Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plasticity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Plastic strain arrangement in copper single crystals in sliding

Deformation of tribologically loaded contact zone is one of the wear mechanisms in spite of the fact that no mass loss may occur during this process. Generation of optimal crystallographic orientations of the grains in a polycrystalline materials (texturing) may cause hardening and reducing the deformation wear. To reveal the orientation dependence of an individual gain and simplify the task we use copper single crystals with the orientations of the compression axis along [111] and [110]. The plastic deformation was investigated by means of optical, scanning electron microscopy and EBSD techniques. It was established that at least four different zones were generated in the course of sliding test, such as non-deformed base metal, plastic deformation layer sliding, crystalline lattice reorientation layer and subsurface grain structure layer. The maximum plastic strain penetration depth was observed on [110]-single crystals. The minimum stability of [111]-crystals with respect to rotation deformation mode as well as activation of shear in the sliding contact plane provide for rotation deformation localization below the worn surface. The high-rate accumulation of misorientations and less strain penetration depth was observed on [111]-crystals as compared to those of [110]-oriented ones.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural features of plastic deformation in bulk metallic glasses

Spatially resolved strain maps of a plastically deformed bulk metallic glass (BMG) have been created by using high-energy X-ray diffraction. The results reveal that plastic deformation creates a spatially heterogeneous atomic arrangement, consisting of strong compressive and tensile strain fields. In addition, significant shear strain is introduced in the samples. The analysis of the eigenvalues and eigenvectors of the strain tensor indicates that considerable structural anisotropy occurs in both the magnitude and direction of the strain. These features are in contrast to the behavior observed in elastically deformed BMGs and represent a distinctive structural sign of plastic deformation in metallic glasses.

36 MATERIALS SCIENCE↗

Correlation between crystallization behaviour and interfacial interactions in plasticized PLA/POSS nanocomposites

In this study, the correlation between crystallization behavior and surface chemistry of polyhedral oligomeric silsesquioxanes (POSS) for plasticized poly(lactic acid) (PLA)/POSS nanocomposites was investigated. Four different kinds of POSS particles having different chemical structures were used. Poly(ethylene glycol) (PEG, 8000 g/mol) was utilized as the plasticiser. The nanocomposites were melt-compounded in an Xplore Instruments 15 cc twin screw microcompounder at 180°C barrel temperature and 100 rpm screw speed. Non-isothermal crystallization behaviour of PLA/PEG/POSS nanocomposites were evaluated from common kinetic models such as Avrami and Avrami-Ozawa and Kissinger by using the thermal data obtained from differantial scanning calorimetry (DSC). A polarized optical microscope (POM) equipped with a hot-stage was used to examine the morphology during the crystal growth. In order to investigate the interfacial interactions between POSS particles and plasticized PLA, thermodynamic work of adhesion approach was adopted using the experimentally determined surface energies. A strong correlation was obtained between interfacial chemistry and the nucleation rate in plasticized PLA/POSS nanocomposites. It was found that the polar interactions were the dominating factor which determines the nucleation activity of the POSS particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Damage-plasticity model of the host rock in a nuclear waste repository

The paper describes damage-plasticity model for the modelling of the host rock environment of a nuclear waste repository. Radioactive Waste Repository Authority in Czech Republic assumes the repository to be in a granite rock mass which exhibit anisotropic behaviour where the strength in tension is lower than in compression. In order to describe this phenomenon, the damage-plasticity model is formulated with the help of the Drucker-Prager yield criterion which can be set to capture the compression behaviour while the tensile stress states is described with the help of scalar isotropic damage model. The concept of damage-plasticity model was implemented in the SIFEL finite element code and consequently, the code was used for the simulation of the Äspö Pillar Stability Experiment (APSE) which was performed in order to determine yielding strength under various conditions in similar granite rocks as in Czech Republic. The results from the performed analysis are presented and discussed in the paper.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced piezoelectricity in plastically deformed nearly amorphous Bi{sub 12}TiO{sub 20}-BaTiO{sub 3} nanocomposites

