Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

CORRTEX Analysis Techniques

Continuous Reflectometry for Radius versus Time Experiments, or CORRTEX, is a diagnostic that was developed during nuclear testing to measure the distance at which rock walls were disrupted by an explosive device as a function of the time at which disruption occurred. Distances recorded are dynamic measurements of cable length as the shockwaves from an explosive event crush the experiment cables, reducing their usable length. Applications of the CORRTEX diagnostic have been expanded in recent times to include instrumentation of the explosive device itself, to record phenomena such as the speed of the detonation wave in the explosive charge and the crushing or disassembly of material in the charge housing. The diagnostic has likewise been used to monitor explosive performance in rock blasting and oil well hole-clearing activities.

42 ENGINEERING↗

Cognitive Aging as a Human Factor: Effects of Age on Human Performance

Nuclear power plant (NPP) control room operators must make ongoing computations and decisions that maximize production and ensure safety, which places a high cognitive burden on the operators. How cognitions such as attention, visuospatial ability, and working memory interact with socio-technical systems to achieve optimal operations is well studied. However, there is an absence of research that examines how cognitive functioning within the NPP control room environment is moderated by developmental aging processes. This is of critical importance because different types of cognitive actions are known to develop and peak at different times across the adult life span, and it is becoming increasingly clear that there is no age at which all cognitive faculties operate at maximum capacity. Thus, given that NPPs are experiencing an aging workforce, it is vital to identify how mission critical cognitions change with age. This paper reviews implications of aging on reactor operators in the current and new fleet. We highlight lessons that can be learned from state-of-the-art human factors research that considers aging, lessons from the large cognitive aging literature, and lessons from aging workers in other industries that use sophisticated socio-technical systems, such as aviation. We also consider the important subject of aging effects versus expertise and present preliminary data that support the premise that age of operator is linked to effective and efficient operations but that this relationship may be moderated by level of operations expertise. In conclusion, we apply these lessons to future considerations for aging research in current nuclear operations and with the advent of advanced modernized control rooms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DOE Fffice of Nuclear Energy cybersecurity research, development and demonstration program plan

This document describes the Cybersecurity Research Development and Demonstration (RD&D) Program, established by the Department of Energy Office of Nuclear Energy (NE) to provide sciencebased methods and technologies necessary for cost-effective, cyber-secure digital instrumentation, control and communication in collaboration with nuclear energy stakeholders. It provides an overview of program goals, objectives, linkages to organizational strategies, management structure, and stakeholder and cross-program interfaces.

97 MATHEMATICS AND COMPUTING↗

Development of Cable Aging Acceptance Criteria for Nuclear Facilities

The aging of nuclear power plant electrical cables has been the subject of substantial research and development (R&D) projects in the nuclear industry, national and international laboratories, universities, and vendor organizations for several years. More specifically, these R&D efforts were conducted to develop equipment and techniques for assessing age-related degradation of in-service cables in nuclear facilities including power plants, research reactors, waste facilities and fuel fabrication plants. In recent years, cable R&D efforts in the nuclear arena have also included work to develop new cables for the next generation of reactors. Over time, exposure to harsh environmental conditions such as elevated temperatures, radiation, and humidity in nuclear installations can result in age-related degradation and failure of cables. In the current fleet of nuclear reactors, there are thousands of miles of cabling installed in each plant and many of these cables are exposed to these harsh environmental conditions. For these cables, the jacket and insulation polymers harden and become brittle over time, making them more susceptible to crack formation and growth, moisture intrusion, and other mechanisms that can lead to cable failure. Moreover, the existing U.S. fleet of 98 nuclear reactors has an average operating age of 38 years. Many of these nuclear power plants have applied for and almost all have been granted regulatory approval for license renewals to operate for 60 years, 20 years beyond their original 40-year life. Further, subsequent license renewals (SLRs) are underway with a few commercial nuclear power sites already approved to operate up to 80 years. As these reactors pursue operating life extensions, utilities must find a way to address issues associated with age-related degradation of cables. Designers of small modular reactors are also in need of technologies to evaluate the performance of cables that will be installed in harsher environments (e.g. higher temperatures, radiation doses, dose rates, etc.) than those present in current-generation reactors. Today, a variety of cable condition monitoring (CM) techniques have been developed and successfully used in nuclear facilities. These techniques are used to identify age-related degradation and assess the condition of cables to determine if their performance characteristics have changed with age. However, objective criteria must be developed for these CM tests to help quantify cable condition and thereby develop repair and replacement schedules. With operating life extending to 80 years and more SLRs on the horizon, both nuclear facilities and regulators need an objective means to determine the aged condition of cables.

