Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operating conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Assessment of wind power scenario creation methods for stochastic power systems operations

Probabilistic scenarios of renewable energy production, such as wind, have been gaining popularity for use in stochastic variants of power systems operations scheduling problems, allowing for optimal decision-making under uncertainty. The quality of the scenarios has a direct impact on the value of the resulting decisions, but until now, methods for creating scenarios have not been compared under realistic operational conditions. Here, we compare the quality of scenario sets created using three different methods, based on a simulated re-enactment of stochastic day-ahead unit commitment and subsequent dispatch for a realistic test system. We create scenarios using a dataset of forecasted and actual wind power values, scaled to evaluate the effects of increasing wind penetration levels. We show that the choice of scenario set can significantly impact system operating cost, renewable energy use, and the ability of the system to meet demand. This result has implications for the ability of system operators to efficiently integrate renewable production into their day-ahead planning, highlighting the need for the use of performance-based assessments for scenario evaluation.

17 WIND ENERGY↗

Design and evaluation of a dilute flow particle-to-air heat exchanger for energy storage applications

The use of inert and redox-active particles for high-temperature energy storage requires the development of components that can efficiently transfer energy to high-pressure working fluids like supercritical carbon dioxide (sCO 2 ). Dilute flow reactors can enable high working fluid outlet temperatures and minimal parasitic losses compared to moving packed bed and fluidized bed reactors. This research uses both computational and experimental methods to explore the design trade-offs and practical challenges of a novel component for transferring energy from dilute flows of hot, reduced metal oxide (MO x ) particles to sCO 2 in tubes. A discretized thermal resistance network model, which accounts for particle hydrodynamics, multi-mode heat transfer, and reaction equilibrium, guides the design of a prototype device. This device is experimentally tested with a surrogate heat transfer fluids and inert particle temperatures up to 400°C and a heat duty exceeding 1 kW. The data are used to validate the thermal hydraulic sub-models, allowing for the simulation of reacting particle scenarios. Under nominal design conditions, the flow rate of reactive particles is predicted to be 30% lower than that of inert particles for the same energy recovered, with over 70% of the stored particle energy transferred to the sCO 2 . Furthermore, these findings can inform the design of more efficient energy recovery reactors for particle-based systems and can be integrated into system-level concentrated solar power models with thermal storage to optimize operating conditions.

14 SOLAR ENERGY↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing Power Reclamation of Micro Hydro Turbines in WWTPs Aeration Basins

Abstract This study investigates the optimum operating conditions and design configurations that can optimize the power reclaimed by small hydro turbines derived by the rising water-bubble current. The rising current is generated by the compressed air introduced by the diffusers at the bottom of aeration basins of Wastewater Treatment Plants (WWTPs). While optimizing the power production, the standard oxygen transfer efficiency (SOTE) is monitored since it is a significant parameter that cannot be sacrificed in the operation of WWTPs. Using one set of turbine blades, it was found out that the highest velocity is obtained in the upper half of the water column (70% - 80%). In contrast, the lowest velocities were obtained just above the air diffuser and at the water surface. Testing started with using a single turbine (ST) to determine the location of the optimum power reclaimed at each tested airflow (1.18, 1.42, 1.65, and 1.89 L/s). Then using double turbine (DT) and triple turbine (TT) to compare their performance to the ST’s maximum power increased power reclamation. The maximum percentage of increase in power reclamation for DT is 19.59%, while it is 20.24% in the case of TT. At a commonly used airflow in WWTPs (1.42 L/s), the optimum configurations of DTs and TTs were selected to investigate the effect of having the proposed setup on the SOTE. For membrane diffusers, DTs and TTs limited the dispersion of the air bubbles in the tank, therefore, reducing the SOTE (8.3% for DT and 3.7% for the TT). The ceramic and sharp-nub diffusers were also tested versus rubber membrane ones to determine the effect of using the ceramic and sharp-nub diffusers on the power reclamation and SOTE. Ceramic diffusers neither achieve higher power reclamation than the membrane nor increases the SOTE. In contrast, sharp-nub diffusers increase the SOTE for all configurations compared to membranes, but this came into account of power reclamation, where sharp-nub diffusers cause a DT and a TT to produce less power than ST does.

