Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “planning optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

IMRT vs. 3D Noncoplanar Treatment Plans for Maxillary Sinus Tumors: A New Tool for Quantitative Evaluation

We compared 9-field, equispaced intensity modulated radiation therapy (IMRT), 4- to 5-field, directionally optimized IMRT, and 3-dimensional (3D) noncoplanar planning approaches for tumors of the maxillary sinus. Ten patients were planned retrospectively to compare the different treatment techniques. Prescription doses were 60 to 70 Gy. Critical structures contoured included optic nerves and chiasm, lacrimal glands, lenses, and retinas. As an aid for plan assessment, we introduced a new tool: Critical Organ Scoring Index (COSI), which allows quantitative evaluation of the tradeoffs between target coverage and critical organ sparing. This index was compared with other, commonly used conformity indices. For a reliable assessment of both tumor coverage and dose to critical organs in the different planning techniques, we introduced a 2D, graphical representation of COSI vs. conformity index (CI). Dose-volume histograms and mean, maximum, and minimum organ doses were also compared. IMRT plans delivered lower doses to ipsilateral structures, but were unable to spare them. 3D plans delivered less dose to contralateral structures, and were more homogeneous, as well. Both IMRT approaches gave similar results. In cases where choice of optimal plan was difficult, the novel 2D COSI-CI representation gave an accurate picture of the tradeoffs between target coverage and organ sparing, even in cases where other conformity indices failed. Due to their unique anatomy, maxillary sinus tumors may benefit more from a noncoplanar approach than from IMRT. The new graphical representation proposed is a quick, visual, reliable tool, which may facilitate the physician's choice of best treatment plan for a given patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Predictive Treatment Management: Incorporating a Predictive Tumor Response Model Into Robust Prospective Treatment Planning for Non-Small Cell Lung Cancer

Purpose: We hypothesized that a treatment planning technique that incorporates predicted lung tumor regression into optimization, predictive treatment planning (PTP), could allow dose escalation to the residual tumor while maintaining coverage of the initial target without increasing dose to surrounding organs at risk (OARs). Methods and Materials: We created a model to estimate the geometric presence of residual tumors after radiation therapy using planning computed tomography (CT) and weekly cone beam CT scans of 5 lung cancer patients. For planning purposes, we modeled the dynamic process of tumor shrinkage by morphing the original planning target volume (PTV{sub orig}) in 3 equispaced steps to the predicted residue (PTV{sub pred}). Patients were treated with a uniform prescription dose to PTV{sub orig}. By contrast, PTP optimization started with the same prescription dose to PTV{sub orig} but linearly increased the dose at each step, until reaching the highest dose achievable to PTV{sub pred} consistent with OAR limits. This method is compared with midcourse adaptive replanning. Results: Initial parenchymal gross tumor volume (GTV) ranged from 3.6 to 186.5 cm{sup 3}. On average, the primary GTV and PTV decreased by 39% and 27%, respectively, at the end of treatment. The PTP approach gave PTV{sub orig} at least the prescription dose, and it increased the mean dose of the true residual tumor by an average of 6.0 Gy above the adaptive approach. Conclusions: PTP, incorporating a tumor regression model from the start, represents a new approach to increase tumor dose without increasing toxicities, and reduce clinical workload compared with the adaptive approach, although model verification using per-patient midcourse imaging would be prudent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-569: Evaluation of VMAT Plans Generated with HD120 and Millennium 120 MLC Between Two Matched Linacs