36 MATERIALS SCIENCE↗

A Subcritical Assembly for Training and Education Use at the Oak Ridge National Laboratory

A near-final design has been completed for a new subcritical assembly at Oak Ridge National Laboratory (ORNL). This subcritical assembly will support the Nuclear Criticality Safety Program (NCSP) training and education program to augment current subcritical assembly capabilities at Sandia National Laboratories (SNL) and at the National Criticality Experiments Research Center (NCERC). Other collaborations have been proposed with the Sunrise Consortium and others. This proposed subcritical assembly uses legacy AGN-201M research reactor fuel plates that are available from the Y-12 National Security Complex. This subcritical assembly contains approximately 620 grams of 235 U as UO 2 particulates distributed homogeneously in radiation-stabilized polyethylene. The fuel plates will have a graphite neutron reflector to obtain a core multiplication, M, from 10 to 50, corresponding to a k eff of 0.9 to 0.95, respectively. The subcritical assembly will be able to support at least four experiments for the training courses: (1) the addition of fissile material to increase neutron multiplication (mass), (2) a core separation experiment (interaction), (3) the effect of adding moderators to the core (moderation), and (4) the effect of adding neutron absorbers to the core (poison/absorption). The proposed ORNL subcritical assembly will provide additional student bandwidth to support NCSP training courses and to provide for some backup capacity if nuclear facility operations are disrupted at SNL or NCERC due to some unforeseen issue. The subcritical assembly will be designed to be an inherently safe subcritical assembly—subcritical under all normal and abnormal conditions—and it will provide the capability to conduct hands-on training to support NCSP and general nuclear criticality safety (NCS) staff training and qualification goals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A multi-wavelength streaked optical pyrometer for dynamic shock compression measurements above 2500 K

This work presents a concept and implementation of a calibrated streaked spectral pyrometer (SSP) temperature diagnostic used in dynamically driven shock experiments on a two-stage gas gun. This system relies upon measuring the total system response using a tunable monochromator, a NIST-traceable calibrated power meter, and a SSP. The diagnostic performance is validated against previously measured temperatures of shock driven z-cut quartz at 99 GPa and 93 GPa. The results are found to agree with the literature to within 5% and are discussed in this manuscript. The experimental setup utilizes measurements from multiple SSP systems per sample, providing several independent measurements and substantially increasing confidence in the extrapolated shock driven sample temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mid-infrared trace detection with parts-per-quadrillion quantitation accuracy: Expanding frontiers of radiocarbon sensing

Detection sensitivity is a critical characteristic to consider during selection of spectroscopic techniques. However, high sensitivity alone is insufficient for spectroscopic measurements in spectrally congested regions. Two-color cavity ringdown spectroscopy (2C-CRDS), based on intra-cavity pump–probe detection, simultaneously achieves high detection sensitivity and selectivity. This combination enables mid-infrared detection of radiocarbon dioxide ( 14 CO 2 ) molecules in room-temperature CO 2 samples, with 1.4 parts-per-quadrillion (ppq, 10 − 15 ) sensitivity (average measurement precision) and 4.6-ppq quantitation accuracy (average calibrated measurement error for 21 samples from four separate trials) demonstrated on samples with 14 C/C up to ∼ 1.5 × natural abundance ( ∼ 1,800 ppq). These highly reproducible measurements, which are the most sensitive and quantitatively accurate in the mid-infrared, are accomplished despite the presence of orders-of-magnitude stronger, one-photon signals from other CO 2 isotopologues. This is a major achievement in laser spectroscopy. A room-temperature-operated, compact, and low-cost 2C-CRDS sensor for 14 CO 2 benefits a wide range of scientific fields that utilize 14 C for dating and isotope tracing, most notably atmospheric 14 CO 2 monitoring to track CO 2 emissions from fossil fuels. The 2C-CRDS technique significantly enhances the general utility of high-resolution mid-infrared detection for analytical measurements and fundamental chemical dynamics studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Instrumentation & Controls Study with Operating Experience Data