Energy & Fuels↗

Legacy Metallic Fuel U(Pu)Zr Data Qualification

The Metallic Fuels Irradiation and Physics Database (FIPD) is an organized collection of legacy metallic fuel U(Pu)Zr data, measurements, and reactor conditions from the Experimental Breeder Reactor II (EBR-II) and the Fast Flux Test Facility (FFTF). The database provides a wealth of information and is easily accessed and utilized by the U.S. nuclear industry and the Nuclear Regulatory Commission (NRC). The database contains three categories of data. The first category covers fuel pin fabrication specifications, including fuel slug diameter and length, cladding diameter, smeared density, etc. The second consists of operational conditions, which include axial distributions of power, temperature, fluence, burnup, isotopic density, etc. The third category contains post-irradiation examination (PIE) results, largely collected at facilities now part of the Idaho National Laboratory (INL), formerly part of Argonne National Laboratory -West (ANL-W) and at the Alpha-Gamma Hot Cell Facility (AGHCF) at Argonne National Laboratory, comprising fission gas release and chemistry analysis, profilometry measurements, neutron radiography data, etc. All these data have been organized and preserved in FIPD.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-situ thermophysical measurement of flowing molten chloride salt using modulated photothermal radiometry

Molten salts are leading candidates for high-temperature heat transfer fluids (HTFs) for thermal energy storage and conversion systems in concentrated solar power (CSP) and nuclear energy power plants. The ability to probe molten salt thermal transport properties in both stationary and flowing status is important for the evaluation of their heat transfer performance under realistic operational conditions, including the temperature range and potential degradation due to corrosion and contamination. However, accurate thermal transport properties are usually challenging to obtain even for stagnant molten salts due to different sources of errors from convection, radiation, and corrosion, let alone at flowing status. To the best of authors’ knowledge, there is no available in-situ technique for measuring flowing molten salt thermal conductivity. Here, we report the first in-situ flowing molten salt thermal conductivity measurement using modulated photothermal radiometry (MPR). We could successfully perform the first in-situ thermal conductivity measurement of flowing molten NaCl-KCl-MgCl 2 in the typical operating temperature (520 and 580 °C) with flow velocities ranging from around 0.3 to 1.0 m s -1 . The relative change of the molten salt thermal conductivity was measured. Gnielinski’s correlation was also used to estimate the heat transfer coefficient h of the flowing NaCl-KCl-MgCl 2 in the given experimental condition. Furthermore, the work showed the potential of the MPR technique serving as an in-situ diagnostics tool to evaluate the heat transfer performance of flowing molten salts and other high-temperature HTFs.

14 SOLAR ENERGY↗

HEMP Testing of Substation Yard Circuit Breaker Control and Protective Relay Circuits

There are concerns about the effects of High-Altitude Electromagnetic Pulses (HEMP) on the electric power grid. Activities to date tested and analyzed vulnerability of digital protective relays (DPRs) used in power substations, but the effect of HEMP on the greater substation environment is not well known. This work establishes a method of testing the vulnerability of circuit breaker control and protective relay circuits to the radiated E1 pulse associated with HEMP based on coupling to the cables in a substation yard. Two DPRs from Schweitzer Engineering Laboratories, Inc. were independently tested. The test setup also included a typical cable in a substation yard with return plane to emulate the ground grid and other ground conductors near the yard cable, cabinetry housing the installed DPRs, station battery and battery charger, terminal block elements, and a breaker simulator to emulate a substation yard configuration. The DPRs were powered from the station battery and the transformer inputs energized with a three-phase source to maintain typical operating conditions during the tests. Vulnerability testing consisted of a conducted E1 pulse injected into the center of the yard cable of the DPR circuits. Current measurements on the yard cable and DPR inputs indicated significant attenuation of the conducted pulse arriving at the control house equipment from the emulated substation yard. This reduction was quantified with respect to the equivalent open-circuit voltage on the yard cable. No equipment damage or undesired operation occurred on the tested circuits for values below 180 kV, which is significantly higher than the anticipated coupling to a substation yard cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Condensed Phase Guerbet Reactions of Ethanol/Isoamyl Alcohol Mixtures