Purpose: To evaluate VMAT treatment plans generated with HD120 MLC and Millennium 120 MLC between two matched linacs and to determine if one can back up the other. Methods: The 6x photon beams are matched for our Varian TrueBeam STx and Trilogy linacs, which are equipped with HD120 MLC and Millennium 120 MLC, respectively. Three prostate and three brain VMAT plans were used for the evaluation. Five plans (three prostate and two brain plans) were originally generated with the TrueBeam STx and re-computed with the Trilogy. One brain plan was evaluated the other way around. For each plan, the PTV coverage of V95 was made the same between two linacs. The dosimetric differences associated with the plans were compared using: 1) Percentage mean dose differences to the PTV, 2) Homogeneity index, HI = (Dmax − Dmin)/Dmean for the PTV. For prostate plans, the mean dose differences to the rectum were evaluated. While for brain plans, the percentage max dose differences to the lenses (left and right lens) were evaluated. Results: For three prostate plans, the average of the percentage mean dose differences to the PTV was 0.5 ± 0.1% and the HI was 0.1 ± 0.0%. The average of the percentage mean dose difference to the rectum was 3.5 ± 0.5%. For three brain plans, the average of the percentage mean dose differences to the PTV was 0.2 ± 1.1% and the HI was 0.2 ± 0.1%. The average of the percentage max dose differences to the lenses was 22.9 ± 4.0%. Conclusion: For prostate VMAT plans, changing the treatment from the TrueBeam STx to the Trilogy does not necessarily need re-optimization. But for brain plans, in order to minimize dose to the lenses, it is recommended to re-optimize the plan if changing the treatment between these two linacs.

60 APPLIED LIFE SCIENCES↗

Evaluating Target Cold Spots By the use of Tail EUDs

Purpose: To propose a new measure of target underdose that can be used in the evaluation and optimization of radiotherapy dose distributions. Methods and Materials: We compare various formulations of the equivalent uniform dose (EUD) and introduce a modification of existing EUD definitions, which we call tail EUD. Tail EUD is a measure of 'cold spots' below the prescription dose in the target dose distribution, using units of gray (Gy). We investigate the mathematical properties of various target EUD concepts, including tail EUD. We apply the tail EUD measure retrospectively to intensity modulated radiation therapy (IMRT) treatment plans from our plan database. We also use tail EUD as an optimization objective in the optimization of prostate, pancreas, and head-and-neck plans. Results: Tail EUD has desirable mathematical properties. In particular, it is convex and it leads to convex level sets (i.e., no local minima) if the EUD from which it is derived is concave. The tail EUD value is correlated with the subjective degree of target coverage. Constraining tail EUDs to a certain level in plan optimization leads to comparable target coverage in different plans and treatment sites. Conclusions: The newly introduced concept of tail EUD appears to be useful for both plan evaluation and optimization. In addition it can potentially be applied in the design of new clinical protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-197: Helical Cranial-Spinal Treatments with a Linear Accelerator

Purpose: Craniospinal irradiation (CSI) of systemic disease requires a high level of beam intensity modulation to reduce dose to bone marrow and other critical structures. Current helical delivery machines can take 30 minutes or more of beam-on time to complete these treatments. This pilot study aims to test the feasibility of performing helical treatments with a conventional linear accelerator using longitudinal couch travel during multiple gantry revolutions. Methods: The VMAT optimization package of the Eclipse 10.0 treatment planning system was used to optimize pseudo-helical CSI plans of 5 clinical patient scans. Each gantry revolution was divided into three 120° arcs with each isocenter shifted longitudinally. Treatments requiring more than the maximum 10 arcs used multiple plans with each plan after the first being optimized including the dose of the others (Figure 1). The beam pitch was varied between 0.2 and 0.9 (couch speed 5- 20cm/revolution and field width of 22cm) and dose-volume histograms of critical organs were compared to tomotherapy plans. Results: Viable pseudo-helical plans were achieved using Eclipse. Decreasing the pitch from 0.9 to 0.2 lowered the maximum lens dose by 40%, the mean bone marrow dose by 2.1% and the maximum esophagus dose by 17.5%. (Figure 2). Linac-based helical plans showed dose results comparable to tomotherapy delivery for both target coverage and critical organ sparing, with the D50 of bone marrow and esophagus respectively 12% and 31% lower in the helical linear accelerator plan (Figure 3). Total mean beam-on time for the linear accelerator plan was 8.3 minutes, 54% faster than the tomotherapy average for the same plans. Conclusions: This pilot study has demonstrated the feasibility of planning pseudo-helical treatments for CSI targets using a conventional linac and dynamic couch movement, and supports the ongoing development of true helical optimization and delivery.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 65: A dosimetric comparison of isocentric and non-isocentric coplanar SBRT VMAT plans for peripheral lung tumours

