Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “online”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Morphotype-resolved characterization of microalgal communities in a nutrient recovery process with ARTiMiS flow imaging microscopy

Microalgae-driven nutrient recovery represents a promising technology for phosphorus removal from wastewater while simultaneously generating biomass that can be valorized to offset treatment costs. As full-scale processes come online, system parameters including biomass composition must be carefully monitored to optimize performance and prevent culture crashes. In this study, flow imaging microscopy (FIM) was leveraged to characterize microalgal community composition in near real-time at a full-scale municipal wastewater treatment plant (WWTP) in Wisconsin, USA, and population and morphotype dynamics were examined to identify relationships between water chemistry, biomass composition, and system performance. Two FIM technologies, FlowCam and ARTiMiS, were evaluated as monitoring tools. ARTiMiS provided a more accurate estimate of total system biomass, and estimates derived from particle area as a proxy for biovolume yielded better approximations than particle counts. Deep learning classification models trained on annotated image libraries demonstrated equivalent performance between FlowCam and ARTiMiS, and convolutional neural network (CNN) classifiers proved significantly more accurate when compared to feature table-based dense neural network (DNN) models. Across a two-year study period, Scenedesmus spp. appeared most important for phosphorus removal, and were negatively impacted by elevated temperatures and increase in nitrite/nitrate concentrations. Chlorella and Monoraphidium also played an important role in phosphorus removal. For both Scenedesmus and Chlorella, smaller morphological types were more often associated with better system performance, whereas larger morphotypes likely associated with stress response(s) correlated with poor phosphorus recovery rates. Furthermore, these results demonstrate the potential of FIM as a critical technology for high-resolution characterization of industrial microalgal processes.

59 BASIC BIOLOGICAL SCIENCES↗

Mast1 mediates radiation-induced gastric injury via the P38 MAPK pathway

Radiation-induced gastric injury is a serious adverse effect and reduces the efficacy of radiotherapy treatment. However, the mechanisms underlying radiation-induced stomach injury remain unclear. Here, mouse stomach and gastric epithelial cells were irradiated with different doses of X-ray radiation. The results showed that radiation induced gastric injury in vivo and in vitro. Differentially expressed functional mRNAs in irradiation-induced gastric tissues were screened from the Gene Expression Omnibus (GEO) database. We found that the expression of microtubule-associated serine/threonine kinase 1 (Mast1) was downregulated in mouse gastric tissues and gastric epithelial cells after irradiation. Furthermore, functional assays showed that knockdown of Mast1 inhibited growth and promoted apoptosis in gastric epithelial cells, while overexpression of Mast1 protected gastric epithelial cells from radiation damage. Mechanistically, Mast1 negatively regulated radiation-induced injury in gastric epithelial cells by inhibiting the activation of P38. The apoptosis caused by knockdown of Mast1 in gastric epithelial cells could be partially reversed by the P38 inhibitor SB203580. Moreover, data from several gastric cancer cell lines and online databases revealed that Mast1 was not involved in the development of gastric cancer. Collectively, our findings demonstrated that Mast1 is essential for radiation-induced gastric injury, providing a promising prognostic and therapeutic target.

60 APPLIED LIFE SCIENCES↗

Reduced Order Modeling conditioned on monitored features for response and error bounds estimation in engineered systems

Reduced Order Models (ROMs) form essential tools across engineering domains by virtue of their function as surrogates for computationally intensive digital twinning simulators. Although purely data-driven methods are available for ROM construction, schemes that allow to retain a portion of the physics tend to enhance the interpretability and generalization of ROMs. However, physics-based techniques can adversely scale when dealing with nonlinear systems that feature parametric dependencies. This study introduces a generative physics-based ROM that is suited for nonlinear systems with parametric dependencies and is additionally able to provide numerical error bounds associated with the respective estimates. A main contribution of this work is the conditioning of these parametric ROMs to features that can be derived from monitoring measurements, feasibly in an online fashion. This is contrary to most existing ROM schemes, which remain restricted to the prescription of the physics-based, and usually a priori unknown, system parameters. Our work utilizes conditional Variational Autoencoders to continuously map the required reduction bases to a feature vector extracted from limited output measurements, while additionally allowing for a probabilistic assessment of the ROM-estimated Quantities of Interest. An auxiliary task using a neural network-based parametrization of suitable probability distributions is introduced to re-establish the link with physical model parameters. We verify the proposed scheme on a series of simulated case studies incorporating effects of geometric and material nonlinearity under parametric dependencies related to system properties and input load characteristics.

