Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical detectability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Noncontact acousto-ultrasonics using laser generation and laser interferometric detection

A compact, portable fiber-optic heterodyne interferometer designed to detect out-of-plane motion on surfaces is described. The interferometer provides a linear output for displacements over a broad frequency range and can be used for ultrasonic, acoustic emission, and acousto-ultrasonic (AU) testing. The interferometer in conjunction with a compact pulsed Nd:YAG laser represents a noncontact testing system. This system was tested to determine its usefulness for the AU technique. The results obtained show that replacement of conventional piezoelectric transducers (PZT) with a laser generation/detection system make it possible to carry out noncontact AU measurements. The waveforms recorded were 5 MHZ PZT-generated ultrasound propagating through an aluminum block, detection of the acoustic emission event, and laser AU waveforms from graphite-epoxy laminates and a filament-wound composite.

Green, Robert E., Jr.↗

Detection Performance of Upgraded "Polished Panel" Optical Receiver Concept on the Deep-Space Network's 34 Meter Research Antenna

The development and demonstration of a "polished panel" optical receiver concept on the 34 meter research antenna of the Deep Space Network (DSN) has been the subject of recent papers. This concept would enable simultaneous reception of optical and microwave signals by retaining the original shape of the main reflector for microwave reception, but with the aluminum panels polished to high reflectivity to enable focusing of optical signal energy as well. A test setup has been installed on the DSN's 34 meter research antenna at Deep Space Station 13 (DSS-13) of NASA's Goldstone Communications Complex in California, and preliminary experimental results have been obtained. This paper describes the results of our latest efforts to improve the point-spread function (PSF) generated by a custom polished panel, in an attempt to reduce the dimensions of the PSF, thus enabling more precise tracking and improved detection performance. The design of the new mechanical support structure and its operation are described, and the results quantified in terms of improvements in collected signal energy and optical communications performance, based on data obtained while tracking the planet Jupiter with the 34 meter research antenna at DSS-13.

photon-bucket receiver↗

Soft X-ray pulsations from SS Cygni

Pulsed soft X-rays (0.1 to 0.5 keV) with a period of 9 sec and a pulsed fraction that varies between 0 and 100% were detected from the dwarf nova SS Cygni at the peak of an optical outburst. This detection confirms for the first time the supposed high energy origin of optical pulsations seen in erupting dwarf novae. The pulse shape is remarkably sinusoidal for such a large-amplitude oscillation. The X-ray pulsation observed in this outburst is not coherent, in contrast to previous claims for the related optical oscillations.

Cordova, F. A.↗

Improvements in Night-Time Low Cloud Detection and MODIS-Style Cloud Optical Properties from MSG SEVIRI

The MODIS cloud optical properties algorithm (MOD06IMYD06 for Terra and Aqua MODIS, respectively) slated for production in Data Collection 6 has been adapted to execute using available channels on MSG SEVIRI. Available MODIS-style retrievals include IR Window-derived cloud top properties, using the new Collection 6 cloud top properties algorithm, cloud optical thickness from VISINIR bands, cloud effective radius from 1.6 and 3.7Jlm and cloud ice/water path. We also provide pixel-level uncertainty estimate for successful retrievals. It was found that at nighttime the SEVIRI cloud mask tends to report unnaturally low cloud fraction for marine stratocumulus clouds. A correction algorithm that improves detection of such clouds has been developed. We will discuss the improvements to nighttime low cloud detection for SEVIRI and show examples and comparisons with MODIS and CALIPSO. We will also show examples of MODIS-style pixel-level (Level-2) cloud retrievals for SEVIRI with comparisons to MODIS.

Wind, Galina (Gala)↗

Optical spectroscopic tools for standoff uranium detection

Rapid and standoff analysis of uranium is important for many applications. We present the recent advances in standoff detection of uranium using emission and laser-induced fluorescence spectroscopy in conjunction with ultrafast laser filament ablation-based solid sampling.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Space Shuttle Main Engine: Advanced Health Monitoring System

The main gola of the Space Shuttle Main Engine (SSME) Advanced Health Management system is to improve flight safety. To this end the new SSME has robust new components to improve the operating margen and operability. The features of the current SSME health monitoring system, include automated checkouts, closed loop redundant control system, catastropic failure mitigation, fail operational/ fail-safe algorithms, and post flight data and inspection trend analysis. The features of the advanced health monitoring system include: a real time vibration monitor system, a linear engine model, and an optical plume anomaly detection system. Since vibration is a fundamental measure of SSME turbopump health, it stands to reason that monitoring the vibration, will give some idea of the health of the turbopumps. However, how is it possible to avoid shutdown, when it is not necessary. A sensor algorithm has been developed which has been exposed to over 400 test cases in order to evaluate the logic. The optical plume anomaly detection (OPAD) has been developed to be a sensitive monitor of engine wear, erosion, and breakage.