Volumetric modulated arc therapy (VMAT) delivers lung sterotactic body radiotherapy (SBRT) in shorter treatment time and less monitor units with comparable coverage and organ at risk sparing compared to conventional SBRT treatments. Isocentric VMAT treatment of peripheral lung tumours occasionally requires couch shifts that can inhibit 360° gantry rotation, resulting in additional imaging shifts for each treatment session, and increased potential for involuntary in-fraction motion. Here, we investigate whether non-isocentric VMAT plans can achieve comparable plan quality to isocentric plans for peripheral lung tumours. Three patient plans were selected with targets displaced > 8.5 cm (range: 8.8 – 9.9 cm) laterally from patient midline. For each patient, a plan with isocentre placed within the target volume (isocentric plan) was created and optimized. The same optimization parameters were then used to create a plan with the isocentre at patient midline (non-isocentric plan). Plan quality was evaluated and compared based on planning target volume (PTV) coverage, high dose spillage, dose homogeneity, intermediate dose spillage, dose fall-off gradient, and organ at risk contraints. Non-isocentric plans of equivalent plan quality to isocentric plans were achieved for all patients by optimizing collimator rotations. Field isocentres can be placed at patient midline, as opposed to inside the target volume, with no significant degradation in VMAT plan quality for lateral tumour displacements up to 10 cm. Non-isocentric treatment of peripheral lung tumours could result in decreased overall treatment session time and eliminate the need for imaging shifts prior to VMAT treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-614: Plan Averaging for Multi-Criteria Navigation of Step-And-Shoot IMRT

Purpose: Step-and-shoot IMRT is fundamentally discrete in nature, while multi-criteria optimization (MCO) is fundamentally continuous: the MCO planning consists of continuous sliding across the Pareto surface (the set of plans which represent the tradeoffs between organ-at-risk doses and target doses). In order to achieve close to real-time dose display during this sliding, it is desired that averaged plans share many of the same apertures as the pre-computed plans, since dose computation for apertures generated on-the-fly would be expensive. We propose a method to ensure that neighboring plans on a Pareto surface share many apertures. Methods: Our baseline step-and-shoot sequencing method is that of K. Engel (a method which minimizes the number of segments while guaranteeing the minimum number of monitor units), which we customize to sequence a set of Pareto optimal plans simultaneously. We also add an error tolerance to study the relationship between the number of shared apertures, the total number of apertures needed, and the quality of the fluence map re-creation. Results: We run tests for a 2D Pareto surface trading off rectum and bladder dose versus target coverage for a clinical prostate case. We find that if we enforce exact fluence map recreation, we are not able to achieve much sharing of apertures across plans. The total number of apertures for all seven beams and 4 plans without sharing is 217. With sharing and a 2% error tolerance, this number is reduced to 158 (73%). Conclusion: With the proposed method, total number of apertures can be decreased by 42% (averaging) with no increment of total MU, when an error tolerance of 5% is allowed. With this large amount of sharing, dose computations for averaged plans which occur during Pareto navigation will be much faster, leading to a real-time what-you-see-is-what-you-get Pareto navigation experience. Minghao Guo and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast intensity-modulated arc therapy based on 2-step beam segmentation