Conditional VAEs↗

High-power non-perturbative laser delivery diagnostics at the final focus of 100-TW-class laser pulses

Controlling the delivery of multi-terawatt and petawatt laser pulses to final focus, both in position and angle, is critical to many laser applications such as optical guiding, laser–plasma acceleration, and laser-produced secondary radiation. We present an online, non-destructive laser diagnostic, capable of measuring the transverse position and pointing angle at focus. The diagnostic is based on a unique double-surface-coated wedged-mirror design for the final steering optic in the laser line, producing a witness beam highly correlated with the main beam. By propagating low-power kilohertz pulses to focus, we observed spectra of focus position and pointing angle fluctuations dominated by frequencies below 70 Hz. The setup was also used to characterize the excellent position and pointing angle correlation of the 1 Hz high-power laser pulses to this low-power kilohertz pulse train, opening a promising path to fast non-perturbative feedback concepts even on few-hertz-class high-power laser systems.

47 OTHER INSTRUMENTATION↗

Label-Free Profiling of up to 200 Single-Cell Proteomes per Day Using a Dual-Column Nanoflow Liquid Chromatography Platform

Single-cell proteomics (SCP) has great potential to advance biomedical research and personalized medicine. The sensitivity of such measurements increases with low-flow separations (<100 nL/min) due to improved ionization efficiency, but the time required for sample loading, column washing, and regeneration in these systems can lead to low measurement throughput and inefficient utilization of the mass spectrometer. Herein, we developed a two-column liquid chromatography (LC) system that dramatically increases the throughput of label-free SCP using two parallel subsystems to multiplex sample loading, online desalting, analysis, and column regeneration. The integration of MS1-based feature matching increased proteome coverage when short LC gradients were used. The high-throughput LC system was reproducible between the columns, with a 4% difference in median peptide abundance and a median CV of 18% across 100 replicate analyses of a single-cell-sized peptide standard. An average of 621, 774, 952, and 1622 protein groups were identified with total analysis times of 7, 10, 15, and 30 min, corresponding to a measurement throughput of 206, 144, 96, and 48 samples per day, respectively. When applied to single HeLa cells, we identified nearly 1000 protein groups per cell using 30 min cycles and 660 protein groups per cell for 15 min cycles. Finally, we explored the possibility of measuring cancer therapeutic targets with a pilot study comparing the K562 and Jurkat leukemia cell lines. This work demonstrates the feasibility of high-throughput label-free single-cell proteomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Separation of Unknown Organic–Metal Complexes by Liquid Chromatography–Inductively Coupled Plasma-Mass Spectrometry

Dissolved organic matter (DOM) is widely recognized to control the solubility and reactivity of trace metals in the environment. However, the mechanisms that govern metal-DOM complexation remain elusive, primarily due to the analytical challenge of fractionating and quantifying metal–organic species within the complex mixture of organic compounds that comprise DOM. Here, we describe a quantitative method for fractionation and element-specific detection of organic–metal complexes using liquid chromatography with online inductively coupled plasma mass spectrometry (LC–ICP-MS). The method implements a post-column compensation gradient to stabilize ICP–MS elemental response across the LC solvent gradient, thereby overcoming a major barrier to achieving quantitative accuracy with LC–ICP-MS. With external calibration and internal standard correction, the method yields concentrations of organic–metal complexes that were consistently within 6% of their true values, regardless of the complex’s elution time. We used the method to evaluate the effects of four stationary phases (C18, phenyl, amide, and pentafluoroylphenyl propyl) on the recovery and separation of environmentally relevant trace metals (Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in Suwannee River Fulvic Acid and Suwannee River Natural Organic Matter. The C18, amide, and phenyl phases generally yielded optimal metal recoveries (>75% for all metals except Pb), with the phenyl phase separating polar species to a greater extent than C18 or amide. We also fractionated organic-bound Fe, Cu, and Ni in oxidized and reduced soils, revealing divergent metal-DOM speciation across soil redox environments. Finally, by enabling quantitative fractionation of DOM-bound metals, our method offers a means for advancing a mechanistic understanding of metal–organic complexation throughout the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Natural Abundance Isotope Ratio Measurements of Organic Molecules Using 21 T FTICR MS