Singer, Chirs↗

Renewal: Coherent control of spin states in organic electronics – discovery and investigation of complex room-temperature magnetic quantum excitations

In the course of four funding cycles of this project, its research focused on the exploration and understanding of spin-dependent electronic processes in organic semiconductors. It aimed to investigate the potential of harnessing the spin degree of freedom in organic materials for various applications such as spin electronics, quantum information, sensors, and as well as quantum coherent spin phenomena of charge carrier states in organic semiconductors, with the aim to develop room-temperature-based quantum applications. Specifically, the project aimed to: Apply new diagnostic tools, i.e. spin spectroscopy techniques, for paramagnetic charge carrier states in organic semiconductors, based on coherent control with pulsed electron spin resonance to understand spin relaxation and spin mixing mechanisms in organic semiconductor materials and devices such as OLEDs. Explore the nature of charge carrier spin-coupling and pathways for its manipulation to control the physical behaviors of these materials. This involves investigating spin interactions through materials structure, composition, morphological dependencies, isotopic effects, and externally applied electric and magnetic fields, with the goal to manipulate electrical and optical material properties by adjusting spin-orbit, spin-dipolar, spin-exchange, as well as spin-hyperfine interactions to open up this materials class for new applications. Study spin-dependent charge carrier transport and recombination and how these observables are governed by spin-propagation, especially coherent spin propagation as well as collective spin-effects such as the spin-Dicke effect and resonant multi-photon magnetic dipole transitions. The project utilized pulsed electrically detected magnetic resonance (pEDMR) and pulsed optically detected magnetic resonance (pODMR) techniques over a wide frequency range. These techniques enabled the observation and quantification of various spin-spin coupling types, including spin-exchange, spin-dipolar, hyperfine, and spin-orbit interactions. The project will leverage low- to mid-frequency pEDMR/pODMR facilities and collaboration with the National High Magnetic Field Laboratory.

36 MATERIALS SCIENCE↗

Current status of the Explosive Transient Camera

The current configuration and performance of the Explosive Transient Camera (ETC), a wide-field sky monitor capable of detecting short-timescale optical transients, are briefly reviewed, as are plans for future improvements. The primary objective of the ETC is to detect an optical transient that is spatially and temporally coincident with a gamma-ray burster. However, the ETC is sensitive to all sources of short-timescale optical transients and will conduct a systematic survey of the night sky for all optical transients. Results of preliminary observations of the night sky conducted since January 1991 are summarized, and long-term variability searches with the ETC are discussed.

Vanderspek, Roland↗

Chemical-Sensing Cables Detect Potential Threats

Intelligent Optical Systems Inc. (IOS) completed Phase I and II Small Business Innovation Research (SBIR) contracts with NASA's Langley Research Center to develop moisture- and pH-sensitive sensors to detect corrosion or pre-corrosive conditions, warning of potentially dangerous conditions before significant structural damage occurs. This new type of sensor uses a specially manufactured optical fiber whose entire length is chemically sensitive, changing color in response to contact with its target, and demonstrated to detect potentially corrosive moisture incursions to within 2 cm. After completing the work with NASA, the company received a Defense Advanced Research Projects Agency (DARPA) Phase III SBIR to develop the sensors further for detecting chemical warfare agents, for which they proved just as successful. The company then worked with the U.S. Department of Defense (DoD) to fine tune the sensors for detecting potential threats, such as toxic industrial compounds and nerve agents. In addition to the work with government agencies, Intelligent Optical Systems has sold the chemically sensitive fiber optic cables to major automotive and aerospace companies, who are finding a variety of uses for the devices. Marketed under the brand name Distributed Intrinsic Chemical Agent Sensing and Transmission (DICAST), these unique continuous-cable fiber optic chemical sensors can serve in a variety of applications: Corrosive-condition monitoring, aiding experimentation with nontraditional power sources, as an economical means of detecting chemical release in large facilities, as an inexpensive "alarm" systems to alert the user to a change in the chemical environment anywhere along the cable, or in distance-resolved optical time domain reflectometry systems to provide detailed profiles of chemical concentration versus length.

Source record↗

A Non-Intrusive Optical (NIO) Method to Measure Optical Errors of in-situ Heliostats in Utility-Scale Power Tower Plants: Detecting Uncertainties in Heliostat Geometry

Heliostat optical errors can account for significant losses in efficiency of power tower concentrating solar power (CSP) plants. Accurately measuring heliostat optical errors can help to improve plant performance. A Non-Intrusive Optical (NIO) method has been developed to efficiently measure heliostat optical errors from UAS collected images of the mirror surface reflection [1]–[3]. In some cases, plant data of heliostat geometry can be incomplete or contain inaccuracies, in which case field collected data can be used to detect and correct uncertainties, which is valuable information for plant operators.