The slides present the plan and working progress on the digital instrumentation and control (DI&C) study with nuclear industry operating experience data. They were originally prepared as a working document and presented to the NRC, but then was asked by the NRC to present to an EPRI/NRC meeting on DI&C. The slides will also be distributed to the meeting participants.

99 GENERAL AND MISCELLANEOUS↗

Development and experimental evaluation of an acoustic flow meter prototype for measuring air flow

Here, this study outlines the development and testing of a flow meter prototype specifically designed for use in nuclear reactor environments. The meter uses flow-induced vibration to measure flow rates and is designed for remote monitoring in harsh environments where radiation can damage electronics. The device generates a vibration signal produced by a feedback system when fluid flows out of an orifice and interacts with a downstream wedge. The frequency of the vibration signal corresponds directly to flow rate and velocity. The study investigates geometric parameters intrinsic to the prototype, such as orifice height, width, edge distance, and chamber length. Different configurations were also tested, including a bypass loop with variable cross-sections around the device. The investigation results reveal the impact of these geometric parameters on the vibration signal output, providing valuable insights for future design improvements and enhancing the effectiveness of flow metering systems used in nuclear reactor applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SEDONA SpEctroscopic Detection Of Nerve Agents

Although the threat of a liquid explosive attack on a passenger aircraft has been mitigated by limiting the size of carry-on bottles, highly potent chemicals (e.g., nerve agents) are a very serious threat. A single travel bottle full of such chemicals would cause great harm to many people and create a national security incident disrupting civilian air travel. Current screening methods to detect highly potent chemicals require opening a closed bottle. Experts at Los Alamos National Laboratory have developed SEDONA, a low magnetic field nuclear magnetic resonance (NMR) to detect chemical threats through unopened bottles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Description of Sensor Assignment Optimization Method as Deployed on a Multi-Node Cluster

Data analytic methods are being developed to address the problem of how to assign a sensor set in a nuclear facility such that a requisite level of process monitoring capability is realized and that the sensor set is sufficiently rich to determine the status of the individual sensors with respect to need for calibration. There is an awareness in the nuclear industry that data analytics combined with rich sensor sets represent a means to improve operations and reduce costs. In the industry the calibration problem has been previously approached as an empirical data-driven problem with several methods having been developed. However, the experience of the utilities over the past ten years with these methods indicates that the absence of physics-based information renders the data-driven approach less reliable. Complicating factors such as the inherent variability of operation (both equipment alignment and operating condition) can confound a pure data-driven approach while there are no rigorous guidelines for determining what constitutes an adequate sensor set. The solution under development to overcome these shortcomings supplements the data analytic method with process information in a so-called process-constrained data-analytic approach. Simple balance equations are written for generic components (e.g., mechanical pump, valve, and heat exchanger). These do not require a priori knowledge of process parameters, such as heat transfer coefficients or friction factors. All that is needed on the part of the utility user is to identify the components and how they are connected. This report describes the development of a parallel computing capability for determining the optimal sensor set. The optimal sensor set problem suffers from the curse of dimensionality. Computation time increases exponentially as the size of the system grows. To overcome this difficulty a pre-conditioner algorithm is developed to find an approximate solution close the actual solution. This serves as a seed for the full-blown algorithm and acts to constrain the space that must searched. The optimization algorithms are described and the implementation on a parallel computing platform is described. The application of the method to a use case we are solving in collaboration with our utility partner served to illustrate how the default sensor set in a nuclear plant may not provide sufficient coverage to infer sensor calibration status.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lanthanide doped barium mixed halide scintillators

The present invention provides for a composition comprising an inorganic scintillator comprising an optionally lanthanide-doped barium mixed halide, useful for detecting nuclear material.