Subtle variations in stable isotope ratios at natural abundance are challenging to measure but can yield critical insights into biological, physical, and geochemical processes. Well established methods, particularly multi-collector, gas-source or plasma isotope ratio mass spectrometry (IRMS) are the gold standard for stable isotope measurement but inherent limitations in these approaches make them ill-suited to determining site-specific and multiply substituted isotopic abundances of all but a few compounds, or to characterizing mixtures or larger intact molecules. Additionally, Fourier transform mass spectrometry (FTMS), namely Orbitrap mass spectrometry, has recently demonstrated the ability to measure natural abundance isotope ratios with chemically informative accuracy and precision. Here, we report the first use of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for the accurate (<1‰) and precise (<1‰ standard error) simultaneous determination of $δ$ 13 C and $δ$ 15 N in caffeine isotopologues and provide a discussion of the critical instrumental parameters necessary to make such measurements. Finally, we report the ability to make these measurements with online liquid chromatography, expanding the ability of this technique to explore mixtures in the future.

07 ISOTOPE AND RADIATION SOURCES↗

Optical 14 C Tracing for Biological and Pharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Laser-based 14 C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR 14 C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level 14 C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample 14 C content by measuring the 14 CO 2 absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of 14 CO 2 . The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10 15 ) 14 C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS 14 C sensor to two applications relevant to 14 C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10 –15 Ci) quantitation of sample 14 C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ~25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO 2 processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through 14 CO 2 sampling scheme. In conclusion, this improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity 14 C tracing in biological, pharmaceutical, and clinical studies.

60 APPLIED LIFE SCIENCES↗

Integration of pH Control into Chi.Bio Reactors and Demonstration with Small-Scale Enzymatic Poly(ethylene terephthalate) Hydrolysis

Small-scale bioreactors that are affordable and accessible would be of major benefit to the research community. In previous work, an open-source, automated bioreactor system was designed to operate up to the 30 mL scale with online optical monitoring, stirring, and temperature control, and this system, dubbed Chi.Bio, is now commercially available at a cost that is typically 1–2 orders of magnitude less than commercial bioreactors. In this work, we further expand the capabilities of the Chi.Bio system by enabling continuous pH monitoring and control through hardware and software modifications. For hardware modifications, we sourced low-cost, commercial pH circuits and made straightforward modifications to the Chi.Bio head plate to enable continuous pH monitoring. For software integration, we introduced closed-loop feedback control of the pH measured inside the Chi.Bio reactors and integrated a pH-control module into the existing Chi.Bio user interface. We demonstrated the utility of pH control through the small-scale depolymerization of the synthetic polyester, poly(ethylene terephthalate) (PET), using a benchmark cutinase enzyme, and compared this to 250 mL bioreactor hydrolysis reactions. The results in terms of PET conversion and rate, measured both by base addition and product release profiles, are statistically equivalent, with the Chi.Bio system allowing for a 20-fold reduction of purified enzyme required relative to the 250 mL bioreactor setup. Through inexpensive modifications, the ability to conduct pH control in Chi.Bio reactors widens the potential slate of biochemical reactions and biological cultivations for study in this system, and may also be adapted for use in other bioreactor platforms.

09 BIOMASS FUELS↗

Leveraging Calibration Transfer Techniques for Remote Monitoring of Samarium and Europium in LiCl Using Laser-Induced Florescence Spectroscopy for Radioisotope Production Applications

Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sustainable H 2 -Rich Syngas Production via Microwave-Assisted vs Conventional Catalysis of Pinewood