Purpose: Single or few arc intensity-modulated arc therapy (IMAT) is intended to be a time saving irradiation method, potentially replacing classical intensity-modulated radiotherapy (IMRT). The aim of this work was to evaluate the quality of different IMAT methods with the potential of fast delivery, which also has the possibility of adapting to the daily shape of the target volume. Methods: A planning study was performed. Novel double and triple IMAT techniques based on the geometrical analysis of the target organ at risk geometry (2-step IMAT) were evaluated. They were compared to step and shoot IMRT reference plans generated using direct machine parameter optimization (DMPO). Volumetric arc (VMAT) plans from commercial preclinical software (SMARTARC) were used as an additional benchmark to classify the quality of the novel techniques. Four cases with concave planning target volumes (PTV) with one dominating organ at risk (OAR), viz., the PTV/OAR combination of the ESTRO Quasimodo phantom, breast/lung, spine metastasis/spinal cord, and prostate/rectum, were used for the study. The composite objective value (COV) and other parameters representing the plan quality were studied. Results: The novel 2-step IMAT techniques with geometry based segment definition were as good as or better than DMPO and were superior to the SMARTARC VMAT techniques. For the spine metastasis, the quality measured by the COV differed only by 3%, whereas the COV of the 2-step IMAT for the other three cases decreased by a factor of 1.4-2.4 with respect to the reference plans. Conclusions: Rotational techniques based on geometrical analysis of the optimization problem (2-step IMAT) provide similar or better plan quality than DMPO or the research version of SMARTARC VMAT variants. The results justify pursuing the goal of fast IMAT adaptation based on 2-step IMAT techniques.

60 APPLIED LIFE SCIENCES↗

Using hydrogen and ammonia for renewable energy storage: A geographically comprehensive techno-economic study

Hydrogen and, more recently, ammonia have received worldwide attention as energy storage media. In this work we investigate the economics of using each of these chemicals as well as the two in combination for islanded renewable energy supply systems in 15 American cities representing different climate regions throughout the country. We use an optimal combined capacity planning and scheduling model which minimizes the levelized cost of energy (LCOE) by determining optimal unit selection and size along with unit commitments, production rates, and storage inventories for each period of system operation. These periods are aggregated from full year hourly resolution data via a consecutive temporal clustering algorithm. Ammonia is generally more economical than hydrogen as a single method of energy storage. Additionally, systems which use both hydrogen and ammonia outperform those which use only one storage option and have LCOE between $\$ 0.17$/kWh and $\$ 0.28$/kWh, including full investment in renewable generation infrastructure.

25 ENERGY STORAGE↗

Dosimetric effect of beam arrangement for intensity-modulated radiation therapy in the treatment of upper thoracic esophageal carcinoma

To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plans were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V{sub 5}, V{sub 13}, V{sub 20}, mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V{sub 30} for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity-modulated radiation therapy technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

Westinghouse Waste Simulation and Optimization Software Tool - 13493

Radioactive waste is produced during NPP operation and NPP D and D. Different kinds of waste with different volumes and properties have to be treated. Finding a technically and commercially optimized waste treatment concept is a difficult and time consuming process. The Westinghouse waste simulation and optimization software tool is an approach to study the total life cycle cost of any waste management facility. The tool enables the user of the simulation and optimization software to plan processes and storage buildings and to identify bottlenecks in the overall waste management design before starting detailed planning activities. Furthermore, application of the software enables the user to optimize the number of treatment systems, to determine the minimum design capacity for onsite storage facilities, to identify bottlenecks in the overall design and to identify the most cost-effective treatment paths by maintaining optimal waste treatment technologies. In combination with proven waste treatment equipment and integrated waste management solutions, the waste simulation and optimization software provides reliable qualitative results that lead to an effective planning and minimization of the total project planning risk of any waste management activity. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of {sup 18}F-Fluorothymidine and {sup 18}F-Fluorodeoxyglucose PET/CT in Delineating Gross Tumor Volume by Optimal Threshold in Patients With Squamous Cell Carcinoma of Thoracic Esophagus