Bulk Bi{sub 12}TiO{sub 20}-BaTiO{sub 3} (BTO-BT) nanocomposites are fabricated through the high-temperature interfacial reaction between nanometer-sized BaTiO{sub 3} particles and melting Bi{sub 12}TiO{sub 20}. Although the obtained BTO-BT nanocomposites are nearly amorphous and display very weak ferroelectricity, they exhibit relatively strong piezoelectricity without undergoing the electrical poling process. The volume fraction of crystalline Bi{sub 12}TiO{sub 20} is reduced to less than 10%, and the piezoelectric constant d{sub 33} is enhanced to 13 pC/N. Only the presence of the macroscopic polar amorphous phases can explain this unusual thermal stable piezoelectricity. Combining the results from X-ray diffraction, Raman spectroscopy, and thermal annealing, it can be confirmed that the formation of macroscopic polar amorphous phases is closely related to the inhomogeneous plastic deformation of the amorphous Bi{sub 12}TiO{sub 20} during the sintering process. These results highlight the key role of plastically deformed amorphous Bi{sub 12}TiO{sub 20} in the Bi{sub 12}TiO{sub 20}-based polar composites, and the temperature gradient driven coupling between the plastic strain gradient and polarization in amorphous phases is the main poling mechanism for this special type of bulk polar material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Relative sensitivity of plastic scintillator: A comparative analysis with 60 Co gamma rays, deuterium–deuterium, and deuterium–tritium neutrons

A plastic scintillator has found extensive application in the realm of high-energy physics and national security science. Many applications in those fields often involve the simultaneous production of photons, neutrons, and charged particles, which makes the relative sensitivity information for these different radiation types important. In this study, we have adopted a multi-head detector comprised of a plastic scintillator and high gain phototubes, which provides a large dynamic range and linearity. A comparative study on the relative sensitivities of plastic scintillators was facilitated by adopting three distinct radiation calibration sources (i.e., 60 Co γ rays, DD neutrons, and DT neutrons). Neutrons from a DD source generate a comparable level of scintillation to gamma rays emitted by 60 Co (i.e., 60 Co-γ/DD-n = 0.92 ± 16%). DT neutrons induce ~3.5 times the scintillation observed with DD neutrons (i.e., DT-n/DD-n = 3.5 ± 28%). In addition, the Geant4 simulation granted us valuable insights into the relative sensitivity of the scintillator. This comparative study will provide a useful database for users in diverse applications.

47 OTHER INSTRUMENTATION↗

Age-related changes in the plasticity and toughness of human cortical bone at multiple length-scales

The structure of human cortical bone evolves over multiple length-scales from its basic constituents of collagen and hydroxyapatite at the nanoscale to osteonal structures at nearmillimeter dimensions, which all provide the basis for its mechanical properties. To resist fracture, bone’s toughness is derived intrinsically through plasticity (e.g., fibrillar sliding) at structural-scales typically below a micron and extrinsically (i.e., during crack growth) through mechanisms (e.g., crack deflection/bridging) generated at larger structural-scales. Biological factors such as aging lead to a markedly increased fracture risk, which is often associated with an age-related loss in bone mass (bone quantity). However, we find that age-related structural changes can significantly degrade the fracture resistance (bone quality) over multiple lengthscales. Using in situ small-/wide-angle x-ray scattering/diffraction to characterize sub-micron structural changes and synchrotron x-ray computed tomography and in situ fracture-toughness measurements in the scanning electron microscope to characterize effects at micron-scales, we show how these age-related structural changes at differing size-scales degrade both the intrinsic and extrinsic toughness of bone. Specifically, we attribute the loss in toughness to increased non-enzymatic collagen cross-linking which suppresses plasticity at nanoscale dimensions and to an increased osteonal density which limits the potency of crack-bridging mechanisms at micron-scales. The link between these processes is that the increased stiffness of the cross-linked collagen requires energy to be absorbed by “plastic” deformation at higher structural levels, which occurs by the process of microcracking.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization and engineering of a plastic-degrading aromatic polyesterase