Catalytic gasification of biomass is a promising method for producing hydrogen-rich syngas, which is a valuable resource for cleanenergy applications. In this study, microwave-assisted biomass gasification was compared with conventional thermally driven biomass gasification using pinewood as the biomass without the use of external gasifying agents (such as air, steam, and CO 2 ), under non-catalytic and catalytic conditions. The catalysts consisted of either an iron or a nickel catalyst, and the pinewood used as biomass contained 42% oxygen. This comparative analysis explores the differences in reaction chemistry, product yields, and the role of key reactions such as the water gas shift (WGS) reaction, Boudouard reaction, etc. The gas-phase and liquid-phase products were analyzed using online gas chromatography, and the fresh and spent catalysts were analyzed using X-ray diffraction (XRD) techniques. It was found that microwave-assisted gasification offers advantages in terms of enhanced reaction efficiency, catalyst stability, and hydrogen yield. For the microwave-assisted reaction, the gas yield reached 87%, the char yield was 12.1%, and the tar yield was less than 1% (0.793%) at 550 °C. In contrast, thermal-assisted gasification using the same catalyst produced a gas yield of 85.796%, char yield of 11.438%, and higher tar yield of 2.8% at 900 °C. The higher microwave-assisted performance was attributed to faster heating and better control over reaction conditions, higher reaction rates, and more favorable conditions for hydrogen production.

biomass↗

Unsaturated Sulfur Crown Ethers Can Extract Mercury(II) and Show Promise for Future Copernicium(II) Studies: A Combined Experimental and Computational Study

The unsaturated hexathia-18-crown-6 (UHT18C6) molecule was investigated for the extraction of Hg(II) in HCl and HNO3 media. This extractant can be directly compared to the recently studied saturated hexathia-18-crown-6 (HT18C6). The default conformation of the S lone pairs in UHT18C6 is endodentate, where the pocket of the charge density, according to the crystal structures, is oriented toward the center of the ring, which should allow better extraction for Hg(II) compared to the exodentate HT18C6. Batch study experiments showed that Hg(II) had better extraction at low acid molarity (ca. 99% in HCl and ca. 95% in HNO 3 ), while almost no extraction was observed above 0.4 M HCl and 4 M HNO 3 (<5%). Speciation studies were conducted with the goal of delineating a plausible extraction mechanism. Density functional theory calculations including relativistic effects were carried out on both Hg(II)-encapsulated HT18C6 and UHT18C6 complexes to shed light on the binding strength and the nature of bonding. Our calculations offer insights into the extraction mechanism. In addition to Hg(II), calculations were performed on the hypothetical divalent Cn(II) ion, and showed that HT18C6 and UHT18C6 could extract Cn(II). Finally, the extraction kinetics were explored to assess whether this crown can extract the short-lived Cn(II) species in a future online experiment.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Safety moments in chemical safety education.

Chemical safety education is a critical aspect of an integrated culture of safety in academic research settings. Showcasing best practices and sharing practical solutions for recognizing hazards and minimizing risks represent one way of reinforcing a research community's actions, attitudes, and behavior toward safety. For goals of improving chemical safety education with nonformal endeavors, safety moments are similar to 1-2 slides that focus on raising awareness and knowledge for routine safety issues in research laboratories. Intended to catalyze brief discussions at the beginning of meetings and presentations, these materials provide a proactive way for students and faculty to engage in open communication on diverse research safety topics across science and engineering. This commentary provides an overview of designing effective safety moments and tailoring them to highlight practical safety needs and considerations. Key components of model safety moment slides are presented, alongside centralized resources assembled by student-led laboratory safety teams, which can also be extended to posters, social media platforms, online videos, and other forms of scientific communication. Combined with both top-down backing from institution leaders and bottom-up support from student researchers, safety moments remain a low-barrier risk reduction strategy that is easy to implement, encourages local dialogue on safety, combats complacency, and holds potential for facilitating long-term improvements to academic lab safety culture.