36 MATERIALS SCIENCE↗

Nondestructive measurements of residual 235 U mass of Israeli Research Reactor-1 fuel using the Advanced Experimental Fuel Counter

In 2018, a measurement campaign took place with participants from Los Alamos National Laboratory (LANL), the Nuclear Research Centre-Negev (NRCN) and Soreq Nuclear Research Center (SNRC) at the Israeli Research Reactor-1 (IRR-1) in which 14 of the reactor’s used fuel assemblies (FAs) with varied amount of depletion were measured with the nondestructive assay instrument Advanced Experimental Fuel Counter (AEFC). Designed for safeguards purposes, the AEFC measures both neutrons emitted from the FA (passive neutrons) and fission neutrons induced by an external neutron source (in this experiment, 252 Cf). Signals recorded with the AEFC include total neutron count rates (Singles), time-correlated neutron count rates (Doubles), and total gamma-ray count rates. The 235 U content of the FAs was previously assessed by two independent methods: (1) measurement of the transparency of the FA to low-energy gamma rays from an activated rhenium source (rhenium gamma transmission, or the RGT method) and (2) calculation of the 30-year burnup history of the core using detailed three-dimensional Monte-Carlo core depletion calculations. The results from the FAs that had been measured via the RGT method were used to construct the calibration curves, which translate the AEFC count rates to 235 U mass. Then, the calibration was evaluated using AEFC measurements of six additional FAs that were not measured via the RGT method. From the results, it was determined the Doubles calibration curve was more reliable than that of the Singles and follows a simple second-order polynomial fit for the whole range of residual 235 U mass content, albeit with larger statistical uncertainty. Detailed uncertainties quantification was conducted for both the AEFC Singles and Doubles. This includes the analysis of statistical uncertainties, calibration uncertainty, and random uncertainties due to the sensitivity of the AEFC to several sources of uncertainty, namely the FA position, FA orientation, interrogation source position, and ambient pool temperature. Finally, an overall total uncertainty of 6 g of 235 U is estimated for the Singles and Doubles, which is mainly due to calibration uncertainty (for the Singles) and statistical uncertainty (for the Doubles), and which constitutes 3%–6% of the 235 U total mass in the FAs, depending on their level of depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Phase-1 Pixel Detector Upgrade

The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 10-Gb/s Driver/Receiver ASIC and Optical Modules for Particle Physics Experiments

We present the design and test results of a Drivers and Limiting AmplifierS ASIC operating at 10 Gbps (DLAS10) and three Miniature Optical Transmitter/Receiver/Transceiver modules (MTx+, MRx+, and MTRx+) based on DLAS10. DLAS10 can drive two Transmitter Optical Sub-Assemblies (TOSAs) of Vertical Cavity Surface Emitting Lasers (VCSELs), receive the signals from two Receiver Optical Sub-Assemblies (ROSAs) that have no embedded limiting amplifiers, or drive a VCSEL TOSA and receive the signal from a ROSA, respectively. Each channel of DLAS10 consists of an input Continuous Time Linear Equalizer (CTLE), a four-stage limiting amplifier (LA), and an output driver. The LA amplifies the signals of variable levels to a stable swing. The output driver drives VCSELs or impedance-controlled traces. DLAS10 is fabricated in a 65 nm CMOS technology. The die is 1 mm x 1 mm. DLAS10 is packaged in a 4 mm x 4 mm 24-pin quad-flat no-leads (QFN) package. DLAS10 has been tested in MTx+, MRx+, and MTRx+ modules. Both measured optical and electrical eye diagrams pass the 10 Gbps eye mask test. Furthermore, the input electrical sensitivity is 40 mVp-p, while the input optical sensitivity is -12 dBm. The total jitter of MRx+ is 29 ps (P-P) with a random jitter of 1.6 ps (RMS) and a deterministic jitter of 9.9 ps. Each MTx+/MTRx+ module consumes 82 mW/ch and 174 mW/ch, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