Significance Synthetic polymers are ubiquitous in the modern world but pose a global environmental problem. While plastics such as poly(ethylene terephthalate) (PET) are highly versatile, their resistance to natural degradation presents a serious, growing risk to fauna and flora, particularly in marine environments. Here, we have characterized the 3D structure of a newly discovered enzyme that can digest highly crystalline PET, the primary material used in the manufacture of single-use plastic beverage bottles, in some clothing, and in carpets. We engineer this enzyme for improved PET degradation capacity and further demonstrate that it can also degrade an important PET replacement, polyethylene-2,5-furandicarboxylate, providing new opportunities for biobased plastics recycling.

09 BIOMASS FUELS↗

Size of Plastic Events in Strained Amorphous Solids at Finite Temperatures

We address the system-size dependence of plastic flow events when an amorphous solid is put under a fixed external strain rate at a finite temperature. For small system sizes at low strain rates and low temperatures the magnitude of plastic events grows with the system size. We explain, however, that this must be a finite-size effect; for larger systems there exist two crossover length scales xi{sub 1} and xi{sub 2}, the first determined by the elastic time scale and the second by the thermal energy scale. For systems of size L>>xi there must exist (L/xi){sup d} uncorrelated plastic events which occur simultaneously. We present a scaling theory that culminates with the dependence of the crossover scales on temperature and strain rate. Finally, we relate these findings to the temperature and size dependence of the stress fluctuations. We comment on the importance of these considerations for theories of elastoplasticity.

36 MATERIALS SCIENCE↗

Crystal plasticity finite element simulation of lattice rotation and x-ray diffraction during laser shock compression of tantalum

Here we present a crystal plasticity model tailored for high-pressure, high-strain-rate conditions that uses a multiscale treatment of dislocation-based slip kinetics. We use this model to analyze the pronounced plasticity-induced lattice rotations observed in shock-compressed polycrystalline tantalum via in situ x-ray diffraction. By making direct comparisons between experimentally measured and simulated texture evolution, we can explain how the details of the underlying slip kinetics control the degree of lattice rotation that ensues. Specifically, we show that only the highly nonlinear kinetics caused by dislocation nucleation can explain the magnitude of the rotation observed under shock compression. We demonstrate a good fit between our crystal plasticity model and x-ray diffraction data and exploit the data to quantify the dislocation nucleation rates that are otherwise poorly constrained by experiment in the dynamic compression regime.

36 MATERIALS SCIENCE↗

Structural properties of plastically deformed SrTiO 3 and KTaO 3

Dislocation engineering has the potential to open new avenues toward the exploration and modification of the properties of quantum materials. Strontium titanate (SrTi⁢O 3 , STO) and potassium tantalate (KTa⁢O 3 , KTO) are incipient ferroelectrics that show metallization and superconductivity at extremely low charge-carrier concentrations and have been the subject of resurgent interest. These materials also exhibit remarkable ambient-temperature ductility, and thus represent exceptional platforms for studies of the effects of deformation-induced dislocation structures on electronic properties. Recent work on plastically deformed STO revealed an enhancement of the superconducting transition temperature and the emergence of local ferroelectricity and magnetism near self-organized dislocation walls. Here, in this work, we present a comprehensive structural analysis of plastically deformed STO and KTO, employing specially designed strain cells, diffuse neutron and x-ray scattering, Raman scattering, and nuclear magnetic resonance (NMR). Diffuse scattering and NMR provide insight into the dislocation configurations and densities and their dependence on strain. As in the prior work on STO, Raman scattering reveals evidence for local ferroelectric order near dislocation walls in plastically deformed KTO. Our findings provide valuable information about the self-organized defect structures in both materials, and they position KTO as a second model system in which to explore the associated emergent physics.

