYSTEMS↗

Analysis of the Ion Conversion Mechanisms in the Effluent of Atmospheric Pressure Plasma Jets in Ar with Admixtures of O 2 , H 2 O and Air

Ionic species in atmospheric pressure plasma jets (APPJs) play an important role in plasmasurface and plasma-liquid interactions, nonetheless, they have not received the same attention as their neutral reactive species counterparts. In this work, a molecular beam mass spectrometer (MBMS) was used to characterize the ion compositions in the effluent of an APPJ operating in ambient air for different feed gases including Ar + O 2 , Ar + air and Ar + H 2 O mixtures inspired by gas compositions used for biomedical applications. Changes in compositions of positive and negative ions as a function of nozzle-to-substrate distance along the plasma plume were analyzed and compared with a pseudo-1D plug flow model. Positive and negative ions were detected up to distances of 12 mm from the visible plasma plume tip. The measurements enable to follow the ion conversion pathways in the effluent of the APPJs as a function of distance from the nozzle. The trends in ion yield obtained from a pseudo-1D plug flow model showed generally a good agreement with the experimentally observed trends after addition of ionic reactions to the previously reported reaction set but also some distinctive differences were observed. The dominant positive ions in the far effluent are water ion clusters, the most stable ion for all gas mixtures investigated, while a large variety of negative ions was found for different gas mixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling electric vehicle adoption considering a latent travel pattern construct and charging infrastructure

This paper presents a behavioral model of public, revealed preferences (RP) for various types of electric vehicles (EVs) while accounting for a latent (green) travel pattern construct and charging infrastructure characteristics. Specifically, a two-level nested logit (NL) model is estimated to explain households' fuel type choice among five alternatives and three nests: (1) battery electric vehicles (BEVs); (2) hybrid vehicles including hybrid electric vehicles (HEVs) and plug-in HEVs (PHEVs); and (3) conventional vehicles including gasoline and diesel vehicles. Further, a latent travel pattern construct which captures a week-long number of trips by non-vehicle travel modes as well as daily vehicle and tollway use is estimated in a structural equation setting and subsequently fed into the NL model. Using a recent RP dataset from the California Household Travel Survey, we identify market segments for alternative fuel types based on households' socio-economic characteristics, built environment factors concerning public plug-in EV (PEV) charging infrastructure characteristics, latent and observable travel behavior factors of a household vehicle's principal driver, and vehicle attributes. The results highlight that the number of public PEV charging stations is only significant for households choosing PHEVs and interestingly insignificant in the BEV utility. Furthermore, the sensitivity analysis of the findings reveals that PHEV users are elastic with respect to household vehicle ownership ratio and the latent green travel pattern construct, while BEV users are inelastic to any explanatory variable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy savings and usability of zero-client computing in office settings

This study provides a detailed comparison of the power consumption, usability, and applicability of virtual machines (VMs) - accessed through zero-client devices - and traditional laptop computers in office settings. The study analyzed high-level plug loads across two office spaces, one using traditional laptops, the other using zero clients. In addition, the individual power consumption of four workstations was monitored and compared. Each workstation user switched between using a laptop or zero client for one week and then using the alternate system the second week. Results of the high-level and workstation analysis show that average workstation plug loads are lower for occupants using zero clients. However, this does not include power consumed by the data center managing VMs. This study calculates the affiliated data center power draw of VMs and shows that server-related loads push total zero-client computing energy higher than that of traditional laptops. Finally, a questionnaire was administered to building occupants to determine the appropriateness of zero-client computing for various user groups, with the results indicating that VMs are most appropriate for more basic software functions. The findings of this study suggest that advances in server technology can help improve both the overall efficiency and the usability of zero-client computing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