Communication/Writing↗

Building a Simplistic Automatic Extruder: Instrument Development Opportunities for the Laboratory

This work presents an automatic extruder as a research experience for undergraduate students. The system offers a user-friendly approach to preparing vesicles, such as liposomes or polymersomes, with a defined size and polydispersity properties crucial for research in biology and macromolecules. It comprises two syringe pumps connected by a membrane filter. The setup is controlled by software. Compared to manual extrusion, this automated system provides advantages, such as precisely controlled variables. The project describes a tool to enhance undergraduate learning in science and engineering laboratories. Building an automatic extruder serves as a simplified model of a complex industrial process. It offers a clear advantage: automating a well-understood manual extrusion process. To make this project accessible, it is broken down into three manageable tasks: software development, hardware assembly, and testing procedures. This breakdown describes the software created, the hardware components used, and the testing procedures conducted for this project. All project data, including software code, testing data, and procedures, are freely available online. This allows undergraduate students to not only begin their own projects but also contribute to this educational instrument’s ongoing development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NEXTorch: A Design and Bayesian Optimization Toolkit for Chemical Sciences and Engineering

Automation and optimization of chemical systems require well-informed decisions on what experiments to run to reduce time, materials, and/or computations. Data-driven active learning algorithms have emerged as valuable tools to solve such tasks. Bayesian optimization, a sequential global optimization approach, is a popular active-learning framework. Past studies have demonstrated its efficiency in solving chemistry and engineering problems. Here we introduce NEXTorch, a library in Python/PyTorch, to facilitate laboratory or computational design using Bayesian optimization. NEXTorch offers fast predictive modeling, flexible optimization loops, visualization capabilities, easy interfacing with legacy software, and multiple types of parameters and data type conversions. It provides GPU acceleration, parallelization, and state-of-the-art Bayesian optimization algorithms and supports both automated an d human-in-the-loop optimization. The comprehensive online documentation introduces Bayesian optimization theory and several examples from catalyst synthesis, reaction condition optimization, parameter estimation, and reactor geometry optimization. NEXTorch is open-source and available on GitHub

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing Top-Down Proteomics of Brain Tissue with FAIMS

Proteomic investigations of Alzheimer’s and Parkinson’s disease have provided valuable insights into neurodegenerative disorders. Thus far, these investigations have largely been restricted to bottom-up approaches, hindering the degree to which one can characterize a protein’s “intact” state. Top-down proteomics (TDP) overcomes this limitation, however it is typically limited to observing only the most abundant proteoforms and of a relatively small size. Therefore, offline fractionation techniques are commonly used to reduce sample complexity, limiting throughput. A higher throughput alternative is online fractionation, such as gas phase high-field asymmetric waveform ion mobility spectrometry (FAIMS). Using a high complexity sample derived from Alzheimer’s disease brain tissue, we describe how the addition of FAIMS to TDP can robustly improve the depth of proteome coverage. For example, implementation of FAIMS at -50 compensation voltage (CV) more than doubled the mean number of non-redundant proteoforms observed (1,833 ± 17, n = 3), compared to without (754 ± 35 proteoforms). We also found FAIMS can influence the transmission of proteoforms and their charge envelopes based on their size. Importantly, FAIMS enabled the identification of intact amyloid beta (Aß) proteoforms, including the aggregation-prone Aß1-42 variant which is strongly linked to Alzheimer’s disease.

59 BASIC BIOLOGICAL SCIENCES↗

OmicsMLMentor: A Web Application for Guided Machine Learning Analysis of Omics Data

Expression-based omics technologies (e.g. proteomics, metabolomics, transcriptomics, etc.) increasingly rely on supervised and unsupervised machine learning (ML) models to find key biomolecules distinguishing conditions, identify natural groupings in biological data, or generate predictions for outcomes of interest. Fitting ML models to omics data presents several challenges, including handling missing data, selecting a normalization method, choosing a valid model, and optimizing hyperparameters, all requiring statistical programming skills to address these challenges. Thus, the open-source web application SLOPE was designed to lower the barrier to ML modeling for omics data. SLOPE supports the fitting of 15 ML models (10 supervised and 5 unsupervised) tailored to omics datasets, such as proteomics, metabolomics, lipidomics, and transcriptomics. SLOPE offers several omics-specific features, including methods for handling missingness (imputation, conversion, removal), normalization tests, ranking of models based on the structure of a user’s data and user input, and optimal hyperparameter selections using cross-validation splits. By streamlining ML workflows for omics analysis, SLOPE address critical gaps in existing online web tools, facilitating a broader adoption of these models for omics research. Here, SLOPE is applied to data from a lignin exposure study to highlight the workflow for fitting both supervised and unsupervised models to data.

lipidomics↗