36 MATERIALS SCIENCE↗

Highly lead-loaded red plastic scintillators as an X-ray imaging system for the Laser Mega Joule

The scope of this project intends to record spatially resolved images of core shape and size of a DT micro-balloon during Inertial Confinement Fusion (ICF) experiments at Laser Mega Joule facility (LMJ). We need to develop an X-ray imaging system which can operate in the radiative background generated by an ignition shot of ICF. The scintillator is a part of the imaging system and has to gather a compromise of scintillating properties (scintillating efficiency, decay time, emission wavelength) so as to both operate in the hard radiative environment and to allow the acquisition of spatially resolved images. Inorganic scintillators cannot be used because no compromise can be found regarding the expected scintillating properties, most of them are not fast enough and emit blue light. Organic scintillators are generally fast, but present low X-ray absorption in the 10 to 40 keV range, that does not permit the acquisition of spatially resolved images. To this aim, we have developed highly lead-loaded and red-fluorescent fast plastic scintillators. Such a combination is not currently available via scintillator suppliers, since they propose only blue-fluorescent plastic scintillators doped with up to 12%w Pb. Thus, incorporation ratio up to 27%w Pb has been reached in our laboratory, which can afford a plastic scintillator with an outstanding Z{sub eff} close to 50. X-rays in the 10 to 40 keV range can thus be detected with a higher probability of photoelectric effect than for classic organic scintillators, such as NE102. The strong orange-red fluorescence can be filtered, so that we can eliminate residual Cerenkov light, generated by {gamma}-ray absorption in glass parts of the imaging system. Decay times of our scintillators evaluated under UV excitation were estimated to be in the range 10 to 13 ns. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of a cyclic plasticity computational method using fatigue full-field deformation measurements

The evolution of crack tip displacement and strain fields during uniaxial, room temperature, low-cycle fatigue experiments of Nickel superalloy compact tension specimens was measured by a digital image correlation approach and was further used to validate a cyclic plasticity model and corresponding deformation calculations made by a finite elements methodology. The experimental results provided data trends for the opening displacements and near crack tip strains as function of cycles. A finite element model was developed to capture test conditions for a measured crack size. The model captures crack tip plasticity by using a constitutive model calibrated against stress-strain measurements performed on a round bar. Similar quantities were extracted from the model predictions to compare with the digital image correlation measurements for model validation purposes. This type of direct comparison demonstrated that the computational model was capable to adequately capture the crack opening displacements at various stages of the specimen's fatigue life, providing in this way a tool for quantitative cyclic plasticity model validation. In addition, this integrated experimental-computational approach provides a framework to accelerate our understanding related to interactions of fatigue test data and models, as well as ways to inform one another.

36 MATERIALS SCIENCE↗

Understanding the Elastic, Plastic, and Damage Features in Fracturing of Self-reinforced Thermoplastic Composites via Non-destructive Digital Imaging Correlation

This work demonstrated the utilization of non-destructive Digital Imaging Correlation (DIC) method to characterize the elastic, plastic, and damage features during the Mode I intra-laminar fracturing process of self-reinforced thermoplastic composites by using a self-reinforced polypropylene (PP) composite as an example. The DIC results clearly showed the development of huge plastic zone (PZ) and non-negligible Fracture Process Zone (FPZ) in front of the notch tip during the fracturing process, and the geometries and sizes of the foregoing zones at the peak load were further quantified. Such an interesting fracturing behavior of self-reinforced thermoplastic composites is way different from brittle materials (e.g., glass, acrylic, etc.), ductile materials (e.g., aluminum, steel, etc.), and even quasi-brittle materials (e.g., concrete, nanoparticle-reinforced composites, tough ceramics, wood, cement, carbon/glass fiber-reinforced polymers, etc.). Thus, understanding the elastic, plastic, and damage features is the first step before better characterizing the material fracture properties of self-reinforced thermoplastic composites through new analytical methods and computational modeling. These efforts are of utmost importance for wide applications of self-reinforced thermoplastic composites in various engineering fields in the future.