Purpose: To determine the optimal method of using {sup 18}F-fluorothymidine (FLT) positron emission tomography (PET)/computed tomography (CT) simulation to delineate the gross tumor volume (GTV) in esophageal squamous cell carcinoma verified by pathologic examination and compare the results with those using {sup 18}F-fluorodeoxyglucose (FDG) PET/CT. Methods and Materials: A total of 22 patients were enrolled and underwent both FLT and FDG PET/CT. The GTVs with biologic information were delineated using seven different methods in FLT PET/CT and three different methods in FDG PET/CT. The results were compared with the pathologic gross tumor length, and the optimal threshold was obtained. Next, we compared the simulation plans using the optimal threshold of FLT and FDG PET/CT. The radiation dose was prescribed as 60 Gy in 30 fractions with a precise radiotherapy technique. Results: The mean +- standard deviation pathologic gross tumor length was 4.94 +- 2.21 cm. On FLT PET/CT, the length of the standardized uptake value 1.4 was 4.91 +- 2.43 cm. On FDG PET/CT, the length of the standardized uptake value 2.5 was 5.10 +- 2.18 cm, both of which seemed more approximate to the pathologic gross tumor length. The differences in the bilateral lung volume receiving >=20 Gy, heart volume receiving >=40 Gy, and the maximal dose received by spinal cord between FLT and FDG were not significant. However, the values for mean lung dose, bilateral lung volume receiving >=5, >=10, >=30, >=40, and >=50 Gy, mean heart dose, and heart volume receiving >=30 Gy using FLT PET/CT-based planning were significant lower than those using FDG PET/CT. Conclusion: A standardized uptake value cutoff of 1.4 on FLT PET/CT and one of 2.5 on FDG PET/CT provided the closest estimation of GTV length. Finally, FLT PET/CT-based treatment planning provided potential benefits to the lungs and heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Specific Monte Carlo-Based Dose-Kernel Approach for Inverse Planning in Afterloading Brachytherapy

Purpose: Brachytherapy planning software relies on the Task Group report 43 dosimetry formalism. This formalism, based on a water approximation, neglects various heterogeneous materials present during treatment. Various studies have suggested that these heterogeneities should be taken into account to improve the treatment quality. The present study sought to demonstrate the feasibility of incorporating Monte Carlo (MC) dosimetry within an inverse planning algorithm to improve the dose conformity and increase the treatment quality. Methods and Materials: The method was based on precalculated dose kernels in full patient geometries, representing the dose distribution of a brachytherapy source at a single dwell position using MC simulations and the Geant4 toolkit. These dose kernels are used by the inverse planning by simulated annealing tool to produce a fast MC-based plan. A test was performed for an interstitial brachytherapy breast treatment using two different high-dose-rate brachytherapy sources: the microSelectron iridium-192 source and the electronic brachytherapy source Axxent operating at 50 kVp. Results: A research version of the inverse planning by simulated annealing algorithm was combined with MC to provide a method to fully account for the heterogeneities in dose optimization, using the MC method. The effect of the water approximation was found to depend on photon energy, with greater dose attenuation for the lower energies of the Axxent source compared with iridium-192. For the latter, an underdosage of 5.1% for the dose received by 90% of the clinical target volume was found. Conclusion: A new method to optimize afterloading brachytherapy plans that uses MC dosimetric information was developed. Including computed tomography-based information in MC dosimetry in the inverse planning process was shown to take into account the full range of scatter and heterogeneity conditions. This led to significant dose differences compared with the Task Group report 43 approach for the Axxent source.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systematic Layout Planning of a Radiology Reporting Area to Optimize Radiologists’ Performance

Optimizing radiologists’ performance is a major priority for managers of health services/systems, since the radiologists’ reporting activity imposes a severe constraint on radiology productivity. Despite that, methods to optimize radiologists’ reporting workplace layout are scarce in the literature. This study was performed in the Radiology Division (RD) of an 850-bed University-based general hospital. The analysis of the reporting workplace layout was carried out using the systematic layout planning (SLP) method, in association with cluster analysis as a complementary tool in early stages of SLP. Radiologists, architects, and hospital managers were the stakeholders consulted for the completion of different stages of the layout planning process. A step-by-step description of the proposed methodology to plan an RD reporting layout is presented. Clusters of radiologists were defined using types of exams reported and their frequency of occurrence as clustering variables. Sectors with high degree of interaction were placed in proximity in the new RD layout, with separation of noisy and quiet areas. Four reporting cells were positioned in the quiet area, grouping radiologists by subspecialty, as follows: cluster 1-abdomen; cluster 2-musculoskeletal; cluster 3-neurological, vascular and head & neck; cluster 4-thoracic and cardiac. The creation of reporting cells has the potential to limit unplanned interruptions and enhance the exchange of knowledge and information within cells, joining radiologists with the same expertise. That should lead to improvements in productivity, allowing managers to more easily monitor radiologists’ performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a Machine-Learning Algorithm for Treatment Planning in Prostate Low-Dose-Rate Brachytherapy