The self-condensation and cross-condensation reactions of ethanol and isoamyl alcohol are examined to better understand the potential routes to value-added byproducts from fuel ethanol production. Reactions have been carried out in both batch autoclave and continuous condensed-phase reactors using a lanthanum-promoted, alumina-supported nickel catalyst at near-critical condensed phase conditions. Analysis of multiple candidate kinetic models led to a Langmuir–Hinshelwood rate expression that is first-order in alcohol with water as the strongly adsorbed species. This model provides the best fit of data from both batch and continuous reactor experiments. Activation energies for primary condensation reactions increase as carbon chain lengths increase. Selectivities to higher alcohols of 94% and 87% for ethanol and isoamyl alcohol, respectively, were observed at different operating conditions.

Nezam, Iman (ORCID:0000000277598069)↗

DEVELOPMENT OF OIL FREE CENTRIFUGAL BLOWER AS ENABLING TECHNOLOGY FOR SOLID OXIDE FUEL CELL ANODE GAS RECYCLING

Broad commercialization of solid oxide fuel cells (SOFCs), requires anode offgas recycle blowers (AORB) that are specifically designed for handling the challenging operating conditions presented by the SOFC process gases. Otherwise, they can be susceptible to frequent maintenance, low reliability, and short life. This work presents details of the development and testing of an oil-free, low cost centrifugal AORB based on compliant foil bearing (CFB) technology for support of a 100 kW solid oxide fuel cell power plant. The advantages of this novel technology are discussed, particularly its long life and maintenance-free operation, which are derived from the use of CFBs. Also included are preliminary techno-economic analysis considerations for cost-effective deployment of the technology.

03 NATURAL GAS↗

Experimental Characterization of an Additively Manufactured Inconel 718 Heat Exchanger for High-Temperature Applications

This work presents the experimental results of a novel, air-to-air, additively manufactured manifold-microchannel heat exchanger with straight fins on both sides. The heat exchanger was made of Inconel 718 using a direct metal laser sintering technique. The overall core size of the heat exchanger was 94 mm × 87.6 mm × 94.4 mm, with a fin thickness of 0.220 mm on both the hot and cold sides. The heat exchanger was tested with pressurized nitrogen gas at 300 °C and 340 kPa for the hot side, while air at an ambient condition was used for the cold side. An overall heat transfer of 276 W/m2K was obtained for Reynolds number values of 132 and 79 for the cold and hot sides, respectively. A gravimetric heat transfer density (Q/m∆T) of 4.7–6.7 W/kgK and a volumetric heat transfer density (Q/V∆T) of 6.9–9.8 kW/m3K were recorded for this heat exchanger with a coefficient of performance value that varied from 42 to 52 over the operating conditions studied here. The experimental pressure drop results were within 10% of the numerical values, while the corresponding heat transfer results were within 17% of the numerical results, mainly due to imperfections in the fabrication process. Despite this penalty, the performance of the tested heat exchanger was superior to the conventional plate-fin heat exchangers: more than 60% of improvements in both gravimetric and volumetric heat transfer densities were recorded for the entire range of experimental data.

42 ENGINEERING↗

An analysis of fluff formation in metallic fuel via data analyzes from EBR-II experiments and BISON fuel code modeling

During the operation of EBR-II, it was found that a highly porous structure (over 40% area fraction) formed at the top of several fuel columns. Previous work has shown that this structure, designated fluff in this paper, contains a significant fraction of fuel elements (e.g., U and Pu) which could potentially impact neutronics. This work aims in analyzing the formation mechanism of this microstructure so its impact can be incorporated into future metallic fuel modeling codes and algorithms. This paper details a preliminary examination into the formation mechanisms of fluff by performing qualitative and statistical analysis of EBR-II experimental data. Additionally, the operating conditions that have the greatest impact on fluff formation were determined based on this data set. Also, BISON fuel code simulations were used to help postulate potential fluff formation mechanisms. From this analysis it was found that the largest contributors to fluff formation were fuel burnup and composition, with fluff formation exhibiting a roughly linear positive correlation with increasing burnup and a negative correlation with increasing Pu content. It was also found that higher pin operating temperatures decreased fluff formation but only for U-10Zr fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling Air Handling Units to Create a Diverse Fault Dataset for FDD Innovation: Lessons Learned and Recommendations