Lightweight Composites, Self-reinforced Thermoplas↗

A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom. The PSDs were distributed on a 26 x 26 cm{sup 2} grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm. Each PSD was made of a 1 mm diameter by 3 mm long cylindrical polystyrene scintillating fiber coupled to a clear nonscintillating plastic optical fiber. All of the light signals emitted by the PSDs were read simultaneously with an optical system at a rate of one measurement per second. We characterized the performance of the optical system, the angular dependency of the device, and the perturbation of dose distributions caused by the hundreds of PSDs inserted into the phantom. We also evaluated the capacity of the system to monitor complex multileaf collimator (MLC) sequences such as those encountered in step-and-shoot intensity modulated radiation therapy (IMRT) plans. We compared our results with calculations performed by a treatment planning system and with measurements taken with a 2D ionization chamber array and with a radiochromic film. Results: The detector array that we developed allowed us to measure doses with an average precision of better than 1% for cumulated doses equal to or greater than 6.3 cGy. Our results showed that the dose distributions produced by the 6-MV photon beam are not perturbed (within {+-}1.1%) by the presence of the hundreds of PSDs located into the phantom. The results also showed that the variations in the beam incidences have little effect on the dose response of the device. For all incidences tested, the passing rates of the gamma tests between the 2D-PSDA and the treatment planning system were higher than 97.5% when the standard clinical tolerances of 3% or 3 mm were used. Excellent agreement was obtained between the doses measured and calculated when we used the 2D-PSDA for monitoring a MLC sequence from a step-and-shoot IMRT plan. Conclusions: We demonstrated the feasibility of using a large number of PSDs in a new 2D-PSDA for the dosimetry of MV energy photon beams in radiation therapy. The excellent precision, accuracy, and low angular dependence of the device indicate that such a prototype could potentially be used as a high-accuracy quality assurance tool for IMRT and arc therapy patient plan verification. The homogeneity and water-equivalence of the prototype we built suggest that this technology could be extended to multiple detection planes by arranging the fibers into more complex orientations, opening the possibility for 3D dosimetry with PSDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of a novel water-equivalent electronic portal imaging device using plastic scintillating fibers

Purpose: Most electronic portal imaging devices (EPIDs) developed so far use a thin Cu plate/phosphor screen to convert x-ray energies into light photons, while maintaining a high spatial resolution. This results in a low x-ray absorption and thus a low quantum efficiency (QE) of approximately 2-4% for megavoltage (MV) x-rays. A significant increase of QE is desirable for applications such as MV cone-beam computed tomography (MV-CBCT). Furthermore, the Cu plate/phosphor screen contains high atomic number (high-Z) materials, resulting in an undesirable over-response to low energy x-rays (due to photoelectric effect) as well as high energy x-rays (due to pair production) when used for dosimetric verification. Our goal is to develop a new MV x-ray detector that has a high QE and uses low-Z materials to overcome the obstacles faced by current MV x-ray imaging technologies. Methods: A new high QE and low-Z EPID is proposed. It consists of a matrix of plastic scintillating fibers embedded in a water-equivalent medium and coupled to an optically sensitive 2D active matrix flat panel imager (AMFPI) for image readout. It differs from the previous approach that uses segmented crystalline scintillators made of higher density and higher atomic number materials to detect MV x-rays. The plastic scintillating fibers are focused toward the x-ray source to avoid image blurring due to oblique incidence of off-axis x-rays. When MV x-rays interact with the scintillating fibers in the detector, scintillation light will be produced. The light photons produced in a fiber core and emitted within the acceptance angle of the fiber will be guided toward the AMFPI by total internal reflection. A Monte Carlo simulation has been used to investigate imaging and dosimetric characteristics of the proposed detector under irradiation of MV x-rays. Results: Properties, such as detection efficiency, modulation transfer function, detective quantum efficiency (DQE), energy dependence of detector response, and water-equivalence of dose response have been investigated. It has been found that the zero frequency DQE of the proposed detector can be up to 37% at 6 MV. The detector, also, is water-equivalent with a relatively uniform response to different energy x-rays as compared to current EPIDs. Conclusions: The results of our simulations show that, using plastic scintillating fibers, it is possible to construct a water-equivalent EPID that has a better energy response and a higher detection efficiency than current flat panel based EPIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-50: Study On the Magnetic Field Effect On the Exradin W1 Plastic Scintillation Detector