Purpose: This work presents the application of a machine learning (ML) algorithm to automatically generate high-quality, prostate low-dose-rate (LDR) brachytherapy treatment plans. The ML algorithm can mimic characteristics of preoperative treatment plans deemed clinically acceptable by brachytherapists. The planning efficiency, dosimetry, and quality (as assessed by experts) of preoperative plans generated with an ML planning approach was retrospectively evaluated in this study. Methods and Materials: Preimplantation and postimplantation treatment plans were extracted from 100 high-quality LDR treatments and stored within a training database. The ML training algorithm matches similar features from a new LDR case to those within the training database to rapidly obtain an initial seed distribution; plans were then further fine-tuned using stochastic optimization. Preimplantation treatment plans generated by the ML algorithm were compared with brachytherapist (BT) treatment plans in terms of planning time (Wilcoxon rank sum, α = 0.05) and dosimetry (1-way analysis of variance, α = 0.05). Qualitative preimplantation plan quality was evaluated by expert LDR radiation oncologists using a Likert scale questionnaire. Results: The average planning time for the ML approach was 0.84 ± 0.57 minutes, compared with 17.88 ± 8.76 minutes for the expert planner (P=.020). Preimplantation plans were dosimetrically equivalent to the BT plans; the average prostate V150% was 4% lower for ML plans (P=.002), although the difference was not clinically significant. Respondents ranked the ML-generated plans as equivalent to expert BT treatment plans in terms of target coverage, normal tissue avoidance, implant confidence, and the need for plan modifications. Respondents had difficulty differentiating between plans generated by a human or those generated by the ML algorithm. Conclusions: Prostate LDR preimplantation treatment plans that have equivalent quality to plans created by brachytherapists can be rapidly generated using ML. The adoption of ML in the brachytherapy workflow is expected to improve LDR treatment plan uniformity while reducing planning time and resources.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of MLC Leaf Width and PTV Margin on the Treatment Planning of Intensity-Modulated Stereotactic Radiosurgery (IMSRS) or Radiotherapy (IMSRT)

We studied the effect of MLC (multileaf collimator) leaf width and PTV (planning target volume) margin on treatment planning of intensity modulated stereotactic radiosurgery (IMSRS) or radiotherapy (IMSRT). Twelve patients previously treated with IMSRS/IMSRT were retrospectively planned with 5- and 3-mm MLC leaf widths and 3- and 2-mm PTV margins using the already contoured clinical target volume and critical structures. The same beam arrangement, planning parameters, and optimization method were used in each of the 4 plans for a given patient. Each plan was normalized so that the prescription dose covered at least 99% of the PTV. Plan indices - D{sub mean} (mean dose), conformity index (CI), V{sub 70} (volume receiving {>=} 70% of the prescription dose), and V{sub 50} (volume receiving {>=} 50% of the prescription dose) - were calculated from the dose-volume histograms (DVHs) of the PTV, normal tissue, and organs at risk (OARs). Hypothesis testing was performed on the mean ratios of plan indices to determine the statistical significance of the relative differences. The PTV was well covered for all plans, as no significant differences were observed for D{sub 95}, V{sub 95}, D{sub max}, D{sub min}, and D{sub mean} of the PTV. The irradiated volume was {approx}23% smaller when 2-mm instead of 3-mm PTV margin was used, but it was only reduced by {approx}6% when the MLC leaf width was reduced from 5 mm to 3 mm. For normal tissue and brainstem, V{sub 70}, V{sub 50}, and D{sub mean} were reduced more effectively by a decrease in MLC width, while D{sub mean} of optic nerve and chiasm were more sensitive to a change in PTV margin. The DVH statistics for the PTV and normal structures from the treatment plan with 5-mm MLC and 2-mm PTV margin were equal to those with 3-mm MLC and 3-mm PTV margin. PTV margin reduction is more effective in sparing the normal tissue and OARs than a reduction in MLC leaf width. For IMSRS, where highly accurate setup and small PTV margins are routinely employed, the use of 5-mm MLC is therefore less desirable.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spot Scanning Proton Therapy for Malignancies of the Base of Skull: Treatment Planning, Acute Toxicities, and Preliminary Clinical Outcomes