Mitchell, Rebecca↗

Stray Light Analysis

Based on a Small Business Innovation Research contract from the Jet Propulsion Laboratory, TracePro is state-of-the-art interactive software created by Lambda Research Corporation to detect stray light in optical systems. An image can be ruined by incidental light in an optical system. To maintain image excellence from an optical system, stray light must be detected and eliminated. TracePro accounts for absorption, specular reflection and refraction, scattering and aperture diffraction of light. Output from the software consists of spatial irradiance plots and angular radiance plots. Results can be viewed as contour maps or as ray histories in tabular form. TracePro is adept at modeling solids such as lenses, baffles, light pipes, integrating spheres, non-imaging concentrators, and complete illumination systems. The firm's customer base includes Lockheed Martin, Samsung Electronics and other manufacturing, optical, aerospace, and educational companies worldwide.

Source record↗

CROCUS Forward Scatter Disdrometer Data at Argonne National Laboratory Prairie Site

The Vaisala FD70 is a multi-parameter present weather and visibility sensor designed to measure precipitation type, intensity, and visibility with high accuracy in diverse environmental conditions. It uses a combination of forward-scatter measurement and optical disdrometer technologies to detect drop size, fall speeds, and optical properties, enabling the classification of various precipitation types such as rain, snow, sleet, and freezing rain along is visibility estimates. The FD70 provides quantitative estimates of liquid-equivalent precipitation rate and meteorological optical range (MOR), supporting applications in meteorological research, aviation, and road weather monitoring. These measurements are collected at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20 acre prairie site at Argonne National Lab, located in Lemont, IL. Data is available in netcdf format. Each file contains one second interval data, for approximately 24 hrs each day. File naming convention includes the project (CROCUS), location (ATMOS), instrument name, data level (raw, a1), and date (year, month, day).

54 ENVIRONMENTAL SCIENCES↗

Organic photodetector with built-in amplification for the detection of visible light with low optical power

We report on an organic-based photodetector that integrates a dual-gate organic thin-film transistor (DG-OTFT) with an organic photodiode (OPD) to produce a device with a high effective responsivity at low optical power and video-rate compatible response. In this device, the OPD operates in photovoltaic mode, instead of the commonly used photoconductive mode, to modulate one of the gate voltages of the DG-OTFT. Effective responsivity values of 10 A W –1 are measured at optical power values lower than 10 nW at 635 nm. Here, modeling of the operation of this new photodetector suggests that effective responsivity values up to 10 5 A W –1 can be achieved at optical powers of 1 nW using current printing technology and state-of-the-art organic semiconductors.

47 OTHER INSTRUMENTATION↗

Angularly quantized spin rotations in hexagonal LuMnO 3

Optical control of the spin degree of freedom is often desired in application of the spin technology. Here we report spin-rotational excitations observed through inelastic light scattering of the hexagonal LuMnO 3 in the antiferromagnetically (AFM) ordered state. We propose a model based on the spin–spin interaction Hamiltonian associated with the spin rotation of the Mn ions, and find that the spin rotations are angularly quantized by 60°, 120°, and 180°. Angular quantization is considered to be a consequence of the symmetry of the triangular lattice of the Mn-ion plane in the hexagonal LuMnO 3 . These angularly-quantized spin excitations may be pictured as isolated flat bubbles in the sea of the ground state, which may lead to high-density information storage if applied to spin devices. Optically pumped and detected spin-excitation bubbles would bring about the advanced technology of optical control of the spin degree of freedom in multiferroic materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of heterodyne detection of radio frequency waves using phase contrast imaging

An upgrade to the DIII–D phase contrast imaging (PCI) diagnostic for detection of radio frequency waves has been implemented using low-noise optical heterodyning. Electro-optical modulation allows detection of waves with frequencies up to 500 MHz with wide flexibility restricted only by the driver electronics, with continuous adjustability up to 100 MHz and fixed frequency drivers needed for higher frequencies. The PCI diagnostic images the line-integrated plasma density fluctuations and provides absolutely calibrated measurements with good wavenumber resolution.

Rost, J. C. [Massachusetts Institute of Technology↗

Detection of effect of deposits on optical windows of pyrometer measurements

Temperatures measurements in an enclosed test chamber are more accurate when the reflectivity of the inner coated surface is compared to the outer clean surface of an optical window. Temperature readings are corrected by correlating the reflectivity of the deposits with their effect on the temperature measurement.

Cipolone, P.↗

Detection of neutral hydrogen emission and optical nebulosity in the low redshift QSO 0351+026

Spectroscopy, photometry, and imaging of the X-ray source 0351+026 are consistent with an active nucleus with the spectrum of a QSO or type I Seyfert, embedded in a low luminosity host galaxy of colors similar to M31. The H I observations reveal a tremendous amount of neutral gas associated with the system, M(H I)/L(B) = 15 in solar units, and the velocity width of the feature is 1500 km/s. Both parameters substantially exceed those seen in other galaxies and interacting pairs. The unique H I properties of the system combined with the presence of an active nucleus with QSO-like features is a tantalizing, but poorly understood, combination. At slightly larger redshift and thus inferior angular scale, this object would be indistinguishable from a QSO in its optical and X-ray characteristics.

Bothun, G. D.↗