Purpose: To study the response of the Exradin W1 plastic scintillator detector to a 6 MV photon field in the presence of a strong magnetic field (B). Methods: An Exradin W1 scintillator detector coupled to a SuperMax two-channel electrometer, both manufactured by Standard Imaging, Inc., was first calibrated in a Co-60 beam. The Cerenkov Light Ratio (CLR) was obtained following the procedure recommended by the manufacturer. Subtracting signal in channel 2 multiplied by CLR from the signal in channel 1 should lead to a Cerenkov-free signal. The W1 scintillator was placed in a plastic phantom inside a dipole electromagnet (GMW Associates) that could produce a strong B field, and irradiated using a 6 MV beam from an Elekta Versa HD LINAC. Signals from both channels of the W1 scintillator were acquired as a function of B (0 - 1.5 T). Results: The signals from both channels increased as a function of the B field strength. At 1.5 T, channel 1 increased by 11% compared to the baseline (B=0 T), while channel 2 increased by 22%. Applying the recommended Cerenkov correction led to a 2% difference between dose measurement with and without a magnetic field. The values between B=0.3 T and B=1.5 T remained constant. Conclusion: Signals from the Exradin W1 plastic scintillation detector increased as the B field increased. This increase mainly comes from a change in the amount of Cerenkov light coupled within the optical fiber. Removing the Cerenkov component following the procedure recommended by the manufacturer showed to be an effective way to measure dose accurately in strong magnetic fields. The cause for the residual 2% difference is currently under investigation. We acknowledge research support from Elekta AB.

60 APPLIED LIFE SCIENCES↗

TH-CD-BRA-12: Impact of a Magnetic Field On the Response From a Plastic Scintillation Detector

Purpose: To study the effect of a strong magnetic field on the scintillation and the stem effect from a plastic scintillation detector (PSD) and evaluate its accuracy to measure dose. Methods: A plastic scintillation detector and a bare plastic fiber were placed inside a magnet of adjustable field strength (B=0−1.5T) and irradiated by a 6-MV photon beam (Elekta Versa HD LINAC). The PSD was built in-house using a scintillating fiber (BCF-60, 3-mm long × 1-mm diameter) coupled to an optical fiber similar to the bare fiber (PMMA, 12-m long, 1-mm diameter). Light output spectra were acquired with a spectrometer. Intensity and shape of the output spectra were compared as a function of the magnetic field strength. The bare fiber was used to study the behavior of the stem effect (composed of Cerenkov and fluorescence). The spectrometry setup allowed to perform a previously demonstrated hyperspectral stem-effect removal and calculated dose was studied as a function of the magnetic field strength. Results: Signal intensities were shown to increase with the magnetic field strength by up to 19% and 79% at 1.5T in comparison to the irradiation without a magnetic field, for respectively the PSD and the bare fiber. The light produced by Cerenkov effect in the optical fiber was shown to be the major component affected by the magnetic field. Effect of the magnetic field on the electrons trajectory may explain this behavior. Finally, accounting for the stem effect using the hyperspectral approach led to accuracy in dose measurement within 2.6%. Interestingly, variations in accuracy were negligible for values over 0.3T. Conclusion: Dependence of PSDs to magnetic field is mainly due to the Cerenkov light. When accounting for it, PSDs become a candidate of choice for both quality assurance and in vivo dosimetry of therapy under strong magnetic fields (e.g. for MRI-Linacs).

60 APPLIED LIFE SCIENCES↗