Purpose: To describe treatment planning techniques and early clinical outcomes in patients treated with spot scanning proton therapy for chordoma or chondrosarcoma of the skull base. Methods and Materials: From June 2010 through August 2011, 15 patients were treated with spot scanning proton therapy for chordoma (n=10) or chondrosarcoma (n=5) at a single institution. Toxicity was prospectively evaluated and scored weekly and at all follow-up visits according to Common Terminology Criteria for Adverse Events, version 3.0. Treatment planning techniques and dosimetric data were recorded and compared with those of passive scattering plans created with clinically applicable dose constraints. Results: Ten patients were treated with single-field-optimized scanning beam plans and 5 with multifield-optimized intensity modulated proton therapy. All but 2 patients received a simultaneous integrated boost as well. The mean prescribed radiation doses were 69.8 Gy (relative biological effectiveness [RBE]; range, 68-70 Gy [RBE]) for chordoma and 68.4 Gy (RBE) (range, 66-70) for chondrosarcoma. In comparison with passive scattering plans, spot scanning plans demonstrated improved high-dose conformality and sparing of temporal lobes and brainstem. Clinically, the most common acute toxicities included fatigue (grade 2 for 2 patients, grade 1 for 8 patients) and nausea (grade 2 for 2 patients, grade 1 for 6 patients). No toxicities of grades 3 to 5 were recorded. At a median follow-up time of 27 months (range, 13-42 months), 1 patient had experienced local recurrence and a second developed distant metastatic disease. Two patients had magnetic resonance imaging-documented temporal lobe changes, and a third patient developed facial numbness. No other subacute or late effects were recorded. Conclusions: In comparison to passive scattering, treatment plans for spot scanning proton therapy displayed improved high-dose conformality. Clinically, the treatment was well tolerated, and with short-term follow-up, disease control rates and toxicity profiles were favorable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation of a volumetric modulated arc therapy treatment planning solution for kidney and adrenal stereotactic body radiation therapy

To develop a volumetric modulated arc therapy (VMAT) treatment planning solution in the treatment of primary renal cell carcinoma and oligometastatic adrenal lesions with stereotactic body radiation therapy. Single-arc VMAT plans (n = 5) were compared with clinically delivered step-and-shoot intensity-modulated radiotherapy (IMRT) with planning target volume coverage normalized between techniques. Target volume conformity, organ-at-risk (OAR) dose, treatment time, and monitor units were compared. A VMAT planning solution, created from a combination of arc settings and optimization constraints, auto-generated treatment plans in a single optimization. The treatment planning solution was evaluated on 15 consecutive patients receiving kidney and adrenal stereotactic body radiation therapy. Treatment time was reduced from 13.0 ± 2.6 to 4.0 ± 0.9 minutes for IMRT and VMAT, respectively. The VMAT planning solution generated treatment plans with increased target homogeneity, improved 95% conformity index, and a reduced maximum point dose to nearby OARs but with increased intermediate dose to distant OARs. The conformity of the 95% isodose improved from 1.32 ± 0.39 to 1.12 ± 0.05 for IMRT and VMAT treatment plans, respectively. Evaluation of the planning solution showed clinically acceptable dose distributions for 13 of 15 cases with tight conformity of the prescription isodose to the planning target volume of 1.07 ± 0.04, delivering minimal dose to OARs. The introduction of a stereotactic body radiation therapy VMAT treatment planning solution improves the efficiency of planning and delivery time, producing treatment plans of comparable or superior quality to IMRT in the case of primary renal cell carcinoma and oligometastatic adrenal lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