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault datasets for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling unit and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for the air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, two detailed AHU models, which included the single duct AHU and dual duct AHU developed in the Modelica language and HVACSIM+ were employed to carry out annual simulations of numerous common sensor faults, mechanical faults, and control sequence faults. The fault inclusive data were then validated by comparing fault effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. We report some lessons learnt during the efforts of validating the high volumes of the FDD data sets. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

Insights into the Electrochemical Oxidation and Reduction of Nickel Oxide Surfaces

Surface oxidation/reduction processes, driven by varying electrochemical potentials, can substantially impact catalyst effectiveness and, consequently, electrolyzer performance. Here, this study combines theoretical and experimental approaches to explore the surface redox behavior of nickel oxides, which are cost-effective and efficient catalysts for many electrochemical reactions. Surface Pourbaix diagrams for three different phases of nickel oxides, i.e., nickel hydroxide (Ni(OH) 2 ), nickel oxyhydroxide (NiOOH), and nickel dioxide (NiO 2 ), were constructed using density functional theory-based simulations. Various experimental methods, including cyclic voltammetry, in situ Raman spectroscopy, and electrochemical titration, were employed to probe the surface redox processes of nickel oxide thin films. Our findings indicate that the ABAB stacking sequence of Ni(OH) 2 lacks stability under oxidizing conditions to host the surface oxidation (deprotonation) events, while the AABBCC stacking sequence of NiOOH is energetically favorable due to the presence of interlayer hydrogen bonding. Rapid charge transfer facilitated by interlayer hydrogen bonding accounts for the higher reactivity of partially oxidized/reduced NiOOH (001) surfaces compared to Ni(OH) 2 (001) and NiO 2 (001) surfaces with the same stoichiometry, where interlayer hydrogen bonding is absent. Insights presented in this work can offer guidelines for optimizing operational conditions and tailoring the surface structures and oxidation states of nickel oxides to enhance performance in applications such as electrocatalysis and supercapacitors.

36 MATERIALS SCIENCE↗

Numerical Investigation of Butterfly Valve Performance in Variable Valve Sizes, Positions and Flow Regimes

Reliability and efficiency of valves are necessary for precise control and sufficient heat-flow to heat application plants for the integrated energy systems of nuclear power plants (NPPs). Strategic Management Analysis Requirement and Technology (SMART) valves’ ability to control flow and assess environmental parameters stands out for these requirements. Their ability to sustain the downstream flow rate, prevent reverse flow, and maintain pressure in the heat transport loop is much more efficient with the integration of sensors and intelligent algorithms. For assessing valve performance and monitoring, mechanical design and operating conditions are two important parameters. In this study, the butterfly valves of three different sizes are simulated with water and steam using STAR-CCM+ in various flow regimes and positions to analyze performance parameters to strategize an automated control system for efficiently balancing the heat–transport network. Also, flow behavior is studied using velocity and pressure fields for valve–body geometry optimization. It can be observed, through performance parameters, that the valves are suitable for operation between 30° and 90° positions with significantly low loss coefficients and high flow coefficients, and the performance parameters follow a certain pattern in both water and steam flow in each scenario.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bayesian optimization of dynamic Ce( III ) electrooxidation

Abstract Cerium(III/IV) is a redox couple with promising applications in redox flow batteries and redox‐mediated water electrolyzers, but due to its high oxidation potential, parasitic oxygen evolution can occur and decrease the Faradaic efficiency (FE) of the oxidation reaction. Dynamic potential dosing can help balance the transport limitations and the electrooxidation rates, allowing for control over the cerium(III) concentration near the electrode, enhancing FE. Due to the large number of possible pulsing operating conditions, Bayesian optimization (BO) was used to rapidly identify the optimal potential pulses. With an active pulse voltage of 2.5 V vs. Ag/AgCl, the maximum FE achieved was 0.91 (active pulse time = 5 ms, resting pulse time = 136 ms), underscoring the need for long inactive times for cerium(III) diffusion to the electrode. Furthermore, a multiobjective BO was performed to identify optimal trade‐offs between FE and the partial current density to achieve improvements over constant current operation.

Engineering↗

A 100+ RON Gasoline Blendstock for High Efficiency, Low Emission Vehicles Engines - CRADA 493 (Final Report)

This study aimed at demonstrating production of a 100+RON gasoline fraction from a linear olefins feedstock to help improve further the viability and flexibility of the Pacific Northwest National Laboratory/ LanzaTech alcohol-to-jet (ATJ) patented process that converts ethanol from LanzaTech’s syngas fermentation process to low aromatic jet-range iso-paraffins. To achieve a high RON gasoline and ultimately a 100+RON, the technical approach consisted of converting the linear olefins into an iso-olefins rich mixture and then oligomerizing the iso-olefins rich mixture into high RON compounds in a single bed loaded with an acid catalyst that allows conversion at low reaction temperature. Three families of acid catalysts labeled as type A, B and C were investigated for the single-bed conversion of linear olefins into high RON gasoline range compounds. The effects of the nature of the catalyst, acid sites concentration and operating conditions were investigated. Fuel properties measurements and engine testing were conducted for the most promising catalyst. For type A catalysts, we demonstrated that the conversion increases with the increase of the Brönsted acid site concentration and that lower reaction temperature favors the formation of desired highly branched compounds. The highest dRON obtained with type A catalyst was equal to 94 (from NMR and IQT). Type B catalysts appear very effective for producing dimethyl-olefins compounds when operating at low reaction temperature (i.e., < 100°C). The highest dRON obtained with type B catalyst was equal to 92. The results suggest that type B catalysts are less favorable to internal conversion of linear olefins into iso-olefins compared to type A catalysts which leads to the formation of a gasoline blendstock with a lower dRON. A Type C catalyst that is less commonly used for production of gasoline range compounds from linear olefins was investigated due to its ability to favor conversion of linear olefins into iso-olefins. Compared to type A and type B catalyst, type C favors the formation of highly branched compounds (i.e., with 3+ methyl groups) in the gasoline range. Indeed, a gasoline blendstock containing about 33 wt.% of highly branched compounds was produced with type C catalyst while maintaining a high linear olefins conversion (i.e., 70%). A large quantity of this gasoline blendstock was produced and fuel properties measurements including engine testing for Research Octane Number (RON), Motor Octane Number (MON) and octane sensitivity (S) were conducted. A high RON = 97, MON = 82.7, S =14.3, AKI = 90 and HoV = 334.1kJ/kg were measured. While a RON of 100 was not achieved, the fuel properties of the gasoline blendstock are very acceptable as compared to current premium gasoline. Overall, these results highlight the potential for producing a high RON/ premium gasoline blendstock starting from a linear olefins feedstock.

02 PETROLEUM↗

Ethanol-fueled metal supported solid oxide fuel cells with a high entropy alloy internal reforming catalyst

High-performance metal supported solid oxide fuel cells (MS-SOFC) with an integrated high entropy alloy (HEA) internal reforming catalyst (IRC) are demonstrated for transportation applications using ethanol and methanol as fuels. Addition of the HEA IRC dramatically improves cell performance and stability when using ethanol/water blend fuel. Absence of carbon deposition predicted by thermodynamic calculations is confirmed by Raman spectroscopy analysis of posttest anodes. Optimal catalyst processing (deposition technique, loading, firing temperature) and cell operation conditions (flow rates, temperature, fuel compositions) are explored. Infiltrated HEA reforming catalyst provides a highly porous structure and low catalyst loading (6 mg cm –2 ). The designed structure and catalysts achieve small mass transport resistances in the fuel electrode (26.2 s m –1 ) and oxygen electrode (41.6 s m –1 ). The best ethanol concentration (60:40 v% ethanol: water) provides 0.83 W cm –1 at 700 °C, without carbon deposition. The ethanol-fueled MS-SOFC is operated for 500 h, including five thermal cycles. As a result, cell evolution is similar to that reported previously for hydrogen fuel; nickel aggregation and chromia deposition were the major observed changes, and carbon formation can be avoided even after long-term operation.

30 DIRECT ENERGY CONVERSION↗